Study guide
Lumber dimensions, grades, fasteners, and finishing
Oregon Landscape Contractor License Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 1. Licensing and business: 1
Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility
2 2. Licensing and business: 2
Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens
3 3. Licensing and business: 3
LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing
4 4. Site safety and utilities
Excavation safety and hazard controls Oregon 811 notices and utility protection
5 5. Soil science and site preparation: 1
Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity
6 6. Soil science and site preparation: 2
Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds
7 7. Plants, turf, and establishment: 1
Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions
8 8. Plants, turf, and establishment: 2
Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth
9 9. Plants, turf, and establishment: 3
Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations
10 10. Plants, turf, and establishment: 4
Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials
11 11. Paving and concrete: 1
Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout
12 12. Paving and concrete: 2
Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing
13 13. Paving and concrete: 3
Concrete joints and curing
14 14. Walls and exterior structures: 1
Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings
15 15. Walls and exterior structures: 2
Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure
16 16. Walls and exterior structures: 3
Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions
17 17. Walls and exterior structures: 4
Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality
18 18. Design, grading, and drainage: 1
Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures
19 19. Design, grading, and drainage: 2
Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall
20 20. Design, grading, and drainage: 3
Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets
21 21. Design, grading, and drainage: 4
Bioretention sizing, media, and plants Swales and current DEQ erosion controls
22 22. Irrigation design and operation: 1
Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting
23 23. Irrigation design and operation: 2
Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage
24 24. Irrigation design and operation: 3
Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves
25 25. Irrigation design and operation: 4
Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions
26 26. Irrigation design and operation: 5
Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup
27 27. Backflow and potable protection: 1
Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies
28 28. Backflow and potable protection: 2
Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports
Lumber dimensions, grades, fasteners, and finishing
Key Takeaways Explain This Topic AI
Nominal lumber size differs from actual dimensions.
Species, grade, span, treatment, and connection design affect structural suitability.
Fasteners and coatings must be compatible with wood preservatives and outdoor exposure.
Last updated: October 2026
Read the material specification
Lumber is specified by nominal size, actual dimensions, species or species group, grade, moisture condition, treatment, and sometimes appearance. A nominal two-by-four commonly measures one and one-half by three and one-half inches when surfaced dry. A two-by-six commonly measures one and one-half by five and one-half. Do not calculate a connection, deck gap, or clear opening from nominal dimensions without checking the actual product.
Lengths are generally ordered in feet, while cross-sections use inches. Board feet measure lumber volume: thickness in inches times width in inches times length in feet divided by twelve, using the required nominal or stated basis. A nominal two-by-six twelve feet long is twelve board feet under the nominal formula. Board feet are not square feet of installed deck coverage; a decking takeoff needs actual face width and gaps.
A grade stamp identifies grading agency, species group, grade, and other required information. Structural grades account for strength-relevant characteristics such as knots and grain slope. Appearance grades do not automatically establish a structural span capacity. Do not substitute a visually attractive board for a specified structural grade without confirming equivalence.
Species, moisture, and treatment
Different species groups have different structural properties, decay resistance, and fastener behavior. Span tables require the stated species, grade, member size, spacing, load, and use. A joist suitable for one span is not automatically suitable as a beam or cantilever. Check the exact table and its limits instead of using a remembered “two-by-eight spans twelve feet” rule.
Moisture affects shrinkage, movement, finishing, and fastener performance. Wet treated lumber may shrink as it dries, changing deck gaps and bolt tightness. Naturally durable heartwood can resist decay, while sapwood of the same species may not. “Cedar” without species and grade is an incomplete structural specification.
Use an appropriate treatment category for exposure. Above-ground, ground-contact, and more demanding structural ground-contact uses differ. Read the treatment tag, preservative, retention, use category, and manufacturer instructions. Cutting exposes untreated interior wood, so apply the recommended end-cut treatment. Do not assume a surface stain replaces pressure treatment for a buried post.
Connections transfer load
Nails, screws, bolts, structural screws, straps, hangers, and post bases serve different purposes. A connector's listed capacity depends on its exact fasteners, count, penetration, member geometry, and installation. Drywall screws or generic deck screws cannot replace specified structural connector nails simply because they fit the hole. Use the listed fastener and avoid unapproved substitutions.
Edge and end distances reduce splitting and withdrawal risk. Predrilling can be required for large fasteners or dense material. Tighten bolts correctly without crushing fibers, use specified washers, and maintain required bearing and support. A connection can fail even when both lumber members are adequately sized. Toenails may provide useful capacity in an approved detail, but do not replace a required hanger or positive structural connection.
Modern copper-based preservatives can corrode incompatible metals. Choose coatings or stainless materials according to the wood-treatment and hardware manufacturers and exposure. Coastal conditions can require more resistant materials, but there is no generic ten-mile coastal boundary that resolves every connection. Mixing dissimilar metals can also cause galvanic corrosion. Verify aluminum contact and flashing compatibility with treated lumber.
Finishing fences, gates, and arbors
Paint forms a coating; stains and water repellents have different penetration and maintenance characteristics. Clean and prepare the surface, allow the appropriate moisture condition, and follow the product's temperature and curing instructions. Coating wet treated lumber too soon can lead to poor adhesion. End grain absorbs water readily, so protect it according to the system's detail and finish recommendations.
Avoid water traps at horizontal ledges and closely fitted joints. Shape or cap exposed post tops as specified, keep connections inspectable, and provide drainage without compromising required bearing. A finish cannot repair a structural split, insufficient embedment, or an undersized gate hinge. Diagnose the cause before applying another coat.
At acceptance, verify actual dimensions, grade and treatment records, connector installation, and intended clearances. Explain the finish's maintenance interval as a product-dependent expectation rather than a guaranteed number of years. Record substitutions and preserve labels or delivery information so future repairs use compatible material. Wood selection, structural layout, connection design, and moisture management must work together.
Field application
For a clear gate opening, count actual post and hinge dimensions as well as panel width. Two nominal four-by-four posts commonly measure three and one-half inches each, so they occupy seven inches across the assembly rather than eight. Hardware offsets and gate clearance add other allowances. A takeoff based solely on nominal sizes can produce the wrong opening even when the stock order is correct. Lay out the actual connection before cutting and confirm the specified gate can swing without striking the ground.
Reference table
- Specification item What it establishes
- Nominal and actual size Purchasing description versus built dimensions
- Species and grade Inputs to structural properties and span tables
- Treatment category Appropriate exposure and use
- Connector listing Required fastener, count, geometry, and capacity