Study guide
Pipe materials, bore, velocity, and valves
Oregon Landscape Contractor License Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 1. Licensing and business: 1
Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility
2 2. Licensing and business: 2
Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens
3 3. Licensing and business: 3
LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing
4 4. Site safety and utilities
Excavation safety and hazard controls Oregon 811 notices and utility protection
5 5. Soil science and site preparation: 1
Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity
6 6. Soil science and site preparation: 2
Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds
7 7. Plants, turf, and establishment: 1
Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions
8 8. Plants, turf, and establishment: 2
Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth
9 9. Plants, turf, and establishment: 3
Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations
10 10. Plants, turf, and establishment: 4
Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials
11 11. Paving and concrete: 1
Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout
12 12. Paving and concrete: 2
Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing
13 13. Paving and concrete: 3
Concrete joints and curing
14 14. Walls and exterior structures: 1
Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings
15 15. Walls and exterior structures: 2
Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure
16 16. Walls and exterior structures: 3
Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions
17 17. Walls and exterior structures: 4
Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality
18 18. Design, grading, and drainage: 1
Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures
19 19. Design, grading, and drainage: 2
Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall
20 20. Design, grading, and drainage: 3
Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets
21 21. Design, grading, and drainage: 4
Bioretention sizing, media, and plants Swales and current DEQ erosion controls
22 22. Irrigation design and operation: 1
Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting
23 23. Irrigation design and operation: 2
Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage
24 24. Irrigation design and operation: 3
Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves
25 25. Irrigation design and operation: 4
Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions
26 26. Irrigation design and operation: 5
Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup
27 27. Backflow and potable protection: 1
Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies
28 28. Backflow and potable protection: 2
Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports
Pipe materials, bore, velocity, and valves
Key Takeaways Explain This Topic AI
Nominal size differs from actual bore.
Velocity in ft/sec equals 0.408 times gpm divided by inside diameter squared.
At five ft/sec, a 1.189-inch bore carries about 17.33 gpm.
Size each segment from downstream flow and pressure needs.
Last updated: October 2026
Note
Use rated pipe and compatible fittings, calculate with actual bore, and check both friction and velocity. Valves, field wiring, sensors, and controller settings must follow the approved design and product instructions.
Irrigation Piping Materials and Specifications
Selecting the correct piping material depends on operating pressure, burial depth, local soil chemistry, and whether the pipe is under continuous or intermittent pressure:
Schedule 40 PVC (ASTM D1785)
Schedule 40 polyvinyl chloride (PVC) is the standard structural pipe specified for mainline piping under continuous static pressure between the backflow prevention assembly and the electric control valves.
Wall Thickness: Specified by schedule dimensions (wall thickness remains constant for a given nominal size, so pressure rating decreases as pipe diameter increases: 1/2" is rated at 600 PSI, 1" at 450 PSI, 2" at 280 PSI).
Joining Method: Solvent-welded bell or socket fittings using ASTM F656 purple primer and ASTM D2564 medium-bodied PVC solvent cement.
Physical Attributes: High tensile strength and impact resistance; withstands constant municipal line pressure and hydraulic transients.
Class 200 / SDR 21 PVC (ASTM D2241)
Class 200 PVC utilizes a Standard Dimension Ratio (SDR 21), meaning the ratio of outside pipe diameter to wall thickness is fixed at 21:1 across all sizes. As a result, every diameter of Class 200 pipe possesses the identical working pressure rating of 200 PSI .
Primary Application: Lateral piping downstream of electric zone control valves.
Hydraulic Advantage: Because wall thickness is thinner than Schedule 40, the internal diameter (ID) is larger. Consequently, Class 200 pipe carries higher flow rates with significantly less friction loss per 100 feet than Schedule 40.
Limitation: Prohibited under some municipal codes for use as continuous-pressure mainline piping due to lower puncture and shear resistance.
Polyethylene (PE) Pipe (ASTM D2239)
Polyethylene pipe is a flexible, black coil pipe widely used in residential lateral lines throughout cold and rocky Pacific Northwest regions (such as Central Oregon and the Rogue Valley).
Pressure Ratings: SIDR-15 (100 PSI), SIDR-11.5 (125 PSI), or high-density PE (HDPE).
Joining Method: Insert barbed fittings secured with all-stainless steel pinch clamps or worm-gear clamps, or modern compression couplings.
Freeze Resilience: Unlike rigid PVC, which shatters when water freezes and expands, polyethylene pipe can expand slightly without splitting, making it highly resilient in freeze-thaw climates.
Velocity-Based Pipe Sizing Schedules (The 5 FPS Rule)
A common design recommendation checks velocity against about five ft/sec. This is not a universal legal threshold and does not eliminate all water hammer. Also check available nozzle pressure, surge, temperature derating, and the actual component ratings.
Calculate velocity from actual internal diameter
For water in round pipe, v = 0.408 Q / d 2 v=0.408Q/d^2 v = 0.408 Q / d 2 , where v v v is ft/sec, Q Q Q is gpm, and d d d is internal diameter in inches. A nominal one-inch size is not a one-inch internal diameter. The wall series changes the actual bore and therefore both velocity and friction.
- Assumed internal diameter, inches Flow at 5 ft/sec, gpm
- 0.622 4.74
- 0.930 10.60
- 1.189 17.33
- 1.502 27.65
- 1.734 36.85
- 2.149 56.59
- 2.601 82.91
These values are calculated from the supplied diameters, not a universal nominal-size schedule. At fourteen gpm through a 1.189-inch bore, velocity is 0.408 ( 14 ) / 1.189 2 = 4.04 0.408(14)/1.189^2=4.04 0.408 ( 14 ) /1.18 9 2 = 4.04 ft/sec. Friction still needs a separate check; acceptable velocity alone does not establish that enough pressure remains.
Flow decreases along a branching lateral
Sum the demand downstream of each segment. A segment before all heads carries total zone flow; after a branch it carries the remaining demand. At fourteen gpm, a 1.189-inch bore has velocity about 4.04 ft/sec. Whether that size is adequate still depends on length and the pressure budget.
Reduce diameter only when both friction and velocity remain acceptable. A long downstream segment can need a larger bore despite lower flow. Evaluate the controlling head path and use the actual pipe series rather than a rigid nominal-size progression.
Electric Remote Control Valves & Manifold Architecture
Automatic irrigation zones are actuated by remote control valves (typically globe or angle configuration) powered by 24-volt alternating current (24VAC) signals from the central irrigation controller.
Valve Operating Mechanics (Differential Pressure Hydraulics)
An electric control valve is not moved by a mechanical motor; it is operated by hydraulic pressure differential controlled by an electromagnetic solenoid:
Closed Position: Water enters the upper chamber above the flexible rubber diaphragm through a tiny metering bleed hole. Because the surface area of the diaphragm in the upper chamber is greater than the area exposed to inlet pressure below, the downward force exceeds the upward force, pressing the diaphragm firmly against the valve seat.
Opening Sequence: The controller sends 24VAC to the solenoid, creating a magnetic field that retracts an internal stainless steel plunger. This unseats an exhaust port, venting the trapped water from the upper chamber into the downstream lateral. The higher inlet water pressure below pushes the diaphragm upward, opening full flow into the zone.
Closing Sequence: When 24VAC cuts off, a spring pushes the plunger back down over the exhaust port. Water flowing through the metering bleed hole refills the upper chamber, re-establishing downward pressure and smoothly seating the diaphragm.