Study guide
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations
Key Takeaways Explain This Topic AI
Hypochlorous acid (HOCl) is 80 to 100 times more potent as a germicide than the hypochlorite ion (OCl⁻), making disinfection efficacy highly sensitive to water pH.
The breakpoint chlorination nadir occurs when chlorine-to-ammonia nitrogen ratios reach 7.6:1 to 10:1, destroying chloramines through oxidation to nitrogen gas before free chlorine residual can appear.
Total Trihalomethanes (TTHMs) and five Haloacetic Acids (HAA5) have strict Maximum Contaminant Levels of 0.080 mg/L and 0.060 mg/L, regulated on a Locational Running Annual Average (LRAA).
The CT concept evaluates disinfectant concentration multiplied by effective contact time (T₁₀ = DT × Baffling Factor) to verify regulatory Giardia and viral log-inactivation credits.
Last updated: October 2026
3.4 Disinfection Chemistry, Chlorination Dynamics & CT Calculations
Note
Disinfection is the final, non-negotiable public health barrier in drinking water treatment. Water operators must master the chemical equilibrium between hypochlorous acid and hypochlorite ions, understand breakpoint chlorination curves, control disinfection byproducts (DBPs), and perform precise C T CT CT calculations to guarantee regulatory pathogen inactivation.
Disinfection Objectives & Pathogen Targets
Drinking water disinfection serves two distinct public health objectives:
Primary Disinfection: The in-plant inactivation or killing of pathogenic organisms within contact basins and clearwells to achieve regulatory log-reduction credits.
Secondary Disinfection: The maintenance of a persistent biocidal chemical residual throughout the distribution piping network and finished water storage tanks to suppress bacterial regrowth, inhibit biofilm development, and protect against contamination from low-pressure back-siphonage events.
Primary Microbial Targets
Giardia lamblia Cysts: A flagellated protozoan parasite causing human giardiasis. The infectious cyst has a tough, fibrous outer wall that makes it moderately resistant to chemical disinfection. Under the Surface Water Treatment Rule (SWTR), treatment plants must achieve a minimum 3.0 -log 3.0\text{-log} 3.0 -log ( 99.9 % 99.9\% 99.9% ) removal and/or inactivation of Giardia cysts.
Cryptosporidium parvum Oocysts: A protozoan parasite whose thick outer shell is virtually impervious to standard free chlorine concentrations ( C T > 7 , 000 mg ⋅ min/L CT > 7,000 \text{ mg}\cdot\text{min/L} CT > 7 , 000 mg ⋅ min/L required). Inactivation requires physical filtration, Ultraviolet (UV) irradiation , or ozone .
Enteric Viruses: Small viral particles (including rotavirus, hepatitis A, norovirus, and enteroviruses) responsible for severe gastrointestinal illnesses. SWTR requires a minimum 4.0 -log 4.0\text{-log} 4.0 -log ( 99.99 % 99.99\% 99.99% ) removal and/or inactivation of enteric viruses.
Residual Requirements: For surface water and GWUDI systems, the disinfectant residual entering the distribution system may not be below 0.2 mg/L 0.2 \text{ mg/L} 0.2 mg/L for more than 4 hours. The residual in the distribution system may not be undetectable in more than 5 percent of monthly samples for two consecutive months. Any Oregon system that adds a disinfectant must keep a detectable residual throughout distribution , measured at least twice a week and with every coliform sample (OAR 333-061-0036(9)).
Disinfectant Types & Chemical Properties
Disinfectant Type Chemical Formula Available Chlorine Equivalent Operational Pros & Cons
Chlorine Gas Cl 2 \text{Cl}_2 Cl 2 100 % 100\% 100% Low chemical cost; depresses pH; severe hazardous toxic inhalation risk (gas density 2.5 × 2.5 \times 2.5 × air)
Sodium Hypochlorite NaOCl \text{NaOCl} NaOCl 12.5 − 15.0 % 12.5 - 15.0\% 12.5 − 15.0% Liquid solution; safe storage; degrades with heat/light; raises water pH; produces chlorate
Calcium Hypochlorite Ca(OCl) 2 \text{Ca(OCl)}_2 Ca(OCl) 2 65 − 68 % 65 - 68\% 65 − 68% Granular or tablet form; long shelf life; powerful oxidizer/fire hazard; increases water hardness
Chlorine Dioxide ClO 2 \text{ClO}_2 ClO 2 263 % 263\% 263% (by oxidation) Powerful oxidant; unaffected by pH 6 − 9 6-9 6 − 9 ; no TTHMs/HAAs; produces toxic chlorite/chlorate
Ozone O 3 \text{O}_3 O 3 N/A Strongest chemical oxidant; inactivates Cryptosporidium ; zero distribution residual; forms bromate
Ultraviolet (UV) Light Electromagnetic ( 254 nm 254 \text{ nm} 254 nm ) N/A Photochemical DNA disruption; superior against Cryptosporidium ; zero chemical DBPs; zero residual
Aqueous Chlorine Chemistry & pH Equilibrium
When chlorine gas ( Cl 2 \text{Cl}_2 Cl 2 ) is dissolved in water, it undergoes an instantaneous hydrolysis reaction (completing in milliseconds): Cl 2 (g) + H 2 O ⇌ HOCl + H + + Cl − \text{Cl}_2\text{(g)} + \text{H}_2\text{O} \rightleftharpoons \text{HOCl} + \text{H}^+ + \text{Cl}^- Cl 2 (g) + H 2 O ⇌ HOCl + H + + Cl −
This reaction produces hypochlorous acid ( HOCl \text{HOCl} HOCl ) , hydrogen ions (which lower pH), and chloride ions. When sodium hypochlorite ( NaOCl \text{NaOCl} NaOCl ) is used, it dissociates: NaOCl + H 2 O ⇌ HOCl + Na + + OH − \text{NaOCl} + \text{H}_2\text{O} \rightleftharpoons \text{HOCl} + \text{Na}^+ + \text{OH}^- NaOCl + H 2 O ⇌ HOCl + Na + + OH −
producing hypochlorous acid and hydroxide ions (which raise pH). +-----------------------------------------------------------------------------+
- | CHLORINE pH EQUILIBRIUM: HOCl vs. OCl- |
- +-----------------------------------------------------------------------------+
- | |
- | HOCl <=====================> H+ + OCl- (pKa = 7.54 at 20°C) |
- | |
- | 100% | *** HOCl (Potent Germicide, Neutral Molecule) |
- | | * |
- | 75% | ** |
- | | * |
- | 50% |---------*----------------------- (pH 7.5: 50% HOCl / 50% OCl-) |
- | | * |
- | 25% | ** |
- | | * |
- | 0% |______________***________________ OCl- (Weak Germicide, Anion) |
- | 4.0 5.0 6.0 7.0 7.5 8.0 9.0 10.0 (pH Units) |
- +-----------------------------------------------------------------------------+
- The Acid-Base Dissociation Equilibrium
Hypochlorous acid is a weak acid that partially dissociates into hydrogen ions and hypochlorite ions ( OCl − \text{OCl}^- OCl − ) : HOCl ⇌ H + + OCl − \text{HOCl} \rightleftharpoons \text{H}^+ + \text{OCl}^- HOCl ⇌ H + + OCl −
Biocidal Potency: Hypochlorous acid ( HOCl \text{HOCl} HOCl ) is an electrically neutral, uncharged molecule of small molecular size. Because it possesses no electrical charge, it rapidly penetrates the negatively charged lipid bilayer membrane of bacterial cells and protozoan cysts, inactivating vital intracellular enzymes. In contrast, the hypochlorite ion ( OCl − \text{OCl}^- OCl − ) carries a negative electrical charge and is electrostatically repelled by bacterial cell walls. Consequently, HOCl \text{HOCl} HOCl is 80 to 100 times more effective as a disinfectant than OCl − \text{OCl}^- OCl − .
pH Dependence ( p K a ≈ 7.54 at 20 ∘ C pK_a \approx 7.54 \text{ at } 20^\circ\text{C} p K a ≈ 7.54 at 2 0 ∘ C ):
At pH 6.0 \text{pH } 6.0 pH 6.0 : ≈ 97 % HOCl \approx 97\% \text{ HOCl} ≈ 97% HOCl and 3 % OCl − 3\% \text{ OCl}^- 3% OCl −
At pH 7.0 \text{pH } 7.0 pH 7.0 : ≈ 78 % HOCl \approx 78\% \text{ HOCl} ≈ 78% HOCl and 22 % OCl − 22\% \text{ OCl}^- 22% OCl −
At pH 7.5 \text{pH } 7.5 pH 7.5 : ≈ 50 % HOCl \approx 50\% \text{ HOCl} ≈ 50% HOCl and 50 % OCl − 50\% \text{ OCl}^- 50% OCl −
At pH 8.0 \text{pH } 8.0 pH 8.0 : ≈ 26 % HOCl \approx 26\% \text{ HOCl} ≈ 26% HOCl and 74 % OCl − 74\% \text{ OCl}^- 74% OCl −
At pH 8.5 \text{pH } 8.5 pH 8.5 : ≈ 9 % HOCl \approx 9\% \text{ HOCl} ≈ 9% HOCl and 91 % OCl − 91\% \text{ OCl}^- 91% OCl −
Operational Takeaway: Operating a disinfection clearwell at pH 8.5 \text{pH } 8.5 pH 8.5 rather than pH 7.0 \text{pH } 7.0 pH 7.0 reduces the concentration of active HOCl \text{HOCl} HOCl by nearly 90 % 90\% 90% . To achieve equivalent pathogen inactivation at elevated pH, an operator must drastically increase chlorine dosage or substantially extend contact time.
Breakpoint Chlorination Dynamics
When chlorine is dosed into water containing reducing inorganic minerals and ammonia nitrogen ( NH 3 \text{NH}_3 NH 3 ), it proceeds across four distinct operational zones along the breakpoint chlorination curve : +-----------------------------------------------------------------------------+
- | THE BREAKPOINT CHLORINATION CURVE |
- +-----------------------------------------------------------------------------+
- | Total Chlorine |
- | Residual |
- | (mg/L) ^ Zone 4: |
- | | Free Available |
- | | Zone 2: Chlorine (1:1 Slope) |
- | | Combined Residual / |
- | | (Chloramines) / |
- | | /\ / |
- | | / \ / |
- | | / \ / |
- | | Zone 1: / \ / |
- | | Initial Demand / Zone 3: v Breakpoint Nadir |
- | | (Inorganics: Fe, Mn, H2S) Chloramine Destruction |
- | 0 +---------------------------+----------+------------------------> |
- | 0 5:1 7.6:1 - 10:1 |
- | Chlorine-to-Ammonia Ratio (by weight) |
- +-----------------------------------------------------------------------------+
- The Four Zones
Zone 1: Initial Chlorine Demand: Chlorine reacts immediately with easily oxidizable inorganic substances (ferrous iron Fe 2 + \text{Fe}^{2+} Fe 2 + , manganous manganese Mn 2 + \text{Mn}^{2+} Mn 2 + , nitrite NO 2 − \text{NO}_2^- NO 2 − , and hydrogen sulfide H 2 S \text{H}_2\text{S} H 2 S ). Chlorine is reduced to inert chloride ( Cl − \text{Cl}^- Cl − ); no chlorine residual is established .
Zone 2: Formation of Chloramines (Combined Chlorine): Once inorganic demand is met, chlorine reacts with ammonia nitrogen ( NH 3 \text{NH}_3 NH 3 ) to form inorganic chloramines : NH 3 + HOCl → NH 2 Cl (Monochloramine) + H 2 O \text{NH}_3 + \text{HOCl} \rightarrow \text{NH}_2\text{Cl (Monochloramine)} + \text{H}_2\text{O} NH 3 + HOCl → NH 2 Cl (Monochloramine) + H 2 O NH 2 Cl + HOCl → NHCl 2 (Dichloramine) + H 2 O \text{NH}_2\text{Cl} + \text{HOCl} \rightarrow \text{NHCl}_2\text{ (Dichloramine)} + \text{H}_2\text{O} NH 2 Cl + HOCl → NHCl 2 (Dichloramine) + H 2 O NHCl 2 + HOCl → NCl 3 (Trichloramine) + H 2 O \text{NHCl}_2 + \text{HOCl} \rightarrow \text{NCl}_3\text{ (Trichloramine)} + \text{H}_2\text{O} NHCl 2 + HOCl → NCl 3 (Trichloramine) + H 2 O Measured total chlorine residual rises in direct proportion to chemical dosage. The residual in Zone 2 exists entirely as combined chlorine .
Zone 3: Destruction of Chloramines (The Breakpoint Transition): As the chlorine-to-ammonia nitrogen ratio increases beyond 5 : 1 5:1 5 : 1 toward 7.6 : 1 to 10 : 1 7.6:1 \text{ to } 10:1 7.6 : 1 to 10 : 1 by weight , free hypochlorous acid begins oxidizing chloramines, converting combined nitrogen into inert nitrogen gas ( N 2 ↑ \text{N}_2\uparrow N 2 ↑ ), nitrous oxide ( N 2 O \text{N}_2\text{O} N 2 O ), and hydrochloric acid: 2 NH 2 Cl + HOCl → N 2 ↑ + 3 HCl + H 2 O 2\text{NH}_2\text{Cl} + \text{HOCl} \rightarrow \text{N}_2\uparrow + 3\text{HCl} + \text{H}_2\text{O} 2 NH 2 Cl + HOCl → N 2 ↑ + 3 HCl + H 2 O During this phase, additional chlorine feed destroys existing chloramines, causing the measured residual to plunge sharply toward zero. The lowest point on this curve is the breakpoint nadir . (Operators who observe falling chlorine residuals despite increasing feed pumps are caught in Zone 3!)
Zone 4: Free Available Residual Chlorination: Once all ammonia is fully oxidized at the breakpoint, all further chlorine added remains uncombined as Free Available Chlorine ( HOCl + OCl − \text{HOCl} + \text{OCl}^- HOCl + OCl − ). The residual rises linearly on a 1 : 1 1:1 1 : 1 ratio ( 45 ∘ 45^\circ 4 5 ∘ slope) with applied dosage.
Disinfection Byproducts (DBPs) & Regulatory Standards
When free chlorine contacts naturally occurring humic and fulvic organic matter (TOC), it reacts to form carcinogenic Disinfection Byproducts (DBPs) governed under OAR 333-061-0036 (Stage 1 & Stage 2 DBPR):
1. Total Trihalomethanes (TTHMs) — Maximum Contaminant Level: 0.080 mg/L 0.080 \text{ mg/L} 0.080 mg/L ( 80 μ g/L 80 \ \mu\text{g/L} 80 μ g/L )
TTHMs comprise four halogenated methanes: chloroform ( CHCl 3 \text{CHCl}_3 CHCl 3 ), bromodichloromethane ( CHBrCl 2 \text{CHBrCl}_2 CHBrCl 2 ), dibromochloromethane ( CHBr 2 Cl \text{CHBr}_2\text{Cl} CHBr 2 Cl ), and bromoform ( CHBr 3 \text{CHBr}_3 CHBr 3 ). TTHM formation increases with high TOC, high water temperature, long water age, and elevated pH.
2. Five Haloacetic Acids (HAA5) — Maximum Contaminant Level: 0.060 mg/L 0.060 \text{ mg/L} 0.060 mg/L ( 60 μ g/L 60 \ \mu\text{g/L} 60 μ g/L )
HAA5 represents the sum of monochloroacetic , dichloroacetic , trichloroacetic , monobromoacetic , and dibromoacetic acids. Unlike TTHMs, HAA5 formation is favored at lower (acidic) pH.
3. Maximum Residual Disinfectant Levels (MRDLs)
To prevent systemic health risks and excessive DBP creation, the EPA and OHA enforce maximum residual disinfectant levels:
Free Chlorine & Chloramines: MRDL = 4.0 mg/L 4.0 \text{ mg/L} 4.0 mg/L (running annual average).
Chlorine Dioxide: MRDL = 0.8 mg/L 0.8 \text{ mg/L} 0.8 mg/L .
Compliance Methodology: Locational Running Annual Average (LRAA)
Compliance is not evaluated against system-wide averages. Under Stage 2 DBPR, utilities must calculate a Locational Running Annual Average (LRAA) quarterly for each individual monitoring location in the distribution system. If any single monitoring point exceeds 0.080 mg/L 0.080 \text{ mg/L} 0.080 mg/L for TTHMs or 0.060 mg/L 0.060 \text{ mg/L} 0.060 mg/L for HAA5 across four consecutive quarters, the system is in violation.
The C T CT CT Concept, Baffling Factors & Step-by-Step Calculations
Pathogen inactivation kinetics are governed by Chick's Law and the C T CT CT concept : C T = C × T 10 CT = C \times T_{10} CT = C × T 10
C C C : Disinfectant residual concentration ( mg/L \text{mg/L} mg/L ) measured at the exit of the contact chamber.
T 10 T_{10} T 10 : Effective contact time (minutes) required for 10 % 10\% 10% of the entering water to pass through the basin (meaning 90 % 90\% 90% of the water remains in the basin for at least time T 10 T_{10} T 10 ).
Baffling Factors ( B F BF BF )
Because tanks experience hydraulic short-circuiting, effective contact time ( T 10 T_{10} T 10 ) is significantly less than theoretical hydraulic detention time ( D T DT D T ). It is calculated using a Baffling Factor ( B F BF BF ) determined by empirical tracer studies: D T = Clearwell Volume (gal) Peak Flow Rate (gpm) T 10 = D T × B F DT = \frac{\text{Clearwell Volume (gal)}}{\text{Peak Flow Rate (gpm)}} \qquad T_{10} = DT \times BF D T = Peak Flow Rate (gpm) Clearwell Volume (gal) T 10 = D T × BF
- Baffling Condition Baffling Factor ( B F BF BF ) Physical Description of Tank Geometry
- Unbaffled (Very Poor) 0.1 0.1 0.1 Plain tank, single open inlet and outlet pipe, rapid short-circuiting
- Poor 0.3 0.3 0.3 Single baffle wall, unbaffled inlet or outlet, substantial dead space
- Average 0.5 0.5 0.5 Inlet and outlet baffles, minimal internal directional baffling
- Superior 0.7 0.7 0.7 Serpentine baffling channels, internal turning vanes, perforated diffusers
Perfect Plug Flow 1.0 1.0 1.0 Long pipeline contactor ( L : W > 40 : 1 L:W > 40:1 L : W > 40 : 1 ), zero short-circuiting
Treatment Technique Log-Credits
Under the Surface Water Treatment Rule, conventional filtration plants receive physical removal credits of 2.5 -log 2.5\text{-log} 2.5 -log for Giardia and 2.0 -log 2.0\text{-log} 2.0 -log for viruses if Combined Filter Effluent turbidity standards are met. Chemical disinfection must supply the remaining inactivation:
Remaining Disinfection Target for Conventional Plants: 0.5 -log 0.5\text{-log} 0.5 -log Giardia and 2.0 -log 2.0\text{-log} 2.0 -log virus inactivation.
Direct Filtration Plants: Receive 2.0 -log 2.0\text{-log} 2.0 -log Giardia credit, requiring chemical disinfection to achieve 1.0 -log 1.0\text{-log} 1.0 -log Giardia and 3.0 -log 3.0\text{-log} 3.0 -log virus inactivation.
Comprehensive Step-by-Step Worked C T CT CT Problem
Facility Operational Data:
- Clearwell Volume: 600 , 000 gallons 600,000 \text{ gallons} 600 , 000 gallons
- Peak Plant Flow: 4 , 000 gpm 4,000 \text{ gpm} 4 , 000 gpm
- Baffling Classification: Superior serpentine baffling ( B F = 0.7 BF = 0.7 BF = 0.7 )
Water Quality Conditions: pH = 7.5 \text{pH} = 7.5 pH = 7.5 , Temperature = 10 ∘ C \text{Temperature} = 10^\circ\text{C} Temperature = 1 0 ∘ C
Measured Effluent Free Chlorine Residual ( C C C ): 1.5 mg/L 1.5 \text{ mg/L} 1.5 mg/L
Step 1: Calculate Theoretical Detention Time ( D T DT D T ) D T = Volume Peak Flow = 600 , 000 gal 4 , 000 gpm = 150 minutes DT = \frac{\text{Volume}}{\text{Peak Flow}} = \frac{600,000 \text{ gal}}{4,000 \text{ gpm}} = 150 \text{ minutes} D T = Peak Flow Volume = 4 , 000 gpm 600 , 000 gal = 150 minutes
Step 2: Calculate Effective Contact Time ( T 10 T_{10} T 10 ) T 10 = D T × B F = 150 min × 0.7 = 105 minutes T_{10} = DT \times BF = 150 \text{ min} \times 0.7 = 105 \text{ minutes} T 10 = D T × BF = 150 min × 0.7 = 105 minutes
Step 3: Calculate Actual Achieved C T CT CT ( C T actual CT_{\text{actual}} C T actual ) C T actual = C × T 10 = 1.5 mg/L × 105 min = 157.5 mg ⋅ min/L CT_{\text{actual}} = C \times T_{10} = 1.5 \text{ mg/L} \times 105 \text{ min} = 157.5 \text{ mg}\cdot\text{min/L} C T actual = C × T 10 = 1.5 mg/L × 105 min = 157.5 mg ⋅ min/L
Step 4: Compare with EPA SWTR Lookup Tables for Giardia
The EPA table for 3-log Giardia inactivation by free chlorine at 10 ∘ C 10^\circ\text{C} 1 0 ∘ C lists residuals in 0.2 mg/L steps. Round the measured 1.5 mg/L up to 1.6 mg/L, the conservative choice. At pH 7.5:
Required C T CT CT for 3.0 -log 3.0\text{-log} 3.0 -log Giardia inactivation = 144 mg ⋅ min/L 144 \text{ mg}\cdot\text{min/L} 144 mg ⋅ min/L
Required C T CT CT for the 0.5 -log 0.5\text{-log} 0.5 -log Giardia still needed after conventional filtration = 144 ÷ 6 = 24 mg ⋅ min/L 144 \div 6 = 24 \text{ mg}\cdot\text{min/L} 144 ÷ 6 = 24 mg ⋅ min/L Inactivation Ratio = C T actual C T required = 157.5 24 ≈ 6.6 \text{Inactivation Ratio} = \frac{CT_{\text{actual}}}{CT_{\text{required}}} = \frac{157.5}{24} \approx 6.6 Inactivation Ratio = C T required C T actual = 24 157.5 ≈ 6.6
Because the inactivation ratio is well above 1.0, the clearwell easily provides the required 0.5-log credit. It in fact achieves more than 3-log Giardia inactivation by chemical disinfection alone: Log inactivation = 3 × 157.5 144 ≈ 3.3 -log \text{Log inactivation} = 3 \times \frac{157.5}{144} \approx 3.3\text{-log} Log inactivation = 3 × 144 157.5 ≈ 3.3 -log
Step 5: Verify Enteric Virus Inactivation
EPA tables specify that at 10 ∘ C 10^\circ\text{C} 1 0 ∘ C and pH 6.0 − 9.0 \text{pH } 6.0-9.0 pH 6.0 − 9.0 , a free chlorine C T CT CT of only 6.0 mg ⋅ min/L 6.0 \text{ mg}\cdot\text{min/L} 6.0 mg ⋅ min/L is required for 4.0 -log 4.0\text{-log} 4.0 -log virus inactivation. Virus Inactivation Ratio = 157.5 mg ⋅ min/L 6.0 mg ⋅ min/L = 26.25 ≥ 1.0 \text{Virus Inactivation Ratio} = \frac{157.5 \text{ mg}\cdot\text{min/L}}{6.0 \text{ mg}\cdot\text{min/L}} = 26.25 \ge 1.0 Virus Inactivation Ratio = 6.0 mg ⋅ min/L 157.5 mg ⋅ min/L = 26.25 ≥ 1.0
Virus compliance is overwhelmingly satisfied.