Study guide

Natural stone and rigid or flexible setting

Oregon Landscape Contractor License Study Guide 2026

Track your progress as you read

Finished sections get a check mark.

1 1. Licensing and business: 1

Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility

2 2. Licensing and business: 2

Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens

3 3. Licensing and business: 3

LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing

4 4. Site safety and utilities

Excavation safety and hazard controls Oregon 811 notices and utility protection

5 5. Soil science and site preparation: 1

Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity

6 6. Soil science and site preparation: 2

Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds

7 7. Plants, turf, and establishment: 1

Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions

8 8. Plants, turf, and establishment: 2

Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth

9 9. Plants, turf, and establishment: 3

Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations

10 10. Plants, turf, and establishment: 4

Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials

11 11. Paving and concrete: 1

Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout

12 12. Paving and concrete: 2

Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing

13 13. Paving and concrete: 3

Concrete joints and curing

14 14. Walls and exterior structures: 1

Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings

15 15. Walls and exterior structures: 2

Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure

16 16. Walls and exterior structures: 3

Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions

17 17. Walls and exterior structures: 4

Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality

18 18. Design, grading, and drainage: 1

Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures

19 19. Design, grading, and drainage: 2

Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall

20 20. Design, grading, and drainage: 3

Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets

21 21. Design, grading, and drainage: 4

Bioretention sizing, media, and plants Swales and current DEQ erosion controls

22 22. Irrigation design and operation: 1

Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting

23 23. Irrigation design and operation: 2

Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage

24 24. Irrigation design and operation: 3

Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves

25 25. Irrigation design and operation: 4

Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions

26 26. Irrigation design and operation: 5

Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup

27 27. Backflow and potable protection: 1

Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies

28 28. Backflow and potable protection: 2

Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports

Natural stone and rigid or flexible setting

Key Takeaways Explain This Topic AI

Select stone for strength, weather exposure, texture, and support.

Open joints do not make the entire foundation fully permeable.

Mortar compressive strength alone does not establish a suitable paving bond.

Last updated: October 2026

Note

Select stone and its support for exposure and loads. Concrete performance depends on approved mixture, foundation, reinforcement, drainage, finishing, joints, and curing. Typical dimensions are examples subject to the project design and product requirements.

Natural Stone Petrography, Textures, and Thickness Criteria

Natural flagstone encompasses broad, flat quarried stone slabs derived from sedimentary, metamorphic, and igneous rock formations. Understanding the geological properties of stone is essential for selecting appropriate materials that withstand Oregon's wet coastal and valley winters and inland freezing cycles.

Natural stone properties

Sandstone, basalt, slate, and other natural stones differ in bedding planes, absorption, strength, texture, and weathering resistance. Do not assume all basalt is nonporous or all sandstone performs alike. Select material rated for the exposure and intended installation, and inspect individual pieces for cracks, delamination, inconsistent thickness, and slippery surfaces.

Freeze-thaw durability matters when absorbed water freezes. Texture affects traction when wet, while thickness and support affect bending and breakage. Obtain supplier information and a sample installation where appearance or performance is uncertain. Natural variation requires layout judgment rather than treating every stone as an identical manufactured unit.

Thickness Standards by Installation Method

Installation System Sub-Base Structure Illustrative Flagstone Thickness Critical Engineering Rationale

Dry-Laid (Flexible) Compacted aggregate base (4"–6") + coarse sand or decomposed granite bed (1"–1.5") 1-1/2" to 2.0" (38 to 50 mm) Actual stone strength, thickness, dimensions, and support must suit the loads.

Wet-Laid / Mortared (Rigid) Reinforced concrete slab footing (3"–4") + Type M or S mortar setting bed (1/2"–1") 3/4" to 1-1/4" (19 to 32 mm) Structural loads are fully supported by the underlying reinforced concrete slab; thinner stone reduces dead load and eases level alignment.

Dry-Laid vs. Wet-Laid (Mortared) Stone Systems

Landscape contractors must evaluate site drainage, soil stability, architectural style, and client budget when selecting between dry-laid flexible and wet-laid mortared stone paving.

Dry-Laid (Flexible) Stone Construction

Foundation: 4 to 6 inches of compacted ODOT 3/4"-0 aggregate base over a woven geotextile fabric and non-yielding subgrade.

Setting Bed: 1.0 to 1-1/2 inches of uncompacted coarse concrete sand (ASTM C33) or compacted decomposed granite (DG).

Fitting and Setting: Irregular flagstone pieces are dry-fitted puzzle-style. Each stone is individually bedded and tapped level using a heavy rubber dead-blow mallet. Thicker stones are dug into the bedding sand, while thinner stones are packed underneath to maintain a flat surface plane without trip hazards.

Joint Finishing: Joints (typically 1/2 inch to 1-1/2 inches wide) are swept full of dry ASTM C144 masonry sand, polymeric flagstone dust, crushed stone screenings, or planted with walkable groundcovers (e.g., creeping thyme, Scotch moss).

Advantages: joint infiltration varies with the complete foundation and soils, accommodates minor frost movement without cracking, simple to repair or re-level, and lower installation cost.

Mortared stone construction

Use an approved rigid substrate, drainage, joints, and setting system for the selected stone and exposure. Slab thickness, reinforcement, cover, and base come from the design. Support reinforcing at the intended elevation rather than place it loose on the ground.

Mortar and bonding products must be compatible with the stone, substrate, moisture, and freeze-thaw exposure. ASTM C270 mortar classifications include Type M at 2,500 psi, Type S at 1,800 psi, and Type N at 750 psi minimum compressive strength under the prescribed tests. These values are not flexural strengths and do not by themselves determine bond or approve a paving installation. Follow the specified setting system rather than declare one universal mortar choice.

Clean bonding surfaces, provide the specified coverage and bond coat, and avoid voids that collect water or leave the stone unsupported. Back-buttering requirements depend on the system. Carry designed movement joints through the finish and provide the approved drainage at adjoining walls and borders. One weep-tube spacing is not valid for every mortared assembly.

For an irregular stone, verify contact and finished plane before the bed hardens. A corner supported only by a small mortar mound can crack or rock later. Select pieces and adjust the bed within the system's limits, preserving drainage and joint width. Do not thicken a bond product beyond its rating to compensate for an incorrectly built substrate.

Application check

A stone that rocks during dry fitting needs support corrected before jointing. Joint fill is not a structural shim. Check thickness variation, contact, edge restraint, and the designed plane. For mortared work, confirm the actual setting product and bond coverage rather than treat the mortar strength number as the entire installation specification. Record any material substitution before it changes the accepted appearance or performance.

Clay brick paving

Use brick intended for paving and the exposure, not an unverified facing brick chosen only for color. Check the supplier's durability, strength, dimensions, and setting instructions. Clay units can differ from concrete pavers in size tolerance and edge geometry; confirm the actual joint and laying pattern with a sample panel. In flexible work, the approved base, setting bed, joint material, and edge restraint function together. In rigid work, bond coverage, drainage, and movement joints must remain compatible with the substrate.

Inspect cut units for cracking and preserve the design's minimum piece size at edges. Dry-lay enough of the pattern to identify alignment and joint-width problems before setting a whole area. A running bond, basket weave, and herringbone use different arrangements; verify that the selected unit dimensions support the intended pattern without forcing joints shut.