Study guide

Water features, pumps, liners, and water quality

Oregon Landscape Contractor License Study Guide 2026

Track your progress as you read

Finished sections get a check mark.

1 1. Licensing and business: 1

Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility

2 2. Licensing and business: 2

Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens

3 3. Licensing and business: 3

LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing

4 4. Site safety and utilities

Excavation safety and hazard controls Oregon 811 notices and utility protection

5 5. Soil science and site preparation: 1

Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity

6 6. Soil science and site preparation: 2

Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds

7 7. Plants, turf, and establishment: 1

Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions

8 8. Plants, turf, and establishment: 2

Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth

9 9. Plants, turf, and establishment: 3

Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations

10 10. Plants, turf, and establishment: 4

Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials

11 11. Paving and concrete: 1

Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout

12 12. Paving and concrete: 2

Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing

13 13. Paving and concrete: 3

Concrete joints and curing

14 14. Walls and exterior structures: 1

Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings

15 15. Walls and exterior structures: 2

Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure

16 16. Walls and exterior structures: 3

Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions

17 17. Walls and exterior structures: 4

Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality

18 18. Design, grading, and drainage: 1

Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures

19 19. Design, grading, and drainage: 2

Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall

20 20. Design, grading, and drainage: 3

Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets

21 21. Design, grading, and drainage: 4

Bioretention sizing, media, and plants Swales and current DEQ erosion controls

22 22. Irrigation design and operation: 1

Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting

23 23. Irrigation design and operation: 2

Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage

24 24. Irrigation design and operation: 3

Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves

25 25. Irrigation design and operation: 4

Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions

26 26. Irrigation design and operation: 5

Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup

27 27. Backflow and potable protection: 1

Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies

28 28. Backflow and potable protection: 2

Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports

Water features, pumps, liners, and water quality

Key Takeaways Explain This Topic AI

Select a pump from required flow at total dynamic head, not its free-discharge label.

Water-feature electrical supply and potable makeup require appropriate licensed work and protection.

Circulation, filtration, debris removal, and safe overflow address different operating needs.

Last updated: October 2026

Define the feature and operating conditions

A pond, recirculating fountain, waterfall, and pondless basin have different storage, pump, lining, and maintenance requirements. Define appearance, sound, operating hours, water depth, plants or fish, access, and expected evaporation. Determine whether pool or barrier rules apply to the proposed use and geometry. Calling a deep basin a landscape ornament does not remove a safety or permit requirement.

Locate utilities and assess soils before excavation. Groundwater or poor support can lift, deform, or settle a basin. Protect nearby foundations and trees, and provide an approved overflow route. Keep maintenance access to pumps, filters, valves, and electrical disconnects. A concealed pump that requires dismantling the waterfall for cleaning is an avoidable design problem.

Select liner or structural materials compatible with sunlight, temperature, water chemistry, and the intended plants or animals. Flexible liners require prepared support and protection from sharp stones and roots. Rigid or concrete structures need their own foundation, joints, curing, and waterproofing. A mortar bond alone does not make a feature watertight.

Water volume and storage

For a rectangular basin, length times width times average water depth gives cubic feet; multiply by about 7.48 to convert to gallons. An eight-by-six-foot basin with average depth two feet contains ninety-six cubic feet, or about 718 gallons. Irregular profiles require a more careful area and depth estimate. Do not calculate from the outside dimensions of thick walls.

A recirculating waterfall needs enough basin storage for water that drains back when the pump stops and enough operating water to keep the pump intake submerged. Account for stream channels, pipe drainback, splash, and evaporation. An inadequately sized pondless reservoir can overflow at shutdown and run dry after restart. Inspect the entire cycle, not only a photograph taken while running.

Pump selection and piping

Pump labels often give maximum flow at very low or zero head. Actual flow depends on total dynamic head: elevation lift plus friction and component losses at the operating flow. Read the pump curve and identify the operating point. If a waterfall needs thirty gpm at eight feet of total head, select a pump whose curve supplies that duty, not one labeled thirty gpm at free discharge.

Separate static lift from pipe length. A ten-foot horizontal run does not create ten feet of elevation head, but it adds friction. Larger pipe can reduce friction; elbows, filters, and valves add losses. Use compatible pressure-rated pipe and accessible fittings. A clogged filter shifts the operating point and can reduce the waterfall even when the pump motor still runs.

Avoid starvation, cavitation, and dry running by following intake-submergence and suction requirements. Use the manufacturer's approved pump orientation and protection. An intake screen prevents large debris but can clog; preserve access for cleaning. Isolate equipment safely before servicing rather than reach into water with energized components.

Electrical and potable-water protection

Use equipment listed for its location, including submersible ratings where applicable. Electrical branch circuits, receptacles, grounding/bonding, ground-fault protection, and required disconnects must meet applicable electrical requirements and be installed within the proper licensed scope. A low-voltage landscape-lighting credential does not authorize every underwater fixture or pump supply connection.

Potable makeup is a potential cross-connection. Use the required approved separation or backflow protection selected by the authority for the actual hazard. A hose submerged in the pond creates a direct exposure even when used only temporarily. A check valve sold with a fountain pump is not automatically approved potable-water protection. Keep nonpotable recirculating piping identifiable and separate.

Water clarity and long-term care

Mechanical filtration removes particles; biological filtration supports processes that transform waste; circulation helps move water through the intended system. Each addresses a different issue. Clear-looking water is not proof that it is safe to drink. Algae can reflect nutrient load, sunlight, stagnant areas, and maintenance conditions; adding a chemical without diagnosis may not correct the cause.

Remove leaves and sediment, maintain filters, and balance plant or fish loading with the system's capacity. Follow product labels for any treatment and applicable pesticide credentials. Do not discharge chemically treated or sediment-laden water to a storm drain without an approved disposal method. Plan winter operation or shutdown for the climate and equipment.

Commission flow, leaks, pump cycling, overflow, shutdown drainback, and makeup controls. Give the owner a maintenance schedule, isolation instructions, and signs of trouble, such as unusual noise, low water, reduced flow, or repeated electrical trips. A successful feature must remain safe, serviceable, and hydraulically stable after the installer leaves.

Reference table

  • Feature component Function or check
  • Basin Volume, drainback storage, support, safe overflow
  • Pump Required flow at total dynamic head
  • Liner Compatibility, support, protection, watertight details
  • Filter Particle or biological management for actual loading
  • Makeup Approved potable separation and source arrangement