Study guide

16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation

Oregon Water and Wastewater Operator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification

1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees

2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal

2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates

3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins

3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)

4 Chapter 4: Source Water, Intakes and Wells

4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection

5 Chapter 5: Coagulation, Clarification and Filtration

5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration

6 Chapter 6: Drinking Water Disinfection

6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control

7 Chapter 7: Specialty Water Treatment and Residuals

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate

8 Chapter 8: Distribution System Infrastructure

8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating

9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality

9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs

10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons

10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons

11 Chapter 11: Biological Wastewater Treatment

11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems

12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control

13 Chapter 13: Solids Handling and Biosolids

13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503

14 Chapter 14: Wastewater Collection Systems and Pumping

14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety

15 Chapter 15: Collection System Rehabilitation and Overflow Control

15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control

16 Chapter 16: Laboratory Procedures and Water Quality Testing

16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting

17 Chapter 17: Equipment, Electrical Systems and Maintenance

17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA

18 Chapter 18: Applied Water and Wastewater Mathematics

18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower

19 Chapter 19: Utility Safety

19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules

20 Chapter 20: Emergency Preparedness, Security and Utility Management

20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management

16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation

Key Takeaways Explain This Topic AI

Total nitrogen equals total Kjeldahl nitrogen (organic N plus ammonia) plus nitrite and nitrate; ammonia is measured by ion-selective electrode, phenate or salicylate color, or distillation.

Total phosphorus needs persulfate digestion before the ascorbic acid (molybdenum blue) test; skipping digestion measures only orthophosphate.

Alkalinity (mg/L as CaCO3) = mL of titrant × normality × 50,000 ÷ mL of sample, titrated to about pH 4.5; nitrifying basins are commonly kept above about 50 mg/L residual alkalinity.

Wastewater E. coli samples have an 8-hour holding time and are run by membrane filtration or enzyme-substrate MPN methods with dechlorinating bottles.

Whole effluent toxicity tests expose species such as Ceriodaphnia dubia and fathead minnows to effluent dilutions; compliance drinking water labs in Oregon must be accredited under ORELAP.

Last updated: October 2026

The Nitrogen Family

Test What it measures Common methods Process use

Ammonia-N (NH3-N) Ammonium plus free ammonia Ion-selective electrode (ISE); phenate or salicylate colorimetry; distillation and titration Influent load, nitrification performance, permit limits

Nitrite-N (NO2-N) Intermediate of nitrification Colorimetric (diazotization) A rising effluent nitrite flags incomplete nitrification or inhibition

Nitrate-N (NO3-N) End product of nitrification Cadmium reduction, ion chromatography, ISE Denitrification performance; clarifier rising-sludge risk

Total Kjeldahl nitrogen (TKN) Organic N plus ammonia Digestion, then ammonia measurement Total nitrogen calculations, biosolids nitrogen

Total nitrogen (TN) TKN + nitrite + nitrate Calculated, or persulfate digestion TN limits and TMDLs

Always report nitrogen species "as N" so results add up. A profile of ammonia, nitrite and nitrate along an aeration basin shows where nitrification is happening and whether alkalinity or DO is limiting.

Ammonia ISE tips : add the alkaline ionic-strength adjuster to raise pH above 11 (converting ammonium to ammonia gas the membrane can sense). Calibrate with standards that bracket the sample, stir at the same rate for every sample, and replace the membrane when the slope drifts.

Phosphorus

Orthophosphate (reactive phosphorus) is measured directly by the ascorbic acid method . Molybdate and antimony form a blue complex that is read on a spectrophotometer.

Total phosphorus requires persulfate digestion first, to convert polyphosphates and organic phosphorus to orthophosphate.

Process use : comparing ortho-P in anaerobic and aerobic zones confirms biological phosphorus release and uptake. Filtered versus unfiltered results show how much phosphorus leaves as particles, which tertiary filtration can capture.

Alkalinity

Alkalinity is the water's capacity to neutralize acid, measured by titrating with standardized sulfuric acid to an endpoint near pH 4.5 : Alkalinity (mg/L as CaCO 3 ) = mL titrant × N × 50,000 mL sample \text{Alkalinity (mg/L as CaCO}_3\text{)} = \frac{\text{mL titrant} \times N \times 50{,}000}{\text{mL sample}} Alkalinity (mg/L as CaCO 3 ​ ) = mL sample mL titrant × N × 50 , 000 ​

Example. A 100 mL sample takes 4.6 mL of 0.02 N H2SO4 to reach pH 4.5.

Alkalinity = 4.6 × 0.02 × 50,000 ÷ 100 = 46 mg/L as CaCO3

Nitrification destroys about 7.14 mg/L alkalinity per mg/L of ammonia-N oxidized. Low-alkalinity Oregon wastewaters can crash in pH, so many operators keep at least about 50 mg/L residual alkalinity in nitrifying basins. Track influent and effluent alkalinity daily when nitrification is required.

Effluent Bacteria

Sample handling : sterile bottles containing sodium thiosulfate for chlorinated effluent; ice; 8-hour holding time from collection to the start of analysis for wastewater coliform and E. coli .

Methods : membrane filtration on selective media, or enzyme-substrate tests (for example Colilert-18 with Quanti-Tray MPN). These are read as most probable number per 100 mL. Dilutions are needed for undisinfected samples.

Calculations : permits often use a geometric mean , the antilog of the average of the logs, for monthly limits. One high result raises a geometric mean far less than it raises an arithmetic mean.

Process Control Tests at the Bench

Settleometer (30-minute settling) and sludge volume index for activated sludge.

Oxygen uptake rate (OUR) and specific oxygen uptake rate (SOUR) : DO decline in a stirred, sealed sample over time, divided by volatile solids for SOUR. Used for activated sludge health and aerobic digester vector-attraction tests.

Microscopic examination for protozoa, filaments and floc structure.

Volatile acids and alkalinity for anaerobic digesters.

Whole Effluent Toxicity (WET)

WET tests measure the combined toxicity of effluent to living organisms:

Test type Typical species Endpoints

Acute Ceriodaphnia dubia (water flea), fathead minnow ( Pimephales promelas ) Survival over 48-96 hours; LC50 (concentration lethal to 50 percent)

Chronic C. dubia reproduction, fathead minnow growth, green algae growth NOEC (no observed effect concentration), IC25; chronic toxic units TUc = 100 ÷ NOEC (percent effluent)

A failed WET test usually triggers accelerated testing and a toxicity reduction evaluation to find the cause, such as ammonia, chlorine residual, metals or surfactants.

Lab Quality and Accreditation

Wastewater compliance analyses must use approved 40 CFR Part 136 methods, holding times and preservation, plus the QA/QC your permit requires: blanks, duplicates, spikes and calibration checks.

Drinking water compliance samples in Oregon go to laboratories accredited under the Oregon Environmental Laboratory Accreditation Program (ORELAP) , the OHA program under OAR 333-064. Cyanotoxin analyses, for example, must use an ORELAP-accredited lab or the DEQ laboratory.

Keep bench sheets, calibration logs and instrument maintenance records. They are legal records that support every DMR value.

Worked Example: Is There Enough Alkalinity to Nitrify?

Influent ammonia-N is 30 mg/L, the permit target is about 1 mg/L, and influent alkalinity is 220 mg/L as CaCO3.

  • Ammonia-N nitrified ≈ 30 − 1 = 29 mg/L
  • Alkalinity consumed ≈ 29 × 7.14 ≈ 207 mg/L as CaCO3
  • Alkalinity remaining ≈ 220 − 207 = 13 mg/L

That leftover is far below the residual many operators aim to keep (commonly about 50 mg/L or more), so pH would sag and nitrification would stall. Options include feeding alkalinity (lime, caustic, sodium bicarbonate or magnesium hydroxide), or adding an anoxic zone. Denitrification there recovers about half of the alkalinity used in nitrification.

Sample Preservation for Nutrients (40 CFR 136, Table II)

  • Test Preservation Maximum holding time
  • Ammonia-N, TKN, nitrate-nitrite, total phosphorus Cool to 6°C or below; H2SO4 to pH below 2 28 days
  • Nitrate or nitrite (unpreserved) Cool to 6°C or below 48 hours
  • Orthophosphate Filter within 15 minutes; cool to 6°C or below 48 hours

Acid-preserved samples are reported as nitrate plus nitrite, not as separate nitrate or nitrite results. Filter orthophosphate samples in the field, because cells keep taking up and releasing phosphate after collection.