Study guide
4.4 Mixing, Agitation, and Agitator Scale-Up
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
4.4 Mixing, Agitation, and Agitator Scale-Up
Key Takeaways Explain This Topic AI
Agitator power is correlated through the power number N P = P / ( ρ N 3 D 5 ) N_P = P / (\rho N^3 D^5) N P = P / ( ρ N 3 D 5 ) , where (N) is impeller speed in revolutions per second and (D) is impeller diameter; in fully turbulent baffled flow ( R e > 10 4 Re > 10^4 R e > 1 0 4 ) N P N_P N P is a constant fixed by impeller geometry.
The impeller Reynolds number is R e = ρ N D 2 / μ Re = \rho N D^2 / \mu R e = ρN D 2 / μ using impeller diameter and rotational speed, not pipe diameter and linear velocity; laminar agitation ((Re < 10)) gives N P = K L / R e N_P = K_L/Re N P = K L / R e so that P ∝ μ N 2 D 3 P \propto \mu N^2 D^3 P ∝ μ N 2 D 3 and density drops out entirely.
Representative turbulent power numbers: Rushton six-blade disk turbine N P ≈ 5.5 N_P \approx 5.5 N P ≈ 5.5 (radial, high shear), 45-degree pitched-blade turbine N P ≈ 1.3 N_P \approx 1.3 N P ≈ 1.3 (axial), hydrofoil N P ≈ 0.3 N_P \approx 0.3 N P ≈ 0.3 (axial, high flow per unit power).
Under geometric similarity, constant (P/V) scale-up requires N 2 = N 1 ( D 1 / D 2 ) 2 / 3 N_2 = N_1 (D_1/D_2)^{2/3} N 2 = N 1 ( D 1 / D 2 ) 2/3 while constant tip speed requires N 2 = N 1 ( D 1 / D 2 ) N_2 = N_1 (D_1/D_2) N 2 = N 1 ( D 1 / D 2 ) ; the two criteria conflict, and no single criterion holds power per volume, tip speed, blend time, and Reynolds number constant simultaneously .
Four vertical wall baffles of width (T/12) to (T/10) convert solid-body swirl into axial and radial circulation; removing them collapses power draw, creates a central vortex, and destroys the constancy of N P N_P N P that every scale-up correlation assumes.
Last updated: September 2026
4.4 Mixing, Agitation, and Agitator Scale-Up
The NCEES PE Chemical specification lists Mixing as one of three named subtopics under Fluids Applications, alongside rotating machinery and flow measurement. It is the fluids topic candidates most often skip, and it is examined with the same dimensionless-group machinery as pipe flow — just built from impeller diameter and rotational speed instead of pipe diameter and velocity.
1. Impeller Classification
Impellers are classified by the direction of the discharge stream they produce.
Class Typical impeller Turbulent N P N_P N P Flow number N Q N_Q N Q Best for
Radial Rushton 6-blade disk turbine ≈ 5.5 \approx 5.5 ≈ 5.5 ≈ 0.72 \approx 0.72 ≈ 0.72 Gas dispersion, high shear, immiscible liquid breakup
Axial 45 ∘ ^\circ ∘ pitched-blade turbine (PBT) ≈ 1.3 \approx 1.3 ≈ 1.3 ≈ 0.79 \approx 0.79 ≈ 0.79 Solids suspension, blending, heat transfer
Axial (high efficiency) Hydrofoil ≈ 0.3 \approx 0.3 ≈ 0.3 ≈ 0.55 \approx 0.55 ≈ 0.55 Low-shear blending, large-volume turnover
Close-clearance Anchor, helical ribbon N P = K L / R e N_P = K_L/Re N P = K L / R e — Viscous and non-Newtonian fluids, (Re < 100)
The engineering trade is shear versus flow . A Rushton turbine spends its power creating intense local shear behind the blades, which is what you want to break bubbles or droplets. A hydrofoil spends its power moving bulk liquid, which is what you want to blend a large tank or keep solids off the floor. Selecting a Rushton to blend a low-viscosity storage tank wastes an order of magnitude of shaft power.
- The standard geometrically similar configuration assumed by most correlations is: |<--------- T --------->|
- ___|_______________________|___
- | : : | H = T (liquid depth = tank diameter)
- | : baffle ->| : | D/T = 1/3 (impeller diameter)
- | : _______ | : | C/T = 1/3 (off-bottom clearance)
- | : |__|__| <-- impeller | 4 baffles, width T/10 to T/12
- | : | D | : |
- |___:_______|_________|_____:___|
- C ___|___
- 2. The Dimensionless Groups
Agitation Reynolds number. The characteristic length is the impeller diameter and the characteristic velocity is (ND): R e = ρ N D 2 μ Re = \frac{\rho N D^2}{\mu} R e = μ ρN D 2
(N) must be in revolutions per second for the standard power-number charts. Regimes: laminar below R e ≈ 10 Re \approx 10 R e ≈ 10 , transitional between (10) and 10 4 10^4 1 0 4 , fully turbulent above R e ≈ 10 4 Re \approx 10^4 R e ≈ 1 0 4 .
Power number. The dimensionless shaft power: N P = P ρ N 3 D 5 ⟹ P = N P ρ N 3 D 5 N_P = \frac{P}{\rho N^3 D^5} \quad \Longrightarrow \quad P = N_P \rho N^3 D^5 N P = ρ N 3 D 5 P ⟹ P = N P ρ N 3 D 5
Fully turbulent, baffled: N P N_P N P is a constant set only by impeller and tank geometry. Power scales as N 3 D 5 N^3 D^5 N 3 D 5 and is proportional to density but independent of viscosity .
Laminar: N P = K L / R e N_P = K_L / Re N P = K L / R e , so P = K L μ N 2 D 3 P = K_L \mu N^2 D^3 P = K L μ N 2 D 3 . Power is proportional to viscosity and independent of density .
That inversion is a favorite exam target: doubling the viscosity of a turbulent low-viscosity blend changes shaft power essentially not at all, while doubling the viscosity of a laminar polymer blend doubles it.
Flow number. The pumping capacity of the impeller: N Q = Q N D 3 N_Q = \frac{Q}{N D^3} N Q = N D 3 Q
where (Q) is the volumetric discharge from the impeller. The tank turnover time is (V/Q), and blending requires several turnovers.
Blend time. In the turbulent regime the dimensionless blend time N θ 95 N\theta_{95} N θ 95 is approximately constant for a given geometry. A widely used turbulent correlation is: N θ 95 ≈ 5.2 N P 1 / 3 ( T D ) 2 N \theta_{95} \approx \frac{5.2}{N_P^{1/3}} \left( \frac{T}{D} \right)^{2} N θ 95 ≈ N P 1/3 5.2 ( D T ) 2
For a Rushton turbine at (D/T = 1/3): N θ 95 ≈ ( 5.2 / 1.77 ) ( 9 ) ≈ 26 N\theta_{95} \approx (5.2/1.77)(9) \approx 26 N θ 95 ≈ ( 5.2/1.77 ) ( 9 ) ≈ 26 . At N = 2 rev/s N = 2\text{ rev/s} N = 2 rev/s , θ 95 ≈ 13 s \theta_{95} \approx 13\text{ s} θ 95 ≈ 13 s .
3. Worked Example: Turbulent Power Draw
Problem. A baffled vessel holds water ( ρ = 1,000 kg/m 3 \rho = 1{,}000\text{ kg/m}^3 ρ = 1 , 000 kg/m 3 , μ = 1.0 × 10 − 3 Pa ⋅ s \mu = 1.0 \times 10^{-3}\text{ Pa}\cdot\text{s} μ = 1.0 × 1 0 − 3 Pa ⋅ s ). A Rushton six-blade disk turbine of diameter D = 1.00 m D = 1.00\text{ m} D = 1.00 m turns at 100 rpm 100\text{ rpm} 100 rpm . Take N P = 5.5 N_P = 5.5 N P = 5.5 . Find the regime and the shaft power.
Step 1 — convert speed. N = 100 / 60 = 1.667 rev/s N = 100/60 = 1.667\text{ rev/s} N = 100/60 = 1.667 rev/s .
Step 2 — regime. R e = ( 1,000 ) ( 1.667 ) ( 1.00 ) 2 1.0 × 10 − 3 = 1.67 × 10 6 Re = \frac{(1{,}000)(1.667)(1.00)^2}{1.0 \times 10^{-3}} = 1.67 \times 10^{6} R e = 1.0 × 1 0 − 3 ( 1 , 000 ) ( 1.667 ) ( 1.00 ) 2 = 1.67 × 1 0 6
This is far above 10 4 10^4 1 0 4 , so the flow is fully turbulent and N P = 5.5 N_P = 5.5 N P = 5.5 is a constant.
Step 3 — power. P = N P ρ N 3 D 5 = ( 5.5 ) ( 1,000 ) ( 1.667 ) 3 ( 1.00 ) 5 = ( 5.5 ) ( 1,000 ) ( 4.632 ) = 25,500 W ≈ 25.5 kW P = N_P \rho N^3 D^5 = (5.5)(1{,}000)(1.667)^3(1.00)^5 = (5.5)(1{,}000)(4.632) = 25{,}500\text{ W} \approx 25.5\text{ kW} P = N P ρ N 3 D 5 = ( 5.5 ) ( 1 , 000 ) ( 1.667 ) 3 ( 1.00 ) 5 = ( 5.5 ) ( 1 , 000 ) ( 4.632 ) = 25 , 500 W ≈ 25.5 kW
Note the sensitivity: a 10% speed increase raises power by 1.1 3 = 1.33 1.1^3 = 1.33 1. 1 3 = 1.33 , a 33% increase . Motor sizing on agitators is dominated by the cube law.
4. Scale-Up: The Criteria Conflict
Scale-up from a pilot vessel to production under geometric similarity (all length ratios held constant) forces a choice, because the common criteria are mutually incompatible.
Criterion Speed relation Use when
Constant (P/V) N 2 = N 1 ( D 1 / D 2 ) 2 / 3 N_2 = N_1 (D_1/D_2)^{2/3} N 2 = N 1 ( D 1 / D 2 ) 2/3 Turbulent blending, gas-liquid mass transfer, general default
Constant tip speed π N D \pi N D π N D N 2 = N 1 ( D 1 / D 2 ) N_2 = N_1 (D_1/D_2) N 2 = N 1 ( D 1 / D 2 ) Shear-sensitive systems: crystals, flocs, cell culture
Constant (N) (equal blend time) N 2 = N 1 N_2 = N_1 N 2 = N 1 Almost never — power demand becomes absurd
Constant (Re) N 2 = N 1 ( D 1 / D 2 ) 2 N_2 = N_1 (D_1/D_2)^2 N 2 = N 1 ( D 1 / D 2 ) 2 Laminar/viscous systems only
Worked scale-up. A pilot agitator has D 1 = 0.30 m D_1 = 0.30\text{ m} D 1 = 0.30 m at N 1 = 300 rpm N_1 = 300\text{ rpm} N 1 = 300 rpm ( 5.00 rev/s 5.00\text{ rev/s} 5.00 rev/s ). Scale up geometrically by a factor of 4 to D 2 = 1.20 m D_2 = 1.20\text{ m} D 2 = 1.20 m at constant (P/V). N 2 = N 1 ( D 1 D 2 ) 2 / 3 = 5.00 ( 0.250 ) 2 / 3 = 5.00 ( 0.3969 ) = 1.98 rev/s = 119 rpm N_2 = N_1 \left( \frac{D_1}{D_2} \right)^{2/3} = 5.00 (0.250)^{2/3} = 5.00(0.3969) = 1.98\text{ rev/s} = 119\text{ rpm} N 2 = N 1 ( D 2 D 1 ) 2/3 = 5.00 ( 0.250 ) 2/3 = 5.00 ( 0.3969 ) = 1.98 rev/s = 119 rpm
Check that power per volume really is constant. Volume scales as D 3 D^3 D 3 , so V 2 / V 1 = 4 3 = 64 V_2/V_1 = 4^3 = 64 V 2 / V 1 = 4 3 = 64 . Power scales as N 3 D 5 N^3D^5 N 3 D 5 : P 2 P 1 = ( 0.3969 ) 3 ( 4 ) 5 = ( 0.06252 ) ( 1,024 ) = 64.0 ✓ \frac{P_2}{P_1} = (0.3969)^3 (4)^5 = (0.06252)(1{,}024) = 64.0 \quad \checkmark P 1 P 2 = ( 0.3969 ) 3 ( 4 ) 5 = ( 0.06252 ) ( 1 , 024 ) = 64.0 ✓
Now check tip speed: v t i p , 1 = π ( 5.00 ) ( 0.30 ) = 4.71 m/s v_{tip,1} = \pi(5.00)(0.30) = 4.71\text{ m/s} v t i p , 1 = π ( 5.00 ) ( 0.30 ) = 4.71 m/s and v t i p , 2 = π ( 1.98 ) ( 1.20 ) = 7.47 m/s v_{tip,2} = \pi(1.98)(1.20) = 7.47\text{ m/s} v t i p , 2 = π ( 1.98 ) ( 1.20 ) = 7.47 m/s . Tip speed rose by 4 1 / 3 = 1.59 4^{1/3} = 1.59 4 1/3 = 1.59 . Holding (P/V) constant necessarily increases tip speed and therefore maximum shear. If the product is a shear-sensitive crystal slurry, this scale-up will damage it, and you must instead hold tip speed constant — which then drops (P/V) by a factor of 4 2 / 3 ≈ 2.5 4^{2/3} \approx 2.5 4 2/3 ≈ 2.5 and lengthens blend time.
5. Solids Suspension and Gas Dispersion
Just-suspended speed. The Zwietering correlation gives the impeller speed N j s N_{js} N j s at which no particle rests on the tank floor for more than about one second: N j s = S ν 0.1 d p 0.2 [ g ( ρ s − ρ L ) ρ L ] 0.45 X 0.13 D − 0.85 N_{js} = S\, \nu^{0.1} d_p^{0.2} \left[ \frac{g(\rho_s - \rho_L)}{\rho_L} \right]^{0.45} X^{0.13} D^{-0.85} N j s = S ν 0.1 d p 0.2 [ ρ L g ( ρ s − ρ L ) ] 0.45 X 0.13 D − 0.85
where (X) is the mass ratio of solid to liquid expressed as a percentage and (S) is a geometry constant. The practical lesson is the weak exponents : doubling particle size raises N j s N_{js} N j s by only 2 0.2 = 15 % 2^{0.2} = 15\% 2 0.2 = 15% , and quadrupling solids loading raises it by only 4 0.13 = 19 % 4^{0.13} = 19\% 4 0.13 = 19% , while the impeller diameter term D − 0.85 D^{-0.85} D − 0.85 is strong. A larger, slower impeller suspends solids far more efficiently than a small, fast one.
Gas dispersion. For a sparged vessel the aeration number is N A = Q g / ( N D 3 ) N_A = Q_g/(N D^3) N A = Q g / ( N D 3 ) . As gas rate rises at fixed speed, gas cavities form behind the blades, the effective density seen by the impeller falls, and the gassed power P g P_g P g drops below the ungassed power P 0 P_0 P 0 — typically to P g / P 0 ≈ 0.4 P_g/P_0 \approx 0.4 P g / P 0 ≈ 0.4 to (0.6) for a heavily loaded Rushton turbine. Push further and the impeller floods : gas rises straight up the shaft without being dispersed, and mass transfer collapses. Sizing a motor on ungassed power and then operating gassed leaves the motor oversized; sizing on gassed power and then losing sparger flow overloads the motor , which is why agitator drives on sparged vessels are specified for the ungassed condition.