Study guide
11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS
Key Takeaways Explain This Topic AI
Trickling filter hydraulic loading equals total applied flow, including recirculation, divided by surface area; organic loading equals BOD applied divided by media volume in 1,000 cubic feet.
Recirculation dilutes strong influent, keeps media wet, and evens out loading; the recirculation ratio is recycle flow divided by plant flow.
Ponding, filter flies, odors and icing are classic trickling filter problems, usually fixed by flushing, more recirculation, chlorinating the filter or improving ventilation.
RBC disks are about 40 percent submerged and turn slowly; white or gray biofilm signals sulfide-oxidizing Beggiatoa from overloading or septic influent.
MBBR and IFAS systems hold plastic carriers in aerated tanks behind screens; IFAS adds them to activated sludge to nitrify in less volume.
Last updated: October 2026
How Attached Growth Works
In fixed-film reactors, microorganisms grow as a biofilm (slime layer) on a surface. Wastewater flows over the film, organics and ammonia diffuse in, and oxygen diffuses from air or aerated water. The film thickens until the inner layers starve and lose their grip. Pieces then slough off and are captured in a downstream clarifier. Because the biomass stays put, fixed-film units handle shock loads well and need no return activated sludge control. In exchange, the operator has less direct control over the biology.
Trickling Filters
A rotary distributor spreads wastewater over a bed of rock (3-8 ft deep) or plastic media (often 15-40 ft tall). The liquid trickles down while air moves up or down through the voids by natural draft , driven by the temperature difference between air and wastewater, or by fans.
Filter class General loading Treatment expectation
Low-rate (standard) Light hydraulic and organic loading, little or no recirculation High BOD removal; may nitrify
- Intermediate and high-rate Heavier loading with recirculation Good BOD removal; little nitrification
- Roughing Very high organic loading Partial BOD removal ahead of another process
Loading formulas Hydraulic loading (gpd/sq ft) = Plant flow + Recirculated flow (gpd) Filter surface area (sq ft) \text{Hydraulic loading (gpd/sq ft)} = \frac{\text{Plant flow} + \text{Recirculated flow (gpd)}}{\text{Filter surface area (sq ft)}} Hydraulic loading (gpd/sq ft) = Filter surface area (sq ft) Plant flow + Recirculated flow (gpd) Organic loading (lb BOD/1,000 cu ft/day) = Flow (MGD) × BOD applied (mg/L) × 8.34 Media volume (cu ft) ÷ 1 , 000 \text{Organic loading (lb BOD/1,000 cu ft/day)} = \frac{\text{Flow (MGD)} \times \text{BOD applied (mg/L)} \times 8.34}{\text{Media volume (cu ft)} \div 1,000} Organic loading (lb BOD/1,000 cu ft/day) = Media volume (cu ft) ÷ 1 , 000 Flow (MGD) × BOD applied (mg/L) × 8.34 Recirculation ratio = Q recirculated Q plant \text{Recirculation ratio} = \frac{Q_{\text{recirculated}}}{Q_{\text{plant}}} Recirculation ratio = Q plant Q recirculated
Example. An 80-ft-diameter rock filter has 6 ft of media. It receives 1.2 MGD of primary effluent at 140 mg/L BOD, with 1.2 MGD recirculated (R = 1.0).
- Area = 0.785 × 80² = 5,024 sq ft; volume = 5,024 × 6 = 30,144 cu ft
- Hydraulic loading = 2,400,000 ÷ 5,024 = 478 gpd/sq ft
- BOD applied = 1.2 × 140 × 8.34 = 1,401 lb/day; organic loading = 1,401 ÷ 30.144 = 46.5 lb/1,000 cu ft/day
- Recirculation benefits
Recirculation dilutes strong or toxic influent, keeps the media wetted during low night flows (preventing dry spots and fly breeding), helps flush excess growth, and evens out the load reaching the biofilm.
Troubleshooting trickling filters
Problem Causes Corrections
Ponding (standing water on the surface) Excess growth or debris plugging voids; poor primary treatment Increase recirculation; flush with high hydraulic loads; chlorinate a section briefly; remove debris
Filter flies ( Psychoda ) Intermittently wet media, low flow Keep media continuously wet; flood or chlorinate briefly; raise recirculation
Odors Anaerobic conditions from overloading or poor ventilation Reduce load, increase recirculation, open vents, check underdrains
Icing Cold air drawn through the bed Reduce recirculation of cold water, add windbreaks or covers
Distributor arm stopping Plugged orifices, bearing failure, low flow Clean orifices and end flush gates, service bearings, maintain minimum flow
Rotating Biological Contactors (RBCs)
An RBC is a shaft of closely spaced plastic disks, about 40 percent submerged , turning slowly (about 1 to 1.6 rpm) in a tank. As each disk rotates, the biofilm alternately absorbs organics from the water and oxygen from the air. Units are arranged in stages : the first stages remove BOD, and later stages can nitrify. Covers protect the biofilm from cold, rain and sunlight.
- Observation Meaning
- Thin, shaggy brown-gray growth Normal, healthy biofilm
White or gray patches , especially on first stages Beggiatoa and other sulfur organisms; first-stage overload or septic, high-sulfide influent
Excessively thick growth, shaft strain or bearing noise Overloading; danger of shaft or bearing failure from biomass weight
Sloughing all at once Toxic shock or pH or temperature swings
Fixes for first-stage overload include removing baffles to spread load over more stages, step-feeding, supplemental air, or pretreating to remove sulfides.
Moving Bed Biofilm Reactors (MBBR) and IFAS
MBBR : small plastic carriers with high protected surface area float freely in an aerated (or mixed anoxic) tank, typically filling 25 to 65 percent of the volume. Screens at the outlet keep carriers in the tank. No sludge return is needed; a downstream clarifier or DAF removes sloughed solids.
IFAS (integrated fixed-film activated sludge) : carriers or fixed media are added to an activated sludge basin. Slow-growing nitrifiers live on the media while the suspended biomass handles BOD. That allows nitrification in less basin volume or at a lower suspended sludge age, which is useful when upgrading an existing plant for ammonia limits.
Operating concerns include screen blinding by rags or foam, carrier loss through damaged screens, uneven carrier mixing, and enough dissolved oxygen (often 3 to 4 mg/L) to penetrate the biofilm. DEQ's Table A rates SBR, MBBR, integrated fixed film and activated sludge with separate fixed film as Class III up to 5 MGD ADWF and Class IV above.