Study guide
Sprinkler types, pressure, and coverage
Oregon Landscape Contractor License Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 1. Licensing and business: 1
Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility
2 2. Licensing and business: 2
Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens
3 3. Licensing and business: 3
LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing
4 4. Site safety and utilities
Excavation safety and hazard controls Oregon 811 notices and utility protection
5 5. Soil science and site preparation: 1
Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity
6 6. Soil science and site preparation: 2
Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds
7 7. Plants, turf, and establishment: 1
Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions
8 8. Plants, turf, and establishment: 2
Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth
9 9. Plants, turf, and establishment: 3
Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations
10 10. Plants, turf, and establishment: 4
Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials
11 11. Paving and concrete: 1
Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout
12 12. Paving and concrete: 2
Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing
13 13. Paving and concrete: 3
Concrete joints and curing
14 14. Walls and exterior structures: 1
Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings
15 15. Walls and exterior structures: 2
Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure
16 16. Walls and exterior structures: 3
Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions
17 17. Walls and exterior structures: 4
Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality
18 18. Design, grading, and drainage: 1
Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures
19 19. Design, grading, and drainage: 2
Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall
20 20. Design, grading, and drainage: 3
Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets
21 21. Design, grading, and drainage: 4
Bioretention sizing, media, and plants Swales and current DEQ erosion controls
22 22. Irrigation design and operation: 1
Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting
23 23. Irrigation design and operation: 2
Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage
24 24. Irrigation design and operation: 3
Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves
25 25. Irrigation design and operation: 4
Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions
26 26. Irrigation design and operation: 5
Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup
27 27. Backflow and potable protection: 1
Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies
28 28. Backflow and potable protection: 2
Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports
Sprinkler types, pressure, and coverage
Key Takeaways Explain This Topic AI
Select devices from actual performance charts.
Drip requires compatible regulation and filtration.
Verify head spacing at operating pressure and actual exposure.
Last updated: October 2026
Select equipment from its operating data
Sprinkler type gives a useful starting category, but the actual nozzle, body, arc, pressure, and spacing establish performance. Read the manufacturer's chart at the intended operating pressure and calculate zone demand. A catalog's maximum radius at high pressure is not the radius available at a low-pressure corner of the site. Identify the controlling outlet and allow for elevation and component losses before choosing equipment.
Radius is the distance from a sprinkler to the intended edge of its throw; diameter is twice radius for a full circle. Confusing the two doubles spacing and can leave dry gaps. Check whether the chart reports full-circle or part-circle flow and whether the published precipitation assumes square or triangular spacing. A flow number in gpm is not itself an application depth in inches per hour.
Fixed spray nozzles
A fixed spray nozzle emits a fan or shaped pattern without a gear-driven rotating stream. Quarter, half, full, strip, and adjustable patterns serve different boundaries. Short throws fit small turf panels, but the pattern must stay within the intended landscape instead of repeatedly spraying a sidewalk or wall.
For a concrete product example, Rain Bird's MPR spray family lists fifteen-to-thirty-psi operation and thirty psi as optimum. This is that family's performance information, not the pressure requirement of every spray nozzle. Rain Bird MPR specifications provide the model and pattern data.
Excess pressure can create fine mist and distort coverage; inadequate pressure can reduce throw or prevent normal operation. Use the appropriate regulated body or upstream control when required by the design and applicable product rules. The regulator must have enough inlet pressure to work. A thirty-psi regulator cannot create thirty psi when its inlet supply falls below the needed pressure.
Sprays often have relatively high precipitation. Compare calculated or measured rate with soil intake, slope, and root-zone storage. Where runoff begins before the intended depth is delivered, cycle-and-soak scheduling or a suitable lower-rate design may help. Do not assume every clay site has one infiltration rate or that short cycles alone correct poor drainage.
Rotary multi-stream nozzles
Rotary nozzles produce moving streams and can fit compatible pop-up bodies. Their rate differs among families. Hunter's standard MP Rotators are approximately 0.4 inch per hour, while the MP800 family is approximately 0.8. Hunter recommends forty-psi operation for nominal radius settings. Those examples explain why two rotary products are not automatically interchangeable on one zone. Hunter nozzle support identifies family-specific requirements.
A lower application rate can fit some tight soils and reduce required simultaneous flow, but pressure must still support radius and rotation. A retrofit is not complete merely because new nozzles screw into old bodies. Check spacing, matched flow, body height, obstruction, and required runtime. Distribution uniformity comes from the complete installation and operating conditions; a nozzle category does not guarantee a particular field DU value.
Gear-driven rotors
Rotors use a water-powered mechanism to sweep a stream through an arc. They commonly serve larger turf areas, with model-specific radii, trajectories, and nozzle choices. Some products suit shorter ranges, so “all rotors need a twenty-foot-wide area” is an unreliable selection rule.
Hunter's PGP-ADJ example has a recommended pressure range of twenty-five to seventy psi and an operating range of twenty to one hundred. It does not establish a universal forty-psi minimum for every rotor. Use the selected nozzle's performance chart within the product range. Hunter PGP-ADJ specifications .
Match discharge to arc where the layout requires it. A half-circle rotor covering half the area of a comparable full-circle needs compatible application, not necessarily the same nozzle flow. Check the manufacturer's matched options and the design method before mixing arcs. Protect nearby paths, structures, and plants from overspray, and avoid obstructing streams with mature vegetation.
Drip and micro-irrigation
Point-source emitters and inline drip apply water to a defined root-zone area. Their individual discharge is commonly given in gallons per hour. Convert total simultaneous gph to gpm for source and pipe calculations. The required filtration, pressure, tubing length, and emitter spacing come from the product and water source, not one universal mesh or pressure value. For example, some Rain Bird dripline specifies 120-mesh filtration, illustrating why a generic 150–200-mesh mandate is incorrect. Rain Bird dripline specifications .
Inspect the wetting pattern, not only the fact that water exits an emitter. Soil, spacing, roots, and placement determine whether enough of the root system receives water. Provide suitable filtration, regulation, flush points, and service access. Pressure-compensating emitters still have an approved operating range and cannot compensate for a blocked filter or pressure outside that range.
Coverage and commissioning
Head-to-head sprinkler spacing commonly places adjacent heads about one operating radius apart. Overlap addresses uneven distribution from individual heads; it is not proof of uniform application. Wind, pressure, arc adjustment, slope, and obstacles affect the final result. Use the manufacturer's spacing guidance and a catch-can audit when appropriate.
- Equipment Primary selection check Field verification
- Fixed spray Pattern, pressure, radius, precipitation Overspray, misting, dry gaps, runoff
- Rotary nozzle Exact family rate and pressure Rotation, radius, compatible zone application
- Rotor Nozzle flow, arc, pressure, spacing Stream clearance and distribution
- Drip Emitter demand, filtration, pressure, wetted area Flow, leaks, flushing, root-zone moisture
Record installed models and nozzle settings so future repairs preserve the design. Replacing one head with a higher-flow nozzle can change both distribution and hydraulic demand throughout the zone.