13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR)
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR)
Key Takeaways Explain This Topic AI
The ideal batch reactor design equation t = N_A0 * integral[dX / (-r_A * V)] simplifies for constant-volume systems to t = C_A0 * integral[dX / (-r_A)], yielding closed-form reaction times of t = C_A0 X/k (zero order), t = (1/k) ln[1/(1-X)] (first order), and t = [1/(k C_A0)] [X/(1-X)] (second order).
Industrial batch sizing must account for total cycle time (t_cycle = t_reaction + t_charge + t_heat/cool + t_discharge + t_clean); ignoring non-reaction downtime leads to severe plant undersizing.
The ideal CSTR design equation V = F_A0 * X / (-r_A)_exit = v_0 * (C_A0 - C_A) / (-r_A)_exit is evaluated strictly at reactor exit conditions because perfect mixing instantaneously dilutes the entire fluid volume to the effluent concentration.
The dimensionless Damköhler number Da = k * tau * C_A0^(n-1) quantifies the ratio of reaction rate to convective transport rate; for first-order CSTR systems, conversion is governed directly by X = Da / (1 + Da).
Connecting N equal-volume CSTRs in series dramatically mitigates the backmixing penalty, with effluent concentration given by C_N = C_A0 / (1 + k * tau_i)^N; as N approaches infinity, the cascade performance converges identically to an ideal plug flow reactor.
Last updated: September 2026
13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR)
Chemical reactor design is founded on the general mole balance for species A A A across any control volume: In − Out + Generation = Accumulation \text{In} - \text{Out} + \text{Generation} = \text{Accumulation} In − Out + Generation = Accumulation F A 0 − F A + ∫ V r A d V = d n A d t F_{A0} - F_A + \int_V r_A dV = \frac{dn_A}{dt} F A 0 − F A + ∫ V r A d V = d t d n A
Where:
F A 0 F_{A0} F A 0 = molar flow rate of species A A A entering the reactor ( mol/s \text{mol/s} mol/s or kmol/h \text{kmol/h} kmol/h ).
F A F_A F A = molar flow rate of species A A A leaving the reactor ( mol/s \text{mol/s} mol/s or kmol/h \text{kmol/h} kmol/h ).
r A r_A r A = rate of generation of species A A A per unit volume ( mol / ( L ⋅ s ) \text{mol}/(\text{L}\cdot\text{s}) mol / ( L ⋅ s ) ).
n A n_A n A = total moles of species A A A within the control volume.
V V V = reactor volume ( L \text{L} L or m 3 \text{m}^3 m 3 ).
The two fundamental backmixed reactor archetypes tested on the NCEES PE Chemical Exam are the Ideal Batch Reactor (unsteady-state, closed system) and the Continuous Stirred-Tank Reactor (CSTR) (steady-state, open, continuous-flow system).
1. Ideal Batch Reactor Design and Kinetics
An ideal batch reactor operates as a closed system. Reactants are charged into a vessel at time t = 0 t = 0 t = 0 , thoroughly mixed, and allowed to react over a specified residence time. No fluid enters or leaves during the reaction ( F A 0 = 0 , F A = 0 F_{A0} = 0, F_A = 0 F A 0 = 0 , F A = 0 ). Ideal Batch Reactor (Unsteady State)
- ------------------------------------
- Motor & Impeller Stirrer
- |
- [===]
- |
- +-------------+
- | Uniform |
- | Liquid | dn_A / dt = r_A * V
- | Mixture | No feed in, no product out
- | | during reaction period
- +-------------+
- General Mole Balance and Conversion
Setting inlet and outlet streams to zero in the general balance: r A V = d n A d t ⟹ − r A V = − d n A d t r_A V = \frac{dn_A}{dt} \implies -r_A V = -\frac{dn_A}{dt} r A V = d t d n A ⟹ − r A V = − d t d n A
Defining fractional conversion X X X based on initial moles charged ( n A 0 n_{A0} n A 0 ): n A = n A 0 ( 1 − X ) ⟹ d n A = − n A 0 d X n_A = n_{A0} (1 - X) \implies dn_A = -n_{A0} dX n A = n A 0 ( 1 − X ) ⟹ d n A = − n A 0 d X
Substituting d n A dn_A d n A into the balance yields the general batch reactor design equation : t = n A 0 ∫ 0 X d X ( − r A ) V t = n_{A0} \int_0^X \frac{dX}{(-r_A) V} t = n A 0 ∫ 0 X ( − r A ) V d X
Constant-Volume Liquid Systems ( V = V 0 V = V_0 V = V 0 )
For liquid-phase reactions and constant-volume gas reactions, the fluid volume remains constant throughout the cycle ( V = V 0 V = V_0 V = V 0 ). Factoring V V V out and noting C A 0 = n A 0 / V 0 C_{A0} = n_{A0} / V_0 C A 0 = n A 0 / V 0 : t = C A 0 ∫ 0 X d X − r A = − ∫ C A 0 C A d C A − r A t = C_{A0} \int_0^X \frac{dX}{-r_A} = -\int_{C_{A0}}^{C_A} \frac{dC_A}{-r_A} t = C A 0 ∫ 0 X − r A d X = − ∫ C A 0 C A − r A d C A
Analytical Solutions for Constant-Volume Batch Kinetics
Zero-Order Reaction ( − r A = k -r_A = k − r A = k ): t = C A 0 ∫ 0 X d X k = C A 0 X k t = C_{A0} \int_0^X \frac{dX}{k} = \frac{C_{A0} X}{k} t = C A 0 ∫ 0 X k d X = k C A 0 X
First-Order Reaction ( − r A = k C A = k C A 0 ( 1 − X ) -r_A = k C_A = k C_{A0}(1 - X) − r A = k C A = k C A 0 ( 1 − X ) ): t = C A 0 ∫ 0 X d X k C A 0 ( 1 − X ) = 1 k ∫ 0 X d X 1 − X = 1 k ln ( 1 1 − X ) = 1 k ln ( C A 0 C A ) t = C_{A0} \int_0^X \frac{dX}{k C_{A0} (1 - X)} = \frac{1}{k} \int_0^X \frac{dX}{1 - X} = \frac{1}{k} \ln\left( \frac{1}{1 - X} \right) = \frac{1}{k} \ln\left( \frac{C_{A0}}{C_A} \right) t = C A 0 ∫ 0 X k C A 0 ( 1 − X ) d X = k 1 ∫ 0 X 1 − X d X = k 1 ln ( 1 − X 1 ) = k 1 ln ( C A C A 0 )
Second-Order Reaction ( 2 A → Products 2A \to \text{Products} 2 A → Products , − r A = k C A 2 = k C A 0 2 ( 1 − X ) 2 -r_A = k C_A^2 = k C_{A0}^2(1 - X)^2 − r A = k C A 2 = k C A 0 2 ( 1 − X ) 2 ): t = C A 0 ∫ 0 X d X k C A 0 2 ( 1 − X ) 2 = 1 k C A 0 ∫ 0 X d X ( 1 − X ) 2 = 1 k C A 0 ( X 1 − X ) = 1 k ( 1 C A − 1 C A 0 ) t = C_{A0} \int_0^X \frac{dX}{k C_{A0}^2 (1 - X)^2} = \frac{1}{k C_{A0}} \int_0^X \frac{dX}{(1 - X)^2} = \frac{1}{k C_{A0}} \left( \frac{X}{1 - X} \right) = \frac{1}{k} \left( \frac{1}{C_A} - \frac{1}{C_{A0}} \right) t = C A 0 ∫ 0 X k C A 0 2 ( 1 − X ) 2 d X = k C A 0 1 ∫ 0 X ( 1 − X ) 2 d X = k C A 0 1 ( 1 − X X ) = k 1 ( C A 1 − C A 0 1 )
2. Batch Cycle Time, Downtime, and Industrial Productivity Sizing
In industrial practice (e.g., pharmaceutical synthesis or polymer compounding), a batch reactor does not produce continuously. Sizing a batch facility to satisfy an annual production quota requires analyzing the full batch cycle time ( t c y c l e t_{cycle} t cyc l e ): t c y c l e = t r e a c t i o n + t d e a d t_{cycle} = t_{reaction} + t_{dead} t cyc l e = t re a c t i o n + t d e a d t d e a d = t c h a r g e + t h e a t / c o o l + t d i s c h a r g e + t c l e a n t_{dead} = t_{charge} + t_{heat/cool} + t_{discharge} + t_{clean} t d e a d = t c ha r g e + t h e a t / coo l + t d i sc ha r g e + t c l e an
Where t d e a d t_{dead} t d e a d represents non-productive downtime spent charging reagents, heating or cooling the vessel, transferring products, and cleaning or sterilizing between batches.
Sizing Equations for Production Quotas
Let:
P ˙ \dot{P} P ˙ = required production rate of product ( mol/day \text{mol/day} mol/day or kg/yr \text{kg/yr} kg/yr ).
t o p t_{op} t o p = operating availability of the plant per year (e.g., 300 days/yr × 24 h/day = 7 , 200 h/yr 300\text{ days/yr} \times 24\text{ h/day} = 7,\!200\text{ h/yr} 300 days/yr × 24 h/day = 7 , 200 h/yr ).
The number of batches that can be executed per year is: N b a t c h e s = t o p t c y c l e N_{batches} = \frac{t_{op}}{t_{cycle}} N ba t c h es = t cyc l e t o p
The moles of reactant A A A that must be processed per batch is: n A 0 = P ˙ ⋅ t c y c l e X ⋅ t o p n_{A0} = \frac{\dot{P} \cdot t_{cycle}}{X \cdot t_{op}} n A 0 = X ⋅ t o p P ˙ ⋅ t cyc l e
The required reactor fluid volume is: V = n A 0 C A 0 = P ˙ ⋅ t c y c l e C A 0 ⋅ X ⋅ t o p V = \frac{n_{A0}}{C_{A0}} = \frac{\dot{P} \cdot t_{cycle}}{C_{A0} \cdot X \cdot t_{op}} V = C A 0 n A 0 = C A 0 ⋅ X ⋅ t o p P ˙ ⋅ t cyc l e
Important
The Downtime Sizing Penalty:
If t r e a c t i o n = 2.0 h t_{reaction} = 2.0\text{ h} t re a c t i o n = 2.0 h and t d e a d = 4.0 h t_{dead} = 4.0\text{ h} t d e a d = 4.0 h , total cycle time is 6.0 h 6.0\text{ h} 6.0 h . The reaction occupies only 33 % 33\% 33% of the total cycle! Designing reactor capacity based solely on t r e a c t i o n t_{reaction} t re a c t i o n will cause a 67 % 67\% 67% production deficit.
3. Continuous Stirred-Tank Reactor (CSTR) Fundamentals
The Continuous Stirred-Tank Reactor (CSTR) , also called a backmix reactor , is an agitated vessel with continuous feed and effluent streams. Continuous Stirred-Tank Reactor (CSTR)
- ------------------------------------
- Feed In (F_A0, v_0, C_A0)
- |
- v
- +-------------+
- | PERFECT |
- | MIXING |-----> Effluent Out (F_A, v, C_A)
- | (-r_A)_exit| C_A,exit = C_A,vessel
- +-------------+ (-r_A)_exit = (-r_A)_vessel
The CSTR Ideal Modeling Assumptions:
Perfect Spatial Homogeneity: The agitation is sufficiently intense that the fluid inside the tank is perfectly mixed. Temperature, concentration, and reaction rate are uniform throughout the vessel volume.
Effluent Identity: Because mixing is instantaneous, the fluid stream exiting the vessel has the exact same composition, temperature, and reaction rate as the bulk fluid inside the vessel: C A , e x i t = C A , v e s s e l , ( − r A ) e x i t = ( − r A ) v e s s e l C_{A,exit} = C_{A,vessel}, \qquad (-r_A)_{exit} = (-r_A)_{vessel} C A , e x i t = C A , v esse l , ( − r A ) e x i t = ( − r A ) v esse l
Steady-State Operation: There is no accumulation of mass or energy ( d n A / d t = 0 dn_A / dt = 0 d n A / d t = 0 ).
Derivation of the CSTR Design Equation
Applying the steady-state mole balance ( F A 0 − F A + r A V = 0 F_{A0} - F_A + r_A V = 0 F A 0 − F A + r A V = 0 ): F A 0 − F A = ( − r A ) V F_{A0} - F_A = (-r_A) V F A 0 − F A = ( − r A ) V
Expressing molar flow in terms of conversion ( F A = F A 0 ( 1 − X ) ⟹ F A 0 − F A = F A 0 X F_A = F_{A0}(1 - X) \implies F_{A0} - F_A = F_{A0} X F A = F A 0 ( 1 − X ) ⟹ F A 0 − F A = F A 0 X ): V = F A 0 X ( − r A ) e x i t V = \frac{F_{A0} X}{(-r_A)_{exit}} V = ( − r A ) e x i t F A 0 X
In terms of volumetric flow rate v 0 v_0 v 0 ( L/s \text{L/s} L/s or m 3 /h \text{m}^3\text{/h} m 3 /h ) for constant fluid density ( v = v 0 v = v_0 v = v 0 ): F A 0 = v 0 C A 0 , F A = v 0 C A F_{A0} = v_0 C_{A0}, \qquad F_A = v_0 C_A F A 0 = v 0 C A 0 , F A = v 0 C A V = v 0 ( C A 0 − C A ) ( − r A ) e x i t V = \frac{v_0 (C_{A0} - C_A)}{(-r_A)_{exit}} V = ( − r A ) e x i t v 0 ( C A 0 − C A )
4. Space Time ( τ \tau τ ), Space Velocity ( S V SV S V ), and Damköhler Number ( D a Da D a )
In continuous reactor analysis, operating performance is normalized against fluid throughput.
Space Time ( τ \tau τ )
Space time ( τ \tau τ ) represents the time required to process one reactor volume of feed measured at entering conditions: τ ≡ V v 0 = C A 0 X ( − r A ) e x i t = C A 0 − C A ( − r A ) e x i t \tau \equiv \frac{V}{v_0} = \frac{C_{A0} X}{(-r_A)_{exit}} = \frac{C_{A0} - C_A}{(-r_A)_{exit}} τ ≡ v 0 V = ( − r A ) e x i t C A 0 X = ( − r A ) e x i t C A 0 − C A
Where:
V V V = active reactor volume ( m 3 \text{m}^3 m 3 or L \text{L} L ).
v 0 v_0 v 0 = volumetric feed flow rate ( m 3 /s \text{m}^3\text{/s} m 3 /s or L/min \text{L/min} L/min ).
τ \tau τ = space time (units of time: s \text{s} s , min \text{min} min , or h \text{h} h ).
Space Velocity ( S V SV S V )
Space velocity ( S V SV S V ) is the reciprocal of space time, measuring the number of reactor volumes of feed that can be processed per unit time: S V ≡ 1 τ = v 0 V SV \equiv \frac{1}{\tau} = \frac{v_0}{V} S V ≡ τ 1 = V v 0
Common industrial metrics include:
LHSV (Liquid Hourly Space Velocity): Volumetric liquid feed rate at 60 ∘ F 60^\circ\text{F} 6 0 ∘ F divided by catalyst/reactor volume ( h − 1 \text{h}^{-1} h − 1 ).
GHSV (Gas Hourly Space Velocity): Volumetric gas feed rate at standard conditions (STP: 0 ∘ C , 1 atm 0^\circ\text{C}, 1\text{ atm} 0 ∘ C , 1 atm ) divided by reactor volume ( h − 1 \text{h}^{-1} h − 1 ).
The Damköhler Number ( D a Da D a )
The Damköhler number ( D a Da D a ) is a dimensionless parameter expressing the ratio of characteristic chemical reaction rate to convective fluid transport rate: D a ≡ Reaction Rate Convective Flow Rate = ( − r A 0 ) V F A 0 = ( − r A 0 ) τ C A 0 Da \equiv \frac{\text{Reaction Rate}}{\text{Convective Flow Rate}} = \frac{(-r_{A0}) V}{F_{A0}} = \frac{(-r_{A0}) \tau}{C_{A0}} D a ≡ Convective Flow Rate Reaction Rate = F A 0 ( − r A 0 ) V = C A 0 ( − r A 0 ) τ
For a first-order reaction ( − r A = k C A -r_A = k C_A − r A = k C A ): D a = k τ Da = k \tau D a = k τ
For a second-order reaction ( − r A = k C A 2 -r_A = k C_A^2 − r A = k C A 2 ): D a = k C A 0 τ Da = k C_{A0} \tau D a = k C A 0 τ
Significance of D a Da D a :
D a ≪ 0.1 Da \ll 0.1 D a ≪ 0.1 : Slow reaction / short residence time; conversion is very low ( X ≈ D a X \approx Da X ≈ D a ).
D a ≫ 10 Da \gg 10 D a ≫ 10 : Fast reaction / long residence time; conversion approaches complete equilibrium or stoichiometric completion ( X → 1.0 X \to 1.0 X → 1.0 ).
- 5. Analytical Solutions for CSTR Performance
- 1. First-Order Reaction in a CSTR
Substituting − r A = k C A = k C A 0 ( 1 − X ) -r_A = k C_A = k C_{A0}(1 - X) − r A = k C A = k C A 0 ( 1 − X ) into the space time definition: τ = C A 0 X k C A 0 ( 1 − X ) = X k ( 1 − X ) \tau = \frac{C_{A0} X}{k C_{A0} (1 - X)} = \frac{X}{k (1 - X)} τ = k C A 0 ( 1 − X ) C A 0 X = k ( 1 − X ) X
Multiplying by k k k yields D a = k τ = X 1 − X Da = k \tau = \frac{X}{1 - X} D a = k τ = 1 − X X . Rearranging explicitly for conversion X X X : X = k τ 1 + k τ = D a 1 + D a X = \frac{k \tau}{1 + k \tau} = \frac{Da}{1 + Da} X = 1 + k τ k τ = 1 + D a D a
In terms of effluent concentration C A C_A C A : C A = C A 0 ( 1 − X ) = C A 0 1 + k τ = C A 0 1 + D a C_A = C_{A0} (1 - X) = \frac{C_{A0}}{1 + k \tau} = \frac{C_{A0}}{1 + Da} C A = C A 0 ( 1 − X ) = 1 + k τ C A 0 = 1 + D a C A 0
2. Second-Order Reaction in a CSTR ( 2 A → Products 2A \to \text{Products} 2 A → Products , − r A = k C A 2 -r_A = k C_A^2 − r A = k C A 2 )
Substituting into the CSTR design equation: τ = C A 0 − C A k C A 2 ⟹ k τ C A 2 + C A − C A 0 = 0 \tau = \frac{C_{A0} - C_A}{k C_A^2} \implies k \tau C_A^2 + C_A - C_{A0} = 0 τ = k C A 2 C A 0 − C A ⟹ k τ C A 2 + C A − C A 0 = 0
Applying the quadratic formula and retaining the physically meaningful positive root: C A = − 1 + 1 + 4 k τ C A 0 2 k τ = − 1 + 1 + 4 D a 2 D a C A 0 C_A = \frac{-1 + \sqrt{1 + 4 k \tau C_{A0}}}{2 k \tau} = \frac{-1 + \sqrt{1 + 4 Da}}{2 Da} C_{A0} C A = 2 k τ − 1 + 1 + 4 k τ C A 0 = 2 D a − 1 + 1 + 4 D a C A 0
Conversion X X X is: X = 1 − C A C A 0 = ( 1 + 2 D a ) − 1 + 4 D a 2 D a X = 1 - \frac{C_A}{C_{A0}} = \frac{(1 + 2 Da) - \sqrt{1 + 4 Da}}{2 Da} X = 1 − C A 0 C A = 2 D a ( 1 + 2 D a ) − 1 + 4 D a
6. Continuous Stirred-Tank Reactors in Series (CSTR Cascades)
A major disadvantage of a single CSTR is the backmixing penalty : the entire reactor operates at the lowest possible reactant concentration ( C A , e x i t C_{A,exit} C A , e x i t ), resulting in the lowest possible reaction rate and requiring a large volume. Connecting multiple smaller CSTRs in series mitigates this penalty. CSTR Cascade in Series (N Tanks)
- -------------------------------
- v_0, C_A0 ---> [ Tank 1 ] ---> [ Tank 2 ] ---> ... ---> [ Tank N ] ---> v_0, C_AN
- V_1, C_A1 V_2, C_A2 V_N, C_AN
- First-Order Reaction in N N N Equal-Volume CSTRs
Consider a train of N N N identical CSTRs in series, each having volume V i = V t o t a l / N V_i = V_{total} / N V i = V t o t a l / N and individual space time τ i = V i / v 0 = τ t o t a l / N \tau_i = V_i / v_0 = \tau_{total} / N τ i = V i / v 0 = τ t o t a l / N .
For Tank 1: C A 1 = C A 0 1 + k τ i C_{A1} = \frac{C_{A0}}{1 + k \tau_i} C A 1 = 1 + k τ i C A 0
For Tank 2: C A 2 = C A 1 1 + k τ i = C A 0 ( 1 + k τ i ) 2 C_{A2} = \frac{C_{A1}}{1 + k \tau_i} = \frac{C_{A0}}{(1 + k \tau_i)^2} C A 2 = 1 + k τ i C A 1 = ( 1 + k τ i ) 2 C A 0
Extending by induction to the N N N -th tank: C A N = C A 0 ( 1 + k τ i ) N = C A 0 ( 1 + k τ t o t a l N ) N C_{AN} = \frac{C_{A0}}{(1 + k \tau_i)^N} = \frac{C_{A0}}{\left( 1 + k \frac{\tau_{total}}{N} \right)^N} C A N = ( 1 + k τ i ) N C A 0 = ( 1 + k N τ t o t a l ) N C A 0
The overall conversion across the entire cascade is: X N = 1 − C A N C A 0 = 1 − 1 ( 1 + k τ i ) N X_N = 1 - \frac{C_{AN}}{C_{A0}} = 1 - \frac{1}{(1 + k \tau_i)^N} X N = 1 − C A 0 C A N = 1 − ( 1 + k τ i ) N 1
Convergence to Plug Flow as N → ∞ N \to \infty N → ∞
From calculus, the definition of the natural exponential is lim N → ∞ ( 1 + k τ N ) N = e k τ \lim_{N \to \infty} \left( 1 + \frac{k \tau}{N} \right)^N = e^{k \tau} lim N → ∞ ( 1 + N k τ ) N = e k τ . Therefore: lim N → ∞ C A N = C A 0 e − k τ t o t a l \lim_{N \to \infty} C_{AN} = C_{A0} e^{-k \tau_{total}} N → ∞ lim C A N = C A 0 e − k τ t o t a l
As the number of tanks in series approaches infinity, the performance of a CSTR cascade converges identically to that of an ideal Plug Flow Reactor (PFR)! In practice, a cascade of just 3 to 5 CSTRs achieves over 85 % 85\% 85% to 90 % 90\% 90% of the volume savings of an ideal PFR while retaining individual vessel agitation, temperature control, and slurry-handling capability.
7. Summary Comparison Table: Batch vs. CSTR vs. CSTR Cascades
- Design Metric Ideal Batch Reactor Single CSTR N N N Equal CSTRs in Series
- Flow Mode Unsteady state (closed) Steady state (continuous) Steady state (continuous)
Concentration Profile Uniform spatially; drops with time Uniform spatially and temporally ( C e x i t C_{exit} C e x i t ) Stepped profile; drops stage by stage
Design Equation t = C A 0 ∫ 0 X d X − r A t = C_{A0} \int_0^X \frac{dX}{-r_A} t = C A 0 ∫ 0 X − r A d X V = F A 0 X ( − r A ) e x i t V = \frac{F_{A0} X}{(-r_A)_{exit}} V = ( − r A ) e x i t F A 0 X V i = F A 0 ( X i − X i − 1 ) ( − r A ) i V_i = \frac{F_{A0} (X_i - X_{i-1})}{(-r_A)_i} V i = ( − r A ) i F A 0 ( X i − X i − 1 )
1st-Order Solution C A = C A 0 e − k t C_A = C_{A0} e^{-k t} C A = C A 0 e − k t C A = C A 0 1 + k τ C_A = \frac{C_{A0}}{1 + k \tau} C A = 1 + k τ C A 0 C A N = C A 0 ( 1 + k τ i ) N C_{AN} = \frac{C_{A0}}{(1 + k \tau_i)^N} C A N = ( 1 + k τ i ) N C A 0
Relative Size for Same X X X Small volume, but downtime lowers output Largest volume (operates at lowest rate) Moderately small (approaches PFR as N ↑ N \uparrow N ↑ )
Temperature Control Unsteady heat transfer; difficult Excellent (large thermal mass, uniform T T T ) Excellent stage-by-stage control
Primary Industrial Use Pharmaceuticals, fine chemicals, dyes Liquid polymers, waste neutralization Petrochemical alkylation, nitration
- 8. Step-by-Step Worked Numerical Example: Reactor Sizing Comparison for Industrial Synthesis
- Problem Statement
A specialty ester is synthesized via an irreversible liquid-phase first-order reaction: A ⟶ Products A \longrightarrow \text{Products} A ⟶ Products
The feed enters at concentration C A 0 = 2.00 mol/L C_{A0} = 2.00\text{ mol/L} C A 0 = 2.00 mol/L with volumetric flow rate v 0 = 10.0 L/min v_0 = 10.0\text{ L/min} v 0 = 10.0 L/min ( 0.0100 m 3 /min 0.0100\text{ m}^3\text{/min} 0.0100 m 3 /min ). At the reaction temperature, the rate constant is k = 0.0500 min − 1 k = 0.0500\text{ min}^{-1} k = 0.0500 min − 1 . The target conversion is 85.0 % 85.0\% 85.0% ( X = 0.850 X = 0.850 X = 0.850 ).
Calculate:
The required volume ( V V V ) and space time ( τ \tau τ ) for a single CSTR .
The reaction time ( t r x n t_{rxn} t r x n ) for a batch reactor , and the total cycle time ( t c y c l e t_{cycle} t cyc l e ) assuming charging, heating, discharging, and cleaning downtime is t d e a d = 45.0 min t_{dead} = 45.0\text{ min} t d e a d = 45.0 min .
The batch reactor volume ( V b a t c h V_{batch} V ba t c h ) required to match the continuous plant capacity ( F A 0 = 20.0 mol/min = 28 , 800 mol/day F_{A0} = 20.0\text{ mol/min} = 28,\!800\text{ mol/day} F A 0 = 20.0 mol/min = 28 , 800 mol/day ) operating 24.0 h/day 24.0\text{ h/day} 24.0 h/day .
The required individual volume ( V i V_i V i ) and total volume ( V t o t a l V_{total} V t o t a l ) for two identical CSTRs in series , and the percentage volume reduction achieved relative to the single CSTR.
Step 1: Single CSTR Sizing
For 85.0 % 85.0\% 85.0% conversion: C A , e x i t = C A 0 ( 1 − X ) = 2.00 mol/L × ( 1 − 0.850 ) = 0.300 mol/L C_{A,exit} = C_{A0}(1 - X) = 2.00\text{ mol/L} \times (1 - 0.850) = 0.300\text{ mol/L} C A , e x i t = C A 0 ( 1 − X ) = 2.00 mol/L × ( 1 − 0.850 ) = 0.300 mol/L ( − r A ) e x i t = k C A , e x i t = 0.0500 min − 1 × 0.300 mol/L = 0.0150 mol / ( L ⋅ min ) (-r_A)_{exit} = k C_{A,exit} = 0.0500\text{ min}^{-1} \times 0.300\text{ mol/L} = 0.0150\text{ mol}/(\text{L}\cdot\text{min}) ( − r A ) e x i t = k C A , e x i t = 0.0500 min − 1 × 0.300 mol/L = 0.0150 mol / ( L ⋅ min )
Using the CSTR design equation: τ = C A 0 X ( − r A ) e x i t = 2.00 mol/L × 0.850 0.0150 mol / ( L ⋅ min ) = 1.70 0.0150 = 113.33 min ( 1.889 h ) \tau = \frac{C_{A0} X}{(-r_A)_{exit}} = \frac{2.00\text{ mol/L} \times 0.850}{0.0150\text{ mol}/(\text{L}\cdot\text{min})} = \frac{1.70}{0.0150} = \mathbf{113.33\text{ min}} \quad (1.889\text{ h}) τ = ( − r A ) e x i t C A 0 X = 0.0150 mol / ( L ⋅ min ) 2.00 mol/L × 0.850 = 0.0150 1.70 = 113.33 min ( 1.889 h ) V C S T R = v 0 ⋅ τ = 10.0 L/min × 113.33 min = 1 , 133.3 L ( 1.133 m 3 ) V_{CSTR} = v_0 \cdot \tau = 10.0\text{ L/min} \times 113.33\text{ min} = \mathbf{1,\!133.3\text{ L}} \quad (1.133\text{ m}^3) V CSTR = v 0 ⋅ τ = 10.0 L/min × 113.33 min = 1 , 133.3 L ( 1.133 m 3 )
Step 2: Batch Reaction Time and Cycle Time
For a constant-volume batch reactor with first-order kinetics: t r x n = 1 k ln ( 1 1 − X ) = 1 0.0500 min − 1 ln ( 1 1 − 0.850 ) = 20.0 × ln ( 6.6667 ) = 20.0 × 1.89712 = 37.94 min t_{rxn} = \frac{1}{k} \ln\left( \frac{1}{1 - X} \right) = \frac{1}{0.0500\text{ min}^{-1}} \ln\left( \frac{1}{1 - 0.850} \right) = 20.0 \times \ln(6.6667) = 20.0 \times 1.89712 = \mathbf{37.94\text{ min}} t r x n = k 1 ln ( 1 − X 1 ) = 0.0500 min − 1 1 ln ( 1 − 0.850 1 ) = 20.0 × ln ( 6.6667 ) = 20.0 × 1.89712 = 37.94 min
Total batch cycle time: t c y c l e = t r x n + t d e a d = 37.94 min + 45.00 min = 82.94 min ( 1.382 h ) t_{cycle} = t_{rxn} + t_{dead} = 37.94\text{ min} + 45.00\text{ min} = \mathbf{82.94\text{ min}} \quad (1.382\text{ h}) t cyc l e = t r x n + t d e a d = 37.94 min + 45.00 min = 82.94 min ( 1.382 h )
Step 3: Batch Reactor Volume for Equivalent Throughput
Daily production throughput required: N ˙ A = v 0 C A 0 × 1 , 440 min/day = 10.0 L/min × 2.00 mol/L × 1 , 440 = 28 , 800 mol/day \dot{N}_A = v_0 C_{A0} \times 1,\!440\text{ min/day} = 10.0\text{ L/min} \times 2.00\text{ mol/L} \times 1,\!440 = 28,\!800\text{ mol/day} N ˙ A = v 0 C A 0 × 1 , 440 min/day = 10.0 L/min × 2.00 mol/L × 1 , 440 = 28 , 800 mol/day
Number of batches possible per 24-hour operating day: N b a t c h e s = 1 , 440 min/day 82.94 min/batch = 17.362 batches/day N_{batches} = \frac{1,\!440\text{ min/day}}{82.94\text{ min/batch}} = 17.362\text{ batches/day} N ba t c h es = 82.94 min/batch 1 , 440 min/day = 17.362 batches/day
Moles of A A A charged per batch: n A 0 = 28 , 800 mol/day 17.362 batches/day = 1 , 658.8 mol/batch n_{A0} = \frac{28,\!800\text{ mol/day}}{17.362\text{ batches/day}} = 1,\!658.8\text{ mol/batch} n A 0 = 17.362 batches/day 28 , 800 mol/day = 1 , 658.8 mol/batch
Required batch vessel working volume: V b a t c h = n A 0 C A 0 = 1 , 658.8 mol 2.00 mol/L = 829.4 L ( 0.829 m 3 ) V_{batch} = \frac{n_{A0}}{C_{A0}} = \frac{1,\!658.8\text{ mol}}{2.00\text{ mol/L}} = \mathbf{829.4\text{ L}} \quad (0.829\text{ m}^3) V ba t c h = C A 0 n A 0 = 2.00 mol/L 1 , 658.8 mol = 829.4 L ( 0.829 m 3 )
Step 4: Two Identical CSTRs in Series Sizing
For two equal-volume CSTRs in series: C A 2 C A 0 = 1 − X = 1 − 0.850 = 0.150 \frac{C_{A2}}{C_{A0}} = 1 - X = 1 - 0.850 = 0.150 C A 0 C A 2 = 1 − X = 1 − 0.850 = 0.150 C A 2 C A 0 = 1 ( 1 + k τ i ) 2 = 0.150 ⟹ ( 1 + k τ i ) 2 = 1 0.150 = 6.6667 \frac{C_{A2}}{C_{A0}} = \frac{1}{(1 + k \tau_i)^2} = 0.150 \implies (1 + k \tau_i)^2 = \frac{1}{0.150} = 6.6667 C A 0 C A 2 = ( 1 + k τ i ) 2 1 = 0.150 ⟹ ( 1 + k τ i ) 2 = 0.150 1 = 6.6667 1 + k τ i = 6.6667 = 2.5820 ⟹ k τ i = 1.5820 1 + k \tau_i = \sqrt{6.6667} = 2.5820 \implies k \tau_i = 1.5820 1 + k τ i = 6.6667 = 2.5820 ⟹ k τ i = 1.5820 τ i = 1.5820 0.0500 min − 1 = 31.64 min \tau_i = \frac{1.5820}{0.0500\text{ min}^{-1}} = \mathbf{31.64\text{ min}} τ i = 0.0500 min − 1 1.5820 = 31.64 min
Individual tank volume: V i = v 0 ⋅ τ i = 10.0 L/min × 31.64 min = 316.4 L V_i = v_0 \cdot \tau_i = 10.0\text{ L/min} \times 31.64\text{ min} = \mathbf{316.4\text{ L}} V i = v 0 ⋅ τ i = 10.0 L/min × 31.64 min = 316.4 L
Total cascade volume: V t o t a l = 2 × V i = 2 × 316.4 L = 632.8 L V_{total} = 2 \times V_i = 2 \times 316.4\text{ L} = \mathbf{632.8\text{ L}} V t o t a l = 2 × V i = 2 × 316.4 L = 632.8 L
Percentage volume reduction compared to the single CSTR: Reduction = V C S T R − V t o t a l V C S T R × 100 % = 1 , 133.3 − 632.8 1 , 133.3 × 100 % = 500.5 1 , 133.3 × 100 % = 44.2 % \text{Reduction} = \frac{V_{CSTR} - V_{total}}{V_{CSTR}} \times 100\% = \frac{1,\!133.3 - 632.8}{1,\!133.3} \times 100\% = \frac{500.5}{1,\!133.3} \times 100\% = \mathbf{44.2\%} Reduction = V CSTR V CSTR − V t o t a l × 100% = 1 , 133.3 1 , 133.3 − 632.8 × 100% = 1 , 133.3 500.5 × 100% = 44.2%
Splitting the single CSTR into just two equal-volume stages eliminates over 44 % 44\% 44% of the required total reactor volume!
- 9. Critical PE Exam Traps & Pitfalls
- Trap 1: Evaluating CSTR Rate at Inlet or Average Conditions
Because an ideal CSTR is completely backmixed, fluid elements mix instantaneously. The reaction rate is strictly evaluated at the exit concentration ( C A , e x i t C_{A,exit} C A , e x i t ), NOT at C A 0 C_{A0} C A 0 and NOT at the arithmetic average ( C A 0 + C A ) / 2 (C_{A0} + C_A)/2 ( C A 0 + C A ) /2 . Evaluating at average conditions will drastically underestimate the required CSTR size.
Trap 2: Omitting Downtime in Batch Sizing
When sizing an industrial batch plant, never calculate vessel volume from t r x n t_{rxn} t r x n alone. Clean-in-place (CIP), steam-in-place (SIP), charging, and discharging operations frequently take longer than the chemical reaction itself. Always use t c y c l e = t r x n + t d e a d t_{cycle} = t_{rxn} + t_{dead} t cyc l e = t r x n + t d e a d .
Trap 3: Confusing Cascade Space Time with Individual Tank Space Time
In a CSTR cascade equation C N = C A 0 / ( 1 + k τ i ) N C_N = C_{A0} / (1 + k \tau_i)^N C N = C A 0 / ( 1 + k τ i ) N , the variable τ i \tau_i τ i is the space time of one individual tank ( V i / v 0 V_i / v_0 V i / v 0 ), NOT the total cascade space time. The total space time is τ t o t a l = N τ i \tau_{total} = N \tau_i τ t o t a l = N τ i . Substituting τ t o t a l \tau_{total} τ t o t a l into the denominator produces errors greater than 300 % 300\% 300% .
Trap 4: Confusing Space Time ( τ \tau τ ) with True Mean Residence Time ( t ˉ \bar{t} t ˉ )
Space time is defined strictly as τ ≡ V / v 0 \tau \equiv V / v_0 τ ≡ V / v 0 based on entering volumetric flow rate. For constant-density liquid systems, space time equals the mean residence time ( τ = t ˉ \tau = \bar{t} τ = t ˉ ). However, for gas-phase reactions where temperature, pressure, or total moles change, volumetric flow varies ( v ≠ v 0 v \neq v_0 v = v 0 ), meaning space time τ \tau τ diverges from true mean residence time.