Study guide
3.1 Fluid Statics, Pressure Measurement, and Manometry
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
3.1 Fluid Statics, Pressure Measurement, and Manometry
Key Takeaways Explain This Topic AI
The fundamental hydrostatic equation dP/dz = -rho*g dictates that pressure increases linearly with depth in an incompressible fluid and acts equally in all directions at a given depth.
Absolute pressure is the true thermodynamic pressure referenced to absolute zero (P_abs = P_gauge + P_atm); all vapor pressure, vacuum, and equation-of-state calculations require absolute units.
Differential manometry balances hydrostatic columns using the continuous fluid rule: start at one process tap, add rho g h when descending, subtract rho g h when ascending, and equate to the destination pressure.
When process fluid fills the manometer lead lines down to the sealing liquid, the measured differential pressure is Delta P = (rho_m - rho_f) g Delta h; omitting the process fluid density leads to massive design errors.
Inclined manometers amplify liquid displacement along an angle theta to the horizontal by 1/sin(theta), providing sub-millibar resolution for low-differential flue gas draft and cleanroom monitoring.
Last updated: September 2026
3.1 Fluid Statics, Pressure Measurement, and Manometry
Fluid statics is the branch of chemical engineering fluid mechanics that examines fluids at rest, where shear stresses are identically zero ( τ = 0 \tau = 0 τ = 0 ) and the stress state is purely isotropic. In stationary fluids, pressure acts perpendicularly on any boundary surface, regardless of surface orientation. Mastering fluid statics is essential for the NCEES PE Chemical exam, where questions routinely test hydrostatic tank loadings, level measurement transmitter calibrations, purge gas blanket pressures, and multi-fluid manometer calculations.
1. Fundamental Hydrostatic Equations
Consider a differential fluid element of dimensions d x dx d x , d y dy d y , and d z dz d z with density ρ \rho ρ subjected to the local gravitational field g g g . Setting the vertical forces into equilibrium yields the basic equation of fluid statics : d P d z = − ρ g = − γ \frac{dP}{dz} = -\rho g = -\gamma d z d P = − ρ g = − γ
where:
- P P P is local static pressure ( Pa \text{Pa} Pa or lb f / ft 2 \text{lb}_f/\text{ft}^2 lb f / ft 2 ),
- z z z is the vertical coordinate oriented positively upwards ( m \text{m} m or ft \text{ft} ft ),
ρ \rho ρ is fluid mass density ( kg/m 3 \text{kg/m}^3 kg/m 3 or lb m / ft 3 \text{lb}_m/\text{ft}^3 lb m / ft 3 ),
g g g is gravitational acceleration ( 9.80665 m/s 2 9.80665\text{ m/s}^2 9.80665 m/s 2 or 32.174 ft/s 2 32.174\text{ ft/s}^2 32.174 ft/s 2 ),
γ = ρ g \gamma = \rho g γ = ρ g is specific weight ( N/m 3 \text{N/m}^3 N/m 3 or lb f / ft 3 \text{lb}_f/\text{ft}^3 lb f / ft 3 in standard gravity).
For an incompressible fluid (where density ρ \rho ρ is constant throughout the depth h = z 1 − z 2 h = z_1 - z_2 h = z 1 − z 2 ): P 2 − P 1 = ρ g ( z 1 − z 2 ) = ρ g h = γ h P_2 - P_1 = \rho g (z_1 - z_2) = \rho g h = \gamma h P 2 − P 1 = ρ g ( z 1 − z 2 ) = ρ g h = γh
In US Customary units, remember to apply Newton's second law proportionality constant g c = 32.174 lb m ⋅ ft / ( lb f ⋅ s 2 ) g_c = 32.174\text{ lb}_m\cdot\text{ft}/(\text{lb}_f\cdot\text{s}^2) g c = 32.174 lb m ⋅ ft / ( lb f ⋅ s 2 ) : P 2 − P 1 = ρ g h g c P_2 - P_1 = \frac{\rho g h}{g_c} P 2 − P 1 = g c ρ g h
If g = g c g = g_c g = g c (standard terrestrial gravity), a fluid with density ρ [lb m / ft 3 ] \rho\text{ [lb}_m/\text{ft}^3\text{]} ρ [lb m / ft 3 ] exerts a pressure gradient of ρ / 144 psi per vertical foot \rho / 144\text{ psi per vertical foot} ρ /144 psi per vertical foot of depth.
2. Pressure Datums and Terminology
Pressure measurement requires an explicit reference datum. Misinterpreting gauge versus absolute pressure is among the most frequent error modes on the PE exam.
Term Symbol Definition & Reference Datum Typical Exam Context
Absolute Pressure P a b s P_{abs} P ab s Referenced to a perfect, absolute vacuum ( 0 psia 0\text{ psia} 0 psia or 0 kPa(a) 0\text{ kPa(a)} 0 kPa(a) ). Always positive. Required in thermodynamic equations of state, vapor pressure, vacuum column calculations, and NPSH equations.
Atmospheric Pressure P a t m P_{atm} P a t m The local ambient barometric pressure exerted by the terrestrial atmosphere ( 101.325 kPa 101.325\text{ kPa} 101.325 kPa or 14.696 psia 14.696\text{ psia} 14.696 psia at sea level). Fluctuates with site altitude and weather patterns; must be added to gauge readings to obtain absolute pressure.
Gauge Pressure P g a u g e P_{gauge} P g a ug e Pressure measured relative to the ambient atmospheric pressure: P g a u g e = P a b s − P a t m P_{gauge} = P_{abs} - P_{atm} P g a ug e = P ab s − P a t m . Read directly on Bourdon gauges, plant DCS displays, and vessel design specs (psig, barg, kPa(g)).
Vacuum Pressure P v a c P_{vac} P v a c Extent to which local pressure drops below ambient atmospheric: P v a c = P a t m − P a b s = − P g a u g e P_{vac} = P_{atm} - P_{abs} = -P_{gauge} P v a c = P a t m − P ab s = − P g a ug e . Vacuum crystallizers, condenser shells, and distillation column vacuum headers (inHg vacuum, torr).
Critical Unit Conversions at 4 °C / 60 °F
1 atm = 101.325 kPa = 1.01325 bar = 14.696 psia = 760 mmHg = 29.92 inHg = 33.91 ft H 2 O = 407.0 inH 2 O 1\text{ atm} = 101.325\text{ kPa} = 1.01325\text{ bar} = 14.696\text{ psia} = 760\text{ mmHg} = 29.92\text{ inHg} = 33.91\text{ ft H}_2\text{O} = 407.0\text{ inH}_2\text{O} 1 atm = 101.325 kPa = 1.01325 bar = 14.696 psia = 760 mmHg = 29.92 inHg = 33.91 ft H 2 O = 407.0 inH 2 O
1 psi = 6.89476 kPa = 2.307 ft H 2 O = 27.68 inH 2 O = 51.715 mmHg 1\text{ psi} = 6.89476\text{ kPa} = 2.307\text{ ft H}_2\text{O} = 27.68\text{ inH}_2\text{O} = 51.715\text{ mmHg} 1 psi = 6.89476 kPa = 2.307 ft H 2 O = 27.68 inH 2 O = 51.715 mmHg
1 bar = 100 kPa = 14.5038 psi = 0.98692 atm 1\text{ bar} = 100\text{ kPa} = 14.5038\text{ psi} = 0.98692\text{ atm} 1 bar = 100 kPa = 14.5038 psi = 0.98692 atm
3. Multi-Fluid Manometers and Differential Pressure Balances
Manometers quantify pressure differences by balancing the weight of one or more fluid columns. The governing operational rule is Pascal's principle combined with hydrostatic continuity: points at the same elevation in a continuous, homogeneous, stationary fluid possess identical pressures.
The Systematic "Manometer Walk" Algorithm
To write the governing hydrostatic equation for any complex, multi-leg manometer without algebraic error, follow this four-step procedure:
Select a starting boundary: Write down the known pressure at one terminus (e.g., P A P_A P A ).
Descend fluid columns: As you move downward through a fluid leg of vertical height h i h_i h i with density ρ i \rho_i ρ i , pressure increases . Add + ρ i g h i +\rho_i g h_i + ρ i g h i .
Ascend fluid columns: As you move upward through a fluid leg of vertical height h j h_j h j with density ρ j \rho_j ρ j , pressure decreases . Subtract − ρ j g h j -\rho_j g h_j − ρ j g h j .
Equate to destination boundary: Upon reaching the terminal tap or open interface, set the entire summation equal to the destination pressure (e.g., = P B = P_B = P B or = P a t m = P_{atm} = P a t m ).
The Differential U-Tube Manometer with Process Leads
In chemical process piping, a differential U-tube manometer measures pressure drop Δ P = P 1 − P 2 \Delta P = P_1 - P_2 Δ P = P 1 − P 2 across an orifice plate, venturi, or packed bed. The process fluid (density ρ f \rho_f ρ f ) fills the instrument tap leads above the manometer sealing fluid (density ρ m \rho_m ρ m , where ρ m > ρ f \rho_m > \rho_f ρ m > ρ f ): P 1 + ρ f g z 1 − ρ f g ( z 1 − z 2 ) − ρ m g Δ h + ρ f g ( z 1 − z 2 − Δ h ) = P 2 P_1 + \rho_f g z_1 - \rho_f g (z_1 - z_2) - \rho_m g \Delta h + \rho_f g (z_1 - z_2 - \Delta h) = P_2 P 1 + ρ f g z 1 − ρ f g ( z 1 − z 2 ) − ρ m g Δ h + ρ f g ( z 1 − z 2 − Δ h ) = P 2
Simplifying directly yields the standard differential manometry equation: P 1 − P 2 = ( ρ m − ρ f ) g Δ h P_1 - P_2 = (\rho_m - \rho_f) g \Delta h P 1 − P 2 = ( ρ m − ρ f ) g Δ h
Warning
Common Exam Trap: If you treat the manometer leads as containing only air or negligible vapor when they are actually flooded with liquid process solvent (e.g., water, benzene, heavy naphtha), you will mistakenly compute Δ P = ρ m g Δ h \Delta P = \rho_m g \Delta h Δ P = ρ m g Δ h . For a water-over-mercury manometer, omitting the process fluid density causes a ( 13.55 − 1.0 ) / 13.55 = 7.4 % (13.55 - 1.0)/13.55 = 7.4\% ( 13.55 − 1.0 ) /13.55 = 7.4% overstatement of differential pressure!
4. Inclined Manometers and Sensitivity Magnification
When measuring minute pressure differences—such as draft pressure inside a furnace firebox (typically − 0.1 to − 0.5 inH 2 O -0.1\text{ to }-0.5\text{ inH}_2\text{O} − 0.1 to − 0.5 inH 2 O ) or differential pressure across a HEPA filter—a standard vertical manometer produces meniscus displacements too tiny to read accurately. An inclined manometer magnifies this reading by canting one leg at an angle θ \theta θ relative to the horizontal.
The vertical hydrostatic elevation difference h h h is related to the linear scale displacement L L L along the tube bore by: h = L sin θ h = L \sin\theta h = L sin θ
Substituting this into the hydrostatic balance gives: Δ P = ρ m g L sin θ \Delta P = \rho_m g L \sin\theta Δ P = ρ m gL sin θ
The scale magnification factor is defined as: Magnification Factor = L h = 1 sin θ \text{Magnification Factor} = \frac{L}{h} = \frac{1}{\sin\theta} Magnification Factor = h L = sin θ 1
For an incline of θ = 5.74 ∘ \theta = 5.74^\circ θ = 5.7 4 ∘ , sin θ = 0.100 \sin\theta = 0.100 sin θ = 0.100 , yielding a 10 × 10\times 10 × magnification: a mere 0.10 in 0.10\text{ in} 0.10 in vertical water head produces a full 1.0 in 1.0\text{ in} 1.0 in readable travel along the inclined scale.
- 5. Hydrostatic Forces on Submerged Surfaces & Displacer Level Transmitters
- Forces on Submerged Planar Surfaces
The total resultant hydrostatic force F R F_R F R acting on a planar submerged surface of area A A A immersed in a liquid of density ρ \rho ρ is governed by the pressure at its area centroid ( h c h_c h c ): F R = P c A = ( ρ g h c ) A F_R = P_c A = (\rho g h_c) A F R = P c A = ( ρ g h c ) A
The resultant force acts not through the centroid, but through the center of pressure ( y c p y_{cp} y c p ), which always lies deeper than the centroid due to the trapezoidal pressure distribution: y c p = y c + I x x , c y c A y_{cp} = y_c + \frac{I_{xx,c}}{y_c A} y c p = y c + y c A I xx , c
where I x x , c I_{xx,c} I xx , c is the area moment of inertia about the horizontal centroidal axis, and y c y_c y c is the inclined distance from the liquid surface to the centroid.
Buoyancy and Displacer Level Measurement
Archimedes' principle states that any body completely or partially submerged in a fluid experiences an upward buoyant force F B F_B F B equal to the weight of the displaced fluid: F B = ρ f l u i d g V d i s p l a c e d F_B = \rho_{fluid} g V_{displaced} F B = ρ f l u i d g V d i s pl a ce d
In chemical reactors and distillation accumulators, liquid level is commonly measured using a torque tube displacer . A solid cylindrical rod of cross-sectional area A d A_d A d and mass m d m_d m d hangs inside a stilling well. As liquid level rises to submerge height h d h_d h d of the displacer, the net apparent weight W a p p W_{app} W a pp registered by the torque spring decreases linearly: W a p p = m d g − F B = m d g − ρ l i q g A d h d W_{app} = m_d g - F_B = m_d g - \rho_{liq} g A_d h_d W a pp = m d g − F B = m d g − ρ l i q g A d h d
For dual-liquid interfaces (e.g., water-hydrocarbon phase separation in an overhead decanter), two liquids of densities ρ 1 \rho_1 ρ 1 and ρ 2 \rho_2 ρ 2 submerge fractions h 1 h_1 h 1 and h 2 h_2 h 2 of the displacer: F B = g A d [ ρ 1 h 1 + ρ 2 h 2 ] F_B = g A_d [\rho_1 h_1 + \rho_2 h_2] F B = g A d [ ρ 1 h 1 + ρ 2 h 2 ]
6. Industrial Pressure Measurement Technologies
Instrument Operating Principle Range Advantages Limitations & Chemical Plant Precautions
U-Tube / Well Manometer Hydrostatic fluid column height balance 0 − 2 bar 0 - 2\text{ bar} 0 − 2 bar Primary standard; no calibration required; inexpensive Fragile glass; process fluid contamination; toxic sealing fluids (Hg banned in modern plants)
Bourdon Tube Gauge Elastic flattening of curved C-tube, spiral, or helix 0.5 − 7 , 000 bar 0.5 - 7,000\text{ bar} 0.5 − 7 , 000 bar Rugged; local mechanical readout; zero electrical power needed Subject to metal fatigue and vibration; requires chemical seal / diaphragm isolator for corrosive/slurry feeds
Diaphragm / dP Cell (Capacitive) Deflection of isolating diaphragm modulates capacitance 1 mbar − 100 bar 1\text{ mbar} - 100\text{ bar} 1 mbar − 100 bar High accuracy ( 0.05 % 0.05\% 0.05% ); rapid response; standard 4–20 mA / HART interface Temperature drift; diaphragm pinholes destroy fill fluid (silicone/fluorolube); impulse lines plug
Piezoresistive Strain Gauge Strain-induced resistance change in silicon bridge 0.1 − 1 , 000 bar 0.1 - 1,000\text{ bar} 0.1 − 1 , 000 bar Compact; excellent shock/vibration tolerance Sensitive to thermal transients; requires protective barrier fluids in aggressive chemical services
Bellows Gauge Axial expansion of corrugated metal cylinder 10 mbar − 5 bar 10\text{ mbar} - 5\text{ bar} 10 mbar − 5 bar High displacement force for low-pressure gas/vacuum High mechanical hysteresis; lower overpressure limits than diaphragms
- 7. Step-by-Step Worked Numerical Example
- Problem Statement
A differential mercury manometer ( ρ m = 13 , 550 kg/m 3 \rho_m = 13,550\text{ kg/m}^3 ρ m = 13 , 550 kg/m 3 ) is connected across an orifice meter installed in a vertical pipe carrying liquid kerosene ( S G = 0.820 SG = 0.820 SG = 0.820 , ρ k = 820 kg/m 3 \rho_k = 820\text{ kg/m}^3 ρ k = 820 kg/m 3 ) flowing downwards. The pressure taps A A A (upstream) and B B B (throat) are separated by a vertical distance of z A − z B = 0.450 m z_A - z_B = 0.450\text{ m} z A − z B = 0.450 m . The instrument impulse leads are completely flooded with kerosene. The mercury manometer indicates a deflection of Δ h = 260 mm = 0.260 m \Delta h = 260\text{ mm} = 0.260\text{ m} Δ h = 260 mm = 0.260 m , with the lower mercury meniscus residing on the side connected to tap A A A .
Calculate the differential static pressure Δ P = P A − P B \Delta P = P_A - P_B Δ P = P A − P B in units of kilopascals ( kPa \text{kPa} kPa ) and pounds per square inch ( psi \text{psi} psi ). ( g = 9.807 m/s 2 g = 9.807\text{ m/s}^2 g = 9.807 m/s 2 ). Tap A (z = +0.450 m)
- |
- | [Kerosene-filled lead]
- |
- Tap B (z = 0.000 m)
- |
- =========+=========
- | |
- | | (z2 = elevation of higher Hg meniscus)
- | v
- | [Hg] <-- meniscus 2 (connected to B)
- | |
- v | delta_h = 0.260 m
- [Hg] <-------------+ <-- meniscus 1 (connected to A)
- |_________________|
- Mercury Basin
- Solution
Step 1: Formulate the continuous hydrostatic balance. Start at Tap A A A at elevation z A z_A z A and write the manometer walk downwards to the lower mercury interface (Meniscus 1, at arbitrary elevation z 1 = 0 z_1 = 0 z 1 = 0 ): P meniscus 1 = P A + ρ k g ( z A − z 1 ) P_{\text{meniscus 1}} = P_A + \rho_k g (z_A - z_1) P meniscus 1 = P A + ρ k g ( z A − z 1 )
Cross through the continuous mercury leg to Meniscus 2 at elevation z 2 = z 1 + Δ h = 0.260 m z_2 = z_1 + \Delta h = 0.260\text{ m} z 2 = z 1 + Δ h = 0.260 m . Since we are moving upward through mercury, subtract the mercury column: P meniscus 2 = P meniscus 1 − ρ m g Δ h = P A + ρ k g ( z A − z 1 ) − ρ m g Δ h P_{\text{meniscus 2}} = P_{\text{meniscus 1}} - \rho_m g \Delta h = P_A + \rho_k g (z_A - z_1) - \rho_m g \Delta h P meniscus 2 = P meniscus 1 − ρ m g Δ h = P A + ρ k g ( z A − z 1 ) − ρ m g Δ h
Now ascend from Meniscus 2 through the kerosene-filled lead to Tap B B B at elevation z B = 0.450 m z_B = 0.450\text{ m} z B = 0.450 m . Subtract the kerosene column between z 2 z_2 z 2 and z B z_B z B : P B = P meniscus 2 − ρ k g ( z B − z 2 ) P_B = P_{\text{meniscus 2}} - \rho_k g (z_B - z_2) P B = P meniscus 2 − ρ k g ( z B − z 2 )
Step 2: Consolidate and isolate P A − P B P_A - P_B P A − P B . Substitute P meniscus 2 P_{\text{meniscus 2}} P meniscus 2 into the expression for P B P_B P B : P B = P A + ρ k g ( z A − z 1 ) − ρ m g Δ h − ρ k g ( z B − ( z 1 + Δ h ) ) P_B = P_A + \rho_k g (z_A - z_1) - \rho_m g \Delta h - \rho_k g (z_B - (z_1 + \Delta h)) P B = P A + ρ k g ( z A − z 1 ) − ρ m g Δ h − ρ k g ( z B − ( z 1 + Δ h ))
Expand the terms: P B = P A + ρ k g z A − ρ k g z 1 − ρ m g Δ h − ρ k g z B + ρ k g z 1 + ρ k g Δ h P_B = P_A + \rho_k g z_A - \rho_k g z_1 - \rho_m g \Delta h - \rho_k g z_B + \rho_k g z_1 + \rho_k g \Delta h P B = P A + ρ k g z A − ρ k g z 1 − ρ m g Δ h − ρ k g z B + ρ k g z 1 + ρ k g Δ h
Notice that the reference datum ρ k g z 1 \rho_k g z_1 ρ k g z 1 cancels completely: P B = P A + ρ k g ( z A − z B ) − ( ρ m − ρ k ) g Δ h P_B = P_A + \rho_k g (z_A - z_B) - (\rho_m - \rho_k) g \Delta h P B = P A + ρ k g ( z A − z B ) − ( ρ m − ρ k ) g Δ h
Rearranging for the pressure difference P A − P B P_A - P_B P A − P B : P A − P B = ( ρ m − ρ k ) g Δ h − ρ k g ( z A − z B ) P_A - P_B = (\rho_m - \rho_k) g \Delta h - \rho_k g (z_A - z_B) P A − P B = ( ρ m − ρ k ) g Δ h − ρ k g ( z A − z B )
Step 3: Insert numerical parameters.
Density difference: ( ρ m − ρ k ) = 13 , 550 − 820 = 12 , 730 kg/m 3 (\rho_m - \rho_k) = 13,550 - 820 = 12,730\text{ kg/m}^3 ( ρ m − ρ k ) = 13 , 550 − 820 = 12 , 730 kg/m 3
Mercury contribution: 12 , 730 kg/m 3 × 9.807 m/s 2 × 0.260 m = 32 , 459.7 Pa = 32.46 kPa 12,730\text{ kg/m}^3 \times 9.807\text{ m/s}^2 \times 0.260\text{ m} = 32,459.7\text{ Pa} = 32.46\text{ kPa} 12 , 730 kg/m 3 × 9.807 m/s 2 × 0.260 m = 32 , 459.7 Pa = 32.46 kPa
Elevation head of kerosene: ρ k g ( z A − z B ) = 820 kg/m 3 × 9.807 m/s 2 × 0.450 m = 3 , 618.8 Pa = 3.62 kPa \rho_k g (z_A - z_B) = 820\text{ kg/m}^3 \times 9.807\text{ m/s}^2 \times 0.450\text{ m} = 3,618.8\text{ Pa} = 3.62\text{ kPa} ρ k g ( z A − z B ) = 820 kg/m 3 × 9.807 m/s 2 × 0.450 m = 3 , 618.8 Pa = 3.62 kPa P A − P B = 32 , 459.7 Pa − 3 , 618.8 Pa = 28 , 840.9 Pa = 28.84 kPa P_A - P_B = 32,459.7\text{ Pa} - 3,618.8\text{ Pa} = 28,840.9\text{ Pa} = 28.84\text{ kPa} P A − P B = 32 , 459.7 Pa − 3 , 618.8 Pa = 28 , 840.9 Pa = 28.84 kPa
Convert to psi: P A − P B = 28 , 840.9 Pa × ( 1 psi 6 , 894.76 Pa ) = 4.183 psi P_A - P_B = 28,840.9\text{ Pa} \times \left(\frac{1\text{ psi}}{6,894.76\text{ Pa}}\right) = 4.183\text{ psi} P A − P B = 28 , 840.9 Pa × ( 6 , 894.76 Pa 1 psi ) = 4.183 psi
8. Common PE Exam Traps in Fluid Statics
Neglecting Seal-Leg Fluid Density: Assuming the fluid above the manometer liquid is air when it is process liquid. Always write ( ρ m − ρ f ) g Δ h (\rho_m - \rho_f) g \Delta h ( ρ m − ρ f ) g Δ h , not simply ρ m g Δ h \rho_m g \Delta h ρ m g Δ h .
Sign Errors Across Vertical Pipe Runs: When taps are at differing elevations, failing to add or subtract the fluid column ρ f g Δ z \rho_f g \Delta z ρ f g Δ z between the taps based on the directional orientation of the pipe leads.
Using Specific Gravity without Density Units: Multiplying directly by S G SG SG without multiplying by the base density of water ( ρ w = 1 , 000 kg/m 3 \rho_{w} = 1,000\text{ kg/m}^3 ρ w = 1 , 000 kg/m 3 or 62.4 lb m / ft 3 62.4\text{ lb}_m/\text{ft}^3 62.4 lb m / ft 3 ). Remember: S G SG SG is dimensionless.
Confusing Head with Pressure: Reporting head h h h in feet or meters when the problem asks for pressure in psi or kPa. Remember: Δ P = ρ g h \Delta P = \rho g h Δ P = ρ g h , so 10 ft of kerosene 10\text{ ft of kerosene} 10 ft of kerosene ( S G = 0.82 SG = 0.82 SG = 0.82 ) exerts only 3.55 psi 3.55\text{ psi} 3.55 psi , whereas 10 ft of water 10\text{ ft of water} 10 ft of water exerts 4.33 psi 4.33\text{ psi} 4.33 psi .