Study guide
Pressure, elevation, friction, and budgets
Oregon Landscape Contractor License Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 1. Licensing and business: 1
Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility
2 2. Licensing and business: 2
Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens
3 3. Licensing and business: 3
LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing
4 4. Site safety and utilities
Excavation safety and hazard controls Oregon 811 notices and utility protection
5 5. Soil science and site preparation: 1
Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity
6 6. Soil science and site preparation: 2
Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds
7 7. Plants, turf, and establishment: 1
Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions
8 8. Plants, turf, and establishment: 2
Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth
9 9. Plants, turf, and establishment: 3
Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations
10 10. Plants, turf, and establishment: 4
Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials
11 11. Paving and concrete: 1
Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout
12 12. Paving and concrete: 2
Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing
13 13. Paving and concrete: 3
Concrete joints and curing
14 14. Walls and exterior structures: 1
Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings
15 15. Walls and exterior structures: 2
Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure
16 16. Walls and exterior structures: 3
Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions
17 17. Walls and exterior structures: 4
Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality
18 18. Design, grading, and drainage: 1
Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures
19 19. Design, grading, and drainage: 2
Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall
20 20. Design, grading, and drainage: 3
Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets
21 21. Design, grading, and drainage: 4
Bioretention sizing, media, and plants Swales and current DEQ erosion controls
22 22. Irrigation design and operation: 1
Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting
23 23. Irrigation design and operation: 2
Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage
24 24. Irrigation design and operation: 3
Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves
25 25. Irrigation design and operation: 4
Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions
26 26. Irrigation design and operation: 5
Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup
27 27. Backflow and potable protection: 1
Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies
28 28. Backflow and potable protection: 2
Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports
Pressure, elevation, friction, and budgets
Key Takeaways Explain This Topic AI
Use working pressure at the design flow.
Elevation changes pressure about 0.433 psi per vertical foot.
Friction and surge need separate checks.
The worked example leaves 34.59 psi after 30.41 psi of losses.
Last updated: October 2026
Note
Design from available pressure at the required flow, account for elevation and component losses, and verify the remaining nozzle pressure. A customary five-ft/sec velocity recommendation is a design check, not a guarantee that water hammer cannot occur.
Fundamental Hydraulic Principles: Pressure, Head, and Elevation
Hydraulics in landscape contracting is the study of water at rest and in motion through pipes, valves, and emission devices. For an irrigation system to function properly, water must arrive at the sprinkler head with sufficient energy to throw its designed radius and atomize water droplets uniformly across the target landscape area.
Units of Hydraulic Measure
Irrigation hydraulics relies on two fundamental units of pressure measurement:
Pounds per Square Inch (PSI): The standard imperial unit of pressure representing the force exerted by water against one square inch of container surface area.
Feet of Head (ft of head): The vertical height of a column of water that exerts a specific pressure at its base due to gravity.
Because water has a constant density of approximately 62.4 lbs/cu ft 62.4\text{ lbs/cu ft} 62.4 lbs/cu ft ( 8.34 lbs/gallon 8.34\text{ lbs/gallon} 8.34 lbs/gallon ), the mathematical relationship between PSI and feet of head is fixed: Pressure (PSI) = Head (feet) × 0.433 \text{Pressure (PSI)} = \text{Head (feet)} \times 0.433 Pressure (PSI) = Head (feet) × 0.433 Head (feet) = Pressure (PSI) × 2.31 \text{Head (feet)} = \text{Pressure (PSI)} \times 2.31 Head (feet) = Pressure (PSI) × 2.31
Elevation Head Gain and Loss
Topography exerts a direct physical effect on irrigation system pressure. As water travels uphill against gravity, it expends potential energy, resulting in a pressure loss of 0.433 PSI per vertical foot of elevation rise (or 1.0 PSI lost for every 2.31 feet of rise). Conversely, when water flows downhill, gravity acts upon the water column, producing a pressure gain of 0.433 PSI per vertical foot of elevation fall .
Uphill Elevation Change (Pressure Loss): Δ P elevation = − 0.433 × Rise in Feet \Delta P_{\text{elevation}} = -0.433 \times \text{Rise in Feet} Δ P elevation = − 0.433 × Rise in Feet
Example: A lawn terrace located 24 vertical feet above the water meter will lose 24 × 0.433 = 10.39 PSI 24 \times 0.433 = 10.39\text{ PSI} 24 × 0.433 = 10.39 PSI of static and dynamic pressure before water ever exits a nozzle.
Downhill Elevation Change (Pressure Gain): Δ P elevation = + 0.433 × Drop in Feet \Delta P_{\text{elevation}} = +0.433 \times \text{Drop in Feet} Δ P elevation = + 0.433 × Drop in Feet
Example: A lower garden bed located 18 vertical feet below the meter gains 18 × 0.433 = 7.79 PSI 18 \times 0.433 = 7.79\text{ PSI} 18 × 0.433 = 7.79 PSI . In lower zones, excess pressure must often be managed with pressure-regulating valves (PRVs) to prevent misting.
Static and working pressure
Static pressure is measured with no water flowing at the test point. Working pressure is the pressure measured while the specified flow passes through the system. It is still a pressure reading, not simply “kinetic pressure.” Flow creates losses in service piping, the meter, assemblies, valves, and distribution piping. Supply pressure can also vary by time, elevation, pumping, and concurrent demand.
A static reading of 65 psi does not establish that 65 psi is available while a fifteen-gpm zone operates. Measure the flow-pressure relationship at the appropriate source point and record what upstream losses it already includes. Avoid subtracting a meter loss twice when the measured working pressure was taken downstream of the meter. Use the limiting operating condition, not an unusually favorable isolated reading.
Water Supply Evaluation: Meter Sizing and Safe Flow Limits
Before designing an irrigation system, the contractor must determine the physical constraints of the water source: municipal meter size, service line size and material, and static water pressure.
Measuring Static Pressure
Static pressure must be verified on-site using a calibrated liquid-filled pressure gauge attached to an unregulated exterior hose bibb or service connection upstream of any residential pressure-reducing valves. Testing should ideally occur during peak municipal consumption hours (typically early morning or late afternoon) to record the worst-case static pressure baseline.
Establish the allowable design flow
Determine the actual meter model and rating, water supplier's permitted flow, service-line size and condition, and available working pressure. Published design manuals may use a conservative fraction of a meter's maximum rating, but “seventy-five percent of maximum continuous flow” is not a universal Oregon legal rule. A bucket test at an unrestricted hose bibb also does not prove that the same flow is available at the needed operating pressure.
For a problem that explicitly permits fifteen gpm at the connection, design the simultaneous demand at or below fifteen gpm and verify the pressure budget. If another fixture must operate concurrently, reserve the stated domestic demand. Check pipe velocity and friction separately. Meter capacity, pressure, and service-line capacity are related constraints, not interchangeable measurements.
Friction Loss Mechanics & The Hazen-Williams Equation
When water flows through a pipe, viscosity and turbulence cause energy loss. Water molecules rub against the pipe wall and collide with one another, converting hydraulic pressure into heat. This pressure drop is termed friction loss .
Factors Influencing Pipe Friction Loss
Internal Pipe Diameter ( d d d ): Friction loss is inversely proportional to internal diameter raised to approximately the fifth power ( 1 / d 4.87 1/d^{4.87} 1/ d 4.87 ). Doubling the pipe diameter reduces friction loss by more than 85% for a given flow rate.
Flow Rate / Velocity ( V V V ): Friction loss increases nonlinearly as flow velocity increases. Doubling flow rate increases about 3.6 times under the Hazen-Williams relationship friction loss.
Pipe Length ( L L L ): Friction loss is directly linear with distance; 200 feet of pipe generates exactly twice the friction loss of 100 feet of identical pipe at the same flow.
Interior Wall Roughness (C-Factor): The smoother the pipe interior, the less turbulence created. The Hazen-Williams roughness coefficient ( C C C ) measures internal smoothness:
- Piping Material Hazen-Williams C-Factor Interior Characteristics
- PVC Pipe (Sch 40, Class 200) 150 Extremely smooth plastic; lowest friction loss; retains smoothness over time
- Polyethylene (PE) Pipe 140 Smooth flexible plastic; low friction; slight drag from insert fittings
- Copper Tubing (Type K & L) 140 Smooth drawn metal; low friction loss
- New Galvanized Steel 120 Moderate roughness; factory zinc coating
- Aged Galvanized Iron 100 High roughness; subject to internal corrosion, rust nodules, and mineral scaling
Note
A higher C-factor indicates a smoother pipe surface, which results in lower friction loss. PVC ( C = 150 C=150 C = 150 ) exhibits substantially less pressure drop per 100 feet than old galvanized steel pipe ( C = 100 C=100 C = 100 ).
Fitting Losses and Equivalent Lengths
Elbows, tees, valves, and couplings change flow direction or passage geometry, adding localized losses. In hydraulic calculations, fitting friction is incorporated either by adding an empirical percentage (typically 10% of total pipe friction) or by using equivalent length tables where each fitting is converted into an equivalent length of straight pipe (e.g., a 1-inch standard 90° PVC elbow generates friction loss equivalent to approximately 2.5 feet of straight 1-inch PVC pipe).
Velocity and surge
Water hammer is a pressure transient caused by a rapid change in flow, such as a quickly closing valve. Pipe elasticity, length, wave speed, flow velocity, and valve behavior affect the surge. Air pockets and abrupt filling can also cause damaging conditions.
A common irrigation recommendation limits velocity to about five feet per second, but meeting that number does not eliminate all surge risk or establish a universal code maximum. Calculate with internal diameter, choose suitable valves and pressure ratings, fill slowly, and follow the design's surge controls. Pressure ratings must account for temperature and transient loading rather than only normal operating pressure.
Worked pressure budget with explicit assumptions
Assume the verified source pressure at the design flow is 65 psi before the listed components. Manufacturer data for this example give meter loss 3.20 psi, service loss 2.36 psi, backflow loss 7.50 psi, mainline loss 5.76 psi, valve loss 3.10 psi, and lateral loss 3.04 psi. The controlling head is ten feet higher, costing 10 ( 0.433 ) = 4.33 10(0.433)=4.33 10 ( 0.433 ) = 4.33 psi. Assume a fitting allowance equal to ten percent of the three pipe losses: 0.10 ( 2.36 + 5.76 + 3.04 ) = 1.116 0.10(2.36+5.76+3.04)=1.116 0.10 ( 2.36 + 5.76 + 3.04 ) = 1.116 , or 1.12 psi.
Total loss is 3.20 + 2.36 + 7.50 + 5.76 + 3.10 + 3.04 + 1.12 + 4.33 = 30.41 3.20+2.36+7.50+5.76+3.10+3.04+1.12+4.33=30.41 3.20 + 2.36 + 7.50 + 5.76 + 3.10 + 3.04 + 1.12 + 4.33 = 30.41 psi. Remaining pressure is 65 − 30.41 = 34.59 65-30.41=34.59 65 − 30.41 = 34.59 psi. If the selected nozzle requires 30 psi, the example has 4.59 psi of remaining allowance. If it needs 40 psi, the design fails and must change flow, pipe sizes, device selection, or supply assumptions.
These are supplied illustrative component losses, not verified performance of an unnamed valve or assembly. In practice obtain each loss at the actual flow and evaluate the hydraulically controlling path. A nearer but higher head can be more demanding than a farther lower head. A lower zone can need pressure regulation even when the highest zone barely meets its requirement. Rain Bird design manual explains the design sequence.