Study guide
2.3 Unsteady-State Mass and Energy Balances
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
2.3 Unsteady-State Mass and Energy Balances
Key Takeaways Explain This Topic AI
The fundamental macroscopic unsteady balance equation states: Rate of Accumulation = Rate of Inflow - Rate of Outflow + Rate of Generation - Rate of Consumption.
In transient First Law energy balances, the rate of energy accumulation within the control volume is governed by internal energy, d(U_sys)/dt = d(m * u_hat)/dt, whereas streams crossing system boundaries transport flowing enthalpy, h_hat = u_hat + P * v_hat, carrying flow work.
For constant-mass, well-mixed liquid heating and cooling systems without phase change, thermal response follows first-order exponential dynamics: T(t) = T_env - (T_env - T_0) * exp(-t / τ_th), where the thermal time constant is τ_th = (m * C_p) / (U * A).
Adiabatic filling of an initially evacuated rigid tank with an ideal gas increases the internal gas temperature to T_final = γ * T_supply (where γ = C_p / C_v), driven entirely by the conversion of flowing enthalpy into stored internal energy.
In gravity draining of tanks through sharp-edged orifices, discharge velocity depends non-linearly on the instantaneous liquid head (Torricelli's Law: v = C_d * sqrt(2gh)), requiring direct separation and integration of h^(-1/2) dh rather than assuming constant flow or linear decay.
Last updated: September 2026
Unsteady-State Mass and Energy Balances
While steady-state operations dominate bulk continuous chemical manufacturing, unsteady-state (transient) processes are ubiquitous during plant startups, emergency shutdowns, batch reactor cycles, tank draining, vessel blowdowns, and process control upsets. On the NCEES PE Chemical exam, transient questions test your ability to formulate differential balance equations, separate variables, and integrate using proper boundary conditions.
1. General Macroscopic Conservation Balance
For any conserved physical quantity Ψ \Psi Ψ (mass, component mass, or energy) within a defined spatial control volume: d Ψ s y s d t = Ψ ˙ i n − Ψ ˙ o u t + Ψ ˙ g e n − Ψ ˙ c o n s \frac{d\Psi_{sys}}{dt} = \dot{\Psi}_{in} - \dot{\Psi}_{out} + \dot{\Psi}_{gen} - \dot{\Psi}_{cons} d t d Ψ sys = Ψ ˙ in − Ψ ˙ o u t + Ψ ˙ g e n − Ψ ˙ co n s
Transient Total Mass Balance
Because total mass cannot be created or destroyed ( m ˙ g e n = m ˙ c o n s = 0 \dot{m}_{gen} = \dot{m}_{cons} = 0 m ˙ g e n = m ˙ co n s = 0 ): d m s y s d t = ∑ i n m ˙ i n − ∑ o u t m ˙ o u t \frac{dm_{sys}}{dt} = \sum_{in} \dot{m}_{in} - \sum_{out} \dot{m}_{out} d t d m sys = in ∑ m ˙ in − o u t ∑ m ˙ o u t
For an open liquid tank of constant surface area A A A and constant liquid density ρ \rho ρ , m s y s = ρ A h ( t ) m_{sys} = \rho A h(t) m sys = ρ A h ( t ) , where h ( t ) h(t) h ( t ) is liquid level: ρ A d h d t = ∑ m ˙ i n − ∑ m ˙ o u t ⟹ A d h d t = ∑ V ˙ i n − ∑ V ˙ o u t \rho A \frac{dh}{dt} = \sum \dot{m}_{in} - \sum \dot{m}_{out} \implies A \frac{dh}{dt} = \sum \dot{V}_{in} - \sum \dot{V}_{out} ρ A d t d h = ∑ m ˙ in − ∑ m ˙ o u t ⟹ A d t d h = ∑ V ˙ in − ∑ V ˙ o u t
Transient Component (Species) Balance
For chemical species i i i participating in reactions with volumetric rate r i r_i r i ( mol/(m 3 ⋅ s) \text{mol/(m}^3\cdot\text{s)} mol/(m 3 ⋅ s) ): d n i d t = ∑ i n n ˙ i , i n − ∑ o u t n ˙ i , o u t + r i V \frac{d n_i}{dt} = \sum_{in} \dot{n}_{i,in} - \sum_{out} \dot{n}_{i,out} + r_i V d t d n i = in ∑ n ˙ i , in − o u t ∑ n ˙ i , o u t + r i V
For a non-reactive, perfectly mixed continuous stirred tank of constant volume V V V and volumetric throughput V ˙ \dot{V} V ˙ ( n i = V C i ( t ) n_i = V C_i(t) n i = V C i ( t ) and C i , o u t ( t ) = C i ( t ) C_{i,out}(t) = C_i(t) C i , o u t ( t ) = C i ( t ) ): V d C i d t = V ˙ C i , i n − V ˙ C i ( t ) V \frac{dC_i}{dt} = \dot{V} C_{i,in} - \dot{V} C_i(t) V d t d C i = V ˙ C i , in − V ˙ C i ( t )
Dividing by V ˙ \dot{V} V ˙ defines the hydraulic residence time (time constant τ = V / V ˙ \tau = V / \dot{V} τ = V / V ˙ ): τ d C i d t + C i ( t ) = C i , i n \tau \frac{dC_i}{dt} + C_i(t) = C_{i,in} τ d t d C i + C i ( t ) = C i , in
Integrating from initial concentration C 0 C_0 C 0 at t = 0 t = 0 t = 0 with a step change in inlet concentration to C i n C_{in} C in yields the classic first-order response: C i ( t ) = C i n + ( C 0 − C i n ) e − t / τ = C i n ( 1 − e − t / τ ) + C 0 e − t / τ C_i(t) = C_{in} + (C_0 - C_{in}) e^{-t / \tau} = C_{in}\left(1 - e^{-t / \tau}\right) + C_0 e^{-t / \tau} C i ( t ) = C in + ( C 0 − C in ) e − t / τ = C in ( 1 − e − t / τ ) + C 0 e − t / τ
2. Transient First Law Energy Balances
The general First Law of Thermodynamics for an unsteady open system is: d E s y s d t = Q ˙ − W ˙ s + ∑ i n m ˙ i n ( h ^ + u 2 2 + g z ) i n − ∑ o u t m ˙ o u t ( h ^ + u 2 2 + g z ) o u t \frac{d E_{sys}}{dt} = \dot{Q} - \dot{W}_s + \sum_{in} \dot{m}_{in} \left( \hat{h} + \frac{u^2}{2} + gz \right)_{in} - \sum_{out} \dot{m}_{out} \left( \hat{h} + \frac{u^2}{2} + gz \right)_{out} d t d E sys = Q ˙ − W ˙ s + in ∑ m ˙ in ( h ^ + 2 u 2 + g z ) in − o u t ∑ m ˙ o u t ( h ^ + 2 u 2 + g z ) o u t
Neglecting kinetic and potential energies, total system energy equals internal energy ( E s y s = U s y s = m s y s u ^ s y s E_{sys} = U_{sys} = m_{sys} \hat{u}_{sys} E sys = U sys = m sys u ^ sys ): d ( m s y s u ^ s y s ) d t = Q ˙ − W ˙ s + ∑ i n m ˙ i n h ^ i n − ∑ o u t m ˙ o u t h ^ o u t \frac{d(m_{sys} \hat{u}_{sys})}{dt} = \dot{Q} - \dot{W}_s + \sum_{in} \dot{m}_{in} \hat{h}_{in} - \sum_{out} \dot{m}_{out} \hat{h}_{out} d t d ( m sys u ^ sys ) = Q ˙ − W ˙ s + in ∑ m ˙ in h ^ in − o u t ∑ m ˙ o u t h ^ o u t
The Fundamental Internal Energy vs. Enthalpy Asymmetry
Notice the profound thermodynamic distinction in the governing equation:
Inside the control volume , energy is stored as internal energy ( u ^ \hat{u} u ^ ).
Across the control surface boundaries , flowing streams transport enthalpy ( h ^ = u ^ + P v ^ \hat{h} = \hat{u} + P\hat{v} h ^ = u ^ + P v ^ ).
Why? Because fluid entering or exiting the boundary performs boundary work (flow work P v ^ P\hat{v} P v ^ ) on or by the system fluid. Omitting this distinction is the single most pervasive source of error in transient thermodynamics.
Applying the product rule to the accumulation derivative: d ( m u ^ ) d t = m d u ^ d t + u ^ d m d t \frac{d(m \hat{u})}{dt} = m \frac{d\hat{u}}{dt} + \hat{u} \frac{dm}{dt} d t d ( m u ^ ) = m d t d u ^ + u ^ d t d m
For liquids and solids, u ^ ≈ h ^ ≈ C p ( T − T r e f ) \hat{u} \approx \hat{h} \approx C_p(T - T_{ref}) u ^ ≈ h ^ ≈ C p ( T − T re f ) because specific volume is small. For gases, u ^ = C v ( T − T r e f ) \hat{u} = C_v(T - T_{ref}) u ^ = C v ( T − T re f ) and h ^ = C p ( T − T r e f ) \hat{h} = C_p(T - T_{ref}) h ^ = C p ( T − T re f ) .
3. Jacketed Batch and Semi-Batch Heating / Cooling
Consider a well-insulated, closed batch reactor of liquid mass m m m and heat capacity C p C_p C p being heated by an external jacket maintained at constant temperature T j T_j T j : m ˙ i n = 0 , m ˙ o u t = 0 , W ˙ s ≈ 0 (ignoring agitator friction) \dot{m}_{in} = 0, \quad \dot{m}_{out} = 0, \quad \dot{W}_s \approx 0 \text{ (ignoring agitator friction)} m ˙ in = 0 , m ˙ o u t = 0 , W ˙ s ≈ 0 (ignoring agitator friction) d ( m u ^ ) d t = m C p d T d t = Q ˙ \frac{d(m \hat{u})}{dt} = m C_p \frac{dT}{dt} = \dot{Q} d t d ( m u ^ ) = m C p d t d T = Q ˙
Heat transfer from the jacket follows Newton's Law of Cooling: Q ˙ = U A ( T j − T ( t ) ) \dot{Q} = U A (T_j - T(t)) Q ˙ = U A ( T j − T ( t )) , where U U U is the overall heat transfer coefficient and A A A is heat transfer surface area: m C p d T d t = U A ( T j − T ( t ) ) m C_p \frac{dT}{dt} = U A (T_j - T(t)) m C p d t d T = U A ( T j − T ( t ))
Rearranging into standard first-order differential form: d T d t + U A m C p T ( t ) = U A m C p T j \frac{dT}{dt} + \frac{U A}{m C_p} T(t) = \frac{U A}{m C_p} T_j d t d T + m C p U A T ( t ) = m C p U A T j
Defining the thermal time constant : τ t h = m C p U A \tau_{th} = \frac{m C_p}{U A} τ t h = U A m C p
Separating variables from t = 0 t = 0 t = 0 ( T = T 0 T = T_0 T = T 0 ) to time t t t : ∫ T 0 T ( t ) d T T j − T = 1 τ t h ∫ 0 t d t ⟹ − ln ( T j − T ( t ) T j − T 0 ) = t τ t h \int_{T_0}^{T(t)} \frac{dT}{T_j - T} = \frac{1}{\tau_{th}} \int_0^t dt \implies -\ln\left(\frac{T_j - T(t)}{T_j - T_0}\right) = \frac{t}{\tau_{th}} ∫ T 0 T ( t ) T j − T d T = τ t h 1 ∫ 0 t d t ⟹ − ln ( T j − T 0 T j − T ( t ) ) = τ t h t
Solving explicitly for vessel temperature T ( t ) T(t) T ( t ) : T ( t ) = T j − ( T j − T 0 ) exp ( − t τ t h ) T(t) = T_j - (T_j - T_0) \exp\left(-\frac{t}{\tau_{th}}\right) T ( t ) = T j − ( T j − T 0 ) exp ( − τ t h t )
The time t t t required to reach a specific process temperature T ( t ) T(t) T ( t ) is: t = τ t h ln ( T j − T 0 T j − T ( t ) ) = m C p U A ln ( T j − T 0 T j − T ( t ) ) t = \tau_{th} \ln\left( \frac{T_j - T_0}{T_j - T(t)} \right) = \frac{m C_p}{U A} \ln\left( \frac{T_j - T_0}{T_j - T(t)} \right) t = τ t h ln ( T j − T ( t ) T j − T 0 ) = U A m C p ln ( T j − T ( t ) T j − T 0 )
4. Gas Vessel Pressurization: The Evacuated Tank Paradox
Consider a rigid, thermally insulated tank of volume V V V that is initially evacuated ( m 1 = 0 m_1 = 0 m 1 = 0 , P 1 = 0 P_1 = 0 P 1 = 0 ). A supply valve connected to a high-pressure header carrying an ideal gas at temperature T 0 T_0 T 0 is opened, filling the tank until flow stops. What is the final temperature T 2 T_2 T 2 in the tank?
Setting up the transient First Law balance:
- Rigid tank: W ˙ s = 0 \dot{W}_s = 0 W ˙ s = 0
- Insulated: Q ˙ = 0 \dot{Q} = 0 Q ˙ = 0
No exit stream: m ˙ o u t = 0 \dot{m}_{out} = 0 m ˙ o u t = 0 d ( m u ^ ) d t = m ˙ i n h ^ i n \frac{d(m \hat{u})}{dt} = \dot{m}_{in} \hat{h}_{in} d t d ( m u ^ ) = m ˙ in h ^ in
Integrating from initial state ( m = 0 m=0 m = 0 ) to final state ( m 2 m_2 m 2 ): m 2 u ^ 2 − 0 = Δ m i n h ^ i n = m 2 h ^ i n m_2 \hat{u}_2 - 0 = \Delta m_{in} \hat{h}_{in} = m_2 \hat{h}_{in} m 2 u ^ 2 − 0 = Δ m in h ^ in = m 2 h ^ in
Dividing by m 2 m_2 m 2 : u ^ 2 = h ^ i n \hat{u}_2 = \hat{h}_{in} u ^ 2 = h ^ in
For an ideal gas referenced to absolute zero ( T r e f = 0 K T_{ref} = 0\text{ K} T re f = 0 K ), u ^ 2 = C v T 2 \hat{u}_2 = C_v T_2 u ^ 2 = C v T 2 and h ^ i n = C p T 0 \hat{h}_{in} = C_p T_0 h ^ in = C p T 0 : C v T 2 = C p T 0 ⟹ T 2 = C p C v T 0 = γ T 0 C_v T_2 = C_p T_0 \implies T_2 = \frac{C_p}{C_v} T_0 = \gamma T_0 C v T 2 = C p T 0 ⟹ T 2 = C v C p T 0 = γ T 0
Where γ = C p / C v \gamma = C_p / C_v γ = C p / C v is the heat capacity ratio ( 1.40 1.40 1.40 for diatomic gases such as N 2 \text{N}_2 N 2 , O 2 \text{O}_2 O 2 , and air).
Key Insight: If room-temperature air at 25 ∘ C 25^\circ\text{C} 2 5 ∘ C ( 298.15 K 298.15\text{ K} 298.15 K ) fills an evacuated tank adiabatically, the final temperature inside the tank spikes to: T 2 = 1.40 × 298.15 K = 417.4 K = 144.3 ∘ C ! T_2 = 1.40 \times 298.15\text{ K} = 417.4\text{ K} = 144.3^\circ\text{C}! T 2 = 1.40 × 298.15 K = 417.4 K = 144. 3 ∘ C !
The gas heats up drastically without any external heat addition because the incoming fluid carries flowing enthalpy P v ^ P\hat{v} P v ^ (work done by the supply header), which is converted entirely into internal thermal energy inside the rigid vessel.
5. Gravity Draining Hydraulics: Torricelli's Law
When a liquid-filled vertical cylindrical tank drains by gravity through an open bottom orifice of area A o A_o A o , the discharge velocity is non-linear and governed by Torricelli's Law: ν o u t ( t ) = C d 2 g h ( t ) \nu_{out}(t) = C_d \sqrt{2 g h(t)} ν o u t ( t ) = C d 2 g h ( t )
Where C d C_d C d is the discharge coefficient ( 0.60 0.60 0.60 to 0.62 0.62 0.62 for sharp-edged orifices) and h ( t ) h(t) h ( t ) is instantaneous liquid head above the orifice.
Setting up the transient total mass balance ( A d h d t = − V ˙ o u t A \frac{dh}{dt} = -\dot{V}_{out} A d t d h = − V ˙ o u t ): A d h d t = − C d A o 2 g h A \frac{dh}{dt} = -C_d A_o \sqrt{2 g h} A d t d h = − C d A o 2 g h
Separating variables: h − 1 / 2 d h = − C d A o 2 g A d t h^{-1/2} dh = -\frac{C_d A_o \sqrt{2g}}{A} dt h − 1/2 d h = − A C d A o 2 g d t
Integrating from initial height h 0 h_0 h 0 at t = 0 t = 0 t = 0 to height h f h_f h f at time t t t : ∫ h 0 h f h − 1 / 2 d h = 2 ( h f − h 0 ) = − C d A o 2 g A t \int_{h_0}^{h_f} h^{-1/2} dh = 2\left(\sqrt{h_f} - \sqrt{h_0}\right) = -\frac{C_d A_o \sqrt{2g}}{A} t ∫ h 0 h f h − 1/2 d h = 2 ( h f − h 0 ) = − A C d A o 2 g t
Solving for draining time t t t : t = 2 A ( h 0 − h f ) C d A o 2 g t = \frac{2 A \left( \sqrt{h_0} - \sqrt{h_f} \right)}{C_d A_o \sqrt{2g}} t = C d A o 2 g 2 A ( h 0 − h f )
To drain the tank completely to h f = 0 h_f = 0 h f = 0 : t e m p t y = 2 A h 0 C d A o 2 g t_{empty} = \frac{2 A \sqrt{h_0}}{C_d A_o \sqrt{2g}} t e m pt y = C d A o 2 g 2 A h 0
Notice that draining from h 0 h_0 h 0 to 0 0 0 takes exactly twice as long as it would if the initial discharge rate had remained constant!
6. Summary: Canonical Transient Balance Archetypes
System Type Governing Differential Equation Analytical Solution Characteristic Time Constant
Continuous Dilution Tank V d C d t = V ˙ ( C i n − C ) V \frac{dC}{dt} = \dot{V}(C_{in} - C) V d t d C = V ˙ ( C in − C ) C ( t ) = C i n + ( C 0 − C i n ) e − t / τ C(t) = C_{in} + (C_0 - C_{in})e^{-t/\tau} C ( t ) = C in + ( C 0 − C in ) e − t / τ τ = V V ˙ \tau = \frac{V}{\dot{V}} τ = V ˙ V (Hydraulic)
Batch Liquid Heating m C p d T d t = U A ( T j − T ) m C_p \frac{dT}{dt} = UA(T_j - T) m C p d t d T = U A ( T j − T ) T ( t ) = T j − ( T j − T 0 ) e − t / τ t h T(t) = T_j - (T_j - T_0)e^{-t/\tau_{th}} T ( t ) = T j − ( T j − T 0 ) e − t / τ t h τ t h = m C p U A \tau_{th} = \frac{m C_p}{UA} τ t h = U A m C p (Thermal)
Evacuated Gas Filling d ( m u ^ ) d t = m ˙ i n h ^ i n \frac{d(m \hat{u})}{dt} = \dot{m}_{in}\hat{h}_{in} d t d ( m u ^ ) = m ˙ in h ^ in T f i n a l = γ T s u p p l y T_{final} = \gamma T_{supply} T f ina l = γ T s u ppl y Immediate upon pressure equalization
Torricelli Tank Draining A d h d t = − C d A o 2 g h A \frac{dh}{dt} = -C_d A_o \sqrt{2gh} A d t d h = − C d A o 2 g h t = 2 A ( h 0 − h ) C d A o 2 g t = \frac{2A(\sqrt{h_0}-\sqrt{h})}{C_d A_o \sqrt{2g}} t = C d A o 2 g 2 A ( h 0 − h ) t e m p t y = 2 A h 0 C d A o 2 g t_{empty} = \frac{2A\sqrt{h_0}}{C_d A_o \sqrt{2g}} t e m pt y = C d A o 2 g 2 A h 0
- 7. Worked Numerical Example: Jacketed Polymerization Reactor Heating
- Problem Statement
A batch chemical reactor holds m = 2 , 500 kg m = 2,500\text{ kg} m = 2 , 500 kg of a liquid monomer mixture ( C p = 3.500 kJ/(kg ⋅ K) C_p = 3.500\text{ kJ/(kg}\cdot\text{K)} C p = 3.500 kJ/(kg ⋅ K) ) at an initial temperature of T 0 = 20.0 ∘ C T_0 = 20.0^\circ\text{C} T 0 = 20. 0 ∘ C . To initiate polymerization, the charge must be preheated to T ( t ) = 110.0 ∘ C T(t) = 110.0^\circ\text{C} T ( t ) = 110. 0 ∘ C .
Heating is provided by condensing saturated steam inside a reactor jacket at P s a t = 0.3614 MPa P_{sat} = 0.3614\text{ MPa} P s a t = 0.3614 MPa , maintaining a constant inner wall temperature of T j = 140.0 ∘ C T_j = 140.0^\circ\text{C} T j = 140. 0 ∘ C .
Vessel Specifications:
Effective heat transfer area: A = 5.20 m 2 A = 5.20\text{ m}^2 A = 5.20 m 2
Overall heat transfer coefficient: U = 450.0 W/(m 2 ⋅ K) U = 450.0\text{ W/(m}^2\cdot\text{K)} U = 450.0 W/(m 2 ⋅ K)
Latent heat of steam condensation at 140.0 ∘ C 140.0^\circ\text{C} 140. 0 ∘ C : λ v a p = 2 , 144.0 kJ/kg \lambda_{vap} = 2,144.0\text{ kJ/kg} λ v a p = 2 , 144.0 kJ/kg
Calculate:
The thermal time constant of the reactor system ( τ t h \tau_{th} τ t h ).
The time required to reach the target temperature of 110.0 ∘ C 110.0^\circ\text{C} 110. 0 ∘ C (in minutes).
The total thermal energy transferred to the batch ( MJ \text{MJ} MJ ).
The total mass of steam condensed during the heat-up cycle ( kg \text{kg} kg ).
Step-by-Step Solution
Step 1: Calculate the Thermal Time Constant τ t h = m C p U A \tau_{th} = \frac{m C_p}{U A} τ t h = U A m C p
Convert U U U and C p C_p C p to consistent SI units:
m C p = ( 2 , 500 kg ) × ( 3 , 500 J/(kg ⋅ K) ) = 8 , 750 , 000 J/K m C_p = (2,500\text{ kg}) \times (3,500\text{ J/(kg}\cdot\text{K)}) = 8,750,000\text{ J/K} m C p = ( 2 , 500 kg ) × ( 3 , 500 J/(kg ⋅ K) ) = 8 , 750 , 000 J/K
U A = ( 450.0 W/(m 2 ⋅ K) ) × ( 5.20 m 2 ) = 2 , 340.0 W = 2 , 340.0 J/s ⋅ K U A = (450.0\text{ W/(m}^2\cdot\text{K)}) \times (5.20\text{ m}^2) = 2,340.0\text{ W} = 2,340.0\text{ J/s}\cdot\text{K} U A = ( 450.0 W/(m 2 ⋅ K) ) × ( 5.20 m 2 ) = 2 , 340.0 W = 2 , 340.0 J/s ⋅ K τ t h = 8 , 750 , 000 J/K 2 , 340.0 J/s ⋅ K = 3 , 739.32 seconds \tau_{th} = \frac{8,750,000\text{ J/K}}{2,340.0\text{ J/s}\cdot\text{K}} = 3,739.32\text{ seconds} τ t h = 2 , 340.0 J/s ⋅ K 8 , 750 , 000 J/K = 3 , 739.32 seconds
In minutes: τ t h = 3 , 739.32 / 60 = 62.32 minutes \tau_{th} = 3,739.32 / 60 = 62.32\text{ minutes} τ t h = 3 , 739.32/60 = 62.32 minutes .
Step 2: Time to Reach 110.0 ∘ C 110.0^\circ\text{C} 110. 0 ∘ C T j − T ( t ) T j − T 0 = 140.0 − 110.0 140.0 − 20.0 = 30.0 120.0 = 0.250 \frac{T_j - T(t)}{T_j - T_0} = \frac{140.0 - 110.0}{140.0 - 20.0} = \frac{30.0}{120.0} = 0.250 T j − T 0 T j − T ( t ) = 140.0 − 20.0 140.0 − 110.0 = 120.0 30.0 = 0.250 t = τ t h ln ( T j − T 0 T j − T ( t ) ) = 3 , 739.32 s × ln ( 1 0.250 ) = 3 , 739.32 × ln ( 4.000 ) t = \tau_{th} \ln\left( \frac{T_j - T_0}{T_j - T(t)} \right) = 3,739.32\text{ s} \times \ln\left( \frac{1}{0.250} \right) = 3,739.32 \times \ln(4.000) t = τ t h ln ( T j − T ( t ) T j − T 0 ) = 3 , 739.32 s × ln ( 0.250 1 ) = 3 , 739.32 × ln ( 4.000 ) t = 3 , 739.32 s × 1.38629 = 5 , 183.80 seconds t = 3,739.32\text{ s} \times 1.38629 = 5,183.80\text{ seconds} t = 3 , 739.32 s × 1.38629 = 5 , 183.80 seconds
Converting to minutes: t = 5 , 183.80 s 60 s/min = 86.40 minutes ≈ 1.44 hours t = \frac{5,183.80\text{ s}}{60\text{ s/min}} = 86.40\text{ minutes} \approx 1.44\text{ hours} t = 60 s/min 5 , 183.80 s = 86.40 minutes ≈ 1.44 hours
Step 3: Total Heat Transferred to Monomer Q t o t a l = m C p ( T f − T 0 ) = ( 2 , 500 kg ) × ( 3.500 kJ/(kg ⋅ K) ) × ( 110.0 − 20.0 K ) Q_{total} = m C_p (T_f - T_0) = (2,500\text{ kg}) \times (3.500\text{ kJ/(kg}\cdot\text{K)}) \times (110.0 - 20.0\text{ K}) Q t o t a l = m C p ( T f − T 0 ) = ( 2 , 500 kg ) × ( 3.500 kJ/(kg ⋅ K) ) × ( 110.0 − 20.0 K ) Q t o t a l = ( 2 , 500 ) × ( 3.500 ) × ( 90.0 ) = 787 , 500 kJ = 787.5 MJ Q_{total} = (2,500) \times (3.500) \times (90.0) = 787,500\text{ kJ} = 787.5\text{ MJ} Q t o t a l = ( 2 , 500 ) × ( 3.500 ) × ( 90.0 ) = 787 , 500 kJ = 787.5 MJ
Step 4: Total Steam Condensed
Assuming steam enters as saturated vapor and leaves as saturated condensate without subcooling: m s t e a m = Q t o t a l λ v a p = 787 , 500 kJ 2 , 144.0 kJ/kg = 367.30 kg of steam m_{steam} = \frac{Q_{total}}{\lambda_{vap}} = \frac{787,500\text{ kJ}}{2,144.0\text{ kJ/kg}} = 367.30\text{ kg of steam} m s t e am = λ v a p Q t o t a l = 2 , 144.0 kJ/kg 787 , 500 kJ = 367.30 kg of steam
Average steam condensation rate over the heat-up cycle: m ˙ s t e a m , a v g = 367.30 kg 1.44 h = 255.1 kg/h \dot{m}_{steam,avg} = \frac{367.30\text{ kg}}{1.44\text{ h}} = 255.1\text{ kg/h} m ˙ s t e am , a vg = 1.44 h 367.30 kg = 255.1 kg/h
- 8. Common PE Exam Traps & Calculation Pitfalls
- Trap 1: Confusing Flowing Enthalpy with System Internal Energy
For a closed batch vessel or a variable-mass tank, the accumulation term is d ( m u ^ ) / d t d(m\hat{u})/dt d ( m u ^ ) / d t , not d ( m h ^ ) / d t d(m\hat{h})/dt d ( m h ^ ) / d t . Writing m C p d T / d t m C_p dT/dt m C p d T / d t for an ideal gas vessel results in an error of γ = 1.4 \gamma = 1.4 γ = 1.4 , because the closed mass accumulation is governed by C v C_v C v , whereas boundary flow is governed by C p C_p C p .
Trap 2: Assuming Constant Gravity Draining Flow
In gravity-drained tanks, flow rate diminishes continuously as liquid head drops ( V ˙ o u t ∝ h \dot{V}_{out} \propto \sqrt{h} V ˙ o u t ∝ h ). Calculating emptying time by dividing initial volume by initial volumetric flow ( t = V / V ˙ 0 t = V / \dot{V}_0 t = V / V ˙ 0 ) yields an answer that is exactly 50 % 50\% 50% of the true draining time! Always integrate Torricelli's equation.
Trap 3: Mixing Hydraulic and Thermal Time Constants
Do not confuse hydraulic residence time τ = V / V ˙ \tau = V/\dot{V} τ = V / V ˙ with thermal time constant τ t h = ( m C p ) / ( U A ) \tau_{th} = (m C_p)/(UA) τ t h = ( m C p ) / ( U A ) . For a continuous stirred tank with both flow and jacket heat exchange, the total temperature response combines both terms: 1 τ t o t a l = 1 τ f l o w + 1 τ t h \frac{1}{\tau_{total}} = \frac{1}{\tau_{flow}} + \frac{1}{\tau_{th}} τ t o t a l 1 = τ f l o w 1 + τ t h 1 .