Study guide

1.2 DEQ Wastewater System Classification and Supervision Rules

Oregon Water and Wastewater Operator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification

1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees

2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal

2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates

3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins

3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)

4 Chapter 4: Source Water, Intakes and Wells

4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection

5 Chapter 5: Coagulation, Clarification and Filtration

5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration

6 Chapter 6: Drinking Water Disinfection

6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control

7 Chapter 7: Specialty Water Treatment and Residuals

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate

8 Chapter 8: Distribution System Infrastructure

8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating

9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality

9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs

10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons

10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons

11 Chapter 11: Biological Wastewater Treatment

11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems

12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control

13 Chapter 13: Solids Handling and Biosolids

13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503

14 Chapter 14: Wastewater Collection Systems and Pumping

14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety

15 Chapter 15: Collection System Rehabilitation and Overflow Control

15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control

16 Chapter 16: Laboratory Procedures and Water Quality Testing

16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting

17 Chapter 17: Equipment, Electrical Systems and Maintenance

17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA

18 Chapter 18: Applied Water and Wastewater Mathematics

18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower

19 Chapter 19: Utility Safety

19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules

20 Chapter 20: Emergency Preparedness, Security and Utility Management

20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management

1.2 DEQ Wastewater System Classification and Supervision Rules

Key Takeaways Explain This Topic AI

Treatment systems are classed I-IV by treatment type and design average dry weather flow (ADWF) in Table A; the highest-rated process sets the class, and DEQ may move a plant up or down for complexity.

Collection systems are Class I up to 1,500 design population, II from 1,501 to 15,000, III from 15,001 to 50,000 and IV above 50,000.

A Small Wastewater System is a Class I treatment type with under 500 design population or under 150 connections, and it may be supervised solely by an SWWS-certified operator.

Systems with ADWF of 0.075 MGD or more need full-time supervision (at least 30 hours a week); smaller systems may use part-time supervision under a written contract.

Shift supervisors may be one grade below the system class, owners must report supervisor changes within 30 days, and a system may not go more than 30 days without its required operator.

Last updated: October 2026

Why Classification Comes First

Every certification question about "who may run this plant" starts with the system classification . DEQ classifies each domestic wastewater treatment system and collection system, tells the owner the class in writing, and the owner must then have the system supervised by an operator holding a certificate of the same type (treatment or collection) at a grade equal to or greater than the class (OAR 340-049-0015 and -0020).

Treatment System Classes: Table A (OAR 340-049-0025)

DEQ does not use a point-rating score for wastewater plants. Table A assigns the class from the treatment type and the design average dry weather flow (ADWF) in million gallons per day (MGD):

  • Treatment type ADWF up to 1 MGD over 1 to 5 over 5 to 10 over 10
  • Lagoon, non-aerated I I I I
  • Lagoon, aerated I II II II
  • Biofiltration II II III III
  • Extended aeration II II III III
  • Conventional activated sludge II II III IV
  • Membrane bioreactor II II III IV

Activated sludge with separate fixed film; SBR, MBBR, integrated fixed film, oxidation ditch or other suspended growth media III III IV IV

  • Activated sludge with tertiary filtration (includes chemical phosphorus removal) III III IV IV
  • Activated sludge with biological nutrient removal III IV IV IV

Rules that travel with the table:

If more than one treatment type is used, the highest-rated type sets the class.

DEQ may classify a plant higher or lower than Table A if it is more or less complex than similar plants, if receiving-water conditions demand tighter control, or if it uses an approved process that is not listed. DEQ may also reclassify a collection system higher than its population would indicate.

An owner may appeal a classification through the variance procedure in OAR 340-049-0075.

Worked classification examples

A 3.2 MGD conventional activated sludge plant: the "over 1 to 5" column gives Class II .

The same process at 12 MGD: Class IV .

A 2.0 MGD plant with biological nutrient removal: Class IV , even though its flow is modest.

A 0.6 MGD aerated lagoon followed by a small UV system: the lagoon line sets Class I .

Collection System Classes (OAR 340-049-0020)

  • Collection class Design population served
  • Class I 1,500 or less
  • Class II 1,501 to 15,000
  • Class III 15,001 to 50,000
  • Class IV 50,001 or more

Design population can be an equivalent population. The rules base it on 70 gallons per person per day of ADWF or 0.17 lb BOD5 per person per day, whichever is greater (OAR 340-049-0010).

Small Wastewater Systems

A Small Wastewater System (SWWS) is a Class I treatment type serving fewer than 500 design population or fewer than 150 connections. It is designated in the permit, and an operator holding the single SWWS certificate may supervise it alone. DEQ's entry-level fact sheet notes that a qualifying small system can ask its permit compliance contact to be reclassified as an SWWS.

Supervision Requirements (OAR 340-049-0015)

Rule Requirement

ADWF of 0.075 MGD (75,000 gpd) or more Supervised full-time by one or more operators certified for the system type at or above its class. Full-time means at least 30 hours per week for an owner or city employee.

ADWF under 0.075 MGD Supervised part-time or full-time by a properly certified operator. A part-time contract must meet OAR 340-049-0070.

More than one daily shift A shift supervisor, if used, may be certified no more than one grade lower than the system class.

Availability The system supervisor need not be on site at all times but must be available and able to respond on site immediately.

Grade I Provisional May be designated to supervise a Class I system of the matching type.

Notification The owner reports supervisors to DEQ in writing (certificate type, grade, expiration) and reports replacement or re-designation within 30 days .

Vacancy A system may not be without its required operator for more than 30 days ; meanwhile an operator no more than one grade lower, authorized by the owner, must run it.

Time extension On written request the Director may extend the deadline. Extensions over 120 days need extraordinary circumstances or the class-increase criteria, and none may exceed 365 days.

The class-increase extension applies when DEQ raises a plant's class and the current supervisor has worked there at least one year, holds a certificate one grade below the new class, and the plant has had no Class I permit violations. The owner may then ask for 365 days so the operator can upgrade.

Part-time supervision contracts (OAR 340-049-0070)

A contract for part-time supervision of a small system must list the parties and their contact information; each supervising operator's certificate type, grade and expiration date; the contract start and end dates; the minimum number of site visits ; and each party's duties. It must also make a certified operator available to respond on site. The owner keeps the contract on file for DEQ review.

Who else must be certified?

Only the designated supervisor and any shift supervisor must hold certificates. Other staff working under a properly certified supervisor may certify voluntarily, and many employers require or reward it. DEQ's rules apply equally to engineers: an engineer designated as the system supervisor must be certified. Owners of permitted systems also pay an annual operator certification program support fee scaled to design ADWF (Table C). For example, the fee effective July 1, 2026 is $100 for systems under 0.075 MGD and $457 for 1.0-1.999 MGD.

Exam Traps

Table A uses design ADWF , not peak wet weather flow, and treatment type , not a point score.

A plant's class is driven by its most complex process. Adding biological nutrient removal can raise a small plant to Class III or IV.

The one-grade-lower allowance is for shift supervisors and for the 30-day vacancy period. It is never for the designated system supervisor.