Study guide
21.2 Handling and Disposing of Chemicals
Oregon Barber License Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Oregon Barber Exam Overview
1.1 Current Exam Facts 1.2 Pathways, Fees, and Retake Rules 1.3 How to Study Both Oregon Written Exams
2 Hair Structure, Trichology & Growth
2.1 Trichology and Hair Structure 2.2 Hair Growth Cycles and Patterns 2.3 Hair Color, Pigment, and Melanin in Hair
3 Hair Loss, Hair Disorders & Scalp Disorders
3.1 Hair Loss and Alopecia Types 3.2 Hair Diseases and Disorders 3.3 Scalp Diseases and Disorders
4 Skin Histology
4.1 Structure of the Skin 4.2 Melanin and Skin Pigmentation 4.3 Skin Diseases and Disorders
5 Anatomy of the Head and Face
5.1 Bones of the Head and Face 5.2 Muscles of the Head, Face, and Neck 5.3 Nerves of the Head and Face
6 Microbiology for Oregon Barbers
6.1 Bacteria and Viruses 6.2 Immunity and Parasites
7 Client Consultation, Analysis & Treatments
7.1 Client Consultation and Physician Referral 7.2 Hair, Scalp, and Skin Analysis 7.3 Hair, Scalp, and Skin Treatments
8 Hair Care & Skin Care Procedures
8.1 Scalp Massage and Shampoo Service 8.2 Facials and Facial Massage
9 Design Elements
9.1 Facial Shapes, Head Form, and Profiles 9.2 Elevations, Form, and Texture 9.3 Shape, Balance, and Proportion
10 Cutting and Styling Procedures
10.1 Shear Cutting and Razor Cutting 10.2 Clipper Cutting, Blending, Tapering, and Fading 10.3 Arching, Outlines, and Head Shaving 10.4 Thermal Styling and Artificial Hair
11 Shaving Procedures
11.1 Areas of the Face and Shaving Technique 11.2 Steaming, Lathering, and Shaving Strokes 11.3 Finishing Step After the Shave
12 Implements, Tools and Equipment
12.1 Shears and Razors 12.2 Clippers, Combs, and Brushes 12.3 Capes, Drapes, and Massage Tools
13 Product Knowledge and Chemistry
13.1 Shampoos and Conditioners 13.2 Styling Aids and Shaving Products 13.3 pH, Water, and Cosmetic Chemistry
14 Safety, Infection Control & Federal Standards
14.1 Safe Usage and Safety Devices 14.2 OSHA, FDA, EPA, and CDC Standards
15 Oregon Definitions & Scope of Barbering
15.1 Statutory Definition and Scope of Barbering 15.2 Certificate, Authorization, and Fields of Practice 15.3 Facility, Freelance, and Independent Contractor Definitions 15.4 Board, HLO, and Key OAR 817 Terms
16 Facility Licensure & Physical Standards
16.1 Facility License and Application Requirements 16.2 Water Supply, Restrooms, Floors, Walls, and Ceilings 16.3 Residential Facilities and Temporary Facility Permits
17 Infection Control in the Oregon Shop
17.1 Servicing Clients 17.2 Towels, Linens, and Articles in Contact with Clients 17.3 Disinfecting Non-Electrical and Electrical Tools 17.4 Storage of Tools, Refuse, and Waste
18 Shop Hygiene, Equipment & Client Protection
18.1 Hairpieces, Equipment, and Pets in Facilities 18.2 Cleanable, Non-Absorbent Surfaces 18.3 Client Protection During Services
19 Practice Standards & Business Authorizations
19.1 Practice Standards and Professional Conduct 19.2 Freelance Authorization and Independent Contractor 19.3 Posting Requirements and Facility Operations
20 Examinations, Licensing & Renewal
20.1 Written Examination Rules and Retake Policy 20.2 Practitioner Certificate and 746-Hour Curriculum 20.3 Renewal, Bloodborne Pathogens Training, Inactive and Reinstatement
21 Chemicals, Storage & Civil Penalties
21.1 Chemical Use, Storage, and Formaldehyde 21.2 Handling and Disposing of Chemicals 21.3 Civil Penalties and HLO Enforcement
21.2 Handling and Disposing of Chemicals
Key Takeaways Explain This Topic AI
OAR 817-005-0005(11) defines a dispensing area as nonporous surfaces plus a sink with hot and cold running water where mixing, tool cleaning, residue disposal, and rinsing chemically exposed skin occur. OAR 817-060-0030(1) requires client-service chemicals to be mixed there, with adequate ventilation, away from open flame and other ignition.
OAR 817-060-0030(2) requires disposal according to the manufacturer and local and state environmental rules. Unlabeled secondary bottles also fail Hazard Communication (29 CFR 1910.1200), which OAR 817-060-0010(2) incorporates with ORS 654, OAR 437 Division 2, and 29 CFR 1910.1030.
OAR 817-060-0030(3) prohibits FDA-banned cosmetic hazardous substances, FDA-unapproved uses, products MSDS characterize as hazardous or harmful to humans, and an open flame at the workstation during any phase of a chemical service.
OAR 817-010-0060(1): chemical waste goes in a closed container at the conclusion of each service and in a fire-retardant (airtight metal) container at the end of each business day. Chemically soiled towels follow OAR 817-010-0035(4).
OAR 817-060-0010 requires every safety procedure that prevents eye, nail, hair, or skin injury or clothing damage during chemical services, plus OR-OSHA and federal bloodborne and Hazard Communication rules. Drape, cotton, protective cream, and adequate ventilation (817-005-0005(1)) are how that duty looks in a shop. Do not invent hair-color mixing ratios; barbering does not include chemical restructuring.
Last updated: August 2026
21.2 Handling and Disposing of Chemicals
Quick Answer: Mix client-service chemicals in a dispensing area — nonporous surfaces and a sink with hot and cold running water — with adequate ventilation and no open flame . Keep every bottle labeled . Follow the manufacturer . Close chemical waste at the end of the service and move it to an airtight metal fire-retardant container at the end of the day . Protect the client’s eyes, skin, hair, nails, and clothes. Do not invent a hair-color mixing ratio; Oregon barbering does not include chemical restructuring.
OAR 817-060-0030 is Use, Handling and Disposing of Chemicals. OAR 817-060-0010 is Client Protection. OAR 817-010-0060(1) is the chemical-waste clock this division relies on. Together they are how the laws exam turns an 8-item Chemicals cluster into shop pictures: where you mix, what you refuse to use, how the client is draped, and where the wet waste goes at 8 p.m.
Mix only in a real dispensing area
OAR 817-060-0030(1): chemicals used for providing services to clients must be mixed in a dispensing area , which has adequate ventilation away from open flame or other sources of potential ignition .
OAR 817-005-0005(11) defines dispensing area as an area with nonporous surfaces and a sink with hot and cold running water where service preparations are conducted, including, but not limited to, mixing of chemicals , cleaning of tools and equipment , disposing of residues , and rinsing parts of the body exposed to chemicals . Four pieces, not one: nonporous, hot water, cold water, and the work of mixing and rinsing. A carpeted break room with a coffee maker is not a dispensing area. A chair-side cup of disinfectant mixed over a client’s cape is not a dispensing area. A restroom sink used because the dispensary drain is slow is not a dispensing area.
OAR 817-005-0005(1) defines adequate ventilation as ventilation by natural or mechanical methods that removes or exhausts fumes, vapors, or dust to prevent hazardous conditions in accordance with OAR Chapter 437, Division 2 , or that allows the free flow of air in a room in proportion to the size and capacity of the room. Crack-the-door is not a ventilation plan when a chemical service is producing vapor. OAR 817-005-0005(8) lists dispensing areas among common areas used by all authorization holders. In a mixed shop, the barber and the hair designer share that room. Mixing in the common dispensary is still mixing in a dispensing area. Mixing at the front desk is not.
OAR 817-090-0115(2) makes failing to mix in a dispensing area a chemical-use civil penalty. 817-090-0115(3) makes mixing or using chemicals near an open flame or other potential ignition the same schedule. Learn the handling rule here; the dollar amounts sit in 21.3.
Labels, manufacturer, FDA, MSDS, and no flame at the station
OAR 817-060-0030(2): all chemicals must be disposed of in accordance with their manufacturer’s instructions and according to local and state environmental requirements . A bottle with no name has no manufacturer instructions you can follow. OAR 817-060-0010(2) requires client-protection regulations to be met in accordance with ORS 654 , OAR 437 Division 2 , 29 CFR 1910.1030 (bloodborne pathogens), and 29 CFR 1910.1200 (Hazard Communication). Hazard Communication requires labels on hazardous-chemical containers. Pouring a concentrated disinfectant into an unlabeled water bottle “so it looks nicer on the station” is not a storage shortcut. It is an unlabeled hazardous container and a manufacturer-instruction failure the moment you need the SDS (the rule text still says MSDS ) or the disposal line.
OAR 817-060-0030(3) then lists four prohibitions. Authorization holders are prohibited from:
(a) Using cosmetic products containing hazardous substances banned by the U.S. Food and Drug Administration for use in cosmetic products.
(b) Using products in a manner not approved by the FDA .
(c) Using any product containing compounds or substances characterized as hazardous or harmful to humans by Material Safety Data Sheets (MSDS) and/or random product testing — see OAR chapter 817 division 060.
(d) Using an open flame at the workstation during any phase of chemical service .
(a) and (b) are FDA. A banned ingredient does not become legal because a supply house still ships it. Using a product off-label — heating a product the FDA-facing label says not to heat, applying a leave-on as a leave-in when the label forbids it — is (b). (c) is the SDS/MSDS screen: if the sheet characterizes the substance as hazardous or harmful to humans, you do not use it as a cosmetic service product. (d) is the flame rule at the workstation during any phase of a chemical service: mixing, application, processing, or use of a potentially explosive or flammable chemical. OAR 817-090-0115(4) writes that workstation-flame picture into the penalty schedule (the penalty rule still cites an older “(4)(d)” numbering; the current handling rule is 817-060-0030(3)(d) ). A birthday candle on the station during a chemical service is not cute. It is a prohibited ignition source.
Do not invent a mixing ratio for hair color, toner, or perm lotion on this exam. Those services are out of barbering scope . Division 60 does not publish a 1:1 or 1:2 color-developer recipe, and this guide will not either. If a question is about disinfectant dilution for non-sharp tools, the source is already OAR 817-010-0068(6) as taught in chapter 17: completely immerse in 1,000 ppm of a commercial quaternary ammonium compound or other low-level disinfectant according to the manufacturer . Do not rewrite that number here, and do not substitute a color-developer ratio for a quat jar.
Two clocks for chemical waste
Handling ends in waste. OAR 817-010-0060(1) — the sentence Division 60 points at in 817-060-0020(7) — is two clocks, not one:
All chemical waste material must be disposed of in a closed container at the conclusion of each service .
And disposed of in a fire-retardant container at the end of each business day .
Closed at the end of the service. Fire-retardant — airtight metal under OAR 817-005-0005(20) — at the end of the day. Cotton, foil, or towels damp with disinfectant, alcohol, or a neighboring perm solution that sit in an open plastic can until Saturday fail both clocks. OAR 817-010-0035(4) separately requires chemically soiled towels or linens in fire-retardant containers; 817-090-0070(3) and 817-090-0075(1) are the penalty mirrors (first-offense $300 on the current schedules). Chapter 17 taught the full refuse rule, including blood waste and sharps. This section only restates the chemical clocks so a Chemicals item does not send you hunting through Facility Standards.
OAR 817-010-0055 still governs substances that contact hair or skin: dispense so the unused portion stays uncontaminated, cover when not in use, hold manufacturer temperature, keep debris out, dispose immediately under 817-010-0060. Barbers do not wax, but a mixed facility with wax or other cosmetic preparations on the premises still follows that dispensing rule. 817-090-0080 is the penalty schedule for failing to dispense powders, liquids, wave solutions, creams, or other client-contact materials properly.
- Duty Rule Shop picture that fails
- Mix in a dispensing area 817-060-0030(1); 817-005-0005(11) Mixing disinfectant in a mug at the chair
Ventilation, no ignition while mixing 817-060-0030(1); 817-005-0005(1) Mixing next to a candle or with a dead exhaust fan
Manufacturer plus environmental disposal 817-060-0030(2) Dumping leftover concentrate in the alley
Keep identity on the container 817-060-0010(2) via 29 CFR 1910.1200 Quats poured into an unlabeled water bottle
No FDA-banned or unapproved use 817-060-0030(3)(a)–(b) Using a banned cosmetic or heating a product the label forbids
- No MSDS-flagged harmful product 817-060-0030(3)(c) Using a product the SDS calls harmful to humans
- No open flame at the workstation 817-060-0030(3)(d) Flame on the station during any chemical-service phase
Chemical waste closed, then metal 817-010-0060(1); 817-005-0005(20) Open plastic can of damp chemical cotton overnight
Client protection is a duty, not a drape preference
OAR 817-060-0010(1): all safety procedures which prevent eye, nail, hair, or skin injury to clients or damage to the clothing of clients must be followed when administering chemical services. The Board does not print a shopping list in that sentence. The procedures that actually prevent those injuries in a shop are the ones the exam expects you to choose: a cape (with a neck strip or towel under OAR 817-010-0040(1) so a common-use hair cloth never sits on skin), cotton at the hairline or ears when a product can run, and a protective cream on skin that a chemical could burn. Skip the barrier and a splash of disinfectant, alcohol, or a coworker’s perm solution becomes a 817-060-0010(1) injury or a ruined shirt.
OAR 817-060-0010(2) stacks ORS 654 (Oregon Safe Employment Act), OAR 437 Division 2 , 29 CFR 1910.1030 , and 29 CFR 1910.1200 on top of that. Gloves, eye protection when spatter is likely ( OAR 817-010-0008 , the current servicing-clients rule after OAR 817-015-0030 was repealed effective July 1, 2024), labeled containers, and SDS access are not optional extras for “real chemical days.” They are how client-protection regulations are met. Adequate ventilation under 817-005-0005(1) is part of keeping fumes from becoming a hazardous condition for the person in the chair and the person holding the bowl.
A barber who never applies color still administers chemical services when mixing and using disinfectant, alcohol, or other products that change the appearance of hair, skin, or nails. The drape still goes on. The cotton still goes on if the product can run. The cream still goes on if the product can burn skin. The exhaust still runs. “Barbers don’t do chemicals” is the trap the 8-item Chemicals cluster is written to catch.
An Astoria mug and an unlabeled bottle
Marcus, a barber in Astoria, mixes a fresh batch of disinfectant in a ceramic mug at the chair because the dispensary sink is stacked with bowls. He poured last week’s concentrate into an unlabeled water bottle. He drapes the client with a common cape on bare skin, no neck strip, and leaves peroxide-damp cotton from the hair designer’s last foil in an open plastic can. A tea light sits on the station “for atmosphere.” OAR 817-060-0030(1) required mixing in a dispensing area with nonporous surfaces, hot and cold water, ventilation, and no ignition. OAR 817-060-0010(2) and 29 CFR 1910.1200 required a labeled container. OAR 817-060-0010(1) and 817-010-0040(1) required procedures that protect skin and clothes, including a neck barrier under a common cape. OAR 817-010-0060(1) required chemical waste closed at the end of the service and fire-retardant at close. OAR 817-060-0030(3)(d) prohibited the open flame at the workstation during a chemical service. The mug was convenient. It was not the rule.