Study guide
7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
Oregon Water and Wastewater Operator Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oregon Operator Programs and DEQ Wastewater Certification
1.1 Dual-Agency Structure: DEQ Wastewater and OHA Drinking Water Programs 1.2 DEQ Wastewater System Classification and Supervision Rules 1.3 DEQ Certificates: Qualifications, OIT, Provisional Path, Exams and Fees
2 Chapter 2: OHA Drinking Water Certification and Certificate Renewal
2.1 OHA System Classification, Direct Responsible Charge and the Filtration Endorsement 2.2 OHA Certificates: Experience Tables, OIT, Exams, Fees and Small Water System Certification 2.3 Renewal, CEUs, Reinstatement, Reciprocity and Discipline for DEQ and OHA Certificates
3 Chapter 3: Federal Rules, Oregon Water Quality Standards and Cyanotoxins
3.1 Clean Water Act, Safe Drinking Water Act & NPDES Permitting 3.2 Willamette Basin TMDL and Oregon Water Quality Standards 3.3 Harmful Algal Blooms (HABs) & Oregon Cyanotoxin Rules (OAR 333-061-0510)
4 Chapter 4: Source Water, Intakes and Wells
4.1 Raw Water Sources, Intake Structures & Pretreatment 4.2 Groundwater Sources and Wells: Hydraulics, Construction and Protection
5 Chapter 5: Coagulation, Clarification and Filtration
5.1 Coagulation, Flocculation & Jar Testing Dynamics 5.2 Sedimentation, Clarification & Media Filtration Systems 5.3 Slow Sand, Diatomaceous Earth, Cartridge and Membrane Filtration
6 Chapter 6: Drinking Water Disinfection
6.1 Disinfection Chemistry, Chlorination Dynamics & CT Calculations 6.2 UV, Ozone, Chlorine Dioxide, Chloramines and Disinfection Byproduct Control
7 Chapter 7: Specialty Water Treatment and Residuals
7.1 Iron and Manganese Removal, Softening, and Taste and Odor Control 7.2 Corrosion Control, Lead and Copper, and Fluoridation 7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
8 Chapter 8: Distribution System Infrastructure
8.1 Distribution System Hydraulics, Piping Materials & Storage Facilities 8.2 Valves, Fire Hydrants & Water Main Installation / Disinfection 8.3 Service Connections, Meters, Water Loss Control and Utility Locating
9 Chapter 9: Distribution Operations, Cross-Connection Control and Water Quality
9.1 Storage Tank and Booster Pump Station Operation, Inspection and Disinfection 9.2 Cross-Connection Control & Backflow Prevention Assemblies (OAR 333-061-0070) 9.3 Water Quality in Distribution: Water Age, Nitrification & Flushing Programs
10 Chapter 10: Wastewater Preliminary and Primary Treatment and Lagoons
10.1 Preliminary Treatment: Screening, Grit Removal & Flow Measurement 10.2 Primary Clarification & Sedimentation Hydraulics 10.3 Stabilization Ponds and Aerated Lagoons
11 Chapter 11: Biological Wastewater Treatment
11.1 Secondary Treatment: Activated Sludge Process Control & Variations 11.2 Fixed-Film Treatment: Trickling Filters, RBCs, MBBR and IFAS 11.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
12 Chapter 12: Tertiary Treatment, Disinfection, Recycled Water and Small Systems
12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes 12.2 Wastewater Disinfection and Dechlorination 12.3 Small Wastewater Systems, Septage Handling and Odor Control
13 Chapter 13: Solids Handling and Biosolids
13.1 Sludge Thickening, Conditioning & Dewatering Technologies 13.2 Anaerobic and Aerobic Digestion Operations & Control 13.3 Biosolids Quality, Land Application Rules & OAR 340-050 / 40 CFR 503
14 Chapter 14: Wastewater Collection Systems and Pumping
14.1 Gravity Sewer Design, Manholes & Inflow/Infiltration (I/I) Management 14.2 Lift Station Design, Wet Wells & Submersible / Centrifugal Pumps 14.3 Collection System Maintenance, Pipeline Inspection (CCTV) & Trench Safety
15 Chapter 15: Collection System Rehabilitation and Overflow Control
15.1 Sewer Rehabilitation, Trenchless Renewal and New-Pipe Acceptance Testing 15.2 Overflow Response, Bypass Pumping, CMOM Programs and Sewer Sulfide Control
16 Chapter 16: Laboratory Procedures and Water Quality Testing
16.1 Drinking Water Microbiological Testing: Coliform, E. coli & RTCR 16.2 Wastewater Lab Analysis: BOD5, TSS, COD & Volatile Solids 16.3 Wastewater Lab: Nutrients, Alkalinity, Bacteria, Toxicity Testing and Lab Accreditation 16.4 Process Monitoring: pH, Turbidity, Dissolved Oxygen & Chlorine Residuals 16.5 Sampling Protocols, Quality Assurance / Chain of Custody & Reporting
17 Chapter 17: Equipment, Electrical Systems and Maintenance
17.1 Pumps, Blowers and Mechanical Maintenance Programs 17.2 Electrical Systems, Motors, Generators, Instrumentation and SCADA
18 Chapter 18: Applied Water and Wastewater Mathematics
18.1 Dimensional Analysis, Flow Conversions & Detention Time 18.2 Chemical Feed, Dosage Calculations & the Pounds Formula 18.3 Treatment Plant Hydraulics, Loading Rates (SOR, WOR) & Pumping Horsepower
19 Chapter 19: Utility Safety
19.1 OSHA Standards, Confined Space Entry & Hazardous Chemical Safety 19.2 Field Safety: Electrical Hazards, Fall Protection, Work Zones, PPE and Oregon OSHA Rules
20 Chapter 20: Emergency Preparedness, Security and Utility Management
20.1 Cascadia Subduction Zone (CSZ) Seismic Preparedness & Infrastructure Hardening 20.2 Wildfire Impacts on Watersheds, Post-Fire Water Quality & Emergency Operations 20.3 Security, Cybersecurity, Emergency Response Planning and Utility Management
7.3 Water Treatment Residuals: Sludge, Backwash Water and Membrane Concentrate
Key Takeaways Explain This Topic AI
Residuals include coagulant sludge, spent filter backwash, membrane backwash and concentrate, lime softening sludge, ion-exchange brine, and spent activated carbon.
Alum sludge production can be estimated as 8.34 × flow (MGD) × (0.44 × alum dose + raw suspended solids + other additives) in lb/day of dry solids.
Recycled filter backwash must return through the plant's full treatment train, ahead of the primary coagulant, under the Filter Backwash Recycling Rule.
Spent backwash discharged to surface water needs DEQ coverage, such as the 200-J NPDES general permit for filter backwash.
Residuals sent to a landfill must pass the paint filter liquids test, and discharges to a sanitary sewer need the receiving utility's approval.
Last updated: October 2026
Types of Residuals
Residual Source Typical character
Coagulant (alum or ferric) sludge Sedimentation basins, DAF float Gelatinous; about 0.5-2 percent solids before thickening; hard to dewater
Spent filter backwash water (SFBW) Media filter backwash and filter-to-waste Large volume, low solids; contains concentrated particles and pathogens
Membrane residuals MF/UF backwash and CIP wastes; NF/RO concentrate Concentrate carries dissolved salts at several times feed levels; CIP waste may be acidic or caustic
- Lime softening sludge Softening clarifiers Dense calcium carbonate; dewaters well
- Ion-exchange brine Regeneration High chloride and hardness; disposal is often the hardest part of IX
- Spent PAC and GAC Adsorption PAC leaves with the sludge; GAC is regenerated or replaced
OHA's Table 51 even awards classification points for residuals handling. Examples are 5 points each for discharge to lagoons, land application or mechanical dewatering, and 10 for discharge to a raw water source.
Estimating Solids Production
A common estimate for alum coagulation is: Dry solids (lb/day) = 8.34 × Q MGD × ( 0.44 × Alum dose + SS removed + Other additives ) \text{Dry solids (lb/day)} = 8.34 \times Q_{\text{MGD}} \times \left(0.44 \times \text{Alum dose} + \text{SS removed} + \text{Other additives}\right) Dry solids (lb/day) = 8.34 × Q MGD × ( 0.44 × Alum dose + SS removed + Other additives )
Doses are in mg/L. Raw-water suspended solids are often approximated as 1 to 2 times the raw turbidity in NTU.
Worked example. A 4.0 MGD plant doses 25 mg/L alum and adds 3 mg/L PAC. Raw suspended solids average 12 mg/L.
- 0.44 × 25 = 11 mg/L of alum floc
- Total = 11 + 12 + 3 = 26 mg/L of solids
- Dry solids = 8.34 × 4.0 × 26 = 867 lb/day
At 1 percent solids, that is about 867 ÷ (8.34 × 0.01) ≈ 10,400 gallons per day of sludge. Thickening to 4 percent cuts the volume by about 75 percent.
Backwash Water Management
Equalization : backwash water arrives in short, large surges, so it goes to a washwater recovery basin or lagoon where solids settle and flow can be metered back slowly.
Recycling : under the federal Filter Backwash Recycling Rule , conventional and direct filtration plants that recycle SFBW, thickener supernatant or dewatering liquids must return them through all treatment processes, at or before the point of primary coagulant addition . Recycle flow must be limited so it does not overload the plant, and the practice must be documented and reported.
Discharge to surface water : sending backwash or settled supernatant to a stream is a point-source discharge needing DEQ coverage. DEQ's 200-J NPDES general permit covers filter backwash; other cases need an individual permit. Chlorine residual and solids must meet permit limits, which often means dechlorination and settling.
Discharge to sanitary sewer : allowed only with the receiving utility's approval and pretreatment conditions. Large alum slugs can upset a small wastewater plant.
Thickening and Dewatering
Gravity thickeners concentrate coagulant sludge, sometimes with polymer.
Lagoons settle solids over months. They are periodically decanted, allowed to dry, and the solids removed. Freeze-thaw cycles in colder parts of Oregon help dewater alum sludge.
Sand drying beds work for small plants in dry summer climates.
Mechanical dewatering (belt presses, centrifuges, screw presses, plate-and-frame presses) produces cake from about 15 to over 35 percent solids, depending on the sludge and equipment.
Disposal Routes
Landfill : the cake must pass the paint filter liquids test , meaning no free liquid drains through a standard paint filter in 5 minutes.
Land application : alum and ferric residuals can be land-applied with approval. They bind phosphorus, so agronomic suitability matters.
Beneficial use : lime residuals for agricultural liming; alum residuals for soil amendment or phosphorus control.
Concentrate disposal (RO and NF) : sewer discharge, surface discharge under permit, deep-well injection where allowed, or evaporation ponds. Concentrate often decides whether RO is practical at all.
Operating Tips
Record sludge volumes, solids percentages and polymer use so you can spot changes in raw water or coagulant performance.
Do not let recycle streams carry high turbidity or pathogens back to the head of the plant during upsets. Divert or hold them.
Treat residual handling areas as part of plant security and spill planning. Lagoon berms, decant structures and chemical cleaning wastes all need inspection.
Worked Example: Thickening Volume Reduction
Thickening removes water, not solids, so the dry solids mass stays the same while the volume shrinks.
Example. A plant withdraws 50,000 gallons of alum sludge at 1.0 percent solids from its basins and gravity-thickens it to 4.0 percent.
- Dry solids = 50,000 gal × 8.34 lb/gal × 0.010 ≈ 4,170 lb
- Thickened volume = 50,000 gal × (1.0 ÷ 4.0) = 12,500 gallons
Quadrupling the solids concentration cuts the volume to one quarter. That shrinks the hauling, lagoon space or dewatering capacity the plant needs. The 37,500 gallons of separated water become supernatant, which goes back to the head of the plant under the recycle rules or out under a discharge permit.
Residuals Lagoon Operation
Many small and medium Oregon plants send coagulant sludge and backwash solids to lined lagoons or drying beds:
Fill and decant : route flow to one cell while another settles. Decant clear supernatant from the surface, and do not draw down so far that settled solids resuspend.
Rest and dry : take a full cell out of service so solids can drain and dry before removal. In colder parts of the state, freeze-thaw cycles break up gelatinous alum sludge so it drains far better after thawing.
Remove and haul : track solids depth with a sludge judge. Plan removal before solids reduce settling volume and carry over into the decant.
Records : log volumes sent to each cell, decant volumes and quality, and quantities hauled, with destinations, for permit and sanitary survey review.