3.2 Incompressible Flow, Friction Factors, and the Moody Diagram
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
3.2 Incompressible Flow, Friction Factors, and the Moody Diagram
Key Takeaways Explain This Topic AI
The Mechanical Energy Balance (MEB) accounts for pressure, kinetic energy, potential energy, shaft work, and frictional dissipation along a streamline for constant-density fluids.
The Darcy-Weisbach friction factor is exactly four times the Fanning friction factor (f_D = 4*f_F); confusing these two conventions causes an immediate factor-of-four error in pressure drop calculations.
In laminar flow (Re < 2,100), the Hagen-Poiseuille relationship dictates that friction factor depends strictly on Reynolds number (f_D = 64/Re, f_F = 16/Re) and is completely independent of pipe roughness.
In the fully rough turbulent regime at high Reynolds numbers, the viscous sublayer is obliterated by wall roughness, causing the friction factor to become constant and depend solely on relative roughness (epsilon/D).
Pipe sizing requires actual internal diameter rather than nominal pipe size (NPS); because pressure drop scales inversely with diameter to the fifth power (Delta P proportional to D^-5), nominal rounding yields massive errors.
Last updated: September 2026
3.2 Incompressible Flow, Friction Factors, and the Moody Diagram
In chemical process plants, fluids are transported between unit operations—reactors, distillation columns, absorbers, and heat exchangers—through extensive piping networks. Designing piping, specifying pipe schedules, and selecting pump duty points require calculating frictional head loss. For liquids and gases experiencing small fractional pressure variations ( Δ P / P 1 < 0.10 \Delta P / P_1 < 0.10 Δ P / P 1 < 0.10 ), the fluid is modeled as incompressible (constant density ρ \rho ρ ).
1. The Mechanical Energy Balance (MEB)
Integrating the Navier-Stokes equations along a streamline for a steady-state, one-dimensional, incompressible fluid flow between upstream station 1 and downstream station 2 yields the Mechanical Energy Balance (MEB) : Δ P ρ + Δ ( v 2 ) 2 α + g Δ z + w ^ s + h ^ f = 0 \frac{\Delta P}{\rho} + \frac{\Delta(v^2)}{2\alpha} + g\Delta z + \hat{w}_s + \hat{h}_f = 0 ρ Δ P + 2 α Δ ( v 2 ) + g Δ z + w ^ s + h ^ f = 0
Expressed in the traditional head form (dividing through by g g g , where each term has units of length, such as meters or feet of flowing fluid): P 1 ρ g + α 1 v 1 2 2 g + z 1 + H p u m p = P 2 ρ g + α 2 v 2 2 2 g + z 2 + H t u r b i n e + h L \frac{P_1}{\rho g} + \frac{\alpha_1 v_1^2}{2g} + z_1 + H_{pump} = \frac{P_2}{\rho g} + \frac{\alpha_2 v_2^2}{2g} + z_2 + H_{turbine} + h_L ρ g P 1 + 2 g α 1 v 1 2 + z 1 + H p u m p = ρ g P 2 + 2 g α 2 v 2 2 + z 2 + H t u r bin e + h L
where:
P / ( ρ g ) P / (\rho g) P / ( ρ g ) is the static pressure head ( m \text{m} m or ft \text{ft} ft ),
α v 2 / ( 2 g ) \alpha v^2 / (2g) α v 2 / ( 2 g ) is the velocity head corrected for cross-sectional velocity profile,
z z z is the elevation head relative to a fixed datum,
H p u m p = − w ^ s / g H_{pump} = -\hat{w}_s / g H p u m p = − w ^ s / g is the total dynamic head added to the fluid by a pump,
H t u r b i n e = w ^ s , o u t / g H_{turbine} = \hat{w}_{s,out} / g H t u r bin e = w ^ s , o u t / g is shaft work extracted by a hydraulic turbine,
h L = h ^ f / g h_L = \hat{h}_f / g h L = h ^ f / g is the total head loss due to skin friction and minor fitting losses.
The Kinetic Energy Correction Factor ( α \alpha α )
Fluid velocity is not uniform across a pipe cross-section; it is zero at the wall (no-slip condition) and reaches a maximum at the pipe centerline. The kinetic energy correction factor α \alpha α reconciles the average velocity v = Q / A v = Q/A v = Q / A with the true kinetic energy flux ∫ 1 2 ρ u ( r ) 3 d A \int \frac{1}{2}\rho u(r)^3 dA ∫ 2 1 ρ u ( r ) 3 d A :
Laminar Flow (parabolic profile): α = 0.50 \alpha = 0.50 α = 0.50 (or 1 / 2 1/2 1/2 ).
Turbulent Flow (blunted 1 / 7 1/7 1/7 -th power profile): α ≈ 1.04 − 1.08 \alpha \approx 1.04 - 1.08 α ≈ 1.04 − 1.08 , universally taken as α = 1.0 \alpha = 1.0 α = 1.0 in engineering calculations.
2. Dimensionless Flow Regimes and the Reynolds Number
The flow regime in a circular conduit of inside diameter D D D is governed by the Reynolds number ( R e Re R e ), representing the ratio of inertial forces to viscous forces: R e = ρ v D μ = v D ν = 4 m ˙ π D μ = 4 ρ Q π D μ Re = \frac{\rho v D}{\mu} = \frac{v D}{\nu} = \frac{4 \dot{m}}{\pi D \mu} = \frac{4 \rho Q}{\pi D \mu} R e = μ ρ v D = ν v D = π D μ 4 m ˙ = π D μ 4 ρQ
where μ \mu μ is dynamic shear viscosity ( Pa ⋅ s \text{Pa}\cdot\text{s} Pa ⋅ s or lb m / ( ft ⋅ s ) \text{lb}_m/(\text{ft}\cdot\text{s}) lb m / ( ft ⋅ s ) ), ν = μ / ρ \nu = \mu / \rho ν = μ / ρ is kinematic viscosity ( m 2 / s \text{m}^2/\text{s} m 2 / s or ft 2 / s \text{ft}^2/\text{s} ft 2 / s ), and m ˙ = ρ Q \dot{m} = \rho Q m ˙ = ρQ is mass flow rate.
Regimes in Circular Pipes
Laminar Regime ( R e < 2 , 100 Re < 2,100 R e < 2 , 100 ): Viscous forces dominate. Fluid particles move in parallel concentric laminae without macroscopic mixing or radial velocity fluctuations.
Transition Regime ( 2 , 100 ≤ R e ≤ 4 , 000 2,100 \le Re \le 4,000 2 , 100 ≤ R e ≤ 4 , 000 ): Unstable flow. Intermittent turbulent bursts occur; flow fluctuates unpredictably between laminar and turbulent states.
Turbulent Regime ( R e > 4 , 000 Re > 4,000 R e > 4 , 000 ): Inertial forces dominate. Chaotic, three-dimensional turbulent eddies enhance radial momentum transfer, producing a flattened core velocity profile bounded by a thin laminar/viscous sublayer at the pipe wall.
3. The Great Friction Factor Divide: Darcy-Weisbach vs. Fanning
A paramount source of confusion on the NCEES PE Chemical exam is the distinction between the Darcy-Weisbach friction factor ( f D f_D f D , also designated as the Moody friction factor f f f ) and the Fanning friction factor ( f F f_F f F ). Both are dimensionless, but their fundamental definitions differ by a factor of 4.
Attribute Darcy-Weisbach (Moody) Friction Factor ( f D f_D f D ) Fanning Friction Factor ( f F f_F f F )
Primary Disciplines Civil, Mechanical, ASME, Crane TP 410, NCEES Handbook Chemical Engineering (Bird-Stewart-Lightfoot, Perry's Handbook)
Fundamental Definition Defined directly in terms of bulk velocity head: h f = f D L D v 2 2 g h_f = f_D \frac{L}{D} \frac{v^2}{2g} h f = f D D L 2 g v 2 Defined in terms of wall shear stress: τ w = f F ( 1 2 ρ v 2 ) \tau_w = f_F \left(\frac{1}{2}\rho v^2\right) τ w = f F ( 2 1 ρ v 2 )
Pressure Drop Formula Δ P f = f D L D ( ρ v 2 2 ) \Delta P_f = f_D \frac{L}{D} \left(\frac{\rho v^2}{2}\right) Δ P f = f D D L ( 2 ρ v 2 ) Δ P f = 4 f F L D ( ρ v 2 2 ) \Delta P_f = 4 f_F \frac{L}{D} \left(\frac{\rho v^2}{2}\right) Δ P f = 4 f F D L ( 2 ρ v 2 )
Laminar Flow Formula f D = 64 R e f_D = \frac{64}{Re} f D = R e 64 f F = 16 R e f_F = \frac{16}{Re} f F = R e 16
Conversion Rule f D = 4 f F f_D = 4 f_F f D = 4 f F f F = f D 4 f_F = \frac{f_D}{4} f F = 4 f D
Important
Always verify the friction factor identity before calculating! Examine the laminar formula on the chart or equation sheet. If laminar flow is represented by 64 / R e 64/Re 64/ R e , it is Darcy-Weisbach ( f D f_D f D ). If it is 16 / R e 16/Re 16/ R e , it is Fanning ( f F f_F f F ).
4. Laminar Flow: The Hagen-Poiseuille Equation
For laminar flow in a horizontal cylindrical pipe, momentum conservation yields a parabolic velocity profile: u ( r ) = 2 v [ 1 − ( r R ) 2 ] = u m a x [ 1 − ( r R ) 2 ] u(r) = 2 v \left[1 - \left(\frac{r}{R}\right)^2\right] = u_{max} \left[1 - \left(\frac{r}{R}\right)^2\right] u ( r ) = 2 v [ 1 − ( R r ) 2 ] = u ma x [ 1 − ( R r ) 2 ]
Notice that the centerline velocity is exactly twice the cross-sectional average velocity: u m a x = 2 v u_{max} = 2 v u ma x = 2 v .
Integrating the shear stress across the radius leads to the analytical Hagen-Poiseuille equation : Δ P = 128 μ L Q π D 4 = 32 μ v L D 2 \Delta P = \frac{128 \mu L Q}{\pi D^4} = \frac{32 \mu v L}{D^2} Δ P = π D 4 128 μL Q = D 2 32 μvL
Expressed in head loss form: h f = 32 μ v L ρ g D 2 = ( 64 R e ) L D v 2 2 g h_f = \frac{32 \mu v L}{\rho g D^2} = \left(\frac{64}{Re}\right) \frac{L}{D} \frac{v^2}{2g} h f = ρ g D 2 32 μvL = ( R e 64 ) D L 2 g v 2
Key physical takeaway: In laminar flow, frictional pressure drop is directly proportional to velocity ( Δ P ∝ v \Delta P \propto v Δ P ∝ v ) and viscosity ( Δ P ∝ μ \Delta P \propto \mu Δ P ∝ μ ), and inversely proportional to diameter to the fourth power ( Δ P ∝ D − 4 \Delta P \propto D^{-4} Δ P ∝ D − 4 ). Wall roughness has zero effect on laminar friction because surface asperities remain buried within the streamlined laminae.
5. Turbulent Flow Correlations and the Moody Diagram
In turbulent flow, analytical integration is precluded by Reynolds shear stresses ( − ρ u ′ v ′ ‾ -\rho \overline{u'v'} − ρ u ′ v ′ ). Friction factors are determined semi-empirically based on R e Re R e and relative roughness ( ε / D \varepsilon / D ε / D ), where ε \varepsilon ε is the absolute equivalent sand-grain roughness of the pipe material.
Typical Absolute Roughness Values ( ε \varepsilon ε )
Drawn copper, glass, plastic (PVC, HDPE): ε = 0.0015 mm = 0.000005 ft \varepsilon = 0.0015\text{ mm} = 0.000005\text{ ft} ε = 0.0015 mm = 0.000005 ft
Commercial carbon steel, welded steel: ε = 0.045 − 0.046 mm = 0.00015 ft \varepsilon = 0.045 - 0.046\text{ mm} = 0.00015\text{ ft} ε = 0.045 − 0.046 mm = 0.00015 ft
Galvanized iron: ε = 0.15 mm = 0.0005 ft \varepsilon = 0.15\text{ mm} = 0.0005\text{ ft} ε = 0.15 mm = 0.0005 ft
- Cast iron: ε = 0.26 mm = 0.00085 ft \varepsilon = 0.26\text{ mm} = 0.00085\text{ ft} ε = 0.26 mm = 0.00085 ft
- Governing Turbulent Correlations (Darcy Form)
The Implicit Colebrook-White Equation (Moody Chart Basis): 1 f D = − 2.0 log 10 ( ε / D 3.7 + 2.51 R e f D ) \frac{1}{\sqrt{f_D}} = -2.0 \log_{10} \left( \frac{\varepsilon / D}{3.7} + \frac{2.51}{Re \sqrt{f_D}} \right) f D 1 = − 2.0 lo g 10 ( 3.7 ε / D + R e f D 2.51 )
The Explicit Haaland Equation (Recommended for Rapid PE Solving): Developed by S. E. Haaland in 1983, this non-iterative formula provides accuracy within ± 1.5 % \pm 1.5\% ± 1.5% of Colebrook-White for 4 , 000 ≤ R e ≤ 10 8 4,000 \le Re \le 10^8 4 , 000 ≤ R e ≤ 1 0 8 and 10 − 6 ≤ ε / D ≤ 0.05 10^{-6} \le \varepsilon/D \le 0.05 1 0 − 6 ≤ ε / D ≤ 0.05 : 1 f D = − 1.8 log 10 [ ( ε / D 3.7 ) 1.11 + 6.9 R e ] \frac{1}{\sqrt{f_D}} = -1.8 \log_{10} \left[ \left(\frac{\varepsilon / D}{3.7}\right)^{1.11} + \frac{6.9}{Re} \right] f D 1 = − 1.8 lo g 10 [ ( 3.7 ε / D ) 1.11 + R e 6.9 ]
The Blasius Correlation (Smooth Pipes, Low R e Re R e ): Applicable for hydraulically smooth pipes ( ε / D ≈ 0 \varepsilon / D \approx 0 ε / D ≈ 0 ) in the range 4 , 000 ≤ R e ≤ 100 , 000 4,000 \le Re \le 100,000 4 , 000 ≤ R e ≤ 100 , 000 : f D = 0.3164 R e − 0.25 ⟺ f F = 0.0791 R e − 0.25 f_D = 0.3164 Re^{-0.25} \quad \Longleftrightarrow \quad f_F = 0.0791 Re^{-0.25} f D = 0.3164 R e − 0.25 ⟺ f F = 0.0791 R e − 0.25
The Fully Rough (Wholly Turbulent) Regime: At sufficiently high Reynolds numbers (the right side of the Moody diagram), the laminar sublayer becomes thinner than the roughness asperities. Form drag over the asperities completely overwhelms viscous shear, making the friction factor independent of R e Re R e (the von Kármán equation ): 1 f D = − 2.0 log 10 ( ε / D 3.7 ) = 1.14 − 2 log 10 ( ε D ) \frac{1}{\sqrt{f_D}} = -2.0 \log_{10} \left(\frac{\varepsilon / D}{3.7}\right) = 1.14 - 2 \log_{10} \left(\frac{\varepsilon}{D}\right) f D 1 = − 2.0 lo g 10 ( 3.7 ε / D ) = 1.14 − 2 lo g 10 ( D ε )
In this regime, Δ P \Delta P Δ P is strictly proportional to v 2 v^2 v 2 (or Q 2 Q^2 Q 2 ).
The Universal Churchill Correlation: Valid across all regimes (laminar, transition, turbulent) without piecewise discontinuity: f D = 8 [ ( 8 R e ) 12 + 1 ( A + B ) 1.5 ] 1 / 12 f_D = 8 \left[ \left(\frac{8}{Re}\right)^{12} + \frac{1}{(A + B)^{1.5}} \right]^{1/12} f D = 8 [ ( R e 8 ) 12 + ( A + B ) 1.5 1 ] 1/12
where A = [ − 2.457 ln ( ( 7 R e ) 0.9 + 0.27 ε D ) ] 16 A = \left[-2.457 \ln\left( \left(\frac{7}{Re}\right)^{0.9} + 0.27 \frac{\varepsilon}{D} \right)\right]^{16} A = [ − 2.457 ln ( ( R e 7 ) 0.9 + 0.27 D ε ) ] 16 and B = ( 37 , 530 R e ) 16 B = \left(\frac{37,530}{Re}\right)^{16} B = ( R e 37 , 530 ) 16 .
6. Hydraulic Diameter for Non-Circular Conduits
To apply circular pipe friction charts and equations to non-circular passages (e.g., heat exchanger annuli, rectangular ducts, jacketed vessels), define the hydraulic diameter ( D H D_H D H ): D H = 4 A c P w D_H = \frac{4 A_c}{P_w} D H = P w 4 A c
where A c A_c A c is cross-sectional flow area and P w P_w P w is the wetted perimeter (the boundary perimeter in direct contact with the flowing fluid).
Concentric Annulus (Outer ID = D o D_o D o , Inner OD = D i D_i D i ): A c = π 4 ( D o 2 − D i 2 ) , P w = π ( D o + D i ) ⟹ D H = 4 π 4 ( D o 2 − D i 2 ) π ( D o + D i ) = D o − D i A_c = \frac{\pi}{4}(D_o^2 - D_i^2), \quad P_w = \pi(D_o + D_i) \implies D_H = \frac{4 \frac{\pi}{4}(D_o^2 - D_i^2)}{\pi(D_o + D_i)} = D_o - D_i A c = 4 π ( D o 2 − D i 2 ) , P w = π ( D o + D i ) ⟹ D H = π ( D o + D i ) 4 4 π ( D o 2 − D i 2 ) = D o − D i
Rectangular Duct (width a a a , height b b b ): A c = a b , P w = 2 ( a + b ) ⟹ D H = 4 a b 2 ( a + b ) = 2 a b a + b A_c = a b, \quad P_w = 2(a + b) \implies D_H = \frac{4 a b}{2(a + b)} = \frac{2 a b}{a + b} A c = ab , P w = 2 ( a + b ) ⟹ D H = 2 ( a + b ) 4 ab = a + b 2 ab
- 7. Step-by-Step Worked Numerical Example
- Problem Statement
Liquid toluene at 25 ∘ C 25^\circ\text{C} 2 5 ∘ C (density ρ = 862 kg/m 3 \rho = 862\text{ kg/m}^3 ρ = 862 kg/m 3 , absolute viscosity μ = 0.560 cP = 0.560 × 10 − 3 Pa ⋅ s \mu = 0.560\text{ cP} = 0.560 \times 10^{-3}\text{ Pa}\cdot\text{s} μ = 0.560 cP = 0.560 × 1 0 − 3 Pa ⋅ s ) is pumped through a horizontal 150 m 150\text{ m} 150 m run of commercial carbon steel pipe ( ε = 0.046 mm \varepsilon = 0.046\text{ mm} ε = 0.046 mm ) at a volumetric flow rate of Q = 38.0 m 3 / h Q = 38.0\text{ m}^3/\text{h} Q = 38.0 m 3 / h . The piping is nominal 3-inch Schedule 40.
From standard pipe schedule tables:
Nominal size: 3 in 3\text{ in} 3 in
Actual inside diameter: D = 3.068 in = 0.07793 m D = 3.068\text{ in} = 0.07793\text{ m} D = 3.068 in = 0.07793 m
Internal cross-sectional area: A c = 0.004769 m 2 A_c = 0.004769\text{ m}^2 A c = 0.004769 m 2
Calculate:
The mean flow velocity v v v and Reynolds number R e Re R e .
The Darcy-Weisbach friction factor f D f_D f D using the Haaland equation.
The total frictional head loss h f h_f h f in meters of toluene.
The pressure drop Δ P f \Delta P_f Δ P f in kPa \text{kPa} kPa and psi \text{psi} psi .
Solution
Step 1: Calculate velocity and Reynolds number. Convert flow rate to SI base units: Q = 38.0 m 3 / h 3 , 600 s/h = 0.010556 m 3 / s Q = \frac{38.0\text{ m}^3/\text{h}}{3,600\text{ s/h}} = 0.010556\text{ m}^3/\text{s} Q = 3 , 600 s/h 38.0 m 3 / h = 0.010556 m 3 / s
Mean velocity: v = Q A c = 0.010556 m 3 / s 0.004769 m 2 = 2.2135 m/s v = \frac{Q}{A_c} = \frac{0.010556\text{ m}^3/\text{s}}{0.004769\text{ m}^2} = 2.2135\text{ m/s} v = A c Q = 0.004769 m 2 0.010556 m 3 / s = 2.2135 m/s
Reynolds number: R e = ρ v D μ = 862 kg/m 3 × 2.2135 m/s × 0.07793 m 0.560 × 10 − 3 Pa ⋅ s = 148.69 0.000560 = 265 , 520 Re = \frac{\rho v D}{\mu} = \frac{862\text{ kg/m}^3 \times 2.2135\text{ m/s} \times 0.07793\text{ m}}{0.560 \times 10^{-3}\text{ Pa}\cdot\text{s}} = \frac{148.69}{0.000560} = 265,520 R e = μ ρ v D = 0.560 × 1 0 − 3 Pa ⋅ s 862 kg/m 3 × 2.2135 m/s × 0.07793 m = 0.000560 148.69 = 265 , 520
Since R e = 2.66 × 10 5 > 4 , 000 Re = 2.66 \times 10^5 > 4,000 R e = 2.66 × 1 0 5 > 4 , 000 , the flow is fully turbulent.
Step 2: Determine the Darcy friction factor using Haaland's formula. Relative roughness: ε D = 0.046 mm 77.93 mm = 0.0005903 \frac{\varepsilon}{D} = \frac{0.046\text{ mm}}{77.93\text{ mm}} = 0.0005903 D ε = 77.93 mm 0.046 mm = 0.0005903
Applying the Haaland equation: 1 f D = − 1.8 log 10 [ ( 0.0005903 3.7 ) 1.11 + 6.9 265 , 520 ] \frac{1}{\sqrt{f_D}} = -1.8 \log_{10} \left[ \left(\frac{0.0005903}{3.7}\right)^{1.11} + \frac{6.9}{265,520} \right] f D 1 = − 1.8 lo g 10 [ ( 3.7 0.0005903 ) 1.11 + 265 , 520 6.9 ]
Evaluate intermediate terms: ε / D 3.7 = 0.0005903 3.7 = 1.5954 × 10 − 4 \frac{\varepsilon / D}{3.7} = \frac{0.0005903}{3.7} = 1.5954 \times 10^{-4} 3.7 ε / D = 3.7 0.0005903 = 1.5954 × 1 0 − 4 ( 1.5954 × 10 − 4 ) 1.11 = 6.307 × 10 − 5 \left(1.5954 \times 10^{-4}\right)^{1.11} = 6.307 \times 10^{-5} ( 1.5954 × 1 0 − 4 ) 1.11 = 6.307 × 1 0 − 5 6.9 R e = 6.9 265 , 520 = 2.5986 × 10 − 5 \frac{6.9}{Re} = \frac{6.9}{265,520} = 2.5986 \times 10^{-5} R e 6.9 = 265 , 520 6.9 = 2.5986 × 1 0 − 5 Bracket Sum = 6.307 × 10 − 5 + 2.599 × 10 − 5 = 8.906 × 10 − 5 \text{Bracket Sum} = 6.307 \times 10^{-5} + 2.599 \times 10^{-5} = 8.906 \times 10^{-5} Bracket Sum = 6.307 × 1 0 − 5 + 2.599 × 1 0 − 5 = 8.906 × 1 0 − 5 log 10 ( 8.906 × 10 − 5 ) = − 4.0503 \log_{10}\left(8.906 \times 10^{-5}\right) = -4.0503 lo g 10 ( 8.906 × 1 0 − 5 ) = − 4.0503 1 f D = − 1.8 × ( − 4.0503 ) = 7.2906 \frac{1}{\sqrt{f_D}} = -1.8 \times (-4.0503) = 7.2906 f D 1 = − 1.8 × ( − 4.0503 ) = 7.2906 f D = 1 7.2906 = 0.13716 \sqrt{f_D} = \frac{1}{7.2906} = 0.13716 f D = 7.2906 1 = 0.13716 f D = ( 0.13716 ) 2 = 0.01881 f_D = (0.13716)^2 = 0.01881 f D = ( 0.13716 ) 2 = 0.01881
(Note: If using the Fanning convention, f F = f D / 4 = 0.00470 f_F = f_D / 4 = 0.00470 f F = f D /4 = 0.00470 .)
Step 3: Calculate frictional head loss ( h f h_f h f ). Using the Darcy-Weisbach head loss equation: h f = f D L D v 2 2 g = 0.01881 × ( 150 m 0.07793 m ) × ( 2.2135 m/s ) 2 2 × 9.807 m/s 2 h_f = f_D \frac{L}{D} \frac{v^2}{2g} = 0.01881 \times \left(\frac{150\text{ m}}{0.07793\text{ m}}\right) \times \frac{(2.2135\text{ m/s})^2}{2 \times 9.807\text{ m/s}^2} h f = f D D L 2 g v 2 = 0.01881 × ( 0.07793 m 150 m ) × 2 × 9.807 m/s 2 ( 2.2135 m/s ) 2 h f = 0.01881 × 1 , 924.8 × 4.8996 19.614 = 36.205 × 0.2498 = 9.044 m of toluene h_f = 0.01881 \times 1,924.8 \times \frac{4.8996}{19.614} = 36.205 \times 0.2498 = 9.044\text{ m of toluene} h f = 0.01881 × 1 , 924.8 × 19.614 4.8996 = 36.205 × 0.2498 = 9.044 m of toluene
Step 4: Calculate frictional pressure drop ( Δ P f \Delta P_f Δ P f ). Δ P f = ρ g h f = 862 kg/m 3 × 9.807 m/s 2 × 9.044 m = 76 , 450 Pa = 76.45 kPa \Delta P_f = \rho g h_f = 862\text{ kg/m}^3 \times 9.807\text{ m/s}^2 \times 9.044\text{ m} = 76,450\text{ Pa} = 76.45\text{ kPa} Δ P f = ρ g h f = 862 kg/m 3 × 9.807 m/s 2 × 9.044 m = 76 , 450 Pa = 76.45 kPa
Convert to psi: Δ P f = 76.45 kPa × ( 1 psi 6.89476 kPa ) = 11.09 psi \Delta P_f = 76.45\text{ kPa} \times \left(\frac{1\text{ psi}}{6.89476\text{ kPa}}\right) = 11.09\text{ psi} Δ P f = 76.45 kPa × ( 6.89476 kPa 1 psi ) = 11.09 psi
8. Common PE Exam Traps in Incompressible Flow
The Factor-of-Four Blunder: Using Fanning friction factor f F f_F f F in Darcy's equation Δ P = f ( L / D ) ( ρ v 2 / 2 ) \Delta P = f (L/D) (\rho v^2 / 2) Δ P = f ( L / D ) ( ρ v 2 /2 ) without the factor of 4, producing an answer that is exactly 25 % 25\% 25% of the true value.
Nominal vs. Actual Pipe Diameter: Using 3.00 in 3.00\text{ in} 3.00 in instead of 3.068 in 3.068\text{ in} 3.068 in for Schedule 40 pipe. Because pressure drop scales as D − 5 D^{-5} D − 5 , an error of just 2.3 % 2.3\% 2.3% in diameter creates a ( 3.00 / 3.068 ) − 5 − 1 = + 11.8 % (3.00/3.068)^{-5} - 1 = +11.8\% ( 3.00/3.068 ) − 5 − 1 = + 11.8% error in computed pressure drop!
Omitting the Kinetic Energy Correction Factor in Laminar Balance: When solving laminar energy balances where upstream and downstream velocities differ, using α = 1.0 \alpha = 1.0 α = 1.0 instead of α = 0.50 \alpha = 0.50 α = 0.50 .
Assuming Roughness Always Matters: In laminar flow ( R e < 2 , 100 Re < 2,100 R e < 2 , 100 ), wall roughness ε \varepsilon ε is completely irrelevant. Do not waste time looking up ε / D \varepsilon / D ε / D if R e < 2 , 100 Re < 2,100 R e < 2 , 100 .