Study guide

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control

Oregon Water and Wastewater Operator Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification

1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees

2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal

2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates

3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins

3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)

4 Chapter 4: Source Water, Intakes and Wells

4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection

5 Chapter 5: Coagulation, Clarification and Filtration

5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration

6 Chapter 6: Drinking Water Disinfection

6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control

7 Chapter 7: Specialty Water Treatment and Residuals

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate

8 Chapter 8: Distribution System Infrastructure

8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating

9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality

9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs

10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons

10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons

11 Chapter 11: Biological Wastewater Treatment

11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems

12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control

13 Chapter 13: Solids Handling and Biosolids

13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503

14 Chapter 14: Wastewater Collection Systems and Pumping

14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety

15 Chapter 15: Collection System Rehabilitation and Overflow Control

15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control

16 Chapter 16: Laboratory Procedures and Water Quality Testing

16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting

17 Chapter 17: Equipment, Electrical Systems and Maintenance

17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA

18 Chapter 18: Applied Water and Wastewater Mathematics

18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower

19 Chapter 19: Utility Safety

19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules

20 Chapter 20: Emergency Preparedness, Security and Utility Management

20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management

7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control

Key Takeaways Explain This Topic AI

Iron's secondary MCL is 0.3 mg/L and manganese's is 0.05 mg/L; both are removed by oxidizing them to solids and filtering.

Per mg/L of metal, chlorine needs about 0.62 mg/L for iron and 1.29 for manganese, potassium permanganate needs about 0.94 and 1.92, and oxygen 0.14 and 0.29.

Manganese greensand and other oxide-coated media adsorb and oxidize manganese catalytically and need continuous or intermittent regeneration with permanganate or chlorine.

Hardness is calcium plus magnesium as CaCO3; lime-soda softening removes carbonate hardness with lime and noncarbonate hardness with soda ash, and ion exchange swaps hardness for sodium.

Geosmin and 2-MIB cause earthy-musty odors at nanogram-per-liter levels and are removed mainly with powdered or granular activated carbon or ozone.

Last updated: October 2026

Iron and Manganese

Groundwater from Willamette Valley alluvium and many basalt aquifers often carries dissolved ferrous iron (Fe2+) and manganous manganese (Mn2+) because the water has little oxygen. Neither is a major health risk at typical levels. But at the secondary MCLs of 0.3 mg/L (iron) and 0.05 mg/L (manganese) , they stain fixtures and laundry, cause red or black water, and feed iron and manganese bacteria. Manganese also has an EPA health advisory, so it is getting more attention.

Oxidant demand

Removal starts by oxidizing the dissolved metals to insoluble particles: ferric hydroxide (orange-brown) and manganese dioxide (black).

  • Oxidant mg/L per mg/L Fe2+ mg/L per mg/L Mn2+ Notes
  • Oxygen (aeration) 0.14 0.29 Fast for iron above pH 7; very slow for manganese below about pH 9.5
  • Chlorine 0.62 1.29 Good for iron; manganese is slow unless pH is high or catalytic media are used
  • Potassium permanganate 0.94 1.92 Fast for both; overdose turns water pink
  • Chlorine dioxide 1.2 2.5 Fast; watch chlorite formation

Worked example. A well has 1.4 mg/L iron and 0.60 mg/L manganese. The theoretical permanganate demand is:

  • Iron: 1.4 × 0.94 = 1.32 mg/L
  • Manganese: 0.60 × 1.92 = 1.15 mg/L
  • Total: about 2.5 mg/L , before any extra demand from organics or sulfide

Real doses are confirmed by jar testing. An overdose sends pink or purple water to customers, and an underdose lets manganese pass and blacken later.

Removal processes

Oxidation and filtration. Aerate or dose an oxidant, allow detention time, then filter through sand, anthracite or dual media. High iron loads may need settling first.

Catalytic media (greensand and similar). Media coated with manganese dioxide adsorb dissolved manganese and oxidize it on the grain surface. Continuous regeneration (CR) feeds a small permanganate or chlorine dose ahead of the filter. Intermittent regeneration (IR) soaks the bed periodically. Oxide-coated media earn 10 points as pressure or greensand filtration in OHA's Table 51.

Sequestration. Polyphosphates or silicates hold small amounts of iron and manganese in solution so they do not precipitate in the mains. This works only at low concentrations, roughly 1 mg/L combined or less. The metals are still delivered, and chlorine contact can eventually release them.

Biological filtration. Iron- and manganese-oxidizing bacteria grow on filter media under controlled oxygen and pH, removing the metals with little chemical feed.

Hardness and Softening

Hardness is the sum of calcium and magnesium, expressed as mg/L of CaCO3:

  • Classification mg/L as CaCO3
  • Soft 0-75
  • Moderately hard 75-150
  • Hard 150-300
  • Very hard over 300

Carbonate hardness is the part balanced by alkalinity. Noncarbonate hardness is the remainder, balanced by sulfate or chloride.

Lime-soda ash softening : lime (Ca(OH)2) raises pH to about 10.3 to precipitate calcium carbonate, or above 11 to precipitate magnesium hydroxide, removing carbonate hardness. Soda ash (Na2CO3) removes noncarbonate hardness. The water is then recarbonated with CO2 to lower pH and stabilize it before filtration. The process produces large volumes of lime sludge and scores 20 points in Table 51.

Ion exchange (cation exchange) : resin swaps calcium and magnesium for sodium. It is regenerated with brine (sodium chloride) and produces brine waste. Softened water gains sodium, which matters for low-sodium diets, and is often blended back to a moderate hardness.

Most western Oregon surface supplies are soft. Softening comes up mainly with some eastern Oregon groundwater and in industrial or point-of-entry settings.

Taste and Odor (T&O)

Odor Typical cause Control

Earthy or musty Geosmin and 2-MIB from cyanobacteria and actinomycetes; detectable near 10 ng/L Powdered activated carbon (PAC), GAC, ozone; manage the source (intake depth, nutrient control)

Rotten egg Hydrogen sulfide in groundwater or stagnant mains Aeration, chlorine or permanganate oxidation, flushing

  • Fishy, grassy or septic Algae blooms and decay Oxidation, PAC, reservoir management
  • Chlorinous or "swimming pool" Dichloramine or excessive free chlorine Adjust the Cl2:NH3-N ratio and dose
  • Metallic Iron, manganese, copper corrosion Remove metals; corrosion control

PAC is fed as a slurry, typically 5 to 25 mg/L or more. It needs contact time before coagulation and should not be dosed together with chlorine or permanganate, because the carbon consumes the oxidant. GAC filter-adsorbers or post-filter contactors give continuous removal until they are exhausted and need regeneration. Operators confirm T&O with the threshold odor number (TON) test and customer complaint tracking. Copper sulfate algaecide dosed in a reservoir can control the bloom that causes T&O. However, killing a cyanobacterial bloom can release toxins, as discussed in the cyanotoxin section.