16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids

Oregon Water and Wastewater Operator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification

1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees

2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal

2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates

3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins

3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)

4 Chapter 4: Source Water, Intakes and Wells

4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection

5 Chapter 5: Coagulation, Clarification and Filtration

5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration

6 Chapter 6: Drinking Water Disinfection

6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control

7 Chapter 7: Specialty Water Treatment and Residuals

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate

8 Chapter 8: Distribution System Infrastructure

8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating

9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality

9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs

10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons

10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons

11 Chapter 11: Biological Wastewater Treatment

11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems

12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control

13 Chapter 13: Solids Handling and Biosolids

13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503

14 Chapter 14: Wastewater Collection Systems and Pumping

14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety

15 Chapter 15: Collection System Rehabilitation and Overflow Control

15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control

16 Chapter 16: Laboratory Procedures and Water Quality Testing

16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting

17 Chapter 17: Equipment, Electrical Systems and Maintenance

17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA

18 Chapter 18: Applied Water and Wastewater Mathematics

18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower

19 Chapter 19: Utility Safety

19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules

20 Chapter 20: Emergency Preparedness, Security and Utility Management

20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management

16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids

Key Takeaways Explain This Topic AI

Biochemical Oxygen Demand (BOD5) measures the oxygen consumed by aerobic microorganisms degrading organic matter over 5 days at 20.0 ± 1.0°C in the dark, using nutrient-buffered dilution water and seed organisms.

Valid BOD5 tests require an initial-to-final DO depletion of at least 2.0 mg/L, a minimum final residual DO of 1.0 mg/L, and a dilution water blank depletion not exceeding 0.20 mg/L.

Chemical Oxygen Demand (COD) utilizes potassium dichromate in boiling concentrated sulfuric acid with a silver catalyst at 150°C for 2 hours to rapidly oxidize virtually all organic matter, yielding typical COD:BOD5 ratios of 1.5:1 to 2.5:1.

Total Suspended Solids (TSS) is determined gravimetrically using Whatman 934-AH glass fiber filters dried at 103–105°C; Volatile Suspended Solids (VSS) measures organic biological solids ignited in a muffle furnace at 550 ± 50°C.

Settleable solids are measured directly in an Imhoff cone after 60 minutes of settling (45 min settle, wall rotation, 15 min settle), providing primary clarifier performance metrics in mL/L.

Last updated: October 2026

8.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids

Municipal wastewater treatment plants operate to protect receiving streams and groundwater aquifers from organic over-enrichment, solids sedimentation, and severe dissolved oxygen depletion. To evaluate treatment performance and enforce compliance with National Pollutant Discharge Elimination System (NPDES) permits issued by the Oregon Department of Environmental Quality (DEQ) under OAR Chapter 340, Division 045 , wastewater operators must master standard analytical laboratory procedures.

Key compliance parameters include Biochemical Oxygen Demand ( BOD 5 \text{BOD}_5 BOD 5 ​ ), Carbonaceous Biochemical Oxygen Demand ( CBOD 5 \text{CBOD}_5 CBOD 5 ​ ), Chemical Oxygen Demand ( COD \text{COD} COD ), Total Suspended Solids ( TSS \text{TSS} TSS ), Volatile Suspended Solids ( VSS \text{VSS} VSS ), and Settleable Solids. Understanding the analytical mechanics, chemistry, QA/QC criteria, and mathematical formulations of these tests is fundamental to utility operations.

Biochemical Oxygen Demand (BOD5 & CBOD5) Testing

Biochemical Oxygen Demand ( BOD 5 \text{BOD}_5 BOD 5 ​ ) measures the quantity of dissolved oxygen consumed by living heterotrophic microorganisms while biochemically oxidizing decomposing organic carbon and oxidizable inorganic matter in wastewater. The standard test (Standard Methods 5210B) measures dissolved oxygen depletion over a 5-day incubation period in the dark at 20.0 ± 1.0 ∘ C 20.0 \pm 1.0^\circ\text{C} 20.0 ± 1. 0 ∘ C .

A 5-day incubation period was historically selected to reflect the maximum travel time of treated sewage down typical river basins before reaching the ocean. At 20 ∘ C 20^\circ\text{C} 2 0 ∘ C , a 5-day test captures approximately 65 % to 70 % 65\% \text{ to } 70\% 65% to 70% of the total ultimate carbonaceous biochemical oxygen demand ( BOD u \text{BOD}_u BOD u ​ ). Dissolved Oxygen (mg/L)

  • 9.0 ┌───────────
  • │\
  • │ \ Carbonaceous Demand (CBOD)
  • │ \ (Heterotrophic bacteria oxidize organic carbon)
  • 5.0 │ \────────────────┐
  • │ │\ Nitrogenous Demand (NBOD)
  • │ │ \ (Autotrophic nitrifiers oxidize NH3 -> NO3)
  • 1.0 │ │ \─────────────
  • 0.0 └────────────────────┴────────────────────► Time (Days)
  • 0 5 (Standard Test) 20 (Ultimate)
  • 1. Test Apparatus & Dilution Water Preparation

Samples are incubated in specialized 300 mL 300 \text{ mL} 300 mL glass BOD bottles featuring tapered ground-glass stoppers and flared necks. The flared lip must be filled with high-purity deionized water and sealed with a plastic cap to form a continuous water seal , preventing atmospheric oxygen from diffusing into the sample bottle during the 5-day test. Bottles are incubated inside a light-tight incubator to prevent photosynthetic algae from generating dissolved oxygen.

Because raw wastewater exerts far more oxygen demand (typically 150 to 400 mg/L 150 \text{ to } 400 \text{ mg/L} 150 to 400 mg/L ) than can be dissolved in water (maximum oxygen saturation is only ∼ 9.1 mg/L \sim 9.1 \text{ mg/L} ∼ 9.1 mg/L at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C ), samples must be diluted using nutrient-buffered dilution water . High-purity deionized water is aerated with filtered oil-free air to achieve saturation ( 8.0 to 9.0 mg/L 8.0 \text{ to } 9.0 \text{ mg/L} 8.0 to 9.0 mg/L DO) and dosed with 1.0 mL/L 1.0 \text{ mL/L} 1.0 mL/L each of four reagent solutions:

Phosphate Buffer Solution (pH 7.2) : Provides buffering capacity to neutralize organic metabolic acids produced during decomposition and maintains optimal neutral pH.

Magnesium Sulfate ( MgSO 4 \text{MgSO}_4 MgSO 4 ​ ) Solution : Provides essential magnesium ions.

Calcium Chloride ( CaCl 2 \text{CaCl}_2 CaCl 2 ​ ) Solution : Provides structural calcium ions.

Ferric Chloride ( FeCl 3 \text{FeCl}_3 FeCl 3 ​ ) Solution : Provides trace iron essential for bacterial respiratory enzymes.

2. Microbial Seeding & Inhibitors

Samples that contain an active, healthy microbial population (such as raw, untreated municipal sewage or primary clarifier effluent) do not require supplemental seeding. However, samples that have undergone disinfection (chlorination/UV), industrial discharges, high-temperature processes, or membrane filtration lack viable heterotrophic bacteria. These samples must be seeded with an active biological inoculant—such as settled domestic wastewater, unchlorinated secondary effluent, or commercially stabilized bacterial consortia (e.g., PolySeed®).

3. Carbonaceous BOD (CBOD5) & Nitrification Inhibition

In biologically treated secondary effluents, autotrophic nitrifying bacteria ( Nitrosomonas and Nitrobacter ) proliferate. These organisms oxidize ammonia ( NH 4 + \text{NH}_4^+ NH 4 + ​ ) to nitrite ( NO 2 − \text{NO}_2^- NO 2 − ​ ) and nitrate ( NO 3 − \text{NO}_3^- NO 3 − ​ ), consuming 4.57 mg of O 2 4.57 \text{ mg of } \text{O}_2 4.57 mg of O 2 ​ per mg of ammonia-nitrogen oxidized :

2 NH 4 + + 3 O 2 → Nitrosomonas 2 NO 2 − + 4 H + + 2 H 2 O 2\text{NH}_4^+ + 3\text{O}_2 \xrightarrow{\text{Nitrosomonas}} 2\text{NO}_2^- + 4\text{H}^+ + 2\text{H}_2\text{O} 2 NH 4 + ​ + 3 O 2 ​ Nitrosomonas ​ 2 NO 2 − ​ + 4 H + + 2 H 2 ​ O 2 NO 2 − + O 2 → Nitrobacter 2 NO 3 − 2\text{NO}_2^- + \text{O}_2 \xrightarrow{\text{Nitrobacter}} 2\text{NO}_3^- 2 NO 2 − ​ + O 2 ​ Nitrobacter ​ 2 NO 3 − ​

This exertion of Nitrogenous Biochemical Oxygen Demand (NBOD) can falsely suggest treatment plant failure when the facility is actually achieving advanced biological nitrification. To isolate carbonaceous organic demand, Oregon DEQ permits often specify CBOD 5 \text{CBOD}_5 CBOD 5 ​ . The analyst adds a chemical nitrification inhibitor— TCMP (2-chloro-6-(trichloromethyl) pyridine) or ATU (allylthiourea)—which selectively inactivates Nitrosomonas enzymes without harming heterotrophic carbon-oxidizing bacteria.

4. QA/QC Criteria for Valid BOD5 Determinations

Under Standard Methods 5210B , strict quality control criteria must be satisfied for a test run to be legally defensible:

Dilution Water Blank : Dilution water with no sample must experience a DO depletion of ≤ 0.20 mg/L \le 0.20 \text{ mg/L} ≤ 0.20 mg/L after 5 days (ideally ≤ 0.10 mg/L \le 0.10 \text{ mg/L} ≤ 0.10 mg/L ). Greater depletion indicates contaminated DI water, dirty glassware, or contaminated reagents.

Glucose-Glutamic Acid (GGA) Standard : A reference solution containing 150 mg/L 150 \text{ mg/L} 150 mg/L reagent-grade glucose and 150 mg/L 150 \text{ mg/L} 150 mg/L glutamic acid must be analyzed with each batch. A 2.0 % 2.0\% 2.0% dilution ( 6.0 mL 6.0 \text{ mL} 6.0 mL of GGA in a 300 mL 300 \text{ mL} 300 mL bottle) must yield a 5-day BOD of 198 ± 30.5 mg/L 198 \pm 30.5 \text{ mg/L} 198 ± 30.5 mg/L (acceptable range: 167.5 to 228.5 mg/L 167.5 \text{ to } 228.5 \text{ mg/L} 167.5 to 228.5 mg/L ). This validates seed viability and analytical technique.

Depletion Criterion : A sample dilution is valid only if the initial-to-final DO depletion is at least ≥ 2.0 mg/L \ge 2.0 \text{ mg/L} ≥ 2.0 mg/L .

Residual Criterion : A sample dilution is valid only if the final DO remaining on Day 5 is at least ≥ 1.0 mg/L \ge 1.0 \text{ mg/L} ≥ 1.0 mg/L .

5. BOD Calculations

For an unseeded sample : BOD 5 (mg/L) = DO 0 − DO 5 P \text{BOD}_5 \text{ (mg/L)} = \frac{\text{DO}_0 - \text{DO}_5}{P} BOD 5 ​ (mg/L) = P DO 0 ​ − DO 5 ​ ​ Where DO 0 \text{DO}_0 DO 0 ​ is initial DO (mg/L), DO 5 \text{DO}_5 DO 5 ​ is final DO on Day 5 (mg/L), and P P P is the decimal volumetric fraction of sample in the bottle ( P = Sample Volume (mL) 300 mL P = \frac{\text{Sample Volume (mL)}}{300 \text{ mL}} P = 300 mL Sample Volume (mL) ​ ).

For a seeded sample : BOD 5 (mg/L) = ( DO 0 − DO 5 ) − ( B 0 − B 5 ) f P \text{BOD}_5 \text{ (mg/L)} = \frac{(\text{DO}_0 - \text{DO}_5) - (B_0 - B_5)f}{P} BOD 5 ​ (mg/L) = P ( DO 0 ​ − DO 5 ​ ) − ( B 0 ​ − B 5 ​ ) f ​ Where ( B 0 − B 5 ) (B_0 - B_5) ( B 0 ​ − B 5 ​ ) is the DO depletion in the seed control blank, and f f f is the ratio of seed volume in the sample bottle to seed volume in the seed blank ( f = Seed in Sample (mL) Seed in Blank (mL) f = \frac{\text{Seed in Sample (mL)}}{\text{Seed in Blank (mL)}} f = Seed in Blank (mL) Seed in Sample (mL) ​ ). If multiple dilutions meet the depletion and residual criteria, their calculated values are averaged.

Chemical Oxygen Demand (COD)

Chemical Oxygen Demand ( COD \text{COD} COD ) measures the total oxygen equivalent required to chemically oxidize all organic matter in a wastewater sample using a powerful chemical oxidant under harsh thermal and acidic conditions (Standard Methods 5220).

Chemistry of Digestion

The standard closed reflux micro-method uses potassium dichromate ( K 2 Cr 2 O 7 \text{K}_2\text{Cr}_2\text{O}_7 K 2 ​ Cr 2 ​ O 7 ​ ) in boiling 50 % 50\% 50% concentrated sulfuric acid ( H 2 SO 4 \text{H}_2\text{SO}_4 H 2 ​ SO 4 ​ ) . The sample and reagents are sealed in heavy-walled glass culture tubes and digested in a dry heating block at 150 ± 2 ∘ C 150 \pm 2^\circ\text{C} 150 ± 2 ∘ C for 2 hours :

Organics + Cr 2 O 7 2 − + 8 H + → Ag 2 SO 4 , 150 ∘ C 2 Cr 3 + + 4 H 2 O + Carbon Dioxide \text{Organics} + \text{Cr}_2\text{O}_7^{2-} + 8\text{H}^+ \xrightarrow{\text{Ag}_2\text{SO}_4, 150^\circ\text{C}} 2\text{Cr}^{3+} + 4\text{H}_2\text{O} + \text{Carbon Dioxide} Organics + Cr 2 ​ O 7 2 − ​ + 8 H + Ag 2 ​ SO 4 ​ , 15 0 ∘ C ​ 2 Cr 3 + + 4 H 2 ​ O + Carbon Dioxide

Silver Sulfate ( Ag 2 SO 4 \text{Ag}_2\text{SO}_4 Ag 2 ​ SO 4 ​ ) Catalyst : Straight-chain aliphatic hydrocarbons are resistant to oxidation; silver sulfate acts as a catalyst to ensure complete destruction.

Mercuric Sulfate ( HgSO 4 \text{HgSO}_4 HgSO 4 ​ ) Interference Suppressor : Chloride ions ( Cl − \text{Cl}^- Cl − ) are readily oxidized by dichromate, which would generate enormous false-positive COD values. Mercuric sulfate complexes chloride ions to form soluble, unoxidized mercuric chloride complexes ( [ HgCl 4 ] 2 − [\text{HgCl}_4]^{2-} [ HgCl 4 ​ ] 2 − ).

COD Measurement & Ratios

Following digestion, COD is quantified either by back-titrating residual unreduced hexavalent chromium ( Cr 6 + \text{Cr}^{6+} Cr 6 + ) with ferrous ammonium sulfate (FAS) using ferroin indicator (sharp color change from blue-green to reddish-brown), or spectrophotometrically at 600 nm 600 \text{ nm} 600 nm (measuring green trivalent chromium Cr 3 + \text{Cr}^{3+} Cr 3 + formed).

Parameter Biochemical Oxygen Demand ( BOD 5 \text{BOD}_5 BOD 5 ​ ) Chemical Oxygen Demand ( COD \text{COD} COD )

Oxidizing Agent Living heterotrophic bacteria + Dissolved O 2 \text{O}_2 O 2 ​ Potassium dichromate ( K 2 Cr 2 O 7 \text{K}_2\text{Cr}_2\text{O}_7 K 2 ​ Cr 2 ​ O 7 ​ ) + Hot H 2 SO 4 \text{H}_2\text{SO}_4 H 2 ​ SO 4 ​

Incubation / Time 5 days at 20.0 ± 1.0 ∘ C 20.0 \pm 1.0^\circ\text{C} 20.0 ± 1. 0 ∘ C in dark 2 hours at 150 ± 2 ∘ C 150 \pm 2^\circ\text{C} 150 ± 2 ∘ C

Oxidation Scope Biodegradable organic matter only ( ∼ 65 − 70 % BOD u \sim 65-70\% \text{ BOD}_u ∼ 65 − 70% BOD u ​ ) Virtually all organic matter ( ∼ 95 − 100 % \sim 95-100\% ∼ 95 − 100% complete)

Toxicity Interference Highly sensitive to heavy metals, chlorine, toxins Minimal sensitivity; biological toxins do not halt chemical oxidation

Typical Municipal Raw 150 to 350 mg/L 150 \text{ to } 350 \text{ mg/L} 150 to 350 mg/L 300 to 700 mg/L 300 \text{ to } 700 \text{ mg/L} 300 to 700 mg/L

Operational Role Official NPDES permit compliance Rapid same-day process control and loading diagnostics

In typical domestic municipal wastewater, the ratio of COD : BOD 5 \text{COD} : \text{BOD}_5 COD : BOD 5 ​ ranges from 1.5 : 1 to 2.5 : 1 1.5 : 1 \text{ to } 2.5 : 1 1.5 : 1 to 2.5 : 1 . A sudden spike in this ratio ( > 3.0 : 1 > 3.0 : 1 > 3.0 : 1 ) indicates the arrival of refractory industrial waste, synthetic surfactants, petroleum hydrocarbons, or toxic chemicals that cannot be broken down biologically.

Total Suspended Solids (TSS) & Volatile Suspended Solids (VSS)

Solids in wastewater exist in physical fractions categorized by filterability and volatility. Solids retained on a standard filter are suspended , while those passing through are dissolved . ┌────────────────────────────────────────────────────────┐

  • │ Total Solids (TS) - Dried at 103-105°C │
  • ├────────────────────────────┬───────────────────────────┤
  • │ Total Dissolved Solids │ Total Suspended Solids │
  • │ (TDS) - Passes 1.5 µm │ (TSS) - Retained on 1.5 µm│
  • └────────────────────────────┼───────────────────────────┤
  • │ Volatile Suspended Solids │
  • │ (VSS) - Burned at 550°C │
  • │ (Active biological mass) │
  • ├───────────────────────────┤
  • │ Fixed Suspended Solids │
  • │ (FSS) - Inert mineral ash │
  • └───────────────────────────┘
  • 1. Total Suspended Solids (TSS) Procedure (Standard Methods 2540D)

TSS represents the non-filterable particulate fraction retained on a glass fiber filter under vacuum:

Filter Preparation : A binder-free glass fiber filter disk ( Whatman 934-AH , 1.5 μ m 1.5 \ \mu\text{m} 1.5 μ m nominal pore size) is placed wrinkled-side up in a Buchner funnel or Gooch crucible, washed with three 20 mL 20 \text{ mL} 20 mL volumes of reagent-grade deionized water under vacuum, dried in a laboratory drying oven at 103 to 105 ∘ C 103 \text{ to } 105^\circ\text{C} 103 to 10 5 ∘ C for 1 hour, cooled in a desiccator, and weighed on an analytical balance sensitive to 0.1 mg 0.1 \text{ mg} 0.1 mg ( 0.0001 g 0.0001 \text{ g} 0.0001 g ) . This yields the tare weight ( B B B grams).

Filtration : A well-mixed, representative sample aliquot ( V mL V \text{ mL} V mL ) is vacuum-filtered through the pre-weighed disk. The volume selected must yield a dry residue mass between 2.5 mg 2.5 \text{ mg} 2.5 mg and 200 mg 200 \text{ mg} 200 mg . The filter and funnel walls are rinsed with three 10 mL 10 \text{ mL} 10 mL portions of deionized water to wash away residual dissolved salts.

Drying : The filter is dried in the oven at 103 to 105 ∘ C 103 \text{ to } 105^\circ\text{C} 103 to 10 5 ∘ C for a minimum of 1 hour (or until constant weight is achieved). This temperature evaporates all liquid water without volatilizing organic solids or decomposing thermally unstable mineral salts.

Cooling & Weighing : The filter is placed in a desiccator containing active blue cobalt-indicating silica gel desiccant. Desiccation cools the filter to ambient balance temperature while preventing hygroscopic absorption of atmospheric humidity. The cooled filter is weighed to obtain gross weight ( A A A grams).

TSS (mg/L) = ( A − B ) × 1 , 000 , 000 V (mL) \text{TSS (mg/L)} = \frac{(A - B) \times 1,000,000}{V \text{ (mL)}} TSS (mg/L) = V (mL) ( A − B ) × 1 , 000 , 000 ​ Where A A A is weight of filter + dried residue (g), B B B is tare weight of clean filter (g), and V V V is sample volume filtered (mL).

2. Volatile Suspended Solids (VSS) Procedure (Standard Methods 2540E)

VSS quantifies the organic, biologically active fraction of suspended solids:

The dry filter and residue from the TSS determination ( A A A grams) are placed in a muffle furnace preheated to 550 ± 50 ∘ C 550 \pm 50^\circ\text{C} 550 ± 5 0 ∘ C for 15 to 20 minutes 15 \text{ to } 20 \text{ minutes} 15 to 20 minutes .

At 550 ∘ C 550^\circ\text{C} 55 0 ∘ C , all combustible organic carbonaceous material ignites and oxidizes to carbon dioxide and water vapor, while inorganic mineral salts remain behind as inert ash.

The filter is partially cooled in air, transferred to a desiccator to reach room temperature, and weighed ( C C C grams).

VSS (mg/L) = ( A − C ) × 1 , 000 , 000 V (mL) \text{VSS (mg/L)} = \frac{(A - C) \times 1,000,000}{V \text{ (mL)}} VSS (mg/L) = V (mL) ( A − C ) × 1 , 000 , 000 ​ FSS (Fixed Suspended Solids, mg/L) = TSS − VSS = ( C − B ) × 1 , 000 , 000 V (mL) \text{FSS (Fixed Suspended Solids, mg/L)} = \text{TSS} - \text{VSS} = \frac{(C - B) \times 1,000,000}{V \text{ (mL)}} FSS (Fixed Suspended Solids, mg/L) = TSS − VSS = V (mL) ( C − B ) × 1 , 000 , 000 ​

Operational Importance of VSS in Activated Sludge

In activated sludge process control, operators measure Mixed Liquor Suspended Solids (MLSS) and Mixed Liquor Volatile Suspended Solids (MLVSS). The ratio of MLVSS MLSS \frac{\text{MLVSS}}{\text{MLSS}} MLSS MLVSS ​ reflects the proportion of active microbial biomass versus inert mineral debris (sand, clay, calcium precipitates) in the aeration basin. A healthy activated sludge plant maintains an MLVSS/MLSS ratio of 0.70 to 0.85 0.70 \text{ to } 0.85 0.70 to 0.85 ( 70 % to 85 % 70\% \text{ to } 85\% 70% to 85% ) . A declining ratio indicates mineral accumulation, alerting the operator to increase waste activated sludge (WAS) pumping rates.

Settleable Solids & Imhoff Cone Analysis

Settleable solids measure the volume of suspended particulate matter that settles to the bottom of a quiescent fluid column under gravity within a 1-hour period (Standard Methods 2540F). This test serves as a rapid, direct physical indicator of primary clarifier performance and solids-liquid separation efficiency.

Standard Procedure

A standardized 1.0 L 1.0 \text{ L} 1.0 L Imhoff cone (a steep-walled conical glass or transparent polycarbonate vessel with inverted milliliter graduations at the tip) is filled exactly to the 1.0 L 1.0 \text{ L} 1.0 L mark with well-mixed raw wastewater, mixed liquor, or treated effluent.

The sample settles undisturbed for 45 minutes .

At 45 minutes, a glass rod or the cone itself is gently spun or rotated along its vertical axis to dislodge solids adhering to the sloped conical sides.

The solids settle for an additional 15 minutes (total settling time: 60 minutes ).

The volume of settled solids compacted into the conical tip is read directly in mL/L \text{mL/L} mL/L .

Process Control Applications

Primary Clarifier Performance : Raw domestic municipal influent typically contains 5.0 to 20.0 mL/L 5.0 \text{ to } 20.0 \text{ mL/L} 5.0 to 20.0 mL/L of settleable solids. An efficiently operating primary clarifier removes 95 % to 99 % 95\% \text{ to } 99\% 95% to 99% of settleable solids and 50 % to 65 % 50\% \text{ to } 65\% 50% to 65% of Total Suspended Solids.

Secondary Clarifier Troubleshooting : Settleable solids in secondary effluent should be negligible ( < 0.1 to 0.5 mL/L < 0.1 \text{ to } 0.5 \text{ mL/L} < 0.1 to 0.5 mL/L ). Higher readings indicate secondary clarifier solids washout, hydraulic overloading, or activated sludge bulking.