Study guide

11.1 Chapter 109, Part 141 Rules & Public Water System Classification

Pennsylvania Water and Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Pennsylvania Regulatory Framework & Operator Administration

1.1 Act 11 of 2002 & 25 Pa. Code Chapter 302 Licensing 1.2 Operator Duties, Process Control Decisions & OIRC 1.3 License Renewal, Continuing Education & Facility Security

2 Chapter 2: Essential Water & Wastewater Mathematics

2.1 Volumes, Flow Rates & Detention Time Calculations 2.2 Chemical Feed, Dosage & Dilution Calculations 2.3 Loading Rates & Pumping Hydraulics Calculations

3 Chapter 3: Facility Hydraulics, Mechanical Equipment & Safety

3.1 Centrifugal & Positive Displacement Pumps 3.2 Valves, Piping & Flow Measurement Instrumentation 3.3 Workplace Safety, Confined Spaces & HazCom

4 Chapter 4: Drinking Water Treatment: Clarification & Solids Removal

4.1 Source Water & Rapid Mix Coagulation 4.2 Flocculation & Sedimentation Processes 4.3 Filtration Technologies & Backwashing Protocols

5 Chapter 5: Drinking Water Treatment: Disinfection & Chemical Processes

5.1 Chlorine Disinfection & CT Compliance 5.2 Alternative Disinfection & DBP Control 5.3 Water Softening, Iron/Manganese & Corrosion Control

6 Chapter 6: Drinking Water Distribution & Small Water Systems

6.1 Distribution Infrastructure & Storage Tanks 6.2 Water Quality Maintenance & Cross-Connection Control 6.3 Small Groundwater Systems (Classes Dc & Dn)

7 Chapter 7: Wastewater Treatment: Preliminary & Primary Treatment

7.1 Influent Characterization & Preliminary Screening 7.2 Grit Removal Systems & Velocity Control 7.3 Primary Clarification & Solids Separation

8 Chapter 8: Wastewater Treatment: Secondary Biological Processes

8.1 Activated Sludge Principles & Configurations 8.2 Activated Sludge Troubleshooting & Secondary Clarifiers 8.3 Fixed-Film Technologies & Treatment Ponds

9 Chapter 9: Nutrient Removal, Chesapeake Bay Compliance & Biosolids

9.1 Biological Nitrogen Removal (Nitrification/Denitrification) 9.2 Phosphorus Removal & Chesapeake Bay Compliance 9.3 Sludge Processing, Digestion & Biosolids Management

10 Chapter 10: Wastewater Collection, Laboratory Testing & Regulatory Reporting

10.1 Wastewater Collection Systems & Lift Stations 10.2 Sampling & Laboratory Procedures (QA/QC) 10.3 Regulatory Compliance Reporting (eDMR / DWELR) & Emergency Response

11 Chapter 11: Drinking Water Regulations, Operator Science & Residuals

11.1 Chapter 109, Part 141 Rules & Public Water System Classification 11.2 Water & Wastewater Chemistry Fundamentals 11.3 Microbiology, Pathogens & Waterborne Disease 11.4 Treatment Plant Residuals & Filter Backwash Recycling

12 Chapter 12: Alternative Filtration Technologies (Subclasses 2 through 6)

12.1 Direct Filtration (Subclass 2) 12.2 Diatomaceous Earth Filtration (Subclass 3) 12.3 Slow Sand Filtration (Subclass 4) 12.4 Cartridge & Bag Filtration (Subclass 5) 12.5 Membrane Filtration Systems Operation (Subclass 6)

13 Chapter 13: Chemical Addition & Contaminant Removal (Subclasses 8 through 10)

13.1 Chemical Addition Systems & Feed Equipment (Subclass 8) 13.2 Ion Exchange & Inorganics Removal (Subclass 9) 13.3 Aeration, Air Stripping & Activated Carbon Adsorption (Subclass 10)

14 Chapter 14: Disinfection Technology Subclasses (11 through 14)

14.1 Gaseous Chlorine Feed Systems (Subclass 11) 14.2 Nongaseous Chemical Disinfection Systems (Subclass 12) 14.3 Ultraviolet Disinfection Systems (Subclass 13) 14.4 Ozone Generation & Contacting Systems (Subclass 14)

15 Chapter 15: Plant Support Systems: Electrical, Maintenance & Instrumentation

15.1 Electrical Fundamentals & Motor Control 15.2 Preventive & Corrective Maintenance Programs 15.3 Instrumentation, SCADA & Online Analyzer Calibration

16 Chapter 16: Wastewater Effluent Disinfection, Lagoon Control & Industrial Pretreatment

16.1 Wastewater Effluent Disinfection & Dechlorination 16.2 Lagoon Process Control, Sludge Surveys & Seasonal Discharge 16.3 Industrial Pretreatment Programs

11.1 Chapter 109, Part 141 Rules & Public Water System Classification

Key Takeaways Explain This Topic AI

A public water system under 25 Pa. Code Chapter 109 serves at least 15 service connections or an average of at least 25 individuals for at least 60 days per year.

Community, nontransient noncommunity and transient noncommunity classifications determine which Chapter 109 monitoring applies; a transient system monitors for microbiological and nitrate contaminants but not for organics with chronic health effects.

A maximum contaminant level is an enforceable concentration, a treatment technique is an enforceable process requirement, and an action level for lead (0.015 mg/L) or copper (1.3 mg/L) triggers corrosion control rather than being an MCL.

Tier 1 public notification must be issued within 24 hours, Tier 2 within 30 days and Tier 3 within one year, and Pennsylvania requires verbal notice to the DEP district office within one hour for acute violations.

Community systems must deliver a Consumer Confidence Report to every customer by July 1 covering the prior calendar year, and all systems report monitoring results to DEP through the Drinking Water Electronic Lab Reporting system.

Last updated: September 2026

Why Classification Comes First

Pennsylvania adopts the federal National Primary Drinking Water Regulations (40 CFR Part 141) by reference and adds state requirements in 25 Pa. Code Chapter 109 . The Part 1 General examination assigns an explicit 13% question category to this material, and every subclass exam repeats "drinking water regulations" in its knowledge statements. Operators fail these questions when they memorize numbers without knowing which system the number applies to .

A public water system (PWS) is a system that provides water for human consumption through pipes or other constructed conveyances to at least 15 service connections or serves an average of at least 25 individuals for at least 60 days per year . Everything else in Chapter 109 flows from the sub-classification:

PWS type Definition Practical example Core monitoring

Community (CWS) Serves year-round residents Borough water authority, mobile home park Full suite: microbiological, inorganic, organic, radiological, disinfection byproducts, lead and copper

Nontransient noncommunity (NTNC) Serves at least 25 of the same people over 6 months per year, not residents Factory, school, office park with its own well Microbiological, nitrate, and contaminants with chronic health effects, including lead and copper

Transient noncommunity (TNC) Serves a changing population Campground, restaurant, highway rest stop Microbiological and nitrate/nitrite only

Consecutive system Buys all of its water from another PWS and resells it Small borough purchasing finished water from a regional authority Distribution-side monitoring: coliform, disinfectant residual, disinfection byproducts

A consecutive system is the reason Class E certification exists . If the consecutive system adds any treatment, the operator must also hold the subclassification exam for that treatment technology.

The Regulatory Vocabulary Operators Are Tested On

Maximum contaminant level (MCL) — the enforceable ceiling concentration in water delivered to a user. Example: nitrate as nitrogen at 10 mg/L , an acute MCL.

Maximum contaminant level goal (MCLG) — a non-enforceable health goal set with a margin of safety. The MCLG for a microbial pathogen or a genotoxic carcinogen is typically zero.

Treatment technique (TT) — an enforceable process requirement used where measuring the contaminant directly is impractical. Filtration and disinfection under the Surface Water Treatment Rule are treatment techniques, which is why a turbidity exceedance is a treatment technique violation , not an MCL violation.

Action level (AL) — a concentration at the customer's tap that triggers required follow-up. Lead at 0.015 mg/L and copper at 1.3 mg/L are action levels measured at the 90th percentile of the site sample set, not MCLs.

Secondary maximum contaminant level (SMCL) — an aesthetic standard for iron, manganese, color, odor and total dissolved solids. Exceeding an SMCL generates customer complaints, not a health-based violation.

Rule Families That Drive Daily Operation

Rule What it regulates Operator-facing trigger

Surface Water Treatment Rule / Long Term 2 Filtration and disinfection of surface water and groundwater under the direct influence of surface water Combined filter effluent turbidity and daily CT compliance

Revised Total Coliform Rule Distribution system integrity A total coliform positive triggers repeat sampling and, with an E. coli positive, a Level 1 or Level 2 assessment

Ground Water Rule Untreated or inadequately disinfected groundwater Triggered source monitoring after a distribution coliform positive; 4-log virus inactivation where treatment is provided

Stage 2 Disinfectants and Disinfection Byproducts Rule Total trihalomethanes at 0.080 mg/L and five haloacetic acids at 0.060 mg/L Locational running annual average at each monitoring site

Lead and Copper Rule Corrosion of lead service lines and premise plumbing 90th percentile above an action level requires corrosion control treatment, public education and service line work

Radionuclides and Inorganics Gross alpha, radium, uranium, arsenic at 0.010 mg/L Quarterly or annual compliance monitoring by source

Reporting, Notification and Permitting in Pennsylvania

Operators submit compliance results to DEP through the Drinking Water Electronic Lab Reporting (DWELR) system, and certified laboratories report directly as well. Three deadlines are heavily tested:

Public notification tiers. Tier 1 (acute risk, such as an E. coli MCL violation, a nitrate MCL exceedance, or a waterborne disease outbreak) requires notice to customers within 24 hours and immediate verbal contact with the DEP district office. Tier 2 (non-acute MCL or treatment technique violations) requires notice within 30 days . Tier 3 (monitoring and reporting violations, operation under a variance) requires notice within one year .

Consumer Confidence Report. Every community water system must deliver a CCR covering the previous calendar year to customers by July 1 .

Permits. Chapter 109 requires a construction permit and an operation permit before a new source, treatment process or major modification is placed in service. Adding a treatment technology also forces the available operators to hold the matching subclassification, which is the administrative link between Chapter 109 and Chapter 302.

Exam tactic: when a question describes a violation, first identify the system type, then identify whether the standard is an MCL, a treatment technique or an action level. The notification tier follows automatically from that classification.