9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
Key Takeaways Explain This Topic AI
Water age is the primary driver of finished water quality deterioration, accelerating disinfectant decay, trihalomethane (TTHM) formation, and biofilm detachment.
Any Oregon system that adds a disinfectant must keep a detectable residual throughout distribution (OAR 333-061-0036(9)), measured at least twice weekly and with each coliform sample; the MRDL for chlorine and chloramines is 4.0 mg/L as Cl2.
Chloramination requires a tightly controlled Cl 2 : NH 3 -N \text{Cl}_2:\text{NH}_3\text{-N} Cl 2 : NH 3 -N weight ratio of 4.5 : 1 4.5:1 4.5 : 1 to 5 : 1 5:1 5 : 1 to generate stable monochloramine without excess free ammonia.
Nitrification is a biological chain reaction where autotrophic bacteria oxidize free ammonia into nitrite (AOB) and nitrate (NOB), rapidly destroying chloramine residuals and lowering water pH.
Unidirectional Flushing (UDF) enforces single-path flows at scouring velocities ( ≥ 5 − 6 ft/s \ge 5-6\text{ ft/s} ≥ 5 − 6 ft/s ) from clean mains outward; all chlorinated flush water must be chemically dechlorinated prior to discharge.
Last updated: October 2026
6.4 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
Producing high-quality potable water at a water treatment plant does not guarantee safe water at the consumer's tap. Once finished water enters distribution mains, it enters a dynamic, living physical and chemical environment. Miles of pipe walls, varying flow velocities, extended hydraulic retention times, seasonal temperature shifts, and sediment deposits all interact to alter water chemistry and foster microbiological regrowth.
Water distribution operators must actively manage distribution water quality to prevent waterborne disease, control disinfection byproducts, avoid nitrification crashes, and satisfy the water quality mandates of OAR Chapter 333, Division 061 .
Water Age & Chemical / Biological Degradation
Water Age is defined as the total travel time required for treated water to journey from the water treatment plant effluent clearwell to a customer's service connection. Water age is the single most critical factor influencing finished water quality degradation.
Factors Compounding Excessive Water Age
Oversized Piping : Distribution mains designed for 50-year master plan fire flows or future population growth maintain sluggish flow velocities ( < 0.5 ft/s <0.5\text{ ft/s} < 0.5 ft/s ) under current domestic demands.
Oversized Storage Reservoirs : Tanks operating with minimal daily drawdown cycle water over weeks rather than days.
Network Topologies : Dead-end cul-de-sacs, terminal branches, and low-demand pressure zones.
Seasonal Fluctuations : High-capacity winter distribution networks operating at a fraction of peak summer irrigation demand.
Consequences of Elevated Water Age
Disinfectant Decay : Natural oxidation reactions with organic carbon and pipe walls consume free chlorine and chloramines, eventually reducing residuals to zero.
Disinfection Byproduct (DBP) Amplification : Total Trihalomethanes (TTHMs) and Haloacetic Acids (HAA5) continue to form as long as a chlorine residual interacts with trace natural organic matter (NOM). In dead-end zones with water age exceeding 10 to 14 days 10\text{ to }14\text{ days} 10 to 14 days , TTHM levels can double, violating the federal Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Levels (MCLs: 0.080 mg/L 0.080\text{ mg/L} 0.080 mg/L for TTHM, 0.060 mg/L 0.060\text{ mg/L} 0.060 mg/L for HAA5).
Biofilm Proliferation : Pipe walls support complex biological films composed of bacteria ( Pseudomonas , Mycobacterium , Aeromonas ), fungi, and amoebae encapsulated in a protective slime matrix of Extracellular Polymeric Substances (EPS). When disinfectant residuals vanish, biofilms detach, creating aesthetic turbidity, bitter taste/odor, and coliform compliance violations under the Revised Total Coliform Rule (RTCR).
Internal Tuberculation & Corrosion : Water stagnation depletes dissolved oxygen near pipe surfaces, creating local anaerobic micro-environments that foster sulfate-reducing bacteria and iron-oxidizing bacteria, inducing pitting corrosion and red/black water complaints.
Disinfectant Residual Maintenance (OAR 333-061)
Oregon does not require every system to disinfect. Properly built wells that meet microbiological standards may serve untreated water. Once a system adds a disinfectant, these rules apply:
Detectable residual : every public water system that adds a disinfectant, or delivers disinfected water, must maintain a detectable disinfectant residual throughout the distribution system . It must measure and record the residual at representative points at least twice per week and at the same points and times as coliform samples (OAR 333-061-0036(9)).
Surface water and GWUDI systems : the residual entering distribution may not stay below 0.2 mg/L for more than 4 hours. The residual in distribution may not be undetectable in more than 5 percent of monthly samples for two consecutive months.
Groundwater systems required to disinfect continuously (for example after confirmed fecal contamination): when chlorine is used, at least 0.2 mg/L must be maintained throughout the distribution system (OAR 333-061-0036 and -0032 provisions).
Maximum residual disinfectant level (MRDL) : 4.0 mg/L as Cl2 for free chlorine and for chloramines, computed as a running annual average of distribution samples. Chlorine dioxide's MRDL is 0.8 mg/L.
Practical targets : many utilities aim for roughly 0.2-0.5 mg/L free chlorine, or 1-2 mg/L or more total chlorine with chloramines, at system extremities. These are operating goals, not separate OHA minimums.
Chloramination Chemistry & Nitrification Episodes
Many medium and large water utilities in Oregon and across the United States convert from free chlorine to chloramines (combined chlorine) to control disinfection byproducts (TTHMs and HAA5) and maintain a stable, long-lasting residual in extensive, high-water-age distribution systems.
Chloramine Formation Chemistry
Chloramines are generated by dosing chlorine gas or sodium hypochlorite into finished water containing or dosed with aqueous ammonia ( NH 3 \text{NH}_3 NH 3 ). The reaction produces three chemical species depending on pH and the chlorine-to-ammonia weight ratio:
Cl 2 + NH 3 → NH 2 Cl (Monochloramine) + HCl \text{Cl}_2 + \text{NH}_3 \rightarrow \text{NH}_2\text{Cl (Monochloramine)} + \text{HCl} Cl 2 + NH 3 → NH 2 Cl (Monochloramine) + HCl NH 2 Cl + Cl 2 → NHCl 2 (Dichloramine) + HCl \text{NH}_2\text{Cl} + \text{Cl}_2 \rightarrow \text{NHCl}_2 \text{ (Dichloramine)} + \text{HCl} NH 2 Cl + Cl 2 → NHCl 2 (Dichloramine) + HCl NHCl 2 + Cl 2 → NCl 3 (Trichloramine) + HCl \text{NHCl}_2 + \text{Cl}_2 \rightarrow \text{NCl}_3 \text{ (Trichloramine)} + \text{HCl} NHCl 2 + Cl 2 → NCl 3 (Trichloramine) + HCl
Monochloramine ( NH 2 Cl \text{NH}_2\text{Cl} NH 2 Cl ) : The strictly preferred distribution disinfectant species. It is chemically stable, produces minimal taste or odor, and generates virtually zero trihalomethanes. Formed optimally at pH 7.5 to 9.0 \text{pH } 7.5\text{ to }9.0 pH 7.5 to 9.0 and a precise Cl 2 : NH 3 -N \text{Cl}_2:\text{NH}_3\text{-N} Cl 2 : NH 3 -N weight ratio between 4.5 : 1 and 5.0 : 1 4.5:1\text{ and }5.0:1 4.5 : 1 and 5.0 : 1 .
Dichloramine ( NHCl 2 \text{NHCl}_2 NHCl 2 ) : Formed at lower pH ( < 6.5 <6.5 < 6.5 ) or higher chlorine ratios ( > 5.5 : 1 >5.5:1 > 5.5 : 1 ). Imparts strong, offensive chlorinous "swimming pool" odors and causes customer complaints.
Trichloramine / Nitrogen Trichloride ( NCl 3 \text{NCl}_3 NCl 3 ) : Formed at low pH ( < 5.0 <5.0 < 5.0 ) or heavy excess chlorine. Severe eye irritant and noxious odor compound.
Caution
If the chlorine-to-ammonia weight ratio drops below 4.5 : 1 4.5:1 4.5 : 1 (excess ammonia), unreacted free ammonia enters the distribution system. If the ratio exceeds 5.0 : 1 5.0:1 5.0 : 1 , chlorine oxidizes monochloramine toward the breakpoint chlorination curve , destroying the residual!
The Nitrification Cycle & Microbiology
Nitrification is an autotrophic biological process wherein specialized bacteria oxidize free ammonia into nitrite and nitrate. In a chloraminated distribution system, excessive water age, warm temperatures ( > 15 ∘ C / 60 ∘ F >15^{\circ}\text{C} / 60^{\circ}\text{F} > 1 5 ∘ C /6 0 ∘ F ), and excess free ammonia trigger severe nitrification episodes. THE DISTRIBUTION NITRIFICATION SPIRAL
- Excess Free Ammonia (NH3) in Distribution Mains
- │
- ▼
- [Ammonia-Oxidizing Bacteria (AOB) - Nitrosomonas]
- │ Consumes NH3 + O2
- ▼
Produces Nitrite (NO2-) ──► RAPIDLY CONSUMES CHLORAMINES!
- │ (1 mg/L NO2- destroys ~5 mg/L Cl2!)
- ▼
- [Nitrite-Oxidizing Bacteria (NOB) - Nitrobacter]
- │ Consumes NO2- + O2
- ▼
- Produces Nitrate (NO3-) + Hydrogen Ions (H+)
- │
- ▼
Water pH Plummets, Residual Crashes to 0 mg/L, Coliform Regrowth Surges!
Step 1 (Ammonia Oxidation) : Ammonia-Oxidizing Bacteria (AOB, primarily Nitrosomonas ) consume free ammonia, producing nitrite ( NO 2 − \text{NO}_2^- NO 2 − ) and releasing hydrogen ions: 2 NH 3 + 3 O 2 → AOB 2 NO 2 − + 2 H + + 2 H 2 O 2\text{NH}_3 + 3\text{O}_2 \xrightarrow{\text{AOB}} 2\text{NO}_2^- + 2\text{H}^+ + 2\text{H}_2\text{O} 2 NH 3 + 3 O 2 AOB 2 NO 2 − + 2 H + + 2 H 2 O
Step 2 (Nitrite Oxidation) : Nitrite-Oxidizing Bacteria (NOB, primarily Nitrobacter ) oxidize nitrite into nitrate ( NO 3 − \text{NO}_3^- NO 3 − ) : 2 NO 2 − + O 2 → NOB 2 NO 3 − 2\text{NO}_2^- + \text{O}_2 \xrightarrow{\text{NOB}} 2\text{NO}_3^- 2 NO 2 − + O 2 NOB 2 NO 3 −
The Chemical Residual Destruction Trap : Nitrite ( NO 2 − \text{NO}_2^- NO 2 − ) is a powerful chemical reducing agent that directly and instantaneously reacts with chloramines. 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L of nitrite chemically reduces and destroys approximately 5.0 mg/L 5.0\text{ mg/L} 5.0 mg/L of chloramine residual! This creates a runaway feedback loop: falling chloramines allow AOB to proliferate faster, producing more nitrite, which completely wipes out the remaining disinfectant residual.
Early Warning Indicators of Nitrification
Operators must monitor distribution monitoring stations for early chemical indicators before a catastrophic biological crash occurs:
Water Quality Parameter Baseline / Normal Status Active Nitrification Status
Total Chlorine Residual Stable ( 1.5 − 3.0 mg/L 1.5 - 3.0\text{ mg/L} 1.5 − 3.0 mg/L ) Sharp, unexpected drop ( < 0.5 mg/L <0.5\text{ mg/L} < 0.5 mg/L )
Nitrite Concentration ( NO 2 − -N \text{NO}_2^-\text{-N} NO 2 − -N ) < 0.010 mg/L <0.010\text{ mg/L} < 0.010 mg/L Spike > 0.015 − 0.050 mg/L >0.015 - 0.050\text{ mg/L} > 0.015 − 0.050 mg/L (Immediate Action Trigger)
Free Ammonia Low ( < 0.05 mg/L <0.05\text{ mg/L} < 0.05 mg/L ) Initial spike, followed by steep decline as AOB consume it
pH & Alkalinity Stable (e.g., 7.8 − 8.2 7.8 - 8.2 7.8 − 8.2 ) Noticeable drop (ammonia oxidation generates H + \text{H}^+ H + acid)
Heterotrophic Plate Count (HPC) Low ( < 50 CFU/mL <50\text{ CFU/mL} < 50 CFU/mL ) Surge > 500 CFU/mL >500\text{ CFU/mL} > 500 CFU/mL (loss of biological inhibition)
Nitrification Prevention & Corrective Actions
Source Ratio Optimization : Enforce strict chemical dosing to maintain the 4.5 : 1 to 5.0 : 1 4.5:1\text{ to }5.0:1 4.5 : 1 to 5.0 : 1 Cl 2 : N \text{Cl}_2:\text{N} Cl 2 : N ratio, targeting residual free ammonia below 0.05 mg/L 0.05\text{ mg/L} 0.05 mg/L .
Deep Tank Cycling : Lower reservoir operating levels during low-demand periods to maintain a 3 − 5 day 3-5\text{ day} 3 − 5 day turnover cycle.
Intensive Main Flushing : Unidirectional flushing to sweep out nitrifying biofilms and sediment.
"Free Chlorine Burnout" : The ultimate corrective procedure. The utility coordinates with OHA and temporarily suspends ammonia addition at the treatment plant, distributing free chlorine ( 2.5 − 3.5 mg/L 2.5 - 3.5\text{ mg/L} 2.5 − 3.5 mg/L ) throughout the entire distribution network for 2 to 4 weeks . Free chlorine penetrates and inactivates resistant AOB and NOB biofilm matrices, completely breaking the biological cycle before the utility transitions back to chloramination.
Distribution Flushing Programs
Flushing cleanses distribution pipelines, removes accumulated mineral sediments (iron, manganese, sand), scours bacterial biofilms, restores Hazen-Williams C C C -factors, and replaces stale water with fresh finished water.
Conventional Flushing vs. Unidirectional Flushing (UDF) CONVENTIONAL FLUSHING (Disorganized) UNIDIRECTIONAL FLUSHING - UDF (Engineered)
Hydrant opened randomly without valve control. Valves closed systematically to direct flow.
- ◄── Dirty Water ──► Clean Water Inflow
- ───► Stagnant Main ◄─── ═════════════════════════════►
- Water pulled from all directions; low High scouring velocity (≥ 5-6 ft/s);
velocities (< 2-3 ft/s) stir up sediment cleans from source outward in controlled loops!
without scouring pipe walls! Wastes water! Conserves 40-50% water!
Conventional Flushing : Crews open hydrants in an area without isolating boundary valves. Water flows toward the hydrant from multiple directions simultaneously. Water velocity inside individual pipes rarely exceeds 2.0 to 3.0 ft/s 2.0\text{ to }3.0\text{ ft/s} 2.0 to 3.0 ft/s . This velocity is sufficient to stir up settled iron sediment and provoke customer dirty water complaints, but is completely incapable of stripping adherent biofilm or removing heavy tuberculation scale. Stagnant water from dirty side mains is pulled across clean mains.
Unidirectional Flushing (UDF) : A systematic, highly engineered flushing methodology. UDF begins at the clean source (treatment plant or major transmission main) and proceeds outward through the network in a sequentially planned progression. Distribution valves are closed to isolate a single pipeline run, forcing water to flow in one direction through a single pipe :
Target Velocity ( ≥ 5.0 − 6.0 ft/s \ge 5.0 - 6.0\text{ ft/s} ≥ 5.0 − 6.0 ft/s ) : High kinetic shear stresses strip and scour biofilm, dislodge tuberculation scale, and flush out heavy mineral deposits.
Clean-to-Dirty Progression : Only clean, freshly flushed water is introduced into the next pipe segment.
Efficiency : Achieves complete pipeline scouring while using 40 % to 50 % 40\%\text{ to }50\% 40% to 50% less water than conventional flushing.
Dead-End Blow-Off Assemblies
Dead ends terminating in cul-de-sacs that lack fire hydrants must feature permanent blow-off assemblies (minimum 2-inch diameter). Modern distribution utilities install automated, solar-powered, battery-operated blow-off stations programmed to discharge water during early morning hours ( 2 : 00 AM − 4 : 00 AM 2:00\text{ AM} - 4:00\text{ AM} 2 : 00 AM − 4 : 00 AM ) based on time or real-time total chlorine sensor feedback, keeping dead-end residuals above 0.2 mg/L 0.2\text{ mg/L} 0.2 mg/L .
Environmental Protection: Chemical Dechlorination
Discharging chlorinated or chloraminated water into storm drains, street gutters, ditches or streams without dechlorination can kill fish and violate Oregon water quality rules and the Clean Water Act. Check local stormwater requirements and any DEQ permit conditions before flushing.
Aquatic Toxicity of Disinfectant Residuals
Chlorine and chloramines are acutely toxic to salmonids (Chinook salmon, Coho salmon, steelhead) and sensitive aquatic macroinvertebrates at concentrations as low as 0.01 to 0.02 mg/L 0.01\text{ to }0.02\text{ mg/L} 0.01 to 0.02 mg/L ( 10 − 20 ppb 10 - 20\text{ ppb} 10 − 20 ppb ) . Residual chlorine causes gill necrosis, asphyxiation, and massive fish kills in Oregon urban streams.
Chemical Neutralizing Agents
Flushing operations must employ specialized diffuser assemblies or containment mats dosed with approved chemical dechlorination agents:
Neutralizing Chemical Chemical Formula Key Characteristics & Environmental Considerations
Ascorbic Acid (Vitamin C) C 6 H 8 O 6 \text{C}_6\text{H}_8\text{O}_6 C 6 H 8 O 6 Preferred for sensitive Oregon waterways; rapidly neutralizes chlorine and chloramines; consumes zero dissolved oxygen; non-toxic to aquatic life; slightly lowers pH
Sodium Ascorbate C 6 H 7 NaO 6 \text{C}_6\text{H}_7\text{NaO}_6 C 6 H 7 NaO 6 Sodium salt of Vitamin C; neutral pH; highly soluble; zero oxygen depletion; excellent for high-volume stream discharges
Sodium Bisulfite NaHSO 3 \text{NaHSO}_3 NaHSO 3 Rapid reaction; low chemical cost; scavenges dissolved oxygen ( 1 lb 1\text{ lb} 1 lb consumes significant DO); hazardous if over-dosed in fish-bearing creeks
Sodium Thiosulfate Na 2 S 2 O 3 \text{Na}_2\text{S}_2\text{O}_3 Na 2 S 2 O 3 Common dry granule agent; slower reaction with chloramines; over-dosing can generate noxious sulfur compounds and deplete DO
Important
During all distribution flushing activities, field crews must verify chemical neutralization by testing the final discharge water with a DPD colorimeter or high-sensitivity chlorine test kit . The discharge residual must read non-detectable ( 0.0 mg/L 0.0\text{ mg/L} 0.0 mg/L ) before water is permitted to enter any storm sewer or natural drainage course.