Study guide
12.2 Diatomaceous Earth Filtration (Subclass 3)
Pennsylvania Water and Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Pennsylvania Regulatory Framework & Operator Administration
1.1 Act 11 of 2002 & 25 Pa. Code Chapter 302 Licensing 1.2 Operator Duties, Process Control Decisions & OIRC 1.3 License Renewal, Continuing Education & Facility Security
2 Chapter 2: Essential Water & Wastewater Mathematics
2.1 Volumes, Flow Rates & Detention Time Calculations 2.2 Chemical Feed, Dosage & Dilution Calculations 2.3 Loading Rates & Pumping Hydraulics Calculations
3 Chapter 3: Facility Hydraulics, Mechanical Equipment & Safety
3.1 Centrifugal & Positive Displacement Pumps 3.2 Valves, Piping & Flow Measurement Instrumentation 3.3 Workplace Safety, Confined Spaces & HazCom
4 Chapter 4: Drinking Water Treatment: Clarification & Solids Removal
4.1 Source Water & Rapid Mix Coagulation 4.2 Flocculation & Sedimentation Processes 4.3 Filtration Technologies & Backwashing Protocols
5 Chapter 5: Drinking Water Treatment: Disinfection & Chemical Processes
5.1 Chlorine Disinfection & CT Compliance 5.2 Alternative Disinfection & DBP Control 5.3 Water Softening, Iron/Manganese & Corrosion Control
6 Chapter 6: Drinking Water Distribution & Small Water Systems
6.1 Distribution Infrastructure & Storage Tanks 6.2 Water Quality Maintenance & Cross-Connection Control 6.3 Small Groundwater Systems (Classes Dc & Dn)
7 Chapter 7: Wastewater Treatment: Preliminary & Primary Treatment
7.1 Influent Characterization & Preliminary Screening 7.2 Grit Removal Systems & Velocity Control 7.3 Primary Clarification & Solids Separation
8 Chapter 8: Wastewater Treatment: Secondary Biological Processes
8.1 Activated Sludge Principles & Configurations 8.2 Activated Sludge Troubleshooting & Secondary Clarifiers 8.3 Fixed-Film Technologies & Treatment Ponds
9 Chapter 9: Nutrient Removal, Chesapeake Bay Compliance & Biosolids
9.1 Biological Nitrogen Removal (Nitrification/Denitrification) 9.2 Phosphorus Removal & Chesapeake Bay Compliance 9.3 Sludge Processing, Digestion & Biosolids Management
10 Chapter 10: Wastewater Collection, Laboratory Testing & Regulatory Reporting
10.1 Wastewater Collection Systems & Lift Stations 10.2 Sampling & Laboratory Procedures (QA/QC) 10.3 Regulatory Compliance Reporting (eDMR / DWELR) & Emergency Response
11 Chapter 11: Drinking Water Regulations, Operator Science & Residuals
11.1 Chapter 109, Part 141 Rules & Public Water System Classification 11.2 Water & Wastewater Chemistry Fundamentals 11.3 Microbiology, Pathogens & Waterborne Disease 11.4 Treatment Plant Residuals & Filter Backwash Recycling
12 Chapter 12: Alternative Filtration Technologies (Subclasses 2 through 6)
12.1 Direct Filtration (Subclass 2) 12.2 Diatomaceous Earth Filtration (Subclass 3) 12.3 Slow Sand Filtration (Subclass 4) 12.4 Cartridge & Bag Filtration (Subclass 5) 12.5 Membrane Filtration Systems Operation (Subclass 6)
13 Chapter 13: Chemical Addition & Contaminant Removal (Subclasses 8 through 10)
13.1 Chemical Addition Systems & Feed Equipment (Subclass 8) 13.2 Ion Exchange & Inorganics Removal (Subclass 9) 13.3 Aeration, Air Stripping & Activated Carbon Adsorption (Subclass 10)
14 Chapter 14: Disinfection Technology Subclasses (11 through 14)
14.1 Gaseous Chlorine Feed Systems (Subclass 11) 14.2 Nongaseous Chemical Disinfection Systems (Subclass 12) 14.3 Ultraviolet Disinfection Systems (Subclass 13) 14.4 Ozone Generation & Contacting Systems (Subclass 14)
15 Chapter 15: Plant Support Systems: Electrical, Maintenance & Instrumentation
15.1 Electrical Fundamentals & Motor Control 15.2 Preventive & Corrective Maintenance Programs 15.3 Instrumentation, SCADA & Online Analyzer Calibration
16 Chapter 16: Wastewater Effluent Disinfection, Lagoon Control & Industrial Pretreatment
16.1 Wastewater Effluent Disinfection & Dechlorination 16.2 Lagoon Process Control, Sludge Surveys & Seasonal Discharge 16.3 Industrial Pretreatment Programs
12.2 Diatomaceous Earth Filtration (Subclass 3)
Key Takeaways Explain This Topic AI
DEP defines Subclassification 3 as a process in which a precoat cake of diatomaceous earth is deposited on a support membrane called a septum, with additional body feed added continuously to maintain cake permeability.
DEP specifies a precoat feed of 0.2 pounds per square foot of filter area, or enough to form a cake 1/8 to 1/5 inch thick, and a body feed of 1 to 10 mg/L of media per 1 mg/L of suspended solids fixed by pilot testing.
Pennsylvania's maximum allowable headloss is 30 psi for a pressure filter and 15 inches of mercury for a vacuum filter, and the DEP nominal filtration rate is 1.0 gpm/sf with a recommended maximum of 1.5 gpm/sf.
Flow must never drop below 0.1 gpm/sf or the cake falls off the septum, so filtered water is recycled through the filter when demand is low.
DE filtration must hold filtered turbidity at or below 1.0 NTU in 95 percent of monthly measurements and never above 2.0 NTU, and is credited with 2-log Giardia, Cryptosporidium and virus removal.
Last updated: September 2026
How the Process Works
Diatomaceous earth (DE) filtration, also called precoat filtration, is a physical straining process. Diatomite is the fossilized silica skeleton of diatoms, milled into grades of controlled permeability. The DEP definition of Subclassification 3 is precise: a precoat cake of diatomaceous earth filter media is deposited on a support membrane (the septum ), and while the water is filtered by passing through the cake, additional filter media known as body feed is continuously added to the feed water to maintain the permeability of the filter cake.
The three components:
Component Function Operator control
Septum Rigid porous support, typically wire mesh, porous stone or fabric on plates, tubes or leaves Inspect for holes, warping and calcium scale; a damaged septum passes media and raw water
Precoat Initial cake 1/8 to 1/5 inch thick, applied by recirculation before service Grade selection and complete coverage
Body feed DE metered continuously into the influent Rate ratio to influent solids; this is the primary run-length control
Precoat: Getting the Filter Into Service
Fill the vessel and establish recirculation from the filter back to the precoat tank.
Slurry the precoat DE and feed it into the recirculating stream. DEP's module specifies a precoat feed of 0.2 pounds per square foot of filter area, or enough to form a cake 1/8 to 1/5 inch thick .
Recirculate until the returning water meets finished-water goals. During recirculation the media bridges across the septum openings; once bridging starts, later particles are caught behind the bridges and the cake builds itself.
Switch slowly to service, opening the influent while maintaining flow so the cake is never unloaded.
Start body feed at the same instant service flow begins.
If the operator goes to service before the recirculated water clears, uncoated septum area passes raw water directly into the finished water. This is the most common cause of a DE plant turbidity failure.
Body Feed: The Run-Length Control
The captured solids from raw water are compressible. If they build up alone, the cake seals and the pressure differential climbs almost immediately. Body feed continuously mixes fresh, rigid diatomite into the accumulating solids so that the cake stays porous.
DEP's published range is 1 to 10 mg/L of body feed media per 1 mg/L of suspended solids in the raw water, with pilot testing used to fix the number for a particular source.
Too little body feed produces a pressure differential that rises steeply and early. The run ends in hours.
Too much body feed wastes chemical and fills the available cake volume in the vessel, also shortening the run and increasing waste volume.
A well-tuned plant shows a gradual, nearly linear pressure rise across the full run.
Generally, raising the body feed concentration increases the volume of filtrate produced before terminal headloss is reached, so the body feed cost is traded against precoat media cost and the labor of more frequent cleanings.
The filter is removed from service at terminal headloss. Pennsylvania's maximum allowable headloss is 30 psi for a pressure filter and 15 inches of mercury for a vacuum filter.
Media, Rate Control and Cake Removal
Two media are used. Diatomite is almost pure silica; perlite is derived from glassy volcanic rock. Finer grades capture smaller particles but produce a higher pressure drop. Wet DE has a specific gravity of about 2.3 , while perlite is 32 to 70 percent less dense , and that lower density makes perlite less likely to migrate to the bottom of the septum during a run. Either medium can be bought pre-coated with an aluminum or iron coagulant or a cationic polymer, which studies show improves removal of small particles, turbidity, bacteria and viruses. Slurried media is stored at 12 percent concentration or less , kept continuously mixed, with mixers turning 40 to 60 rpm — fast enough to prevent settling, slow enough not to grind the media down.
Filtration rate is the other lever:
- Rate Value Why it matters
- Vacuum filter operating range 0.5 to 1.0 gpm/sf Normal design band for vacuum units
- Pressure filter operating range Up to 3 gpm/sf Higher driving pressure permits higher rate
- DEP nominal rate 1.0 gpm/sf The rate recommended in the PA DEP Water Supply Manual
- DEP recommended maximum 1.5 gpm/sf Above this, cake life and effluent quality degrade
- Minimum flow 0.1 gpm/sf Below this the cake falls off the septum
Rate changes must be made slowly and smoothly , using an effluent-side rate-of-flow control valve or a variable frequency drive. When system demand falls below the minimum, filtered water is recycled through the filter to hold flow above 0.1 gpm/sf rather than letting the unit idle.
Spent cake is removed by sluicing with high-pressure sprays that must cover the entire septum surface, by flow reversal with clean water, or by pressurizing the vessel with air and suddenly releasing it to create a high-velocity reverse flow. Incomplete removal is a recurring troubleshooting item: leftover media produces lumps and bare spots at the next precoat and an abnormally high initial headloss, and media left in the vessel resuspends and fouls the septum over successive cycles. Up to 90 percent of the media can be recovered , but recovered media may never be used for precoat because pathogens may remain in it; it must be disinfected before reuse as body feed.
The Continuous Flow Rule
The cake is held on the septum only by the differential pressure of flowing water. If flow stops or reverses even briefly, the cake falls off the septum . Recovery requires a complete shutdown, cleanout and fresh precoat, and any water produced during a momentary interruption is suspect. Practical implications:
Filters are brought on and off line slowly using rate-of-flow controllers, never below 0.1 gpm/sf.
Standby power or a controlled shutdown sequence protects against pump trips.
Multiple smaller units are preferred over one large unit so that flow can be shifted without stopping.
Pennsylvania Performance Standards
DE filtration is one of the acceptable technologies under Pennsylvania's Surface Water Filtration Rule, but it is held to a different turbidity number than the coagulation-based processes:
Requirement DE filtration value
Filtered water turbidity 1.0 NTU or less in 95 percent of monthly measurements (conventional and direct filtration are held to 0.3 NTU; slow sand also gets 1.0 NTU)
- Turbidity maximum Never above 2.0 NTU
- Combined filter effluent turbidity monitoring Measured every four hours
- Removal credited to filtration 2-log (99 percent) Giardia, 2-log Cryptosporidium and 2-log virus
Additional inactivation by disinfection At least 1-log (90 percent) Giardia and 3-log (99.9 percent) virus through the plant
- Minimum distribution residual 0.02 mg/L as total chlorine, combined chlorine or chlorine dioxide
- Reporting Turbidity and disinfectant residual reported monthly; violations reported to DEP
Published testing puts measured Giardia removal by a properly operated DE filter between 2-log and 4-log, and DEP's LT2 rules may require additional Cryptosporidium treatment depending on source water occurrence.
Safety: Silica, Dust and Pressure
Media handling is a genuine hazard rather than a footnote. Crystalline silica, present in diatomaceous earth and in lesser amounts in perlite, is a probable carcinogen when inhaled , and the media is abrasive enough to cause irritation or injury on contact. Install dust collectors wherever dry media is loaded into hoppers or tanks, add media to moving water when making slurry to keep dust down, and require goggles, gloves and a respirator for anyone handling media, with an eyewash station nearby . On the equipment side, pressure vessels must carry a pressure relief device , and rupture disks need drain piping sized for a shattered disk and the initial pressure surge.
Where DE Filtration Fits in Pennsylvania
Strength Limitation
Excellent physical removal of Giardia cysts and Cryptosporidium oocysts by straining Almost no removal of dissolved organics, color, taste, odor or disinfection byproduct precursors
Compact footprint and modest capital cost for small systems Requires a consistent, low-turbidity source, typically 10 NTU or less with only occasional spikes, since solids loading directly limits run length
No coagulant chemistry to manage day to day Continuous DE handling creates a respirable crystalline silica hazard requiring dust control and respiratory protection
Simple to understand and troubleshoot Fragile process: any flow interruption forces a full restart
Because DE removes particles but not dissolved constituents, a Pennsylvania system using DE on a source with elevated total organic carbon still has to solve Stage 2 disinfection byproduct compliance separately, usually by moving the disinfectant application point or by changing disinfectant.