Study guide
8.3 Service Connections, Meters, Water Loss Control and Utility Locating
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
8.3 Service Connections, Meters, Water Loss Control and Utility Locating
Key Takeaways Explain This Topic AI
A service runs from the corporation stop on the main through the service line and curb stop to the meter setter; OAR 333-061 governs it up to the property line or meter, and the plumbing code governs the building side.
New mains need at least 30 inches of cover, and nonconductive pipe needs a No. 18 AWG blue tracer wire accessible at boxes or casings (OAR 333-061-0050(8)).
Positive-displacement meters suit small residential services, turbine meters suit high steady flows, and compound meters cover wide flow ranges; aging meters usually under-register at low flow.
In the AWWA water balance, non-revenue water is system input minus billed authorized consumption, and water losses split into apparent losses (meters, data, theft) and real losses (leaks and overflows).
Oregon excavators call 811 at least two full business days before digging; blue marks potable water, green sewer and drain lines, and purple reclaimed water.
Last updated: October 2026
Anatomy of a Service Connection
- Component Function
- Corporation stop ("corp") Valve threaded or saddled into the main; the tap point
- Tapping saddle Clamps around the main to support the tap; required on many pipe materials such as PVC
- Service line Copper (Type K), polyethylene (PE) or PEX tubing from the main to the meter
- Curb stop and box Customer shutoff near the property line, reached with a curb key
- Meter setter and box Holds the meter, couplings and an angle valve; may include a dual check
Customer side Building supply line under the plumbing code; premises isolation backflow assembly where required
Under OAR 333-061-0050(8), mains and the portion of the service from the main to the property line or meter are subject to OHA's construction standards. The piping beyond the meter is subject to the state plumbing code .
Installation Standards
Use NSF/ANSI 61-certified materials for anything contacting drinking water. Mains, fittings and valves at community systems must meet AWWA or equivalent standards.
Bed pipe in rock-free material, tamp select backfill around it, and provide at least 30 inches of cover .
Install No. 18 AWG (minimum) solid copper tracer wire with blue insulation on plastic pipe, with wire ends accessible in meter boxes, valve boxes or casings.
Restrain bends, tees, plugs and hydrants against movement.
Tapping
A wet tap connects a new service or main to a pressurized main without an outage. The crew installs the saddle or tapping sleeve and corporation stop (or tapping valve), bolts on a tapping machine , cuts the hole through the valve, retracts the cutter and coupon, and closes the valve. The coupon is recovered and the work site is disinfected. Dry taps on out-of-service mains still require disinfection and flushing before use.
Lead Service Line Inventories
Since October 16, 2024 , every community and NTNC system must keep an inventory classifying each service line, utility side and customer side, as lead, galvanized requiring replacement, non-lead or unknown . Customers with lead, GRR or unknown lines must be notified. Under the Lead and Copper Rule Improvements, a baseline inventory and replacement plan are due by November 1, 2027, and replacement must generally be complete by the end of 2037. Field crews document line materials whenever they expose a service.
Water Meters
Meter type Principle Best use
Positive displacement (nutating disc or piston) Fixed volume per rotation Residential 5/8- to 1-inch services; accurate at low flow
- Multi-jet / single-jet Jets turn an impeller Small services
- Turbine Rotor in the flow stream High, steady flows (irrigation, industry)
Compound Small meter plus turbine with an automatic changeover Large buildings with very low and very high flows
- Electromagnetic and ultrasonic No moving parts Wide range, little headloss, long accuracy life
- Fire service or detector check Meters small leaks on fire lines Detecting unauthorized use of fire services
Mechanical meters wear and usually under-register , especially at low flows such as toilet leaks. Utilities test and replace meters on a schedule based on size, age and accumulated volume. AMR (automatic meter reading) collects reads by drive-by radio. AMI (advanced metering infrastructure) adds two-way fixed networks that can flag continuous-flow leaks and backflow events.
Water Loss Control: The AWWA Water Balance
The AWWA M36 method accounts for every gallon entering the system:
System input volume = authorized consumption + water losses
Authorized consumption = billed (metered and unmetered) + unbilled (hydrant flushing, firefighting, utility use)
- Water losses
- Apparent losses : customer meter under-registration, data handling errors, unauthorized consumption
- Real losses : leakage on mains and services, and storage tank leaks and overflows
Non-revenue water (NRW) = unbilled authorized consumption + apparent losses + real losses = system input − billed authorized consumption
Worked example
A system's input is 1,200 MG per year. Billed authorized consumption is 1,020 MG, and unbilled authorized use (flushing and firefighting) is 18 MG.
- NRW = 1,200 − 1,020 = 180 MG (15 percent of input)
- Water losses = 180 − 18 = 162 MG (13.5 percent)
Apparent losses are fixed with meter testing and billing audits. Real losses are cut by active leak detection (acoustic listening, leak-noise correlators and loggers, step testing at night), faster repairs, pressure management (less pressure means less leakage) and main replacement.
Locating Before You Dig
Oregon's one-call law requires excavators to notify the Oregon Utility Notification Center by calling 811 at least two full business days before digging. Operators who own buried facilities must respond by marking them. Standard APWA marking colors:
- Color Facility
- Blue Potable water
- Green Sewers and storm drains
- Purple Reclaimed or recycled water, irrigation, slurry lines
- Red Electric power
- Yellow Gas, oil, steam
- Orange Communications
- White Proposed excavation
- Pink Temporary survey marks
Locating methods include direct connection of a transmitter to tracer wire or metallic pipe, inductive sweeps, and records or GIS checks. Nonmetallic pipe without tracer wire is the hardest to find, which is why OHA requires tracer wire. Hand-dig or use vacuum excavation within the tolerance zone around marks, and keep maps and GIS current after every repair or installation.