Study guide
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes
Key Takeaways Explain This Topic AI
In open steady-state flow systems, shaft work and heat interaction relate to flowing enthalpy via Q_dot - W_dot_s = ΔH_dot + ΔE_k_dot + ΔE_p_dot, where W_dot_s is positive for work delivered by the fluid to the surroundings.
For pure liquids below 30 bar, the mechanical enthalpy contribution v*ΔP is under 0.5% of total enthalpy change and is safely neglected compared to sensible heat, but it becomes vital in high-pressure boiler feed pumps.
The Watson correlation scales the latent heat of vaporization from the normal boiling point to any process temperature T: ΔH_vap(T2) = ΔH_vap(T1) * [(1 - T_r2) / (1 - T_r1)]^0.38.
Thermodynamic reference states are arbitrary datums; mixing reference states across process streams (e.g., steam tables where liquid water at 0.01°C has h = 0 vs. NIST tables where elements at 298.15 K and 1 bar have h = 0) without standardizing to a common baseline is the leading enthalpy accounting error on the PE exam.
For two-phase wet steam or vapor-liquid mixtures, specific enthalpy is strictly linear in vapor quality x: h = h_f + x * h_fg, requiring flash equilibrium validation before applying single-phase sensible heat equations.
Last updated: September 2026
Enthalpy Accounting, Sensible Heat, and Phase Changes
Energy balance calculations sit inside Mass/Energy Balances, which the NCEES PE Chemical CBT specification (effective January 1, 2020) weights at 12-18 of the 80 exam questions, with 6-9 of those drawn specifically from the Energy Balances subtopic. Mastering open-system energy conservation requires absolute clarity regarding enthalpy accounting , reference state conventions, sensible heat path integrals, and latent heat scaling.
1. Open-System First Law Formulation
For a continuous, steady-state open chemical process unit with multiple entering and exiting streams, the First Law of Thermodynamics is stated as: Q ˙ − W ˙ s = ∑ o u t m ˙ o u t ( h ^ + u 2 2 + g z ) o u t − ∑ i n m ˙ i n ( h ^ + u 2 2 + g z ) i n \dot{Q} - \dot{W}_s = \sum_{out} \dot{m}_{out} \left( \hat{h} + \frac{u^2}{2} + gz \right)_{out} - \sum_{in} \dot{m}_{in} \left( \hat{h} + \frac{u^2}{2} + gz \right)_{in} Q ˙ − W ˙ s = o u t ∑ m ˙ o u t ( h ^ + 2 u 2 + g z ) o u t − in ∑ m ˙ in ( h ^ + 2 u 2 + g z ) in
Where:
Q ˙ \dot{Q} Q ˙ = rate of heat transfer across the system boundary ( kW \text{kW} kW or Btu/h \text{Btu/h} Btu/h ), where Q ˙ > 0 \dot{Q} > 0 Q ˙ > 0 denotes heat added to the system.
W ˙ s \dot{W}_s W ˙ s = shaft work delivered by the system to the surroundings ( kW \text{kW} kW or hp \text{hp} hp ), where W ˙ s > 0 \dot{W}_s > 0 W ˙ s > 0 denotes work produced (e.g., by a turbine or expander) and W ˙ s < 0 \dot{W}_s < 0 W ˙ s < 0 denotes work consumed (e.g., by a pump or compressor).
h ^ \hat{h} h ^ = specific flowing enthalpy ( kJ/kg \text{kJ/kg} kJ/kg or Btu/lb \text{Btu/lb} Btu/lb ), defined fundamentally as h ^ = u ^ + P v ^ \hat{h} = \hat{u} + P\hat{v} h ^ = u ^ + P v ^ .
u 2 / 2 u^2 / 2 u 2 /2 = specific kinetic energy ( m 2 / s 2 = J/kg \text{m}^2/\text{s}^2 = \text{J/kg} m 2 / s 2 = J/kg ).
g z gz g z = specific potential energy ( J/kg \text{J/kg} J/kg ).
In the vast majority of chemical process units (heat exchangers, distillation columns, reboilers, condensers, reactors, and flash vessels), kinetic and potential energy variations between process inlets and outlets are negligible compared to thermal enthalpy changes ( Δ h ^ ≫ Δ e ^ k , Δ e ^ p \Delta \hat{h} \gg \Delta \hat{e}_k, \Delta \hat{e}_p Δ h ^ ≫ Δ e ^ k , Δ e ^ p ). The energy balance simplifies to: Q ˙ − W ˙ s = Δ H ˙ = ∑ o u t m ˙ o u t h ^ o u t − ∑ i n m ˙ i n h ^ i n \dot{Q} - \dot{W}_s = \Delta \dot{H} = \sum_{out} \dot{m}_{out} \hat{h}_{out} - \sum_{in} \dot{m}_{in} \hat{h}_{in} Q ˙ − W ˙ s = Δ H ˙ = o u t ∑ m ˙ o u t h ^ o u t − in ∑ m ˙ in h ^ in
When no moving shafts penetrate the control volume (e.g., heat exchangers, flash drums), W ˙ s = 0 \dot{W}_s = 0 W ˙ s = 0 , yielding Q ˙ = Δ H ˙ \dot{Q} = \Delta \dot{H} Q ˙ = Δ H ˙ .
2. Reference States and Hypothetical Process Paths
Enthalpy is a relative state function; absolute enthalpy cannot be measured. Only differences in enthalpy ( Δ h ^ \Delta \hat{h} Δ h ^ ) between defined thermodynamic states have physical meaning. To assign numerical enthalpy values to process streams, chemical engineers define an arbitrary reference state ( T r e f , P r e f , phase ) (T_{ref}, P_{ref}, \text{phase}) ( T re f , P re f , phase ) .
Hypothetical Process Path Construction
Because enthalpy is a state function independent of the actual mechanism or physical path taken, the enthalpy change between State 1 ( T 1 , P 1 , liquid ) (T_1, P_1, \text{liquid}) ( T 1 , P 1 , liquid ) and State 2 ( T 2 , P 2 , vapor ) (T_2, P_2, \text{vapor}) ( T 2 , P 2 , vapor ) is evaluated by constructing a convenient hypothetical multi-step path composed of individual steps where physical property data are readily available:
Step 1: Isothermal Pressure Change on Liquid (often neglected for liquids below 30 bar 30\text{ bar} 30 bar ): Δ h ^ 1 = ∫ P 1 P s a t ( T 1 ) [ v ^ − T ( ∂ v ^ ∂ T ) P ] d P ≈ v ^ L ( P s a t − P 1 ) \Delta \hat{h}_1 = \int_{P_1}^{P_{sat}(T_1)} \left[ \hat{v} - T \left(\frac{\partial \hat{v}}{\partial T}\right)_P \right] dP \approx \hat{v}_L (P_{sat} - P_1) Δ h ^ 1 = ∫ P 1 P s a t ( T 1 ) [ v ^ − T ( ∂ T ∂ v ^ ) P ] d P ≈ v ^ L ( P s a t − P 1 )
Step 2: Isobaric Sensible Heating of Liquid from T 1 T_1 T 1 to normal boiling point T b T_b T b : Δ h ^ 2 = ∫ T 1 T b C p , L ( T ) d T \Delta \hat{h}_2 = \int_{T_1}^{T_b} C_{p,L}(T) dT Δ h ^ 2 = ∫ T 1 T b C p , L ( T ) d T
Step 3: Isothermal, Isobaric Phase Transition (Vaporization) at T b T_b T b and P s a t ( T b ) P_{sat}(T_b) P s a t ( T b ) : Δ h ^ 3 = Δ h ^ v a p ( T b ) \Delta \hat{h}_3 = \Delta \hat{h}_{vap}(T_b) Δ h ^ 3 = Δ h ^ v a p ( T b )
Step 4: Isobaric Sensible Heating of Vapor from T b T_b T b to T 2 T_2 T 2 : Δ h ^ 4 = ∫ T b T 2 C p , V ( T ) d T \Delta \hat{h}_4 = \int_{T_b}^{T_2} C_{p,V}(T) dT Δ h ^ 4 = ∫ T b T 2 C p , V ( T ) d T
Step 5: Isothermal Pressure Change on Vapor from P s a t P_{sat} P s a t to P 2 P_2 P 2 :
For ideal gases, ( ∂ h ^ / ∂ P ) T = 0 (\partial \hat{h} / \partial P)_T = 0 ( ∂ h ^ / ∂ P ) T = 0 , so Δ h ^ 5 = 0 \Delta \hat{h}_5 = 0 Δ h ^ 5 = 0 . For real gases at high pressure, enthalpy departure functions must be incorporated.
The overall enthalpy change is the algebraic sum of all steps: Δ h ^ = Δ h ^ 1 + Δ h ^ 2 + Δ h ^ 3 + Δ h ^ 4 + Δ h ^ 5 \Delta \hat{h} = \Delta \hat{h}_1 + \Delta \hat{h}_2 + \Delta \hat{h}_3 + \Delta \hat{h}_4 + \Delta \hat{h}_5 Δ h ^ = Δ h ^ 1 + Δ h ^ 2 + Δ h ^ 3 + Δ h ^ 4 + Δ h ^ 5
3. Sensible Heat and Heat Capacity Integrations
Sensible heat refers to energy exchanged that produces a temperature change without inducing a phase transition. The fundamental differential relation is: d h ^ = C p ( T ) d T + [ v ^ − T ( ∂ v ^ ∂ T ) P ] d P d\hat{h} = C_p(T) dT + \left[ \hat{v} - T \left(\frac{\partial \hat{v}}{\partial T}\right)_P \right] dP d h ^ = C p ( T ) d T + [ v ^ − T ( ∂ T ∂ v ^ ) P ] d P
Temperature-Dependent Heat Capacities
For ideal gases and real fluids at moderate pressures, the pressure differential vanishes, leaving d h ^ = C p ( T ) d T d\hat{h} = C_p(T) dT d h ^ = C p ( T ) d T . In the NCEES PE Chemical Reference Handbook, molar heat capacities are expressed as polynomials: C p ( T ) = a + b T + c T 2 + d T 3 C_p(T) = a + bT + cT^2 + dT^3 C p ( T ) = a + b T + c T 2 + d T 3
Integrating between temperature limits T 1 T_1 T 1 and T 2 T_2 T 2 (where T T T must be in absolute Kelvin or Rankine as specified by the correlation coefficients): Δ H ^ = ∫ T 1 T 2 C p ( T ) d T = a ( T 2 − T 1 ) + b 2 ( T 2 2 − T 1 2 ) + c 3 ( T 2 3 − T 1 3 ) + d 4 ( T 2 4 − T 1 4 ) \Delta \hat{H} = \int_{T_1}^{T_2} C_p(T) dT = a(T_2 - T_1) + \frac{b}{2}(T_2^2 - T_1^2) + \frac{c}{3}(T_2^3 - T_1^3) + \frac{d}{4}(T_2^4 - T_1^4) Δ H ^ = ∫ T 1 T 2 C p ( T ) d T = a ( T 2 − T 1 ) + 2 b ( T 2 2 − T 1 2 ) + 3 c ( T 2 3 − T 1 3 ) + 4 d ( T 2 4 − T 1 4 )
Alternatively, a mean heat capacity C ˉ p \bar{C}_p C ˉ p over the operating range can be evaluated: C ˉ p = ∫ T 1 T 2 C p ( T ) d T T 2 − T 1 ⟹ Δ H ^ = C ˉ p ( T 2 − T 1 ) \bar{C}_p = \frac{\int_{T_1}^{T_2} C_p(T) dT}{T_2 - T_1} \implies \Delta \hat{H} = \bar{C}_p (T_2 - T_1) C ˉ p = T 2 − T 1 ∫ T 1 T 2 C p ( T ) d T ⟹ Δ H ^ = C ˉ p ( T 2 − T 1 )
Incompressible Liquids and Mechanical Enthalpy
For liquids modeled as incompressible (constant specific volume v ^ \hat{v} v ^ and thermal expansion coefficient β = 1 v ^ ( ∂ v ^ / ∂ T ) P ≈ 0 \beta = \frac{1}{\hat{v}}(\partial \hat{v}/\partial T)_P \approx 0 β = v ^ 1 ( ∂ v ^ / ∂ T ) P ≈ 0 ): Δ h ^ = ∫ T 1 T 2 C p d T + v ^ ( P 2 − P 1 ) \Delta \hat{h} = \int_{T_1}^{T_2} C_p dT + \hat{v}(P_2 - P_1) Δ h ^ = ∫ T 1 T 2 C p d T + v ^ ( P 2 − P 1 )
In low-pressure liquid operations, v ^ Δ P \hat{v}\Delta P v ^ Δ P is negligible. For example, water with v ^ = 0.001 m 3 / kg \hat{v} = 0.001\text{ m}^3/\text{kg} v ^ = 0.001 m 3 / kg experiencing a 100 kPa 100\text{ kPa} 100 kPa ( 1 bar 1\text{ bar} 1 bar ) pressure rise exhibits v ^ Δ P = 0.1 kJ/kg \hat{v}\Delta P = 0.1\text{ kJ/kg} v ^ Δ P = 0.1 kJ/kg . By comparison, heating water by just 1 ∘ C 1^\circ\text{C} 1 ∘ C requires C p Δ T ≈ 4.184 kJ/kg C_p \Delta T \approx 4.184\text{ kJ/kg} C p Δ T ≈ 4.184 kJ/kg —over 40 times greater. However, in boiler feed pumps operating up to 15 MPa 15\text{ MPa} 15 MPa ( 150 bar 150\text{ bar} 150 bar ), v ^ Δ P = 0.001 m 3 / kg × 15 , 000 kPa = 15.0 kJ/kg \hat{v}\Delta P = 0.001\text{ m}^3/\text{kg} \times 15,000\text{ kPa} = 15.0\text{ kJ/kg} v ^ Δ P = 0.001 m 3 / kg × 15 , 000 kPa = 15.0 kJ/kg , which represents significant shaft work.
4. Latent Heat of Phase Changes
Phase transitions occur at constant temperature and pressure for pure components. Latent heat is the enthalpy required to alter the molecular arrangement between phases:
Latent Heat of Vaporization ( Δ H v a p \Delta H_{vap} Δ H v a p ): Liquid to vapor transition.
Latent Heat of Fusion ( Δ H f u s \Delta H_{fus} Δ H f u s ): Solid to liquid transition.
Latent Heat of Sublimation ( Δ H s u b \Delta H_{sub} Δ H s u b ): Solid directly to vapor transition, where Δ H s u b = Δ H f u s + Δ H v a p \Delta H_{sub} = \Delta H_{fus} + \Delta H_{vap} Δ H s u b = Δ H f u s + Δ H v a p at the triple point.
Temperature Dependence: The Watson Correlation
When latent heat of vaporization is tabulated only at the normal boiling point T b 1 T_{b1} T b 1 , but vaporization occurs at an elevated or reduced system pressure corresponding to saturation temperature T 2 T_2 T 2 , the Watson correlation must be applied: Δ H v a p ( T 2 ) Δ H v a p ( T 1 ) = ( 1 − T r 2 1 − T r 1 ) 0.38 = ( T c − T 2 T c − T 1 ) 0.38 \frac{\Delta H_{vap}(T_2)}{\Delta H_{vap}(T_1)} = \left( \frac{1 - T_{r2}}{1 - T_{r1}} \right)^{0.38} = \left( \frac{T_c - T_2}{T_c - T_1} \right)^{0.38} Δ H v a p ( T 1 ) Δ H v a p ( T 2 ) = ( 1 − T r 1 1 − T r 2 ) 0.38 = ( T c − T 1 T c − T 2 ) 0.38
Where:
T c T_c T c = critical temperature of the substance (absolute temperature, K \text{K} K or ∘ R ^\circ\text{R} ∘ R ).
T r = T / T c T_{r} = T / T_c T r = T / T c = reduced temperature.
As temperature approaches the critical point ( T → T c T \to T_c T → T c ), reduced temperature approaches unity ( T r → 1 T_r \to 1 T r → 1 ), and the latent heat of vaporization vanishes identically to zero ( Δ H v a p → 0 \Delta H_{vap} \to 0 Δ H v a p → 0 ).
Two-Phase Quality Calculations
For a two-phase liquid-vapor mixture (e.g., wet steam exiting a boiler or flash drum), the stream enthalpy is determined by the quality x x x (mass fraction of vapor): h ^ = ( 1 − x ) h ^ f + x h ^ g = h ^ f + x h ^ f g \hat{h} = (1 - x)\hat{h}_f + x\hat{h}_g = \hat{h}_f + x\hat{h}_{fg} h ^ = ( 1 − x ) h ^ f + x h ^ g = h ^ f + x h ^ f g
Where h ^ f \hat{h}_f h ^ f is saturated liquid enthalpy, h ^ g \hat{h}_g h ^ g is saturated vapor enthalpy, and h ^ f g = h ^ g − h ^ f = Δ h ^ v a p \hat{h}_{fg} = \hat{h}_g - \hat{h}_f = \Delta \hat{h}_{vap} h ^ f g = h ^ g − h ^ f = Δ h ^ v a p .
5. Summary Table: Enthalpy Accounting Across Regimes
Process Regime Governing Equation Primary Assumptions Key Handbook Source / Parameter
Ideal Gas Sensible Heat Δ h ^ = ∫ T 1 T 2 C p ( T ) d T \Delta \hat{h} = \int_{T_1}^{T_2} C_p(T) dT Δ h ^ = ∫ T 1 T 2 C p ( T ) d T ( ∂ h ^ / ∂ P ) T = 0 (\partial \hat{h}/\partial P)_T = 0 ( ∂ h ^ / ∂ P ) T = 0 ; moderate pressure Polynomial C p ( T ) = a + b T + c T 2 + d T 3 C_p(T) = a + bT + cT^2 + dT^3 C p ( T ) = a + b T + c T 2 + d T 3
Incompressible Liquid Δ h ^ = C ˉ p Δ T + v ^ Δ P \Delta \hat{h} = \bar{C}_p \Delta T + \hat{v}\Delta P Δ h ^ = C ˉ p Δ T + v ^ Δ P v ^ = constant \hat{v} = \text{constant} v ^ = constant ; β ≈ 0 \beta \approx 0 β ≈ 0 v ^ Δ P \hat{v}\Delta P v ^ Δ P essential for high-pressure pumping
Pure Component Boiling Δ H ^ = m ˙ Δ h ^ v a p ( T s a t ) \Delta \hat{H} = \dot{m}\Delta \hat{h}_{vap}(T_{sat}) Δ H ^ = m ˙ Δ h ^ v a p ( T s a t ) Isothermal, isobaric equilibrium Tabulated Δ h ^ v a p \Delta \hat{h}_{vap} Δ h ^ v a p at T s a t T_{sat} T s a t or steam tables
Latent Heat Scaling Δ H v a p 2 = Δ H v a p 1 [ 1 − T r 2 1 − T r 1 ] 0.38 \Delta H_{vap2} = \Delta H_{vap1} [\frac{1-T_{r2}}{1-T_{r1}}]^{0.38} Δ H v a p 2 = Δ H v a p 1 [ 1 − T r 1 1 − T r 2 ] 0.38 Pure component up to T r ≈ 0.98 T_r \approx 0.98 T r ≈ 0.98 Watson Correlation; requires T c T_c T c
Wet Vapor Mixture h ^ = h ^ f + x h ^ f g \hat{h} = \hat{h}_f + x \hat{h}_{fg} h ^ = h ^ f + x h ^ f g Thermodynamic equilibrium between phases Steam Tables / Saturation P-T tables
- 6. Worked Numerical Example: Multistage Condenser-Subcooler Sizing
- Problem Statement
An organic recovery unit processes a superheated pure ethanol vapor stream at a rate of m ˙ = 1 , 800 kg/h \dot{m} = 1,800\text{ kg/h} m ˙ = 1 , 800 kg/h ( 0.500 kg/s 0.500\text{ kg/s} 0.500 kg/s ). The vapor enters a shell-and-tube condenser at T 1 = 120.0 ∘ C T_1 = 120.0^\circ\text{C} T 1 = 120. 0 ∘ C and P = 101.325 kPa P = 101.325\text{ kPa} P = 101.325 kPa ( 1 atm 1\text{ atm} 1 atm ). The ethanol is completely condensed and subcooled to T 2 = 30.0 ∘ C T_2 = 30.0^\circ\text{C} T 2 = 30. 0 ∘ C before entering an atmospheric storage vessel.
Cooling water enters the tube side at T c w , i n = 20.0 ∘ C T_{cw,in} = 20.0^\circ\text{C} T c w , in = 20. 0 ∘ C with a permitted maximum temperature rise of Δ T c w = 15.0 ∘ C \Delta T_{cw} = 15.0^\circ\text{C} Δ T c w = 15. 0 ∘ C (exiting at 35.0 ∘ C 35.0^\circ\text{C} 35. 0 ∘ C ).
Physical Property Data for Ethanol ( M W = 46.07 g/mol MW = 46.07\text{ g/mol} M W = 46.07 g/mol ):
Normal boiling point: T b = 78.3 ∘ C T_b = 78.3^\circ\text{C} T b = 78. 3 ∘ C
Average vapor heat capacity: C p , V = 1.750 kJ/(kg ⋅ K) C_{p,V} = 1.750\text{ kJ/(kg}\cdot\text{K)} C p , V = 1.750 kJ/(kg ⋅ K)
Latent heat of vaporization at 78.3 ∘ C 78.3^\circ\text{C} 78. 3 ∘ C : Δ h ^ v a p = 846.0 kJ/kg \Delta \hat{h}_{vap} = 846.0\text{ kJ/kg} Δ h ^ v a p = 846.0 kJ/kg
Average liquid heat capacity: C p , L = 2.570 kJ/(kg ⋅ K) C_{p,L} = 2.570\text{ kJ/(kg}\cdot\text{K)} C p , L = 2.570 kJ/(kg ⋅ K)
Cooling water heat capacity: C p , w = 4.184 kJ/(kg ⋅ K) C_{p,w} = 4.184\text{ kJ/(kg}\cdot\text{K)} C p , w = 4.184 kJ/(kg ⋅ K)
Calculate:
The desuperheating duty ( Q ˙ 1 \dot{Q}_1 Q ˙ 1 ).
The condensation duty ( Q ˙ 2 \dot{Q}_2 Q ˙ 2 ).
The subcooling duty ( Q ˙ 3 \dot{Q}_3 Q ˙ 3 ).
The total heat removal rate ( Q ˙ t o t a l \dot{Q}_{total} Q ˙ t o t a l ).
The required cooling water mass flow rate ( m ˙ c w \dot{m}_{cw} m ˙ c w ).
- Step-by-Step Solution
- Step 1: Construct the Hypothetical Path for Ethanol
The process operates at steady state with no shaft work ( W ˙ s = 0 \dot{W}_s = 0 W ˙ s = 0 ). Hence, Q ˙ = Δ H ˙ \dot{Q} = \Delta \dot{H} Q ˙ = Δ H ˙ . The path breaks into three sequential steps: Δ H ˙ = Δ H ˙ 1 + Δ H ˙ 2 + Δ H ˙ 3 \Delta \dot{H} = \Delta \dot{H}_1 + \Delta \dot{H}_2 + \Delta \dot{H}_3 Δ H ˙ = Δ H ˙ 1 + Δ H ˙ 2 + Δ H ˙ 3
Step 2: Zone 1 — Desuperheating the Vapor ( 120.0 ∘ C → 78.3 ∘ C 120.0^\circ\text{C} \to 78.3^\circ\text{C} 120. 0 ∘ C → 78. 3 ∘ C ) Δ H ˙ 1 = m ˙ ∫ 120.0 78.3 C p , V d T = m ˙ C p , V ( T b − T 1 ) \Delta \dot{H}_1 = \dot{m} \int_{120.0}^{78.3} C_{p,V} dT = \dot{m} C_{p,V} (T_b - T_1) Δ H ˙ 1 = m ˙ ∫ 120.0 78.3 C p , V d T = m ˙ C p , V ( T b − T 1 ) Δ H ˙ 1 = ( 0.500 kg/s ) × ( 1.750 kJ/(kg ⋅ K) ) × ( 78.3 − 120.0 ) K \Delta \dot{H}_1 = (0.500\text{ kg/s}) \times (1.750\text{ kJ/(kg}\cdot\text{K)}) \times (78.3 - 120.0)\text{ K} Δ H ˙ 1 = ( 0.500 kg/s ) × ( 1.750 kJ/(kg ⋅ K) ) × ( 78.3 − 120.0 ) K Δ H ˙ 1 = ( 0.500 ) × ( 1.750 ) × ( − 41.7 ) = − 36.488 kW \Delta \dot{H}_1 = (0.500) \times (1.750) \times (-41.7) = -36.488\text{ kW} Δ H ˙ 1 = ( 0.500 ) × ( 1.750 ) × ( − 41.7 ) = − 36.488 kW
Step 3: Zone 2 — Condensing Saturated Vapor to Saturated Liquid ( 78.3 ∘ C 78.3^\circ\text{C} 78. 3 ∘ C )
Vaporization is endothermic ( + Δ h ^ v a p +\Delta \hat{h}_{vap} + Δ h ^ v a p ); condensation is exothermic ( − Δ h ^ v a p -\Delta \hat{h}_{vap} − Δ h ^ v a p ): Δ H ˙ 2 = − m ˙ Δ h ^ v a p \Delta \dot{H}_2 = -\dot{m} \Delta \hat{h}_{vap} Δ H ˙ 2 = − m ˙ Δ h ^ v a p Δ H ˙ 2 = − ( 0.500 kg/s ) × ( 846.0 kJ/kg ) = − 423.000 kW \Delta \dot{H}_2 = -(0.500\text{ kg/s}) \times (846.0\text{ kJ/kg}) = -423.000\text{ kW} Δ H ˙ 2 = − ( 0.500 kg/s ) × ( 846.0 kJ/kg ) = − 423.000 kW
Step 4: Zone 3 — Subcooling the Liquid ( 78.3 ∘ C → 30.0 ∘ C 78.3^\circ\text{C} \to 30.0^\circ\text{C} 78. 3 ∘ C → 30. 0 ∘ C ) Δ H ˙ 3 = m ˙ ∫ 78.3 30.0 C p , L d T = m ˙ C p , L ( T 2 − T b ) \Delta \dot{H}_3 = \dot{m} \int_{78.3}^{30.0} C_{p,L} dT = \dot{m} C_{p,L} (T_2 - T_b) Δ H ˙ 3 = m ˙ ∫ 78.3 30.0 C p , L d T = m ˙ C p , L ( T 2 − T b ) Δ H ˙ 3 = ( 0.500 kg/s ) × ( 2.570 kJ/(kg ⋅ K) ) × ( 30.0 − 78.3 ) K \Delta \dot{H}_3 = (0.500\text{ kg/s}) \times (2.570\text{ kJ/(kg}\cdot\text{K)}) \times (30.0 - 78.3)\text{ K} Δ H ˙ 3 = ( 0.500 kg/s ) × ( 2.570 kJ/(kg ⋅ K) ) × ( 30.0 − 78.3 ) K Δ H ˙ 3 = ( 0.500 ) × ( 2.570 ) × ( − 48.3 ) = − 62.066 kW \Delta \dot{H}_3 = (0.500) \times (2.570) \times (-48.3) = -62.066\text{ kW} Δ H ˙ 3 = ( 0.500 ) × ( 2.570 ) × ( − 48.3 ) = − 62.066 kW
Step 5: Total Heat Duty Q ˙ t o t a l = Δ H ˙ 1 + Δ H ˙ 2 + Δ H ˙ 3 = − 36.488 − 423.000 − 62.066 = − 521.554 kW ≈ − 521.6 kW \dot{Q}_{total} = \Delta \dot{H}_1 + \Delta \dot{H}_2 + \Delta \dot{H}_3 = -36.488 - 423.000 - 62.066 = -521.554\text{ kW} \approx -521.6\text{ kW} Q ˙ t o t a l = Δ H ˙ 1 + Δ H ˙ 2 + Δ H ˙ 3 = − 36.488 − 423.000 − 62.066 = − 521.554 kW ≈ − 521.6 kW
The cooling duty required is 521.6 kW 521.6\text{ kW} 521.6 kW removed from the ethanol stream. Condensation accounts for 423.0 / 521.6 = 81.1 % 423.0 / 521.6 = 81.1\% 423.0/521.6 = 81.1% of the total duty.
Step 6: Cooling Water Flow Rate
An energy balance on the tube side yields Q ˙ a b s o r b e d = − Q ˙ t o t a l = 521.554 kW \dot{Q}_{absorbed} = -\dot{Q}_{total} = 521.554\text{ kW} Q ˙ ab sor b e d = − Q ˙ t o t a l = 521.554 kW : m ˙ c w = Q ˙ a b s o r b e d C p , w Δ T c w = 521.554 kJ/s ( 4.184 kJ/(kg ⋅ K) ) × ( 15.0 K ) = 521.554 62.76 = 8.310 kg/s \dot{m}_{cw} = \frac{\dot{Q}_{absorbed}}{C_{p,w} \Delta T_{cw}} = \frac{521.554\text{ kJ/s}}{(4.184\text{ kJ/(kg}\cdot\text{K)}) \times (15.0\text{ K})} = \frac{521.554}{62.76} = 8.310\text{ kg/s} m ˙ c w = C p , w Δ T c w Q ˙ ab sor b e d = ( 4.184 kJ/(kg ⋅ K) ) × ( 15.0 K ) 521.554 kJ/s = 62.76 521.554 = 8.310 kg/s
In hourly mass units: 8.310 kg/s × 3 , 600 s/h = 29 , 916 kg/h 8.310\text{ kg/s} \times 3,600\text{ s/h} = 29,916\text{ kg/h} 8.310 kg/s × 3 , 600 s/h = 29 , 916 kg/h .
- 7. Critical PE Exam Traps & Pitfalls
- Trap 1: Misinterpreting Reference States Across Sources
Steam tables set liquid internal energy and enthalpy to zero at the triple point of water ( 0.01 ∘ C 0.01^\circ\text{C} 0.0 1 ∘ C , 0.00611 bar 0.00611\text{ bar} 0.00611 bar ). Chemical thermodynamic tables (like Perry's or NIST) set the elemental standard enthalpy of formation to zero at 25 ∘ C 25^\circ\text{C} 2 5 ∘ C ( 298.15 K 298.15\text{ K} 298.15 K ) and 1 bar 1\text{ bar} 1 bar . If you calculate Δ H \Delta H Δ H for water by subtracting a steam table enthalpy from a NIST enthalpy, your answer will be off by approximately 105 kJ/kg 105\text{ kJ/kg} 105 kJ/kg ! Always compute stream differences using the same reference source.
Trap 2: Ignoring Temperature Variations in Latent Heat
The latent heat of vaporization decreases significantly as temperature increases. Using the normal boiling point latent heat Δ H v a p ( T b ) \Delta H_{vap}(T_b) Δ H v a p ( T b ) for a high-pressure reboiler running at elevated saturation temperature severely overpredicts the available heat duty and undersizes heat transfer areas. Always scale with Watson's correlation when working at off-normal pressures.
Trap 3: Sign Confusion on Shaft Work
The standard NCEES open-system formulation writes Q ˙ − W ˙ s = Δ H ˙ \dot{Q} - \dot{W}_s = \Delta \dot{H} Q ˙ − W ˙ s = Δ H ˙ . When solving for a pump or compressor that consumes energy, W ˙ s \dot{W}_s W ˙ s is negative. Therefore, Δ H ˙ = Q ˙ − ( − W ˙ p u m p ) = Q ˙ + W ˙ p u m p \Delta \dot{H} = \dot{Q} - (-\dot{W}_{pump}) = \dot{Q} + \dot{W}_{pump} Δ H ˙ = Q ˙ − ( − W ˙ p u m p ) = Q ˙ + W ˙ p u m p . The enthalpy of the fluid increases due to mechanical work input.