Study guide

Potable, irrigation, and reclaimed-water piping

Oregon Landscape Contractor License Study Guide 2026

Track your progress as you read

Finished sections get a check mark.

1 1. Licensing and business: 1

Exam structure, reference use, and license routes Oregon jurisdiction, license phases, and eligibility Bonds, insurance, and financial responsibility

2 2. Licensing and business: 2

Employee status, paid work, and payroll calculations Hiring, breaks, sick time, and workplace protections Contracts, cancellation, guarantees, and liens

3 3. Licensing and business: 3

LCP supervision and clear project communication Direct costs and overhead allocation Margin, markup, changes, and job costing

4 4. Site safety and utilities

Excavation safety and hazard controls Oregon 811 notices and utility protection

5 5. Soil science and site preparation: 1

Soil texture, structure, and pore space Density, regional profiles, and soil water Soil pH, diagnosis, and exchange capacity

6 6. Soil science and site preparation: 2

Amendments and fertilizer calculations Compaction, decompaction, and topsoil protection Topsoil placement, finish grades, and weeds

7 7. Plants, turf, and establishment: 1

Planting plans, stock sizes, and quantity takeoffs Botanical identification, plant types, and growth habits Mature size, landscape use, and exposure decisions

8 8. Plants, turf, and establishment: 2

Hardiness, microclimates, and plant names Native plant choices and invasive plants Nursery stock, root flares, and planting depth

9 9. Plants, turf, and establishment: 3

Backfill, staking, and mulch Turf species, mixtures, and site suitability Seed, sod, and establishment calculations

10 10. Plants, turf, and establishment: 4

Pruning and integrated pest management Pest diagnosis, weeds, and pesticide credentials

11 11. Paving and concrete: 1

Pavement foundations, drainage, and excavation Separation fabric, aggregate, and compaction Bedding, restraints, and square layout

12 12. Paving and concrete: 2

Paver laying, cuts, patterns, and joint fill Natural stone and rigid or flexible setting Concrete mixture, placement, and finishing

13 13. Paving and concrete: 3

Concrete joints and curing

14 14. Walls and exterior structures: 1

Segmental wall systems and foundations Wall drainage, backfill, and geogrid Earth pressure, stone walls, and footings

15 15. Walls and exterior structures: 2

Masonry reinforcement, wall permits, and failure Lumber dimensions, grades, fasteners, and finishing Treated lumber and outdoor exposure

16 16. Walls and exterior structures: 3

Wood durability, hardware, and post geometry Fences, decks, ledgers, and arbors Landscape steps, stairs, and safe transitions

17 17. Walls and exterior structures: 4

Low-voltage lighting design, wiring, and commissioning Water features, pumps, liners, and water quality

18 18. Design, grading, and drainage: 1

Landscape design, circulation, and coordinated details Surveying, benchmarks, and elevation checks Planting on roofs, decks, and other structures

19 19. Design, grading, and drainage: 2

Drawing sets, legends, and scale Contours, spot elevations, and benchmarks Slope ratios, pitch, and foundation fall

20 20. Design, grading, and drainage: 3

Earthwork, accessible routes, and swales Water sources and French drains Inlets, conveyance, cleanouts, and outlets

21 21. Design, grading, and drainage: 4

Bioretention sizing, media, and plants Swales and current DEQ erosion controls

22 22. Irrigation design and operation: 1

Irrigation site survey and available water Hydrozones and plant-based irrigation design Sprinkler layout, arcs, and zone flow accounting

23 23. Irrigation design and operation: 2

Irrigation symbols, plans, and material takeoffs Pressure, elevation, friction, and budgets Sprinkler types, pressure, and coverage

24 24. Irrigation design and operation: 3

Matched precipitation and runtime formulas Drip irrigation, filtration, and wetted root volume Pipe materials, bore, velocity, and valves

25 25. Irrigation design and operation: 4

Valve service, wiring, and smart controls Controller circuits and electrical troubleshooting Plant culture and root-zone watering decisions

26 26. Irrigation design and operation: 5

Evapotranspiration, soil depletion, and runtime Catch-can audits and irrigation repair diagnosis Installation, testing, winterization, and startup

27 27. Backflow and potable protection: 1

Cross-connections, hazards, and reverse flow Air gaps and physical potable-water separation Vacuum breakers, checks, and RP assemblies

28 28. Backflow and potable protection: 2

Potable, irrigation, and reclaimed-water piping Backflow assembly selection and hydraulic cases Backflow installation, winter care, and reports

Potable, irrigation, and reclaimed-water piping

Key Takeaways Explain This Topic AI

Pipe approval, pressure rating, identification, and separation depend on the water use and jurisdiction.

A bypass must preserve the required protection level.

Never create an unprotected connection between potable water and reclaimed, pond, or chemical-bearing water.

Last updated: October 2026

Trace every connection

A cross-connection can be an actual or potential connection between potable water and an unsafe source. It may appear in a permanent tee, a temporary hose, a bypass, an improperly protected makeup line, or a shared manifold. Trace the source, branches, valves, outlets, pumps, tanks, and drains rather than assume the presence of one assembly protects every possible route.

Premises isolation protects the public supply at the service connection or approved point of delivery arrangement. Internal protection addresses hazards within the property. An assembly on one irrigation branch does not protect a separate unprotected hose or auxiliary supply connection upstream. Current Oregon rules require no cross-connections between the point of delivery and the premises-isolation assembly.

Draw the system during review. Mark potable and nonpotable portions, the direction of normal flow, potential reverse flow, and every path around protection. A normally closed valve is not physical separation; it can leak or be opened. A simple check valve is not equivalent to a listed backflow prevention assembly with the required capability.

Materials and pressure ratings

Use piping and components approved for the water use, pressure, temperature, burial, and exposure. Potable approval addresses health-related material requirements; a pressure rating addresses mechanical service. One does not replace the other. A product safe for nonpotable irrigation does not automatically qualify for a potable service extension.

Nominal size does not establish inside diameter or pressure capacity. Schedule and SDR/class designations describe different wall relationships. Confirm the product standard, marking, manufacturer's rating, temperature derating, joint method, and compatibility. Fittings and valves can have lower limits than the pipe. Include surge and test pressure in the review.

Metal transitions require compatible fittings and corrosion consideration. Plastic threaded fittings can crack from overtightening or inappropriate sealants. Use the approved procedure and avoid supporting a heavy assembly from flexible pipe alone. Provide the specified support and accessible unions or service arrangement without introducing an unprotected bypass.

Nonpotable and reclaimed systems

Reclaimed water can require designated identification, signs, outlet restrictions, separation, and application limits. Purple identification is common for reclaimed irrigation, but the actual jurisdiction's requirements govern the complete installation. Pipe color alone does not prove that an outlet is safe to use or that potable makeup is protected.

Keep source connections distinguishable and prevent accidental hose interchange. An owner may see two similar valves and connect the wrong one during repair. Labeling, route records, restricted connections, and approved protection reduce that risk. Do not blend potable and reclaimed systems through a selector valve or removable jumper without the required design and authority approval.

Potable backup to a tank or alternate-source system requires a reviewed protection method appropriate to the hazard. A pond, well, rainwater tank, and municipal supply can have different water quality and pressure conditions. The fact that both sources contain clear water is not evidence of potable compatibility. Assess chemical additions and pump-created backpressure as well.

Separation, crossings, and bypasses

Buried separation requirements depend on potable versus nonpotable use, sewer or other utility exposure, crossing conditions, and applicable code. Do not apply one twelve-inch clearance to every pipe and utility. Plan approved crossings before trenching, locate existing lines, and record final routes. Protect joints and maintain the prescribed bedding and cover.

Oregon requires a bypass around a backflow assembly to have approved protection providing at least the same level. A hose jumper used during testing can defeat the entire system. Plan service continuity through an approved parallel arrangement if needed, not through an improvised unprotected bypass. Isolation valves must not conceal an unsafe route.

An assembly's relief drain must not be directly connected to a sanitary or storm drain in a way that creates contamination exposure. DC vault drainage and RP air-gap drainage have specific requirements. Review the current rule and approved detail rather than assume any nearby drain is acceptable.

Scope and maintenance records

LCB permits appropriately licensed landscape professionals to perform authorized exterior irrigation work, while building plumbing connections and other service work have licensed-plumber boundaries. Determine the exact connection point and permit scope before cutting potable piping. An LCP license does not authorize every municipal main tap, meter setting, or interior connection.

After repairs, verify the arrangement and required testing. Record materials, routes, assembly identity, test status, and source labels. Future changes can add a hazard even when the original installation was compliant. Oregon drinking-water rules govern the protection and bypass relationships discussed here.

Reference table

  • Piping review Concern
  • Material approval Water use, pressure, temperature, exposure
  • Alternate source Contamination and pump-created backpressure
  • Bypass Equivalent approved protection
  • Identification Prevent mistaken connections and future excavation damage
  • Drainage No unsafe direct connection at relief or vault drains