Study guide

13.4 Plug Flow Reactors (PFR) and Reactor Combinations

PE Chemical Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the PE Chemical Exam How to Use This Guide and the NCEES Handbook

2 Chapter 1: Material Balances & Flowsheet Calculations

1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations

3 Chapter 2: Energy Balances & Thermochemistry

2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances

4 Chapter 3: Fluid Statics & Incompressible Pipe Flow

3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations

5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow

4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up

6 Chapter 5: Thermodynamic Laws & Fundamental Relations

5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations

7 Chapter 6: Real Gases & Equations of State

6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions

8 Chapter 7: Phase & Chemical Reaction Equilibria

7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation

9 Chapter 8: Heat Transfer Mechanisms & Conduction

8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange

10 Chapter 9: Heat Exchanger Design & Phase Change

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances

11 Chapter 10: Mass Transfer Fundamentals & Diffusion

10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)

12 Chapter 11: Distillation Operations

11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components

13 Chapter 12: Rate-Controlled & Equilibrium Separations

12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations

14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors

13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations

15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis

14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models

16 Chapter 15: Physical & Transport Properties of Fluids

15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles

17 Chapter 16: Materials of Construction & Corrosion

16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention

18 Chapter 17: Process Safety & Pressure Relief Systems

17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment

19 Chapter 18: Process Control & Engineering Economics

18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems

20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance

19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation

21 Chapter 20: Plant Operation, Reliability & Continuous Improvement

20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting

13.4 Plug Flow Reactors (PFR) and Reactor Combinations

Key Takeaways Explain This Topic AI

The ideal PFR design equation V = F_A0 * integral[dX / (-r_A)] simplifies for constant-density systems to space time tau = C_A0 * integral[dX / (-r_A)], which is mathematically identical to the batch reactor reaction time equation.

For gas-phase reactions with a change in total moles, volumetric expansion must be rigorously accounted for using v = v_0 * (1 + epsilon * X) * (P_0 / P) * (T / T_0), where expansion factor epsilon = y_A0 * delta.

For all standard positive-order reactions (n > 0), an ideal PFR requires a smaller volume than a single CSTR (V_PFR < V_CSTR) to achieve the same conversion because the PFR operates at higher intermediate reactant concentrations along its length.

Autocatalytic reactions (A + P -> 2P) and product-inhibited reactions exhibit an internal rate maximum where 1/(-r_A) reaches a minimum, making an initial CSTR followed by a downstream PFR the optimal reactor combination to minimize total volume.

A Recycle Plug Flow Reactor with recycle ratio R = v_recycle / v_product provides continuous interpolation between an ideal PFR (R = 0) and an ideal CSTR (R -> infinity), enabling temperature control, autocatalytic seeding, or boundary layer shear control.

Last updated: September 2026

13.4 Plug Flow Reactors (PFR) and Reactor Combinations

Unlike a continuous stirred-tank reactor, where fluid is instantaneously backmixed, an Ideal Plug Flow Reactor (PFR) —also termed a tubular reactor or piston-flow reactor —operates with zero axial mixing. Fluid elements pass through the vessel in an orderly, plug-like manner, each having an identical residence time.

On the NCEES PE Chemical Exam , tubular reactor design requires integrating rate equations along the reactor length, properly accounting for gas-phase expansion or contraction ( ε \varepsilon ε ), comparing PFR versus CSTR volume requirements on Levenspiel plots , and selecting optimal configurations (such as CSTR-PFR combinations or recycle loops) for specialized reaction kinetics.

1. Ideal Plug Flow Reactor (PFR) Design Equations

Consider an ideal tubular reactor with fluid flowing continuously at steady state in the axial direction z z z . Ideal Plug Flow Reactor (PFR)

  • ----------------------------
  • Feed In Product Out
  • (F_A0, v_0) +---------------------------------------+ (F_A, v, X)
  • ------------>| ===> ===> [ dV ] ===> ===> ==>|---------------->
  • +---------------------------------------+
  • 0 V V_total
  • Differential Slice dV
  • Molar Flow: F_A ---> F_A + dF_A
  • Conversion: X ---> X + dX

The Ideal PFR Assumptions:

Zero Axial Dispersion ( D z = 0 D_z = 0 D z ​ = 0 ): There is no backmixing or diffusion of fluid elements in the axial direction of flow. Fluid elements do not overtake or mix with elements ahead or behind them.

Complete Radial Homogeneity ( D r → ∞ D_r \to \infty D r ​ → ∞ ): Fluid velocity, temperature, and species concentrations are perfectly uniform across any cross-sectional slice perpendicular to flow.

Uniform Residence Time: Every fluid packet spends the exact same duration traversing the reactor from inlet to outlet.

Derivation of the PFR Mole Balance

Performing a steady-state mole balance on species A A A across a differential volume element Δ V \Delta V Δ V : F A ∣ V − F A ∣ V + Δ V + r A Δ V = 0 \left. F_A \right|_V - \left. F_A \right|_{V + \Delta V} + r_A \Delta V = 0 F A ​ ∣ V ​ − F A ​ ∣ V + Δ V ​ + r A ​ Δ V = 0

Dividing by Δ V \Delta V Δ V and taking the limit as Δ V → 0 \Delta V \to 0 Δ V → 0 : − d F A d V = − r A -\frac{dF_A}{dV} = -r_A − d V d F A ​ ​ = − r A ​

Expressing molar flow in terms of conversion ( F A = F A 0 ( 1 − X ) ⟹ d F A = − F A 0 d X F_A = F_{A0}(1 - X) \implies dF_A = -F_{A0} dX F A ​ = F A 0 ​ ( 1 − X ) ⟹ d F A ​ = − F A 0 ​ d X ): F A 0 d X d V = − r A ⟹ d X d V = − r A F A 0 F_{A0} \frac{dX}{dV} = -r_A \implies \frac{dX}{dV} = \frac{-r_A}{F_{A0}} F A 0 ​ d V d X ​ = − r A ​ ⟹ d V d X ​ = F A 0 ​ − r A ​ ​

Separating variables and integrating across the reactor from V = 0 V = 0 V = 0 ( X = 0 X = 0 X = 0 ) to total volume V V V ( X X X ): V = F A 0 ∫ 0 X d X − r A V = F_{A0} \int_0^X \frac{dX}{-r_A} V = F A 0 ​ ∫ 0 X ​ − r A ​ d X ​

For constant volumetric flow rate ( v = v 0 v = v_0 v = v 0 ​ , constant fluid density), noting F A 0 = v 0 C A 0 F_{A0} = v_0 C_{A0} F A 0 ​ = v 0 ​ C A 0 ​ : τ = V v 0 = C A 0 ∫ 0 X d X − r A = − ∫ C A 0 C A d C A − r A \tau = \frac{V}{v_0} = C_{A0} \int_0^X \frac{dX}{-r_A} = -\int_{C_{A0}}^{C_A} \frac{dC_A}{-r_A} τ = v 0 ​ V ​ = C A 0 ​ ∫ 0 X ​ − r A ​ d X ​ = − ∫ C A 0 ​ C A ​ ​ − r A ​ d C A ​ ​

Note

Equivalence of Constant-Density PFR and Batch Reactor:

For constant-density systems, the space time equation for an ideal PFR ( τ P F R = C A 0 ∫ 0 X d X − r A \tau_{PFR} = C_{A0} \int_0^X \frac{dX}{-r_A} τ PFR ​ = C A 0 ​ ∫ 0 X ​ − r A ​ d X ​ ) is mathematically identical to the reaction time equation of an ideal batch reactor ( t b a t c h = C A 0 ∫ 0 X d X − r A t_{batch} = C_{A0} \int_0^X \frac{dX}{-r_A} t ba t c h ​ = C A 0 ​ ∫ 0 X ​ − r A ​ d X ​ ). An ideal PFR behaves physically like a continuous chain of small batch reactors moving down a pipe.

2. Analytical Solutions for Constant-Density Tubular Reactors

When density is constant (liquid-phase reactions or gas reactions with no change in moles, temperature, or pressure):

Zero-Order Reaction ( − r A = k -r_A = k − r A ​ = k ): τ = C A 0 ∫ 0 X d X k = C A 0 X k ⟹ X = k τ C A 0 \tau = C_{A0} \int_0^X \frac{dX}{k} = \frac{C_{A0} X}{k} \implies X = \frac{k \tau}{C_{A0}} τ = C A 0 ​ ∫ 0 X ​ k d X ​ = k C A 0 ​ X ​ ⟹ X = C A 0 ​ k τ ​

First-Order Reaction ( − r A = k C A = k C A 0 ( 1 − X ) -r_A = k C_A = k C_{A0}(1 - X) − r A ​ = k C A ​ = k C A 0 ​ ( 1 − X ) ): τ = C A 0 ∫ 0 X d X k C A 0 ( 1 − X ) = 1 k ln ⁡ ( 1 1 − X ) \tau = C_{A0} \int_0^X \frac{dX}{k C_{A0} (1 - X)} = \frac{1}{k} \ln\left( \frac{1}{1 - X} \right) τ = C A 0 ​ ∫ 0 X ​ k C A 0 ​ ( 1 − X ) d X ​ = k 1 ​ ln ( 1 − X 1 ​ )

Solving explicitly for conversion X X X and exit concentration C A C_A C A ​ : X = 1 − e − k τ = 1 − e − D a X = 1 - e^{-k \tau} = 1 - e^{-Da} X = 1 − e − k τ = 1 − e − D a C A = C A 0 e − k τ = C A 0 e − D a C_A = C_{A0} e^{-k \tau} = C_{A0} e^{-Da} C A ​ = C A 0 ​ e − k τ = C A 0 ​ e − D a

Second-Order Reaction ( 2 A → Products 2A \to \text{Products} 2 A → Products , − r A = k C A 2 = k C A 0 2 ( 1 − X ) 2 -r_A = k C_A^2 = k C_{A0}^2(1 - X)^2 − r A ​ = k C A 2 ​ = k C A 0 2 ​ ( 1 − X ) 2 ): τ = C A 0 ∫ 0 X d X k C A 0 2 ( 1 − X ) 2 = 1 k C A 0 ( X 1 − X ) \tau = C_{A0} \int_0^X \frac{dX}{k C_{A0}^2 (1 - X)^2} = \frac{1}{k C_{A0}} \left( \frac{X}{1 - X} \right) τ = C A 0 ​ ∫ 0 X ​ k C A 0 2 ​ ( 1 − X ) 2 d X ​ = k C A 0 ​ 1 ​ ( 1 − X X ​ ) X = k C A 0 τ 1 + k C A 0 τ = D a 1 + D a X = \frac{k C_{A0} \tau}{1 + k C_{A0} \tau} = \frac{Da}{1 + Da} X = 1 + k C A 0 ​ τ k C A 0 ​ τ ​ = 1 + D a D a ​

3. Variable-Density Gas-Phase Systems and Expansion Factor ( ε \varepsilon ε )

In gas-phase reactions where the total number of moles changes (e.g., A → 2 B A \to 2B A → 2 B ), the volumetric flow rate changes continuously as the reaction proceeds down the tube. Sizing the reactor assuming constant volumetric flow introduces massive design errors.

Equation of State and Volumetric Flow Rate

For ideal gases, volumetric flow rate v v v at any point in the reactor is related to molar flow by v = F T ( R T P ) v = F_T \left(\frac{R T}{P}\right) v = F T ​ ( P RT ​ ) : v = v 0 ( 1 + ε X ) ( P 0 P ) ( T T 0 ) v = v_0 (1 + \varepsilon X) \left( \frac{P_0}{P} \right) \left( \frac{T}{T_0} \right) v = v 0 ​ ( 1 + εX ) ( P P 0 ​ ​ ) ( T 0 ​ T ​ )

Where:

v 0 v_0 v 0 ​ = entering volumetric flow rate.

P 0 , T 0 P_0, T_0 P 0 ​ , T 0 ​ = entering pressure and temperature.

P , T P, T P , T = local pressure and temperature.

ε \varepsilon ε = fractional change in total volume between zero conversion and complete conversion ( X = 1.0 X = 1.0 X = 1.0 ).

Calculation of the Expansion Factor ( ε \varepsilon ε )

For a reaction a A + b B ⟶ c C + d D a A + b B \longrightarrow c C + d D a A + b B ⟶ c C + d D , the stoichiometric change in moles per mole of A A A reacted is: δ = d + c − b − a a \delta = \frac{d + c - b - a}{a} δ = a d + c − b − a ​

If the feed contains mole fraction y A 0 y_{A0} y A 0 ​ of reactant A A A (with the balance being inerts or non-limiting reactants): ε = y A 0 ⋅ δ = y A 0 ( d + c − b − a a ) = V X = 1 − V X = 0 V X = 0 \varepsilon = y_{A0} \cdot \delta = y_{A0} \left( \frac{d + c - b - a}{a} \right) = \frac{V_{X=1} - V_{X=0}}{V_{X=0}} ε = y A 0 ​ ⋅ δ = y A 0 ​ ( a d + c − b − a ​ ) = V X = 0 ​ V X = 1 ​ − V X = 0 ​ ​

Reactant Concentration Under Variable Volume

Under isothermal ( T = T 0 T = T_0 T = T 0 ​ ) and isobaric ( P = P 0 P = P_0 P = P 0 ​ ) conditions: C A = F A v = F A 0 ( 1 − X ) v 0 ( 1 + ε X ) = C A 0 ( 1 − X 1 + ε X ) C_A = \frac{F_A}{v} = \frac{F_{A0} (1 - X)}{v_0 (1 + \varepsilon X)} = C_{A0} \left( \frac{1 - X}{1 + \varepsilon X} \right) C A ​ = v F A ​ ​ = v 0 ​ ( 1 + εX ) F A 0 ​ ( 1 − X ) ​ = C A 0 ​ ( 1 + εX 1 − X ​ )

Design Equation for First-Order Gas Reaction with Expansion

Substituting C A C_A C A ​ into the PFR design integral: V = F A 0 ∫ 0 X d X k C A = F A 0 k C A 0 ∫ 0 X ( 1 + ε X 1 − X ) d X = v 0 k ∫ 0 X ( 1 + ε X 1 − X ) d X V = F_{A0} \int_0^X \frac{dX}{k C_A} = \frac{F_{A0}}{k C_{A0}} \int_0^X \left( \frac{1 + \varepsilon X}{1 - X} \right) dX = \frac{v_0}{k} \int_0^X \left( \frac{1 + \varepsilon X}{1 - X} \right) dX V = F A 0 ​ ∫ 0 X ​ k C A ​ d X ​ = k C A 0 ​ F A 0 ​ ​ ∫ 0 X ​ ( 1 − X 1 + εX ​ ) d X = k v 0 ​ ​ ∫ 0 X ​ ( 1 − X 1 + εX ​ ) d X

Using the algebraic identity 1 + ε X 1 − X = ( 1 + ε ) − ε ( 1 − X ) 1 − X = 1 + ε 1 − X − ε \frac{1 + \varepsilon X}{1 - X} = \frac{(1 + \varepsilon) - \varepsilon(1 - X)}{1 - X} = \frac{1 + \varepsilon}{1 - X} - \varepsilon 1 − X 1 + εX ​ = 1 − X ( 1 + ε ) − ε ( 1 − X ) ​ = 1 − X 1 + ε ​ − ε : V = v 0 k [ ( 1 + ε ) ln ⁡ ( 1 1 − X ) − ε X ] V = \frac{v_0}{k} \left[ (1 + \varepsilon) \ln\left( \frac{1}{1 - X} \right) - \varepsilon X \right] V = k v 0 ​ ​ [ ( 1 + ε ) ln ( 1 − X 1 ​ ) − εX ] Physical Impact of Expansion Factor (epsilon):

---------------------------------------------------------------------------

epsilon > 0 (Expansion, e.g. A -> 2B):

Volume increases with X -> Gas velocity increases -> Residence time drops

Requires LARGER reactor volume than constant-density prediction.

epsilon < 0 (Contraction, e.g. 2A -> B):

Volume decreases with X -> Gas velocity slows -> Residence time rises

Requires SMALLER reactor volume than constant-density prediction.

4. Performance Comparison: CSTR vs. PFR and Levenspiel Plot Analysis

A cornerstone of reaction engineering is comparing the volume required for a CSTR versus a PFR to achieve the exact same conversion under identical feed and temperature conditions. Levenspiel Plot: (1 / -r_A) versus Conversion (X)

  • 1 / (-r_A)
  • ^
  • | / (1 / -r_A) Curve (for normal order n > 0)
  • | /
  • | *-------------------+
  • | /| | CSTR Volume = F_A0 * [X / (-r_A)_exit]
  • | / | | (Area of full RECTANGLE)
  • | / | PFR Volume = |
  • | / | F_A0 * INT(dX/-r_A)
  • | / | (Area UNDER |
  • | / | the curve) |
  • +------------*------+-------------------+-----> Conversion (X)
  • 0 X_exit X_exit

Graphical Analysis on a Levenspiel Plot:

PFR Volume: Equals F A 0 F_{A0} F A 0 ​ multiplied by the area under the curve of 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) from 0 0 0 to X X X .

CSTR Volume: Equals F A 0 F_{A0} F A 0 ​ multiplied by the area of the rectangle of height 1 / ( − r A ) e x i t 1/(-r_A)_{exit} 1/ ( − r A ​ ) e x i t ​ and width X X X .

For Normal Reaction Orders ( n > 0 n > 0 n > 0 ):

For any reaction where rate increases with reactant concentration (all orders n > 0 n > 0 n > 0 ), the reaction rate is highest at the inlet and decreases continuously as conversion rises.

In a PFR, the fluid experiences high rates throughout the beginning and middle of the reactor.

In a CSTR, the entire reactor operates at the lowest rate, ( − r A ) e x i t (-r_A)_{exit} ( − r A ​ ) e x i t ​ .

Therefore, for all positive reaction orders: V C S T R > V P F R ( for n > 0 ) V_{CSTR} > V_{PFR} \quad (\text{for } n > 0) V CSTR ​ > V PFR ​ ( for n > 0 )

The ratio V C S T R / V P F R V_{CSTR} / V_{PFR} V CSTR ​ / V PFR ​ expands rapidly as conversion increases:

Conversion ( X X X ) First-Order Volume Ratio ( V C S T R / V P F R V_{CSTR} / V_{PFR} V CSTR ​ / V PFR ​ ) Second-Order Volume Ratio ( V C S T R / V P F R V_{CSTR} / V_{PFR} V CSTR ​ / V PFR ​ )

  • 0.50 0.50 0.50 (50%) 1.44 1.44 1.44 2.00 2.00 2.00
  • 0.80 0.80 0.80 (80%) 2.49 2.49 2.49 5.00 5.00 5.00
  • 0.90 0.90 0.90 (90%) 3.91 3.91 3.91 10.0 10.0 10.0
  • 0.99 0.99 0.99 (99%) 21.5 21.5 21.5 100.0 100.0 100.0

At 99 % 99\% 99% conversion for a second-order reaction, a single CSTR must be 100 times larger than an equivalent PFR!

5. Autocatalytic Reactions and Optimal Reactor Sequencing

While V C S T R > V P F R V_{CSTR} > V_{PFR} V CSTR ​ > V PFR ​ holds for normal kinetics, an important exception occurs for autocatalytic reactions , where a reaction product acts as a catalyst: A + P ⟶ P + P A + P \longrightarrow P + P A + P ⟶ P + P − r A = k C A C P = k C A 0 2 ( 1 − X ) ( θ P + X ) -r_A = k C_A C_P = k C_{A0}^2 (1 - X) (\theta_P + X) − r A ​ = k C A ​ C P ​ = k C A 0 2 ​ ( 1 − X ) ( θ P ​ + X )

Where θ P = C P 0 / C A 0 \theta_P = C_{P0} / C_{A0} θ P ​ = C P 0 ​ / C A 0 ​ is the ratio of product to reactant in the entering feed. Autocatalytic Levenspiel Curve & Optimal Sequencing:

  • 1 / (-r_A)
  • ^
  • | \ (High 1/-r_A at inlet due to low CP0)
  • | \
  • | \ CSTR Area PFR Area
  • | \ [Rectangle] [Under Curve]
  • | \+----------------+ /
  • | | | /
  • | | CSTR operates |/
  • | +----------------* (MINIMUM: Maximum Rate)
  • | |\
  • | | \
  • +------------------------+--+------------------> X
  • 0 X_opt X_final

The Autocatalytic Rate Profile:

At X = 0 X = 0 X = 0 , C P C_P C P ​ is near zero, so the rate is extremely slow ( 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) is very large).

As product P P P forms, the rate accelerates, reaching a maximum where d ( − r A ) d X = 0 \frac{d(-r_A)}{dX} = 0 d X d ( − r A ​ ) ​ = 0 (at X o p t = 1 − θ P 2 ≈ 0.50 X_{opt} = \frac{1 - \theta_P}{2} \approx 0.50 X o pt ​ = 2 1 − θ P ​ ​ ≈ 0.50 ). At this point, 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) reaches a minimum .

Beyond X o p t X_{opt} X o pt ​ , reactant A A A is depleted, causing the rate to decline and 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) to rise again.

Optimal Reactor Configuration:

First Stage (CSTR): From X = 0 X = 0 X = 0 to X o p t X_{opt} X o pt ​ , use a CSTR operating at the point of maximum reaction rate. On the Levenspiel plot, the CSTR rectangle operating at the minimum of 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) is far smaller than the huge area under the curve of a PFR.

Second Stage (PFR): From X o p t X_{opt} X o pt ​ to final high conversion X f i n a l X_{final} X f ina l ​ , use a PFR. In this region, rate decreases with conversion, so the area under the curve is much smaller than a second CSTR rectangle.

Tip

Rule for Optimal Sequencing:

Whenever the Levenspiel curve ( 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) vs. X X X ) has a negative slope ( d ( − r A ) / d X > 0 d(-r_A)/dX > 0 d ( − r A ​ ) / d X > 0 , rate increases with conversion), a CSTR is superior. Whenever the curve has a positive slope ( d ( − r A ) / d X < 0 d(-r_A)/dX < 0 d ( − r A ​ ) / d X < 0 , rate decreases with conversion), a PFR is superior.

6. Recycle Plug Flow Reactors

A Recycle PFR recycles a portion of the product stream leaving the tubular reactor back to the inlet. Recycle Plug Flow Reactor

  • ------------------------
  • Recycle Stream (R * v_exit, X_exit)
  • +-----------------------------------+
  • | |
  • v_0, C_A0 v | v_exit, C_A,exit
  • ----------->(+)---> [ PFR: Volume V ] ---------->+----> (1 - X_exit)
  • Mix Inlet to PFR: X_in' Split
  • The Recycle Ratio ( R R R )

The recycle ratio ( R R R ) is defined as the volumetric flow rate returned to the reactor divided by the net volumetric flow rate leaving the system: R ≡ v r e c y c l e v e x i t R \equiv \frac{v_{recycle}}{v_{exit}} R ≡ v e x i t ​ v recyc l e ​ ​

Conversion Entering the Reactor ( X i n ′ X_{in}' X in ′ ​ )

Molecular mixing at the inlet tee combines fresh feed ( X = 0 X = 0 X = 0 ) with recycle fluid ( X = X e x i t X = X_{exit} X = X e x i t ​ ): X i n ′ = R R + 1 X e x i t X_{in}' = \frac{R}{R + 1} X_{exit} X in ′ ​ = R + 1 R ​ X e x i t ​

Design Equation for a Recycle PFR

Integrating the tubular reactor balance from X i n ′ X_{in}' X in ′ ​ to X e x i t X_{exit} X e x i t ​ : V = F A 0 ( R + 1 ) ∫ R R + 1 X e x i t X e x i t d X − r A V = F_{A0} (R + 1) \int_{\frac{R}{R+1} X_{exit}}^{X_{exit}} \frac{dX}{-r_A} V = F A 0 ​ ( R + 1 ) ∫ R + 1 R ​ X e x i t ​ X e x i t ​ ​ − r A ​ d X ​

Limiting Behaviors of the Recycle Reactor:

No Recycle ( R = 0 R = 0 R = 0 ): X i n ′ = 0 X_{in}' = 0 X in ′ ​ = 0 , and ( R + 1 ) = 1 (R + 1) = 1 ( R + 1 ) = 1 . The equation collapses to an ideal PFR : V = F A 0 ∫ 0 X e x i t d X − r A V = F_{A0} \int_0^{X_{exit}} \frac{dX}{-r_A} V = F A 0 ​ ∫ 0 X e x i t ​ ​ − r A ​ d X ​

Infinite Recycle ( R → ∞ R \to \infty R → ∞ ): The fluid recirculates so rapidly that concentration gradients vanish. The equation converges identically to an ideal CSTR : lim ⁡ R → ∞ V = F A 0 X e x i t ( − r A ) e x i t \lim_{R \to \infty} V = \frac{F_{A0} X_{exit}}{(-r_A)_{exit}} R → ∞ lim ​ V = ( − r A ​ ) e x i t ​ F A 0 ​ X e x i t ​ ​

Industrial Uses of Recycle Reactors:

Autocatalytic seeding: Returns product P P P to the feed to eliminate the slow induction period.

Exothermic heat management: Recycled fluid dilutes the inlet reactant concentration and absorbs heat, moderating temperature spikes.

Catalytic boundary layer control: Maintains high superficial fluid velocities through fixed catalyst beds to minimize external film mass transfer resistance without requiring large external fresh feeds.

7. Summary Comparison Table: PFR, CSTR, and Recycle Reactor Performance

Feature Ideal PFR ( R = 0 R = 0 R = 0 ) Ideal CSTR ( R → ∞ R \to \infty R → ∞ ) Recycle PFR ( 0 < R < ∞ 0 < R < \infty 0 < R < ∞ )

Mixing State Zero backmixing ( D z = 0 D_z = 0 D z ​ = 0 ) Infinite backmixing ( D z → ∞ D_z \to \infty D z ​ → ∞ ) Adjustable intermediate mixing

Exit Concentration C A = C A 0 e − k τ C_A = C_{A0} e^{-k \tau} C A ​ = C A 0 ​ e − k τ (1st order) C A = C A 0 1 + k τ C_A = \frac{C_{A0}}{1 + k \tau} C A ​ = 1 + k τ C A 0 ​ ​ (1st order) Intermediate between PFR and CSTR

Relative Size ( n > 0 n > 0 n > 0 ) Smallest required volume Largest required volume Intermediate volume

Volume with Expansion ( ε > 0 \varepsilon > 0 ε > 0 ) V = v 0 k [ ( 1 + ε ) ln ⁡ 1 1 − X − ε X ] V = \frac{v_0}{k}[(1+\varepsilon)\ln\frac{1}{1-X} - \varepsilon X] V = k v 0 ​ ​ [( 1 + ε ) ln 1 − X 1 ​ − εX ] V = v 0 X k ( 1 − X ) ( 1 + ε X ) V = \frac{v_0 X}{k (1 - X)} (1 + \varepsilon X) V = k ( 1 − X ) v 0 ​ X ​ ( 1 + εX ) Intermediate numerical integral

Thermal Behavior Hot spots possible in exothermic reactions Uniform, easily controlled temperature Recycle absorbs heat, dampens hot spots

Best Operating Kinetic Regime Normal orders ( n > 0 n > 0 n > 0 ), high conversion Autocatalytic at low X X X , high heat release Autocatalytic, high-heat reactions

  • 8. Step-by-Step Worked Numerical Example: Gas-Phase Cracking Reactor Design with Expansion
  • Problem Statement

An industrial gaseous hydrocarbon A A A is thermally cracked according to the stoichiometry: A ( g ) ⟶ 2 B ( g ) + C ( g ) A_{(g)} \longrightarrow 2 B_{(g)} + C_{(g)} A ( g ) ​ ⟶ 2 B ( g ) ​ + C ( g ) ​

The reaction is elementary first order with rate constant k = 0.250 s − 1 k = 0.250\text{ s}^{-1} k = 0.250 s − 1 at 700 K 700\text{ K} 700 K and 4.00 atm 4.00\text{ atm} 4.00 atm . The feed consists of pure A A A ( y A 0 = 1.00 y_{A0} = 1.00 y A 0 ​ = 1.00 ) entering at F A 0 = 40.0 mol/s F_{A0} = 40.0\text{ mol/s} F A 0 ​ = 40.0 mol/s . The target conversion is 80.0 % 80.0\% 80.0% ( X = 0.800 X = 0.800 X = 0.800 ). The reactor operates isothermally and isobarically.

Calculate:

The expansion factor ε \varepsilon ε .

The entering volumetric flow rate v 0 v_0 v 0 ​ in m 3 /s \text{m}^3\text{/s} m 3 /s and entering concentration C A 0 C_{A0} C A 0 ​ in mol/m 3 \text{mol/m}^3 mol/m 3 .

The required PFR volume ( V P F R V_{PFR} V PFR ​ ) accounting for gas expansion.

The PFR volume that would be calculated if the engineer erroneously assumed constant density ( ε = 0 \varepsilon = 0 ε = 0 ), and the resulting percentage under-sizing error.

The required volume for a single CSTR ( V C S T R V_{CSTR} V CSTR ​ ) under identical operating conditions, and the volume ratio V C S T R / V P F R V_{CSTR} / V_{PFR} V CSTR ​ / V PFR ​ .

Step 1: Calculate the Expansion Factor ( ε \varepsilon ε )

Stoichiometry: 1 A → 2 B + 1 C 1 A \to 2 B + 1 C 1 A → 2 B + 1 C . δ = ∑ ν p r o d u c t s − ∑ ν r e a c t a n t s ν A = ( 2 + 1 ) − 1 1 = 3 − 1 1 = + 2.00 \delta = \frac{\sum \nu_{products} - \sum \nu_{reactants}}{\nu_A} = \frac{(2 + 1) - 1}{1} = \frac{3 - 1}{1} = +2.00 δ = ν A ​ ∑ ν p ro d u c t s ​ − ∑ ν re a c t an t s ​ ​ = 1 ( 2 + 1 ) − 1 ​ = 1 3 − 1 ​ = + 2.00

Because the feed is pure A A A ( y A 0 = 1.00 y_{A0} = 1.00 y A 0 ​ = 1.00 ): ε = y A 0 ⋅ δ = 1.00 × ( + 2.00 ) = + 2.00 \varepsilon = y_{A0} \cdot \delta = 1.00 \times (+2.00) = \mathbf{+2.00} ε = y A 0 ​ ⋅ δ = 1.00 × ( + 2.00 ) = + 2.00

Every mole of A A A converted produces three moles of product gas, resulting in a 200 % 200\% 200% increase in total gas volume at complete conversion.

Step 2: Calculate Entering Concentration and Volumetric Flow Rate

Using the ideal gas law with R = 8.2057 × 10 − 5 m 3 ⋅ atm / ( mol ⋅ K ) R = 8.2057\times 10^{-5}\text{ m}^3\cdot\text{atm}/(\text{mol}\cdot\text{K}) R = 8.2057 × 1 0 − 5 m 3 ⋅ atm / ( mol ⋅ K ) : C A 0 = P 0 R T 0 = 4.00 atm ( 8.2057 × 10 − 5 m 3 ⋅ atm / ( mol ⋅ K ) ) × 700 K = 4.00 0.057440 = 69.638 mol/m 3 ( 0.06964 mol/L ) C_{A0} = \frac{P_0}{R T_0} = \frac{4.00\text{ atm}}{(8.2057\times 10^{-5}\text{ m}^3\cdot\text{atm}/(\text{mol}\cdot\text{K})) \times 700\text{ K}} = \frac{4.00}{0.057440} = \mathbf{69.638\text{ mol/m}^3} \quad (0.06964\text{ mol/L}) C A 0 ​ = R T 0 ​ P 0 ​ ​ = ( 8.2057 × 1 0 − 5 m 3 ⋅ atm / ( mol ⋅ K )) × 700 K 4.00 atm ​ = 0.057440 4.00 ​ = 69.638 mol/m 3 ( 0.06964 mol/L ) v 0 = F A 0 C A 0 = 40.0 mol/s 69.638 mol/m 3 = 0.57440 m 3 /s ( 574.4 L/s ) v_0 = \frac{F_{A0}}{C_{A0}} = \frac{40.0\text{ mol/s}}{69.638\text{ mol/m}^3} = \mathbf{0.57440\text{ m}^3\text{/s}} \quad (574.4\text{ L/s}) v 0 ​ = C A 0 ​ F A 0 ​ ​ = 69.638 mol/m 3 40.0 mol/s ​ = 0.57440 m 3 /s ( 574.4 L/s )

Step 3: Calculate PFR Volume with Gas Expansion

Applying the analytical first-order variable-volume PFR equation: V P F R = v 0 k [ ( 1 + ε ) ln ⁡ ( 1 1 − X ) − ε X ] V_{PFR} = \frac{v_0}{k} \left[ (1 + \varepsilon) \ln\left( \frac{1}{1 - X} \right) - \varepsilon X \right] V PFR ​ = k v 0 ​ ​ [ ( 1 + ε ) ln ( 1 − X 1 ​ ) − εX ]

Evaluate each term for ε = 2.00 \varepsilon = 2.00 ε = 2.00 and X = 0.800 X = 0.800 X = 0.800 : 1 + ε = 1 + 2.00 = 3.00 1 + \varepsilon = 1 + 2.00 = 3.00 1 + ε = 1 + 2.00 = 3.00 ln ⁡ ( 1 1 − 0.800 ) = ln ⁡ ( 5.00 ) = 1.60944 \ln\left( \frac{1}{1 - 0.800} \right) = \ln(5.00) = 1.60944 ln ( 1 − 0.800 1 ​ ) = ln ( 5.00 ) = 1.60944 ( 1 + ε ) ln ⁡ ( 1 1 − X ) = 3.00 × 1.60944 = 4.82831 (1 + \varepsilon) \ln\left( \frac{1}{1 - X} \right) = 3.00 \times 1.60944 = 4.82831 ( 1 + ε ) ln ( 1 − X 1 ​ ) = 3.00 × 1.60944 = 4.82831 ε X = 2.00 × 0.800 = 1.60000 \varepsilon X = 2.00 \times 0.800 = 1.60000 εX = 2.00 × 0.800 = 1.60000 Integral Bracket = 4.82831 − 1.60000 = 3.22831 \text{Integral Bracket} = 4.82831 - 1.60000 = 3.22831 Integral Bracket = 4.82831 − 1.60000 = 3.22831

Now calculate volume: V P F R = 0.57440 m 3 /s 0.250 s − 1 × 3.22831 = 2.2976 m 3 × 3.22831 = 7.417 m 3 ( 7 , ⁣ 417 L ) V_{PFR} = \frac{0.57440\text{ m}^3\text{/s}}{0.250\text{ s}^{-1}} \times 3.22831 = 2.2976\text{ m}^3 \times 3.22831 = \mathbf{7.417\text{ m}^3} \quad (7,\!417\text{ L}) V PFR ​ = 0.250 s − 1 0.57440 m 3 /s ​ × 3.22831 = 2.2976 m 3 × 3.22831 = 7.417 m 3 ( 7 , 417 L )

Step 4: Compare with Constant-Density PFR Sizing

If expansion were ignored ( ε = 0 \varepsilon = 0 ε = 0 ): V ε = 0 = v 0 k ln ⁡ ( 1 1 − X ) = 0.57440 0.250 × 1.60944 = 2.2976 × 1.60944 = 3.698 m 3 V_{\varepsilon=0} = \frac{v_0}{k} \ln\left( \frac{1}{1 - X} \right) = \frac{0.57440}{0.250} \times 1.60944 = 2.2976 \times 1.60944 = \mathbf{3.698\text{ m}^3} V ε = 0 ​ = k v 0 ​ ​ ln ( 1 − X 1 ​ ) = 0.250 0.57440 ​ × 1.60944 = 2.2976 × 1.60944 = 3.698 m 3

Under-sizing error: Error = V P F R − V ε = 0 V P F R × 100 % = 7.417 − 3.698 7.417 × 100 % = 50.1 % \text{Error} = \frac{V_{PFR} - V_{\varepsilon=0}}{V_{PFR}} \times 100\% = \frac{7.417 - 3.698}{7.417} \times 100\% = \mathbf{50.1\%} Error = V PFR ​ V PFR ​ − V ε = 0 ​ ​ × 100% = 7.417 7.417 − 3.698 ​ × 100% = 50.1%

Neglecting gas expansion cuts the required reactor volume in half! The actual reactor would achieve far less than 80 % 80\% 80% conversion because the expanding gas accelerates through the tube, drastically cutting residence time.

Step 5: Calculate Single CSTR Volume and Volume Ratio

For a CSTR with variable volume, the exit concentration is: C A , e x i t = C A 0 ( 1 − X 1 + ε X ) = 69.638 × ( 1 − 0.800 1 + 2.00 ( 0.800 ) ) = 69.638 × ( 0.200 2.600 ) = 5.3568 mol/m 3 C_{A,exit} = C_{A0} \left( \frac{1 - X}{1 + \varepsilon X} \right) = 69.638 \times \left( \frac{1 - 0.800}{1 + 2.00(0.800)} \right) = 69.638 \times \left( \frac{0.200}{2.600} \right) = 5.3568\text{ mol/m}^3 C A , e x i t ​ = C A 0 ​ ( 1 + εX 1 − X ​ ) = 69.638 × ( 1 + 2.00 ( 0.800 ) 1 − 0.800 ​ ) = 69.638 × ( 2.600 0.200 ​ ) = 5.3568 mol/m 3 ( − r A ) e x i t = k C A , e x i t = 0.250 s − 1 × 5.3568 mol/m 3 = 1.3392 mol / ( m 3 ⋅ s ) (-r_A)_{exit} = k C_{A,exit} = 0.250\text{ s}^{-1} \times 5.3568\text{ mol/m}^3 = 1.3392\text{ mol}/(\text{m}^3\cdot\text{s}) ( − r A ​ ) e x i t ​ = k C A , e x i t ​ = 0.250 s − 1 × 5.3568 mol/m 3 = 1.3392 mol / ( m 3 ⋅ s )

CSTR volume: V C S T R = F A 0 X ( − r A ) e x i t = 40.0 mol/s × 0.800 1.3392 mol / ( m 3 ⋅ s ) = 32.0 1.3392 = 23.895 m 3 ( 23 , ⁣ 895 L ) V_{CSTR} = \frac{F_{A0} X}{(-r_A)_{exit}} = \frac{40.0\text{ mol/s} \times 0.800}{1.3392\text{ mol}/(\text{m}^3\cdot\text{s})} = \frac{32.0}{1.3392} = \mathbf{23.895\text{ m}^3} \quad (23,\!895\text{ L}) V CSTR ​ = ( − r A ​ ) e x i t ​ F A 0 ​ X ​ = 1.3392 mol / ( m 3 ⋅ s ) 40.0 mol/s × 0.800 ​ = 1.3392 32.0 ​ = 23.895 m 3 ( 23 , 895 L )

Volume comparison ratio: V C S T R V P F R = 23.895 m 3 7.417 m 3 = 3.22 \frac{V_{CSTR}}{V_{PFR}} = \frac{23.895\text{ m}^3}{7.417\text{ m}^3} = \mathbf{3.22} V PFR ​ V CSTR ​ ​ = 7.417 m 3 23.895 m 3 ​ = 3.22

The CSTR must be 3.22 3.22 3.22 times larger than the PFR to deliver the same conversion.

  • 9. Critical PE Exam Traps & Pitfalls
  • Trap 1: Omitting Inerts when Computing ε \varepsilon ε

Remember ε = y A 0 δ \varepsilon = y_{A0} \delta ε = y A 0 ​ δ . If feed contains 40 % 40\% 40% reactant A A A and 60 % 60\% 60% nitrogen diluent, and δ = + 2 \delta = +2 δ = + 2 , then ε = 0.40 × 2 = + 0.80 \varepsilon = 0.40 \times 2 = +0.80 ε = 0.40 × 2 = + 0.80 , NOT + 2.0 +2.0 + 2.0 . Inerts do not react, so they dampen the overall fractional expansion of the gas stream.

Trap 2: Using the Constant-Density Integral for Gas Reactions

On tubular gas reactor problems, immediately check if moles change: ∑ ν p r o d u c t s ≠ ∑ ν r e a c t a n t s \sum \nu_{products} \neq \sum \nu_{reactants} ∑ ν p ro d u c t s ​  = ∑ ν re a c t an t s ​ . If moles change, you cannot use τ = ( 1 / k ) ln ⁡ [ 1 / ( 1 − X ) ] \tau = (1/k)\ln[1/(1-X)] τ = ( 1/ k ) ln [ 1/ ( 1 − X )] . You must use the integrated form containing ( 1 + ε ) ln ⁡ [ 1 / ( 1 − X ) ] − ε X (1 + \varepsilon) \ln[1/(1-X)] - \varepsilon X ( 1 + ε ) ln [ 1/ ( 1 − X )] − εX .

Trap 3: Claiming PFR is Always Smaller Than CSTR

While true for orders n > 0 n > 0 n > 0 , this is false for autocatalytic kinetics ( A + P → 2 P A + P \to 2P A + P → 2 P ) or reactions with product inhibition. At low conversions, 1 / ( − r A ) 1/(-r_A) 1/ ( − r A ​ ) decreases with conversion, so a CSTR requires less volume than a PFR. Be alert for autocatalytic kinetics on the PE exam!

Trap 4: Inverting the Recycle Inlet Conversion Formula

In recycle reactors, the mixed feed conversion entering the reactor is X i n ′ = R R + 1 X e x i t X_{in}' = \frac{R}{R+1} X_{exit} X in ′ ​ = R + 1 R ​ X e x i t ​ . A common algebra error is writing X i n ′ = 1 R + 1 X e x i t X_{in}' = \frac{1}{R+1} X_{exit} X in ′ ​ = R + 1 1 ​ X e x i t ​ . When R = 0 R = 0 R = 0 (no recycle), X i n ′ X_{in}' X in ′ ​ must equal 0 0 0 .