4.1 Raw Water Sources, Intake Structures & Pretreatment

Oregon Water and Wastewater Operator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification

1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees

2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal

2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates

3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins

3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)

4 Chapter 4: Source Water, Intakes and Wells

4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection

5 Chapter 5: Coagulation, Clarification and Filtration

5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration

6 Chapter 6: Drinking Water Disinfection

6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control

7 Chapter 7: Specialty Water Treatment and Residuals

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate

8 Chapter 8: Distribution System Infrastructure

8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating

9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality

9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs

10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons

10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons

11 Chapter 11: Biological Wastewater Treatment

11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems

12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control

13 Chapter 13: Solids Handling and Biosolids

13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503

14 Chapter 14: Wastewater Collection Systems and Pumping

14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety

15 Chapter 15: Collection System Rehabilitation and Overflow Control

15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control

16 Chapter 16: Laboratory Procedures and Water Quality Testing

16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting

17 Chapter 17: Equipment, Electrical Systems and Maintenance

17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA

18 Chapter 18: Applied Water and Wastewater Mathematics

18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower

19 Chapter 19: Utility Safety

19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules

20 Chapter 20: Emergency Preparedness, Security and Utility Management

20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management

4.1 Raw Water Sources, Intake Structures & Pretreatment

Key Takeaways Explain This Topic AI

Oregon drinking water sources range from low-turbidity, low-alkalinity Cascade snowmelt rivers to mineral-rich alluvial aquifers and organic-heavy coastal streams.

OHA conducts sanitary surveys at least every five years at a frequency it sets, covering eight elements; surface water systems answer significant deficiencies in writing within 45 days, and groundwater systems consult within 30 days and correct within 120 days.

Subsurface intakes like Ranney collector wells provide natural riverbank filtration that buffers turbidity spikes and eliminates fish entrainment.

Avoid pre-chlorinating raw water during cyanobacterial blooms: oxidants can lyse cells, releasing dissolved cyanotoxins that filtration cannot remove, and chlorine reacts with bloom organics to form DBPs.

Last updated: October 2026

3.1 Raw Water Sources, Intake Structures & Pretreatment

Note

Potable water treatment begins long before chemical coagulants are injected into the rapid mix chamber. Understanding source water hydrology, watershed geology, intake hydraulics, and physical-chemical pretreatment is essential for maintaining process stability, complying with Oregon Health Authority (OHA) regulations, and protecting downstream unit operations.

Oregon Raw Water Resources & Regional Hydrology

Oregon features four distinct hydrological provinces, each presenting unique water quality characteristics and operational challenges for drinking water treatment facilities:

1. Cascade Range Snowpack-Fed Basins

Rivers originating in the high Cascades—such as the Clackamas River , North and South Santiam Rivers , and McKenzie River —provide municipal drinking water to over a million Oregonians. These surface waters drain volcanic basalt, andesite, and glacial terrain:

Baseline Water Quality: Exceptionally pure under baseflow conditions, characterized by ultra-low total dissolved solids (TDS < 50 mg/L < 50 \text{ mg/L} < 50 mg/L ), low natural turbidity ( < 1.0 − 3.0 NTU < 1.0-3.0 \text{ NTU} < 1.0 − 3.0 NTU ), cold water temperatures ( 3 − 10 ∘ C 3-10^\circ\text{C} 3 − 1 0 ∘ C ), and very low total alkalinity (often 10 − 20 mg/L as CaCO 3 10-20 \text{ mg/L as } \text{CaCO}_3 10 − 20 mg/L as CaCO 3 ​ ).

Operational Challenges: During autumn rain-on-snow events and spring snowmelt freshets, these streams experience rapid, violent turbidity spikes ( > 200 − 500 NTU > 200-500 \text{ NTU} > 200 − 500 NTU ) composed of colloidal clay, volcanic ash, and glacial flour. Furthermore, their low baseline alkalinity provides virtually no buffering capacity against acidic coagulants like aluminum sulfate.

2. Willamette Valley Alluvial Aquifers

Groundwater systems in the Willamette Valley are situated within unconfined and semi-confined river gravel and sand deposits:

Baseline Water Quality: Moderate hardness ( 60 − 150 mg/L as CaCO 3 60-150 \text{ mg/L as } \text{CaCO}_3 60 − 150 mg/L as CaCO 3 ​ ), stable temperatures ( 11 − 14 ∘ C 11-14^\circ\text{C} 11 − 1 4 ∘ C ), and high clarity.

Operational Challenges: Anoxic geochemical conditions frequently dissolve substantial concentrations of reduced ferrous iron ( Fe 2 + \text{Fe}^{2+} Fe 2 + ) and manganous manganese ( Mn 2 + \text{Mn}^{2+} Mn 2 + ). Shallow unconfined aquifers are also vulnerable to anthropogenic contamination, including agricultural nitrate ( NO 3 − \text{NO}_3^- NO 3 − ​ ) from fertilizer applications and localized volatile organic compounds (VOCs).

3. Coastal Surface Basins

Rivers draining the Oregon Coast Range—such as the Nehalem , Siletz , Yaquina , and Coquille rivers—flow through temperate rainforests with annual precipitation exceeding 80 − 120 inches 80-120 \text{ inches} 80 − 120 inches :

Baseline Water Quality: Naturally acidic to neutral pH ( 6.0 − 7.0 6.0-7.0 6.0 − 7.0 ), low hardness, and moderate turbidity.

Operational Challenges: Abundant decaying forest litter yields exceptionally high concentrations of Natural Organic Matter (NOM) , including humic and fulvic acids. This produces elevated True Color ( > 40 − 80 Pt-Co units > 40-80 \text{ Pt-Co units} > 40 − 80 Pt-Co units ) and high Total Organic Carbon (TOC) levels ( 4.0 − 10.0 mg/L 4.0-10.0 \text{ mg/L} 4.0 − 10.0 mg/L ), creating extreme Disinfection Byproduct (DBP) precursor loading when exposed to free chlorine.

4. High-Desert Groundwater & Volcanic Aquifers

East of the Cascade crest, the Deschutes Basin , Harney Basin , and regional basalt formations govern drinking water supplies:

Baseline Water Quality: Low organic content, excellent microbiological clarity, and stable year-round yields.

Operational Challenges: Deep volcanic contact zones introduce high dissolved silica ( 30 − 60 mg/L as SiO 2 30-60 \text{ mg/L as } \text{SiO}_2 30 − 60 mg/L as SiO 2 ​ ), which can foul membrane systems, as well as localized geothermal signatures including naturally occurring arsenic ( As \text{As} As ), boron , and elevated fluoride ( F − \text{F}^- F − ) that require specialized adsorption or ion exchange processes.

  • Source Water Protection & Sanitary Surveys (OAR 333-061)
  • Drinking water source protection

DEQ and OHA jointly run Oregon's drinking water source protection program. They have delineated source areas and produced source water assessments that inventory potential contaminant sources (septic systems, fuel storage, agriculture, timber harvest, upstream wastewater outfalls, transportation corridors) and rate susceptibility. Local protection plans are voluntary. A groundwater system may also have a wellhead protection program certified by OHA (OAR 333-061-0057). For surface water, the supplier must survey the watershed for natural and human factors affecting quality before siting an intake (OAR 333-061-0050(3)).

Sanitary surveys (OAR 333-061-0076)

OHA conducts a sanitary survey of every community, non-transient non-community and transient non-community system at least every five years , at a frequency it determines. The report covers eight components:

Source: intake structures, well casings and seals, springs, protection from flooding and surface water.

Treatment: chemical feed equipment, separation of treated from untreated water, turbidity monitoring locations, CT, membrane integrity testing, UV alarms.

Distribution system: pressure of at least 20 psi at all service connections at all times, main repair practices, cross connection control, flushing.

Finished water storage: secure, watertight roofs and hatches, screened vents, flap valves or screens on drains and overflows.

Pumps, pump facilities and controls: suction-side pressure protection on booster pumps, standby power, controls.

Monitoring, reporting and data verification: sampling plans, analyzer calibration, monthly reports.

System management and operation: O&M practices, emergency planning, records.

Operator compliance: an operator in Direct Responsible Charge at the required level.

Important

Items such as an unscreened vent, a well seal that is not watertight, pressure below 20 psi, or no DRC operator are listed significant deficiencies . Surface water and GWUDI systems must respond in writing within 45 days with a correction plan and schedule that OHA approves. Groundwater-only systems must consult OHA within 30 days and, within 120 days , either correct the deficiency or be following an OHA-approved corrective plan.

Raw Water Intake Engineering

Intake structures must physically extract water while excluding debris, protecting aquatic organisms, and dampening raw water quality fluctuations. +-----------------------------------------------------------------------------+

  • | RAW WATER INTAKE SPECTRUM |
  • +-----------------------------------+-----------------------------------------+
  • | SURFACE WATER INTAKES | SUBSURFACE INTAKES |
  • | - Submerged Intake Cribs | - Ranney Collector Wells (Radial) |
  • | - Velocity Caps (< 0.5 ft/s) | - Infiltration Galleries |
  • | - Coarse Bar Racks (2-4 in) | - Natural Riverbank Filtration (RBF) |
  • | - Traveling Water Screens | - Zero Fish Impingement |
  • | - Vulnerable to Ice & Floods | - Attenuates Turbidity & Temp Spikes |
  • +-----------------------------------+-----------------------------------------+
  • Surface Water River Intakes

Submerged Intake Cribs: Concrete or steel structures anchored in deep, stable river channels. Equipped with velocity caps that redirect vertical suction into horizontal inflow planes. Where juvenile salmon and steelhead are present, National Marine Fisheries Service fish screen criteria limit the approach velocity at the screen face to about 0.4 ft/s for actively cleaned screens and 0.2 ft/s for passive screens, to prevent impingement and entrainment.

Bar Racks (Trash Racks): Heavy, parallel steel bars spaced 2 to 4 inches 2 \text{ to } 4 \text{ inches} 2 to 4 inches apart at the intake mouth. Bar racks physically exclude tree limbs, root wads, river stones, and large debris transported during flood stages.

Traveling Water Screens: Positioned inside the raw intake pump well downstream of bar racks. These comprise continuous loops of motorized wire cloth trays (mesh openings typically 1 / 4 to 3 / 8 inch 1/4 \text{ to } 3/8 \text{ inch} 1/4 to 3/8 inch ). When debris accumulates and causes a predetermined differential water level across the screen ( 2 − 4 inches 2-4 \text{ inches} 2 − 4 inches of head differential), the screen automatically rotates upward. High-pressure spray headers ( 60 − 80 psi 60-80 \text{ psi} 60 − 80 psi ) blast trapped leaves, algae, and river trash into a collection sluice trough.

Subsurface Intakes: Ranney Collectors & Infiltration Galleries

To avoid surface debris, fish entrainment, and volatile water quality, many Pacific Northwest utilities utilize subsurface extraction:

Ranney Collector Wells (Radial Collector Wells): A central reinforced concrete caisson (typically 10 − 16 ft 10-16 \text{ ft} 10 − 16 ft internal diameter) is sunk into permeable alluvial gravels adjacent to or beneath a riverbed. Perforated stainless steel lateral well screens are jacked horizontally outward through wall ports deep into the alluvial aquifer formation.

Infiltration Galleries: Horizontal perforated pipes embedded in engineered, graded gravel trenches excavated beneath the active riverbed.

Operational Advantages: Subsurface systems exploit Riverbank Filtration (RBF) . The riverbed sediment bed serves as a natural roughing filter that eliminates fish screens, removes macro-invertebrates and Giardia cysts, buffers sudden temperature swings, and dampens river turbidity surges from > 300 NTU > 300 \text{ NTU} > 300 NTU down to < 5 NTU < 5 \text{ NTU} < 5 NTU .

  • Aquatic Biosecurity & Cold-Weather Challenges
  • Invasive Mussel Control

Invasive dreissenid mussels— Quagga mussels ( Dreissena bugensis ) and Zebra mussels ( Dreissena polymorpha )—pose an existential threat to water infrastructure throughout the western United States. Their microscopic free-swimming larvae ( veligers ) enter intake pipelines, settle onto interior surfaces, and form dense, multi-layered colonies that severely restrict pipe diameters, increase friction head loss, and foul raw water pumps. Water with dissolved calcium concentrations > 15 mg/L > 15 \text{ mg/L} > 15 mg/L and pH between 7.4 and 8.5 7.4 \text{ and } 8.5 7.4 and 8.5 presents severe risk. Protective strategies include continuous mechanical pigging, intake line thermal shocking, copper ion generator dosing, and intake tunnel chlorination (subject to strict environmental NPDES discharge limits).

Frazil Ice & Anchor Ice Management

During clear, subfreezing winter nights in the Pacific Northwest, surface water in turbulent, open rivers can become supercooled to temperatures between − 0.01 ∘ C -0.01^\circ\text{C} − 0.0 1 ∘ C and − 0.05 ∘ C -0.05^\circ\text{C} − 0.0 5 ∘ C without freezing solid:

Frazil Ice: Supercooling triggers the rapid formation of microscopic, disc-shaped ice crystals suspended in the turbulent water column. When this supercooled water enters an intake structure, the frazil crystals adhere instantly to submerged metal surfaces, trash racks, and screen wire. Within minutes, the crystals agglomerate, bridging openings and blinding the intake completely, leading to pump cavitation and total loss of plant inflow.

Anchor Ice: Submerged ice that freezes directly onto riverbed cobbles and submerged cribbing, detaching during daylight and floating downstream to clog screens.

Operational Countermeasures: Operators combat frazil ice by:

Installing pneumatic air-burst systems that release massive, instantaneous blasts of compressed air to shatter ice bridging on racks.

Applying low-voltage electrical resistance heating or warm water/steam circulation to keep metal rack surfaces slightly above 0.0 ∘ C 0.0^\circ\text{C} 0. 0 ∘ C .

Throttling intake suction velocities below the critical shear threshold that promotes crystal adhesion.

Pretreatment Unit Operations

Pretreatment unit operations prepare raw water physically and chemically for subsequent coagulation and filtration, removing interfering substances and reducing chemical coagulant demand.

1. Aeration Systems

Aeration introduces ambient atmospheric oxygen into water and strips out undesirable dissolved volatile gases based on Henry's Law .

Aerator Configuration Mechanical Description Primary Operational Application

Cascade Aerator Water flows over a series of concrete steps or weirs Inexpensive CO 2 \text{CO}_2 CO 2 ​ stripping and mild dissolved oxygen enhancement

Multiple-Tray Aerator Water trickles through perforated trays filled with coke, slag, or ceramic balls Gas stripping ( H 2 S \text{H}_2\text{S} H 2 ​ S ) and oxidation of moderate iron concentrations

Forced-Draft Packed Tower Counter-current vertical tower with high-surface-area plastic packing and bottom blower High-efficiency stripping of volatile organics (VOCs), radon ( 222 Rn ^{222}\text{Rn} 222 Rn ), and H 2 S \text{H}_2\text{S} H 2 ​ S

Diffused Bubble Aerator Submerged perforated pipes or porous diffusers inject compressed air into a basin Deep basin aeration, flexible retrofitting, dissolved oxygen enrichment

Gas Stripping: Stripping dissolved hydrogen sulfide ( H 2 S \text{H}_2\text{S} H 2 ​ S ) removes the offensive "rotten egg" odor and eliminates a potent consumer of chlorine. Stripping dissolved carbon dioxide ( CO 2 \text{CO}_2 CO 2 ​ ) raises raw water pH naturally, eliminating corrosive carbonic acid without requiring supplemental caustic chemical feeds. Aeration also strips combustible methane ( CH 4 \text{CH}_4 CH 4 ​ ) and radioactive radon ( 222 Rn ^{222}\text{Rn} 222 Rn ).

Dissolved Metal Oxidation: Aeration introduces atmospheric oxygen to convert soluble reduced metals into insoluble precipitates: 4 Fe 2 + + O 2 + 10 H 2 O → 4 Fe(OH) 3 ↓ + 8 H + 4\text{Fe}^{2+} + \text{O}_2 + 10\text{H}_2\text{O} \rightarrow 4\text{Fe(OH)}_3\downarrow + 8\text{H}^+ 4 Fe 2 + + O 2 ​ + 10 H 2 ​ O → 4 Fe(OH) 3 ​ ↓ + 8 H + Stoichiometrically, 0.14 mg 0.14 \text{ mg} 0.14 mg of O 2 \text{O}_2 O 2 ​ is required to oxidize 1.0 mg 1.0 \text{ mg} 1.0 mg of Fe 2 + \text{Fe}^{2+} Fe 2 + , while 0.29 mg 0.29 \text{ mg} 0.29 mg of O 2 \text{O}_2 O 2 ​ is required to oxidize 1.0 mg 1.0 \text{ mg} 1.0 mg of Mn 2 + \text{Mn}^{2+} Mn 2 + . While iron oxidizes rapidly at pH > 7.0 \text{pH} > 7.0 pH > 7.0 , dissolved manganese oxidation kinetics with oxygen alone are extremely sluggish below pH 9.5 \text{pH } 9.5 pH 9.5 , necessitating chemical pre-oxidants.

2. Chemical Pre-Oxidation

Potassium Permanganate ( KMnO 4 \text{KMnO}_4 KMnO 4 ​ ): A powerful chemical oxidant widely dosed at the raw intake to rapidly oxidize dissolved manganese and iron: 3 Mn 2 + + 2 KMnO 4 + 2 H 2 O → 5 MnO 2 ↓ + 2 K + + 4 H + 3\text{Mn}^{2+} + 2\text{KMnO}_4 + 2\text{H}_2\text{O} \rightarrow 5\text{MnO}_2\downarrow + 2\text{K}^+ + 4\text{H}^+ 3 Mn 2 + + 2 KMnO 4 ​ + 2 H 2 ​ O → 5 MnO 2 ​ ↓ + 2 K + + 4 H + Reaction stoichiometry requires 1.92 mg/L 1.92 \text{ mg/L} 1.92 mg/L of KMnO 4 \text{KMnO}_4 KMnO 4 ​ per 1.0 mg/L 1.0 \text{ mg/L} 1.0 mg/L of Mn 2 + \text{Mn}^{2+} Mn 2 + . Precise jar-test calibration is critical: under-dosing leaves dissolved manganese in the water, which oxidizes in distribution to produce black staining; over-dosing passes unreacted permanganate into finished water, producing a distinct pink or purple discoloration at consumer taps.

Chlorine Dioxide ( ClO 2 \text{ClO}_2 ClO 2 ​ ): A dissolved gas generated on-site. It rapidly oxidizes iron, manganese, and taste-and-odor compounds without reacting with ammonia or generating trihalomethanes. Dosage is constrained by the strict Maximum Contaminant Level (MCL) of 1.0 mg/L 1.0 \text{ mg/L} 1.0 mg/L for the chlorite byproduct.

Ozone ( O 3 \text{O}_3 O 3 ​ ): An aggressive oxidant that destroys algal odor compounds ( geosmin and 2-MIB ). However, ozone will oxidize dissolved bromide ( Br − \text{Br}^- Br − ) into carcinogenic bromate ( BrO 3 − \text{BrO}_3^- BrO 3 − ​ ), which has an EPA/OHA MCL of 0.010 mg/L 0.010 \text{ mg/L} 0.010 mg/L .

Caution

Avoid Raw Water Pre-Chlorination During Blooms: EPA cyanotoxin guidance and standard practice advise against dosing free chlorine or other strong oxidants ahead of coagulation when raw water carries an active cyanobacterial bloom, and pre-chlorinating water high in natural organic matter drives DBP formation. Free chlorine lyses (ruptures) intact cyanobacterial cells, discharging dissolved intracellular cyanotoxins ( microcystins, anatoxin-a, cylindrospermopsin ) that cannot be removed by subsequent conventional clarification. Simultaneously, chlorine reacts with raw humic/fulvic acids to generate dangerous concentrations of regulated Disinfection Byproducts (TTHMs and HAA5) .

3. Presedimentation Basins & Grit Removal

Presedimentation basins and vortex grit separators are installed ahead of the flash mix basin to settle out heavy, settleable mineral solids—such as volcanic pumice, coarse sand, and heavy silts—during Oregon's high-turbidity winter freshets. These basins protect low-lift pump impellers from abrasive wear, prevent scouring of chemical feed lines, and keep rapid-mix tanks from accumulating dead grit deposits.

Raw Water Quality Parameters Matrix

Parameter Analytical Unit Typical PNW Range Operational & Regulatory Significance

Turbidity Nephelometric Turbidity Units (NTU) 0.5 − 500 + NTU 0.5 - 500+ \text{ NTU} 0.5 − 500 + NTU Measures light-scattering particles. Surges during winter storms; governs coagulant dosing.

True Color Platinum-Cobalt Units (Pt-Co) 5 − 80 + Pt-Co 5 - 80+ \text{ Pt-Co} 5 − 80 + Pt-Co Measured after filtration through 0.45 μ m 0.45 \ \mu\text{m} 0.45 μ m membrane. Indicates dissolved humic/fulvic acids and DBP precursor risk.

Apparent Color Platinum-Cobalt Units (Pt-Co) 10 − 250 + Pt-Co 10 - 250+ \text{ Pt-Co} 10 − 250 + Pt-Co Color of unfiltered sample; includes both suspended particulate turbidity and dissolved color.

pH Standard pH Units 6.2 − 8.2 6.2 - 8.2 6.2 − 8.2 Dictates coagulant hydrolysis species, chemical solubility, and oxidant kinetics.

Alkalinity mg/L as CaCO 3 \text{mg/L as } \text{CaCO}_3 mg/L as CaCO 3 ​ 10 − 150 mg/L 10 - 150 \text{ mg/L} 10 − 150 mg/L Acid-neutralizing capacity. Low in Cascade rivers ( < 20 mg/L < 20 \text{ mg/L} < 20 mg/L ); required for alum flocculation.

Total Organic Carbon (TOC) mg/L \text{mg/L} mg/L 1.0 − 10.0 mg/L 1.0 - 10.0 \text{ mg/L} 1.0 − 10.0 mg/L Direct measure of natural organic matter; governs Disinfectants/DBP Rule Stage 1 Enhanced Coagulation requirements.

Water Temperature Degrees Celsius ( ∘ C ^\circ\text{C} ∘ C ) 2 − 18 ∘ C 2 - 18^\circ\text{C} 2 − 1 8 ∘ C Governs water viscosity, chemical reaction kinetics, and backwash bed expansion.

Reservoir Stratification, Turnover and Algae Control

Many Oregon systems draw from storage reservoirs or lakes, where water quality changes with the seasons:

Summer stratification : the sun warms the surface layer ( epilimnion ), which floats on colder, denser bottom water ( hypolimnion ), separated by the thermocline . Bottom water is cut off from the air, and decaying organic matter uses up its oxygen.

Anoxic bottom water dissolves iron and manganese from sediments and builds up hydrogen sulfide, ammonia and color.

Turnover : in fall, the surface cools until it matches the bottom temperature, and wind mixes the whole lake. Poor-quality bottom water suddenly reaches the intake, bringing manganese spikes, odors, color and higher oxidant and coagulant demand. A smaller spring turnover can follow ice-out.

Operator responses : use multi-level intakes to draw from the best depth, increase raw water monitoring before and during turnover, adjust oxidant and coagulant doses with jar tests, and in some reservoirs run hypolimnetic aeration or destratification mixers.

Algae and cyanobacteria : watch for blooms in warm, calm, nutrient-rich water. Algaecides such as copper products must be used according to the label. In Oregon, pesticide applications in, over or within three feet of water fall under DEQ's 2300-A Pesticide General Permit . Treating an established cyanobacterial bloom can lyse cells and release toxins, so treat early or switch sources when possible.