Study guide
1.5 Permits, Inspections, Structural Integrity & Job Estimating
Oklahoma Journeyman Electrician Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oklahoma Licensing Laws, Board Rules & Safety
1.1 Oklahoma Electrical License Act & CIB Regulations 1.2 OK Journeyman Exam Format, PSI Logistics & Codebook Navigation 1.3 OSHA Electrical Safety Standards (29 CFR 1926/1910) 1.4 NFPA 70E Electrical Safety in the Workplace & Arc Flash 1.5 Permits, Inspections, Structural Integrity & Job Estimating 1.6 Oklahoma's Adopted 2023 NEC: OUBCC Amendments You Must Know 1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection
2 Chapter 2: General Electrical Theory & Calculations
2.1 Ohm's Law, Watt's Law & DC Series/Parallel Circuits 2.2 AC Theory, Reactance, Impedance & Power Factor 2.3 Three-Phase Power Systems (Delta & Wye Configurations) 2.4 Electrical Units, Formulas & Conversions 2.5 Cost of Power in a Circuit, Efficiency & Troubleshooting/Test Instruments
3 Chapter 3: General Installation Requirements (NEC Article 110)
3.1 Examination, Identification, Installation & Use of Equipment (110.3) 3.2 Electrical Connections, Terminations & Torque Requirements (110.14) 3.3 Working Space, Clearances & Guarding of Live Parts (110.26 & 110.27) 3.4 Enclosure Types, Markings & Available Fault Current (110.24 & 110.28) 3.5 Installations Over 600 Volts: Article 110 Part III, Article 490 & Medium-Voltage Cable
4 Chapter 4: Branch Circuits & Feeders (NEC Articles 210, 215 & 225)
4.1 Branch Circuit Ratings, Multiwire Branch Circuits & Identification (210.3–210.10) 4.2 Ground-Fault Circuit-Interrupter (GFCI) Protection (210.8) 4.3 Arc-Fault Circuit-Interrupter (AFCI) Protection & Receptacle Outlets (210.12 & 210.52) 4.4 Outside Branch Circuits and Feeders (Article 225) & Feeder Sizing (Article 215)
5 Chapter 5: Services & Service Equipment (NEC Article 230)
5.1 Service Clearances, Overhead & Underground Service-Drop Requirements (230.9, 230.24 & 230.30) 5.2 Service-Entrance Conductors, Sizing & Installation (230.40–230.54) 5.3 Service Equipment Disconnecting Means, Overcurrent Protection & Emergency Disconnects (230.70–230.95)
6 Chapter 6: Electrical Load Calculations (NEC Article 220)
6.1 General Lighting, Small Appliance & Laundry Loads (NEC 220.41, 220.42, 220.45 & 220.52) 6.2 Standard Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part III) 6.3 Optional Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part IV) 6.4 Commercial & Multi-Family Load Calculations (Cooktops, Dryers, HVAC & Stores)
7 Chapter 7: Overcurrent Protection & Tap Rules (NEC Article 240)
7.1 Overcurrent Protection Fundamentals & Standard Ampere Ratings (240.4 & 240.6) 7.2 Feeder & Branch Circuit Tap Rules (NEC 240.21) 7.3 Ground-Fault Protection of Equipment & Selective Coordination (NEC 240.13, 240.86 & Article 245)
8 Chapter 8: Grounding and Bonding (NEC Article 250)
8.1 General Grounding Principles, System Grounding & Grounded Conductors (NEC 250.4, 250.20 & 250.24) 8.2 Grounding Electrode System & Grounding Electrode Conductor (GEC) Sizing (NEC 250.50, 250.52 & 250.66) 8.3 Equipment Grounding Conductors (EGC) Sizing & Installation (NEC 250.118, 250.120 & 250.122) 8.4 Bonding Requirements, Main/System Bonding Jumpers & Separately Derived Systems (NEC 250.28, 250.30 & 250.102)
9 Chapter 9: Wiring Methods & Materials (NEC Articles 300–314)
9.1 General Requirements for Wiring Methods, Underground Clearances & Firestopping (NEC Article 300) 9.2 Conductor Ampacity Ratings, Temperature Correction & Bundling Adjustments (Article 310 & Table 310.16) 9.3 Nonmetallic-Sheathed Cable (Type NM), Metal-Clad Cable (Type MC) & Armored Cable (Type AC) 9.4 Outlet, Device, Pull & Junction Boxes Sizing and Box Fill Calculations (NEC Article 314) 9.5 Temporary Installations (Article 590), Cranes & Hoists (Article 610), Elevators & Escalators (Article 620)
10 Chapter 10: Raceways, Tubing, Conduit Fill & Underground Systems
10.1 Rigid Metal Conduit (RMC), Intermediate Metal Conduit (IMC) & Electrical Metallic Tubing (EMT) 10.2 Nonmetallic Raceways (PVC, RTRC, Liquidtight) & Cable Trays (NEC Articles 352, 356, 392) 10.3 Conduit Fill Calculations (Chapter 9 Tables 1, 4 & 5, Annex C) & Pull Box Sizing (NEC 314.28)
11 Chapter 11: Motors, Controllers & Air Conditioning (NEC Articles 430 & 440)
11.1 Motor Full-Load Current (FLC), Branch Circuit Conductor Sizing & Disconnects (430.6, 430.22 & 430.102) 11.2 Motor Overload Protection & Motor Branch Circuit Short-Circuit/Ground-Fault Protection (430.32 & 430.52) 11.3 Motor Feeder Conductor Sizing & Feeder Overcurrent Protection (430.24 & 430.62) 11.4 Air Conditioning & Refrigeration Equipment (NEC Article 440: MCA, MOCP & Disconnects)
12 Chapter 12: Transformers & Equipment (NEC Articles 450, 410, 422 & 424)
12.1 Transformer Sizing, Protection & Voltage Calculations (NEC Article 450 & Table 450.3(B)) 12.2 Luminaires, Lampholders & Lamps Installation (NEC Article 410) 12.3 Appliances & Electric Water Heaters (NEC Article 422) 12.4 Fixed Electric Space-Heating Equipment (NEC Article 424) 12.5 Snow-Melting & De-Icing Equipment (Article 426) and Pipeline & Vessel Heating (Article 427) 12.6 Electric Signs & Outline Lighting (Article 600) and Lighting Systems 30 Volts or Less (Article 411)
13 Chapter 13: Special Occupancies & Hazardous Locations (NEC Articles 500–517)
13.1 Hazardous (Classified) Locations: Class I, II, and III (Articles 500, 501, 502 & 503) 13.2 Commercial Garages, Repair Facilities & Fuel Dispensing Facilities (Articles 511 & 514) 13.3 Health Care Facilities: Patient Care Spaces & Wiring Methods (Article 517) 13.4 Agricultural Buildings & Manufactured/Mobile Homes (Articles 547 & 550) 13.5 Bulk Storage Plants (Article 515) and Spray Application, Dipping & Coating (Article 516)
14 Chapter 14: Special Equipment, Swimming Pools & Low-Voltage Systems
14.1 Swimming Pools, Spas, Hot Tubs & Hydromassage Bathtubs (Article 680) 14.2 Emergency Systems, Legally Required & Optional Standby Systems (Articles 700, 701 & 702) 14.3 Class 1, 2, 3 & Class 4 Power-Limited Circuits (NEC Articles 722, 724, 725 & 726) and Fire Alarms (NEC Article 760) 14.4 RV Parks (Article 551), Floating Buildings (Article 553) & Marinas/Docking Facilities (Article 555)
1.5 Permits, Inspections, Structural Integrity & Job Estimating
Key Takeaways Explain This Topic AI
PSI allocates 4 scored items to "General Knowledge," whose three sub-topics are permits and inspections, preservation of structural integrity, and needs analysis and estimate — none of which are NEC calculation topics.
NEC 90.4 makes the authority having jurisdiction the interpreter of the Code, with authority to approve alternatives, waive specific requirements, and permit alternate methods where safety is maintained.
NEC 300.4(A)(1) requires a bored hole in a wood member to be at least 1¼ in. from the nearest edge, or the cable must be protected by a steel plate at least 1/16 in. thick; notches get the same 1/16 in. plate under 300.4(A)(2).
Cables and raceways run parallel to framing members must be kept 1¼ in. back from the nearest edge (300.4(D)), and cables under metal-corrugated roof decking must be at least 1½ in. from the lowest surface of the decking (300.4(E)).
An estimate is built from a quantity takeoff priced at material cost plus labor units, then loaded with overhead and profit; labor units — not copper price — are what usually decide whether a bid is profitable.
Last updated: August 2026
1.5 Permits, Inspections, Structural Integrity & Job Estimating
The very first subject area in the PSI content outline is General Knowledge , worth 4 scored items , and it is the one candidates most often skip. Its three sub-topics — permits and inspections , preservation of structural integrity , and needs analysis and estimate — are not calculation topics and are not concentrated in a single NEC article, so they are easy to leave un-studied and easy to lose outright.
1. Permits and Inspections: Who Has Authority Over Your Work
The NEC does not enforce itself. NEC 90.4 states that the Code is intended to be suitable for mandatory application by governmental bodies exercising legal jurisdiction over electrical installations, and it gives the authority having jurisdiction (AHJ) four specific powers:
NEC 90.4 Power of the AHJ What it means on your job
Interpretation of the rules The inspector’s reading of an ambiguous section governs the installation until it is formally appealed.
Approval of equipment, materials, and installation methods "Approved" in the NEC means acceptable to the AHJ — not "listed," and not "I have always done it this way."
Granting special permission Written consent from the AHJ, required by name in sections such as 426.14 and 230.2(A)(5).
Waiving specific requirements or permitting alternate methods Allowed only where equivalent objectives can be achieved by establishing and maintaining effective safety.
NEC 90.4 also says that where the Code requires new products, constructions, or materials that may not yet be available at adoption, the AHJ may permit the use of the products and methods that complied with the previous edition adopted by that jurisdiction.
The Oklahoma permitting chain
In Oklahoma the enforcement chain runs through three levels, and the exam expects you to keep them straight:
OUBCC adopts the code. Under 59 O.S. § 1000.23, the Oklahoma Uniform Building Code Commission adopts the NEC as the statewide minimum code for commercial electrical construction. OAC 158:40-1-4 makes those adopted codes the standard of installation for CIB enforcement purposes.
Municipalities inspect the work. Under 59 O.S. § 1693, cities and towns may establish electrical inspection departments, appoint inspectors, require state-licensed contractors to register locally before pulling permits, and charge a reasonable registration fee — but they may not re-test a state-licensed electrician’s trade competency.
The CIB licenses and disciplines the people. The Board does not perform routine field inspections; it acts on complaints, unlicensed activity, and violations referred to the Electrical Hearing Board.
Important
The permit belongs to the license holder. Permits are pulled by the licensed electrical contractor performing the work, not by the journeyman and not by the property owner acting as a pass-through for an unlicensed installer. Oklahoma also recognizes an annual permit for maintenance work: OAC 748:20-10-3(c) adopts a modified Annex H 80.19(D), letting a building official issue one yearly permit representing a group of individual permits for alterations to already-approved installations, provided the permit holder keeps a detailed record of alterations and files it with the building official at the end of the term.
Inspection sequence
A typical commercial job is inspected at four points, and the sequencing rule that gets tested is that concealed work must be inspected before it is covered :
Temporary service / saw-service inspection — before construction power is energized.
Underground / slab inspection — before backfill or before the concrete pour, while conduit stub-ups, grounding electrodes, and under-slab raceways are still visible.
Rough-in inspection — after boxes, raceways, cables, and grounding are installed but before insulation, drywall, or fireproofing conceals them.
Final inspection — with devices, luminaires, panel directories, equipment labeling (including the 110.24 available fault-current marking) and grounding complete.
Covering concealed work before the rough-in inspection is the single most expensive scheduling mistake on a job, because the remedy is demolition of finished surfaces at the contractor’s cost.
2. Preservation of Structural Integrity
An electrician who bores and notches carelessly can turn a code-compliant building into a structurally deficient one. Two rule sets govern this: the NEC protects the conductor , and the building code protects the member .
NEC 300.4 — protecting the wiring
NEC Section Condition Requirement
300.4(A)(1) Cables or raceways through bored holes in wood joists, rafters, or studs Hole edge not less than 1¼ in. (32 mm) from the nearest edge of the wood member; otherwise protect with a steel plate/bushing at least 1/16 in. (1.6 mm) thick
300.4(A)(2) Cables or raceways in notches in wood Protect from nails/screws with a steel plate at least 1/16 in. thick installed before building finish is applied
300.4(B) Nonmetallic-sheathed cable through metal framing members Protect with a listed bushing or grommet at each penetration; where nails or screws are likely, add a 1/16 in. steel plate
300.4(D) Cables/raceways run parallel to framing members or furring strips Keep the wiring 1¼ in. back from the nearest edge, or protect with a 1/16 in. steel plate
300.4(E) Cables/raceways under metal-corrugated sheet roof decking Not less than 1½ in. (38 mm) from the lowest surface of the roof decking to the nearest surface of the wiring method
300.4(F) Cables/raceways under wood roof decking Not less than 1½ in. from the nearest edge of the roof decking
Building-code limits on the member itself
The NEC never authorizes a hole the structure cannot take. The residential code limits are the ones most often quoted on trade exams:
Bearing-wall studs: bored holes limited to 40% of the stud width; notches limited to 25% of the width.
Nonbearing studs: bored holes limited to 60% of the width; notches limited to 40% .
Joists and rafters: bored holes limited to one-third of the member depth and kept at least 2 in. from the top and bottom edges; notches limited to one-sixth of the depth, never in the middle third of the span, and end notches limited to one-fourth of the depth.
Engineered lumber (I-joists, LVL, trusses) may be drilled only per the manufacturer’s hole chart. Truss chords and webs are never to be cut. Where a member is over-bored, the remedy is a licensed design professional’s repair detail, not a bigger nail plate.
Fire-resistance-rated assemblies bring a second obligation: NEC 300.21 requires that penetrations of fire-rated walls, floors, and ceilings be firestopped using approved methods so the fire-resistance rating is maintained.
3. Needs Analysis and Estimate
A "needs analysis" is the front-end scoping conversation and site survey: what loads exist, what the customer intends to add, whether the existing service and available fault current can carry it, and what the code will require that the customer has not asked for (GFCI/AFCI upgrades, working space, disconnects, grounding electrode upgrades).
The estimate that follows is a repeatable five-step arithmetic:
Quantity takeoff. Count every device, box, luminaire, and fitting; measure every raceway and cable run with an allowance for waste (commonly 5–10%).
Material pricing. Extend each quantity by unit cost. Copper and aluminum are volatile, so material quotes are typically held for a limited period.
Labor units. Each item carries a published labor unit — hours to install one unit under normal conditions. Multiply quantity × labor unit to get raw labor hours, then apply a difficulty/conditions factor (high ceilings, occupied buildings, night work, congested ceiling space) that can exceed 1.5.
Direct job expenses. Permits and inspection fees, lifts and trenchers, temporary power, testing, engineering, and as-builts.
Overhead and profit. Fixed overhead is recovered as a percentage of cost; profit is added on top of the loaded cost.
Worked example. A takeoff shows 240 receptacle outlets at a labor unit of 0.45 hours each. Raw labor is 240 × 0.45 = 108 hours . The work is in an occupied hospital wing requiring a 1.35 conditions factor: 108 × 1.35 = 145.8 hours . At a $62/hour loaded labor rate, labor is $9,040. If material for those outlets is $7,100, direct cost is $16,140; at 18% overhead and 10% profit the sell price is $16,140 × 1.18 × 1.10 ≈ $20,950 .
Two traps live in that arithmetic. First, the conditions factor, not the labor unit, is where estimates go wrong — the published unit assumes open, unoccupied, ground-level work. Second, change orders must be priced and signed before the work is performed ; unpriced extras are the most common source of unrecoverable cost on a licensed contractor’s job.