Study guide
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement
Key Takeaways Explain This Topic AI
A small water system serves fewer than 151 connections and uses only groundwater or buys finished water; it needs a Small Water System (SWS) certified operator.
Water Distribution classes follow population served: 1 for up to 1,500, 2 for 1,501-15,000, 3 for 15,001-50,000 and 4 for 50,001 or more (Table 50).
Water Treatment classes come from Table 51 points: WT1 1-30, WT2 31-55, WT3 56-75 and WT4 76 or more (Table 52).
A Water Treatment 2 plant using conventional or direct filtration on surface water or GWUDI also carries the Filtration Endorsement classification; its DRC operator needs the endorsement unless already certified at WT Level 3 or higher.
Operators below the required level need a signed written protocol; contract DRC operators must be on call 24 hours a day, and DRC changes are reported to OHA within 30 days.
Last updated: October 2026
Which Systems Need a Certified Operator?
OHA's operator rules apply to community and non-transient non-community (NTNC) public water systems. The water supplier must at all times employ, contract with, or otherwise use an operator in Direct Responsible Charge (DRC) of every distribution system and every water treatment plant. The DRC operator must be available whenever decisions about treatment processes, water quality or water quantity that may affect public health are made (OAR 333-061-0225).
- Classification Rules (OAR 333-061-0220)
- Small water systems
A system is a small water system when it serves fewer than 151 service connections and either uses only groundwater or purchases finished water from another public water system. Its operator needs the Small Water System (SWS) certification, or any Level 1-4 certificate.
Water distribution: Table 50
- Classification Population served
- Water Distribution 1 1 to 1,500
- Water Distribution 2 1,501 to 15,000
- Water Distribution 3 15,001 to 50,000
- Water Distribution 4 50,001 or more
- Water treatment: Tables 51 and 52
Treatment classification applies when the system is not small and a plant treats for regulated contaminants. Table 51 assigns points for each characteristic. Selected values:
- Characteristic (Table 51) Points
- Size: population served (1 per 10,000) or average daily flow (1 per MGD), whichever is greater up to 30
- Source: groundwater / surface water or GWUDI 3 / 5
- Chlorination / ammonia-chloramination / UV / on-site generated chlorine / ozone 5 / 3 / 2 / 7 / 10
- Coagulant or polymer added 1 per chemical, max 5
- Mechanical rapid mix / mechanical flocculators 3 / 3
- Horizontal-flow rectangular basin / tube or plate settlers / upflow solids contact / DAF 5 / 10 / 15 / 10
Direct filtration / dual or mixed media / slow sand / membranes / pressure or greensand / diatomaceous earth 5 / 5 / 5 / 5 / 10 / 12
- Corrosion control with caustic soda / orthophosphate / soda ash 6 / 5 / 4
- Fluoridation / lime-soda softening / reverse osmosis and other special processes 5 / 20 / 15
- Residuals to lagoons / mechanical dewatering 5 / 5
- SCADA data only / partial control / complete control 1 / 3 / 5
Table 52 converts the total: WT1 = 1-30, WT2 = 31-55, WT3 = 56-75, WT4 = 76 or more.
Worked example
A conventional surface-water plant serves 30,000 people at 2.0 MGD. Its points add up as follows:
- Size: 3 (population gives 3, which is more than the 2 from flow)
- Surface source: 5
- Chlorination: 5
- Alum plus polymer: 2
- Mechanical rapid mix and mechanical flocculators: 3 + 3
- Rectangular sedimentation: 5
- Dual media filters: 5
- Caustic soda corrosion control: 6
- Fluoridation: 5
- Backwash residuals to lagoons: 5
- SCADA with partial control: 3
The total is 50 points, so the plant is WT2 . It uses conventional filtration on surface water, so the plant also carries the Filtration Endorsement classification.
The Filtration Endorsement (FE)
Under OAR 333-061-0220(4), the FE classification applies when a plant is classified Water Treatment 2 and uses conventional or direct filtration to treat surface water or groundwater under the direct influence of surface water (GWUDI). The operator designated in DRC of that plant must hold FE certification. The exception is an operator already certified at Water Treatment Level 3 or higher , who needs no endorsement. Qualifications for the endorsement are covered in the next section.
Important
The FE is triggered by the combination "WT2 + conventional or direct filtration." A WT3 or WT4 plant has no FE classification, because its DRC operator must already hold WT3 or WT4.
Operators Below the Required Level: Written Protocols
A supplier may use additional operators certified below the required level, but it must write a protocol for each one (OAR 333-061-0225(2)). The protocol:
- describes the operational decisions the operator may make;
- requires notifying the DRC operator after decisions affecting process control, water quality or quantity;
- states when and how the operator must consult the DRC operator;
- accounts for the operator's certification, skills and the expected operating conditions; and
is signed and dated by the DRC operator and the operator, and kept available for OHA inspection.
Reporting and Contract Operators
The supplier reports the DRC operator's name to OHA and must notify OHA within 30 days of any change, using the DRC designation form.
A supplier may contract with an individual certified operator, another water supplier or an organization (OAR 333-061-0230). A contracted DRC operator must be certified at or above the facility classification. The written contract must require the operator to be on call 24 hours every day and able to respond on site, and to take corrective action when MCLs are exceeded or minimum treatment is not maintained.
Contracts must be signed before any service begins and submitted to OHA within 30 days of signing. They are valid only while the operator's certification is current.
Every Operator's Duties (OAR 333-061-0232)
All operators must comply with any OHA order or investigation, ensure that every document filed with OHA is true and accurate, and immediately notify OHA when they observe a rule violation that may result in a public health hazard.