Study guide

3.4 Pumps, Compressors, and NPSH Calculations

PE Chemical Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the PE Chemical Exam How to Use This Guide and the NCEES Handbook

2 Chapter 1: Material Balances & Flowsheet Calculations

1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations

3 Chapter 2: Energy Balances & Thermochemistry

2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances

4 Chapter 3: Fluid Statics & Incompressible Pipe Flow

3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations

5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow

4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up

6 Chapter 5: Thermodynamic Laws & Fundamental Relations

5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations

7 Chapter 6: Real Gases & Equations of State

6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions

8 Chapter 7: Phase & Chemical Reaction Equilibria

7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation

9 Chapter 8: Heat Transfer Mechanisms & Conduction

8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange

10 Chapter 9: Heat Exchanger Design & Phase Change

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances

11 Chapter 10: Mass Transfer Fundamentals & Diffusion

10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)

12 Chapter 11: Distillation Operations

11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components

13 Chapter 12: Rate-Controlled & Equilibrium Separations

12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations

14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors

13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations

15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis

14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models

16 Chapter 15: Physical & Transport Properties of Fluids

15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles

17 Chapter 16: Materials of Construction & Corrosion

16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention

18 Chapter 17: Process Safety & Pressure Relief Systems

17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment

19 Chapter 18: Process Control & Engineering Economics

18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems

20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance

19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation

21 Chapter 20: Plant Operation, Reliability & Continuous Improvement

20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting

3.4 Pumps, Compressors, and NPSH Calculations

Key Takeaways Explain This Topic AI

Total Dynamic Head (TDH) represents the net mechanical energy per unit weight imparted to fluid by the pump: TDH = (P_d - P_s)/(rho*g) + (z_d - z_s) + (v_d² - v_s²)/(2g).

Centrifugal pump affinity laws state that flow varies linearly with rotational speed or diameter (Q proportional to N, D), head varies quadratically (H proportional to N², D²), and power varies cubically (P proportional to N³, D³).

Net Positive Suction Head Available (NPSHA) must always be computed in absolute pressure head: NPSHA = (P_source,abs - P_vp)/(rho*g) + z_s - h_f,suct; using gauge pressure will cause catastrophic design errors.

For boiling or saturated liquids at their bubble point in closed vessels (reboilers, deaerators, accumulators), P_source,abs = P_vp identically, reducing the available head to NPSHA = z_s - h_f,suct; the liquid must be elevated above the pump centerline.

To avoid cavitation, vibration, and impeller destruction, process design standards (such as API 610) mandate that NPSHA exceed NPSHR by an engineering margin of at least 2.0–3.0 ft (0.6–1.0 m) or an NPSHA/NPSHR ratio >= 1.2.

Last updated: September 2026

3.4 Pumps, Compressors, and NPSH Calculations

Pumps and compressors add mechanical energy to fluids to overcome friction, increase elevation, or raise pressure. On the NCEES PE Chemical exam, fluid machinery questions emphasize centrifugal pump hydraulics, affinity laws, motor sizing, and above all, Net Positive Suction Head (NPSH) calculations to prevent cavitation.

1. Machinery Classification: Centrifugal vs. Positive Displacement

Process pumps fall into two major thermodynamic categories:

Kinetic (Centrifugal) Pumps

Centrifugal pumps impart kinetic energy to the fluid using a high-speed rotating impeller. As fluid exits the impeller vanes radially or axially, it enters a diffusing volute casing where velocity converts to static pressure. Centrifugal pumps are the workhorses of the chemical industry, favored for continuous, non-pulsating delivery of low-viscosity fluids.

Positive Displacement (PD) Pumps

PD pumps trap a fixed volume of fluid inside an enclosed chamber and physically displace it against discharge pressure using reciprocating pistons/plungers or rotating gears, lobes, or screws.

Key Distinction: A centrifugal pump produces a variable flow rate depending on discharge pressure ( H H H vs. Q Q Q curve). A PD pump delivers a virtually constant volumetric flow rate regardless of discharge pressure, limited only by drive motor torque and casing burst strength. For this reason, PD pumps must always be protected by a dedicated pressure relief valve (PRV) installed upstream of the first discharge block valve.

2. Total Dynamic Head (TDH) and Pump Power

Applying the Mechanical Energy Balance across a pump from suction flange ( s s s ) to discharge flange ( d d d ) yields the Total Dynamic Head (TDH) imparted to the fluid: T D H = H = ( P d − P s ρ g ) + ( z d − z s ) + ( v d 2 − v s 2 2 g ) TDH = H = \left(\frac{P_d - P_s}{\rho g}\right) + (z_d - z_s) + \left(\frac{v_d^2 - v_s^2}{2g}\right) T DH = H = ( ρ g P d ​ − P s ​ ​ ) + ( z d ​ − z s ​ ) + ( 2 g v d 2 ​ − v s 2 ​ ​ )

If expressed between the free surface of an upstream supply vessel ( 1 1 1 ) and a downstream destination vessel ( 2 2 2 ): T D H = ( P 2 , a b s − P 1 , a b s ρ g ) + ( z 2 − z 1 ) + h f , t o t a l TDH = \left(\frac{P_{2,abs} - P_{1,abs}}{\rho g}\right) + (z_2 - z_1) + h_{f,total} T DH = ( ρ g P 2 , ab s ​ − P 1 , ab s ​ ​ ) + ( z 2 ​ − z 1 ​ ) + h f , t o t a l ​

where h f , t o t a l = h f , s u c t + h f , d i s c h h_{f,total} = h_{f,suct} + h_{f,disch} h f , t o t a l ​ = h f , s u c t ​ + h f , d i sc h ​ is the sum of all piping and minor losses in the suction and discharge lines.

Power and Efficiency Formulations

Water (Hydraulic) Horsepower ( W H P WHP W H P ): The theoretical mechanical power transferred to the fluid: W H P = m ˙ g ( T D H ) = ρ g Q ( T D H ) = Q Δ P WHP = \dot{m} g (TDH) = \rho g Q (TDH) = Q \Delta P W H P = m ˙ g ( T DH ) = ρ g Q ( T DH ) = Q Δ P

In US Customary units ( Q Q Q in gpm, T D H TDH T DH in ft, S G SG SG relative to water at 60 ∘ F 60^\circ\text{F} 6 0 ∘ F ): W H P = Q × T D H × S G 3 , 960 = Q × Δ P [psi] 1 , 714 WHP = \frac{Q \times TDH \times SG}{3,960} = \frac{Q \times \Delta P\text{ [psi]}}{1,714} W H P = 3 , 960 Q × T DH × SG ​ = 1 , 714 Q × Δ P [psi] ​

Brake Horsepower ( B H P BHP B H P ): The actual shaft power required from the electric motor or turbine, accounting for pump hydraulic, mechanical, and volumetric efficiency η p \eta_p η p ​ : B H P = W H P η p = Q × T D H × S G 3 , 960 × η p BHP = \frac{WHP}{\eta_p} = \frac{Q \times TDH \times SG}{3,960 \times \eta_p} B H P = η p ​ W H P ​ = 3 , 960 × η p ​ Q × T DH × SG ​

Electrical Motor Power ( P e l e c P_{elec} P e l ec ​ ): Factoring in driver/motor electrical efficiency η m \eta_m η m ​ : P e l e c = B H P η m = W H P η p η m = W H P η o v e r a l l P_{elec} = \frac{BHP}{\eta_m} = \frac{WHP}{\eta_p \eta_m} = \frac{WHP}{\eta_{overall}} P e l ec ​ = η m ​ B H P ​ = η p ​ η m ​ W H P ​ = η o v er a ll ​ W H P ​

3. System Head Curves and Operating Duty Points

A piping system presents a system head curve H s y s ( Q ) H_{sys}(Q) H sys ​ ( Q ) composed of static head and friction: H s y s ( Q ) = H s t a t i c + C s y s Q 2 = [ Δ P s t a t i c ρ g + Δ z ] + [ ∑ ( f L D + K ) 1 2 g A c 2 ] Q 2 H_{sys}(Q) = H_{static} + C_{sys} Q^2 = \left[ \frac{\Delta P_{static}}{\rho g} + \Delta z \right] + \left[ \sum \left(f \frac{L}{D} + K\right) \frac{1}{2 g A_c^2} \right] Q^2 H sys ​ ( Q ) = H s t a t i c ​ + C sys ​ Q 2 = [ ρ g Δ P s t a t i c ​ ​ + Δ z ] + [ ∑ ( f D L ​ + K ) 2 g A c 2 ​ 1 ​ ] Q 2

The pump's manufacturer-tested performance curve H p u m p ( Q ) H_{pump}(Q) H p u m p ​ ( Q ) slopes downward as flow increases. The intersection of H p u m p ( Q ) H_{pump}(Q) H p u m p ​ ( Q ) and H s y s ( Q ) H_{sys}(Q) H sys ​ ( Q ) establishes the unique operating duty point ( Q o p , H o p ) (Q_{op}, H_{op}) ( Q o p ​ , H o p ​ ) . Head (H) ^ Pump Head Curve H_pump(Q)

  • | \
  • | \ System Curve H_sys = H_stat + C*Q^2
  • | \ /
  • | \ /
  • H_op|......*-----------/ <-- Operating Point (Duty Point)
  • | / \ /
  • | / \ /
  • H_stat|---+ \ /
  • | \ /
  • | \ /
  • +-----------------------------> Flow Rate (Q)
  • Q_op
  • Pumps Operating in Series vs. Parallel

Series Operation: Pumps arranged in series handle the same flow rate while their heads add: H t o t a l ( Q ) = H A ( Q ) + H B ( Q ) H_{total}(Q) = H_A(Q) + H_B(Q) H t o t a l ​ ( Q ) = H A ​ ( Q ) + H B ​ ( Q ) . Used for high-pressure boiler feed systems.

Parallel Operation: Pumps discharging into a common header experience identical head while their capacities add: Q t o t a l ( H ) = Q A ( H ) + Q B ( H ) Q_{total}(H) = Q_A(H) + Q_B(H) Q t o t a l ​ ( H ) = Q A ​ ( H ) + Q B ​ ( H ) . Used for high-capacity cooling water circulation.

4. The Affinity Laws for Centrifugal Pumps

The affinity laws scale pump performance when modifying rotational shaft speed ( N N N , in rpm) or trimming impeller outer diameter ( D D D ):

Variable Speed ( N N N ) with Constant Impeller Diameter ( D D D ) Q 2 Q 1 = N 2 N 1 , H 2 H 1 = ( N 2 N 1 ) 2 , B H P 2 B H P 1 = ( N 2 N 1 ) 3 \frac{Q_2}{Q_1} = \frac{N_2}{N_1}, \quad \frac{H_2}{H_1} = \left(\frac{N_2}{N_1}\right)^2, \quad \frac{BHP_2}{BHP_1} = \left(\frac{N_2}{N_1}\right)^3 Q 1 ​ Q 2 ​ ​ = N 1 ​ N 2 ​ ​ , H 1 ​ H 2 ​ ​ = ( N 1 ​ N 2 ​ ​ ) 2 , B H P 1 ​ B H P 2 ​ ​ = ( N 1 ​ N 2 ​ ​ ) 3

Impeller Trimming ( D D D ) at Constant Speed ( N N N )

(Valid for small trims within 10 % − 20 % 10\% - 20\% 10% − 20% of original diameter): Q 2 Q 1 = D 2 D 1 , H 2 H 1 = ( D 2 D 1 ) 2 , B H P 2 B H P 1 = ( D 2 D 1 ) 3 \frac{Q_2}{Q_1} = \frac{D_2}{D_1}, \quad \frac{H_2}{H_1} = \left(\frac{D_2}{D_1}\right)^2, \quad \frac{BHP_2}{BHP_1} = \left(\frac{D_2}{D_1}\right)^3 Q 1 ​ Q 2 ​ ​ = D 1 ​ D 2 ​ ​ , H 1 ​ H 2 ​ ​ = ( D 1 ​ D 2 ​ ​ ) 2 , B H P 1 ​ B H P 2 ​ ​ = ( D 1 ​ D 2 ​ ​ ) 3

Tip

Affinity Exponents Memory Aid: Flow is linear ( 1 1 1 ), Head is squared ( 2 2 2 ), Power is cubed ( 3 3 3 ). A 10 % 10\% 10% increase in pump speed yields a 10 % 10\% 10% increase in flow, a 21 % 21\% 21% increase in head ( ( 1.10 ) 2 = 1.21 (1.10)^2 = 1.21 ( 1.10 ) 2 = 1.21 ), and a 33.1 % 33.1\% 33.1% surge in motor power ( ( 1.10 ) 3 = 1.331 (1.10)^3 = 1.331 ( 1.10 ) 3 = 1.331 )!

  • 5. Cavitation Physics and Net Positive Suction Head (NPSH)
  • The Mechanism of Cavitation

As fluid accelerates into the eye of a centrifugal impeller, local static pressure drops to its lowest point in the system. If this localized pressure falls to or below the fluid's vapor pressure at the operating temperature ( P l o c a l ≤ P v p P_{local} \le P_{vp} P l oc a l ​ ≤ P v p ​ ), the liquid spontaneously boils, generating vapor bubbles. As these bubbles sweep outward into high-pressure regions along the impeller vanes, they collapse violently in microseconds. The resulting micro-jets generate localized shock pressures exceeding 1 , 000 MPa 1,000\text{ MPa} 1 , 000 MPa ( 145 , 000 psi 145,000\text{ psi} 145 , 000 psi ), pitting metal, eroding impellers, generating intense gravel-like noise, and destroying mechanical seals.

NPSHR vs. NPSHA

NPSHR (Net Positive Suction Head Required): A function of pump design determined by the manufacturer via water testing (standardized at a 3 % 3\% 3% head drop criterion, N P S H 3 NPSH_3 NPS H 3 ​ ). It is the minimum suction head over vapor pressure required at the suction nozzle to suppress cavitation.

NPSHA (Net Positive Suction Head Available): A property of the plant process piping system. It represents the absolute suction head over vapor pressure actually delivered to the pump suction nozzle.

The Governing NPSHA Equation N P S H A = P s u c t , a b s − P v p ρ g + v s 2 2 g NPSHA = \frac{P_{suct,abs} - P_{vp}}{\rho g} + \frac{v_s^2}{2g} NPS H A = ρ g P s u c t , ab s ​ − P v p ​ ​ + 2 g v s 2 ​ ​

Referenced back to the upstream supply vessel free liquid surface: N P S H A = P s o u r c e , a b s ρ g + z s − h f , s u c t − P v p ρ g NPSHA = \frac{P_{source,abs}}{\rho g} + z_s - h_{f,suct} - \frac{P_{vp}}{\rho g} NPS H A = ρ g P so u rce , ab s ​ ​ + z s ​ − h f , s u c t ​ − ρ g P v p ​ ​

where:

P s o u r c e , a b s P_{source,abs} P so u rce , ab s ​ is the absolute pressure on the liquid surface in the supply tank ( Pa \text{Pa} Pa or lb f / ft 2 \text{lb}_f/\text{ft}^2 lb f ​ / ft 2 ),

P v p P_{vp} P v p ​ is the true vapor pressure of the liquid at pumping temperature ( Pa \text{Pa} Pa or lb f / ft 2 \text{lb}_f/\text{ft}^2 lb f ​ / ft 2 ),

z s z_s z s ​ is the static elevation of the supply liquid level relative to the pump suction centerline ( + z s +z_s + z s ​ for flooded suction head; − z s -z_s − z s ​ for suction lift),

h f , s u c t h_{f,suct} h f , s u c t ​ is the cumulative frictional head loss (pipe skin friction + valves/fittings + entrance) in the suction line.

The Saturated / Boiling Liquid Case (Reboilers, Deaerators, Reflux Accumulators)

In chemical processing, liquids often leave separators or bottoms sumps at their bubble point (saturation pressure): P s o u r c e , a b s = P v p P_{source,abs} = P_{vp} P so u rce , ab s ​ = P v p ​ .

When P s o u r c e , a b s = P v p P_{source,abs} = P_{vp} P so u rce , ab s ​ = P v p ​ , the pressure terms cancel completely: N P S H A = z s − h f , s u c t NPSHA = z_s - h_{f,suct} NPS H A = z s ​ − h f , s u c t ​

Warning

Critical PE Exam Rule: For a boiling liquid, the tank pressure cannot help you! The only available suction head comes from the physical liquid elevation z s z_s z s ​ above the pump centerline minus suction piping friction h f , s u c t h_{f,suct} h f , s u c t ​ . If a boiling liquid pump is placed at grade with zero elevation head ( z s = 0 z_s = 0 z s ​ = 0 ), N P S H A NPSHA NPS H A is negative ( − h f , s u c t -h_{f,suct} − h f , s u c t ​ ), and the pump will cavitate instantly!

6. Gas Compressors and Blowers

When compressing compressible gases where density varies substantially, fluid compression work is evaluated using thermodynamic path functions:

Isentropic (Reversible Adiabatic) Compression Power

For an ideal gas with heat capacity ratio k = C p / C v k = C_p / C_v k = C p ​ / C v ​ : W i s e n = m ˙ ( k k − 1 ) R T 1 [ ( P 2 P 1 ) k − 1 k − 1 ] = ( k k − 1 ) P 1 Q 1 [ ( P 2 P 1 ) k − 1 k − 1 ] W_{isen} = \dot{m} \left(\frac{k}{k-1}\right) R T_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} - 1 \right] = \left(\frac{k}{k-1}\right) P_1 Q_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} - 1 \right] W i se n ​ = m ˙ ( k − 1 k ​ ) R T 1 ​ [ ( P 1 ​ P 2 ​ ​ ) k k − 1 ​ − 1 ] = ( k − 1 k ​ ) P 1 ​ Q 1 ​ [ ( P 1 ​ P 2 ​ ​ ) k k − 1 ​ − 1 ]

The isentropic discharge temperature is: T 2 , i s e n = T 1 ( P 2 P 1 ) k − 1 k T_{2,isen} = T_1 \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} T 2 , i se n ​ = T 1 ​ ( P 1 ​ P 2 ​ ​ ) k k − 1 ​

Polytropic Compression

Real industrial compressors deviate from isentropic paths due to internal friction and heat dissipation, described by the polytropic exponent n n n : n n − 1 = ( k k − 1 ) η p o l y \frac{n}{n-1} = \left(\frac{k}{k-1}\right) \eta_{poly} n − 1 n ​ = ( k − 1 k ​ ) η p o l y ​

To limit discharge temperatures below lubricant breakdown limits ( T 2 < 150 ∘ C T_2 < 150^\circ\text{C} T 2 ​ < 15 0 ∘ C / 300 ∘ F 300^\circ\text{F} 30 0 ∘ F ) and minimize overall compression work, large compression ratios are split into multistage compression with intercooling between stages. For equal work distribution across N s t a g e s N_{stages} N s t a g es ​ with perfect intercooling to T 1 T_1 T 1 ​ , the stage pressure ratio is constant: r p = ( P f i n a l P i n i t i a l ) 1 / N s t a g e s r_p = \left(\frac{P_{final}}{P_{initial}}\right)^{1 / N_{stages}} r p ​ = ( P ini t ia l ​ P f ina l ​ ​ ) 1/ N s t a g es ​

7. Comparison Table of Industrial Process Pumps

Pump Technology Flow vs. Head Curve Viscosity Limit Solids / Slurries Flow Characteristics Overpressure Protection

Centrifugal (Radial) Head decreases as flow increases Low ( < 500 cSt < 500\text{ cSt} < 500 cSt ; derated above) Good with open impeller Smooth, continuous Self-limiting at shutoff head; bypass for thermal relief

Reciprocating Plunger Vertical line (constant Q Q Q at any H H H ) High ( > 10 , 000 cSt > 10,000\text{ cSt} > 10 , 000 cSt ) Poor (valves foul and erode) Pulsating (requires pulsation dampeners) Mandatory external PRV upstream of discharge valve

Rotary External Gear Steep (nearly constant Q Q Q ) Very high ( > 100 , 000 cSt > 100,000\text{ cSt} > 100 , 000 cSt ) Poor (abrasives destroy gear teeth) Smooth, continuous Mandatory internal or external safety relief valve

Progressive Cavity Steep linear slope Ultra-high (sludges, pastes) Excellent (abrasives/fibers) Non-pulsating, low shear Mandatory relief valve; stator fails if run dry

Air-Operated Diaphragm (AODD) Matches air supply pressure High Excellent (shear-sensitive slurries) Pulsating Self-stalls when discharge line closes; inherently safe

  • 8. Step-by-Step Worked Numerical Example
  • Problem Statement

A centrifugal pump transfers liquid n-hexane ( S G = 0.655 SG = 0.655 SG = 0.655 , ρ = 655 kg/m 3 \rho = 655\text{ kg/m}^3 ρ = 655 kg/m 3 ) from an enclosed reflux accumulator to an overhead distillation column. The accumulator operates at a blanket pressure of P 1 = 180 kPa(a) P_1 = 180\text{ kPa(a)} P 1 ​ = 180 kPa(a) (absolute). At the operating temperature of 55 ∘ C 55^\circ\text{C} 5 5 ∘ C , the vapor pressure of n-hexane is P v p = 65.0 kPa(a) P_{vp} = 65.0\text{ kPa(a)} P v p ​ = 65.0 kPa(a) .

System parameters:

Liquid level in accumulator: z 1 = + 3.50 m z_1 = +3.50\text{ m} z 1 ​ = + 3.50 m above the pump centerline.

Suction line frictional head loss at design flow: h f , s u c t = 0.65 m h_{f,suct} = 0.65\text{ m} h f , s u c t ​ = 0.65 m .

Destination column nozzle elevation: z 2 = + 24.0 m z_2 = +24.0\text{ m} z 2 ​ = + 24.0 m above the pump centerline.

Destination column operating pressure: P 2 = 320 kPa(a) P_2 = 320\text{ kPa(a)} P 2 ​ = 320 kPa(a) .

Discharge line frictional head loss: h f , d i s c h = 4.80 m h_{f,disch} = 4.80\text{ m} h f , d i sc h ​ = 4.80 m .

Design flow rate: Q = 45.0 m 3 / h = 0.0125 m 3 / s Q = 45.0\text{ m}^3/\text{h} = 0.0125\text{ m}^3/\text{s} Q = 45.0 m 3 / h = 0.0125 m 3 / s .

Pump efficiency: η p = 0.68 \eta_p = 0.68 η p ​ = 0.68 .

Manufacturer's required suction head: N P S H R = 2.20 m NPSHR = 2.20\text{ m} NPS H R = 2.20 m .

Gravitational acceleration: g = 9.807 m/s 2 g = 9.807\text{ m/s}^2 g = 9.807 m/s 2 .

Calculate:

The Net Positive Suction Head Available ( N P S H A NPSHA NPS H A ) in meters of hexane.

The available NPSH safety margin over N P S H R NPSHR NPS H R .

The Total Dynamic Head ( T D H TDH T DH ) developed by the pump in meters.

The Brake Horsepower ( B H P BHP B H P ) required from the electric motor in kilowatts and horsepower.

Solution

Step 1: Calculate NPSHA. N P S H A = P 1 , a b s − P v p ρ g + z 1 − h f , s u c t NPSHA = \frac{P_{1,abs} - P_{vp}}{\rho g} + z_1 - h_{f,suct} NPS H A = ρ g P 1 , ab s ​ − P v p ​ ​ + z 1 ​ − h f , s u c t ​

Calculate the net static pressure head over vapor pressure: Δ P s u c t = P 1 , a b s − P v p = 180.0 kPa − 65.0 kPa = 115.0 kPa = 115 , 000 Pa \Delta P_{suct} = P_{1,abs} - P_{vp} = 180.0\text{ kPa} - 65.0\text{ kPa} = 115.0\text{ kPa} = 115,000\text{ Pa} Δ P s u c t ​ = P 1 , ab s ​ − P v p ​ = 180.0 kPa − 65.0 kPa = 115.0 kPa = 115 , 000 Pa Pressure Head = 115 , 000 Pa 655 kg/m 3 × 9.807 m/s 2 = 115 , 000 6 , 423.6 = 17.903 m \text{Pressure Head} = \frac{115,000\text{ Pa}}{655\text{ kg/m}^3 \times 9.807\text{ m/s}^2} = \frac{115,000}{6,423.6} = 17.903\text{ m} Pressure Head = 655 kg/m 3 × 9.807 m/s 2 115 , 000 Pa ​ = 6 , 423.6 115 , 000 ​ = 17.903 m

Insert into the NPSHA equation: N P S H A = 17.903 m + 3.50 m − 0.65 m = 20.753 m ≈ 20.75 m NPSHA = 17.903\text{ m} + 3.50\text{ m} - 0.65\text{ m} = 20.753\text{ m} \approx 20.75\text{ m} NPS H A = 17.903 m + 3.50 m − 0.65 m = 20.753 m ≈ 20.75 m

Step 2: Check NPSH safety margin. Margin = N P S H A − N P S H R = 20.75 m − 2.20 m = 18.55 m \text{Margin} = NPSHA - NPSHR = 20.75\text{ m} - 2.20\text{ m} = 18.55\text{ m} Margin = NPS H A − NPS H R = 20.75 m − 2.20 m = 18.55 m N P S H A N P S H R = 20.75 2.20 = 9.43 \frac{NPSHA}{NPSHR} = \frac{20.75}{2.20} = 9.43 NPS H R NPS H A ​ = 2.20 20.75 ​ = 9.43

Because the margin far exceeds the API 610 minimum of 1.0 m 1.0\text{ m} 1.0 m ( 3.3 ft 3.3\text{ ft} 3.3 ft ) and the N P S H A / N P S H R NPSHA/NPSHR NPS H A / NPS H R ratio exceeds 1.2 1.2 1.2 , the pump is fully protected against cavitation.

Step 3: Calculate Total Dynamic Head (TDH). Applying the MEB between liquid surfaces 1 1 1 and 2 2 2 : T D H = P 2 , a b s − P 1 , a b s ρ g + ( z 2 − z 1 ) + h f , s u c t + h f , d i s c h TDH = \frac{P_{2,abs} - P_{1,abs}}{\rho g} + (z_2 - z_1) + h_{f,suct} + h_{f,disch} T DH = ρ g P 2 , ab s ​ − P 1 , ab s ​ ​ + ( z 2 ​ − z 1 ​ ) + h f , s u c t ​ + h f , d i sc h ​

Evaluate pressure head difference: Δ P v e s s e l s = P 2 , a b s − P 1 , a b s = 320.0 kPa − 180.0 kPa = 140.0 kPa = 140 , 000 Pa \Delta P_{vessels} = P_{2,abs} - P_{1,abs} = 320.0\text{ kPa} - 180.0\text{ kPa} = 140.0\text{ kPa} = 140,000\text{ Pa} Δ P v esse l s ​ = P 2 , ab s ​ − P 1 , ab s ​ = 320.0 kPa − 180.0 kPa = 140.0 kPa = 140 , 000 Pa Pressure Head = 140 , 000 Pa 655 kg/m 3 × 9.807 m/s 2 = 21.795 m \text{Pressure Head} = \frac{140,000\text{ Pa}}{655\text{ kg/m}^3 \times 9.807\text{ m/s}^2} = 21.795\text{ m} Pressure Head = 655 kg/m 3 × 9.807 m/s 2 140 , 000 Pa ​ = 21.795 m

Evaluate elevation and friction:

Static elevation difference: z 2 − z 1 = 24.0 m − 3.50 m = 20.50 m z_2 - z_1 = 24.0\text{ m} - 3.50\text{ m} = 20.50\text{ m} z 2 ​ − z 1 ​ = 24.0 m − 3.50 m = 20.50 m

Total friction loss: h f , t o t a l = 0.65 m + 4.80 m = 5.45 m h_{f,total} = 0.65\text{ m} + 4.80\text{ m} = 5.45\text{ m} h f , t o t a l ​ = 0.65 m + 4.80 m = 5.45 m

Sum all components: T D H = 21.795 m + 20.50 m + 5.45 m = 47.745 m ≈ 47.75 m TDH = 21.795\text{ m} + 20.50\text{ m} + 5.45\text{ m} = 47.745\text{ m} \approx 47.75\text{ m} T DH = 21.795 m + 20.50 m + 5.45 m = 47.745 m ≈ 47.75 m

Step 4: Calculate pump power requirements. Hydraulic power delivered to the liquid ( W H P WHP W H P ): W H P = ρ g Q ( T D H ) = 655 kg/m 3 × 9.807 m/s 2 × 0.0125 m 3 / s × 47.745 m WHP = \rho g Q (TDH) = 655\text{ kg/m}^3 \times 9.807\text{ m/s}^2 \times 0.0125\text{ m}^3/\text{s} \times 47.745\text{ m} W H P = ρ g Q ( T DH ) = 655 kg/m 3 × 9.807 m/s 2 × 0.0125 m 3 / s × 47.745 m W H P = 6 , 423.6 × 0.0125 × 47.745 = 3 , 833.7 W = 3.834 kW WHP = 6,423.6 \times 0.0125 \times 47.745 = 3,833.7\text{ W} = 3.834\text{ kW} W H P = 6 , 423.6 × 0.0125 × 47.745 = 3 , 833.7 W = 3.834 kW

Brake Horsepower ( B H P BHP B H P ) required at pump shaft: B H P = W H P η p = 3.834 kW 0.68 = 5.638 kW BHP = \frac{WHP}{\eta_p} = \frac{3.834\text{ kW}}{0.68} = 5.638\text{ kW} B H P = η p ​ W H P ​ = 0.68 3.834 kW ​ = 5.638 kW

Convert to mechanical horsepower: B H P = 5.638 kW × ( 1 hp 0.7457 kW ) = 7.56 hp BHP = 5.638\text{ kW} \times \left(\frac{1\text{ hp}}{0.7457\text{ kW}}\right) = 7.56\text{ hp} B H P = 5.638 kW × ( 0.7457 kW 1 hp ​ ) = 7.56 hp

For industrial reliability, select a standard 10 hp 10\text{ hp} 10 hp ( 7.5 kW 7.5\text{ kW} 7.5 kW ) motor to provide adequate margin against end-of-curve motor overload.

9. Common PE Exam Traps in Pumps, Compressors, and NPSH

Using Gauge Pressure in NPSHA: The single most catastrophic error on the exam. Atmospheric pressure must be included in absolute pressure terms. Using gauge pressure causes calculated NPSHA to be negative or off by 10.33 m of water 10.33\text{ m of water} 10.33 m of water ( 33.9 ft 33.9\text{ ft} 33.9 ft ). Always convert to absolute pressure before calculating NPSH.

Overlooking the Saturated Fluid Simplification: For boiling liquids in reboilers, flash drums, and deaerators, P s o u r c e , a b s = P v p P_{source,abs} = P_{vp} P so u rce , ab s ​ = P v p ​ . Never attempt to look up atmospheric pressure for closed saturation vessels; the pressure terms cancel identically, leaving N P S H A = z s − h f NPSHA = z_s - h_f NPS H A = z s ​ − h f ​ .

Mixing Up Affinity Law Exponents: Remember that head scales with speed squared ( N 2 N^2 N 2 ) and power scales with speed cubed ( N 3 N^3 N 3 ). Applying linear scaling to head or power is a fatal mistake.

Forgetting Specific Gravity in Pump Power: Centrifugal pump head ( T D H TDH T DH , in feet or meters) is independent of fluid density. However, Brake Horsepower is directly proportional to density ( S G SG SG ). Pumping brine ( S G = 1.2 SG = 1.2 SG = 1.2 ) requires 20 % 20\% 20% more motor power than pumping pure water ( S G = 1.0 SG = 1.0 SG = 1.0 ) at the identical head and flow!