Study guide

15.2 Thermal Conductivity and Specific Heat Capacities

PE Chemical Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the PE Chemical Exam How to Use This Guide and the NCEES Handbook

2 Chapter 1: Material Balances & Flowsheet Calculations

1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations

3 Chapter 2: Energy Balances & Thermochemistry

2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances

4 Chapter 3: Fluid Statics & Incompressible Pipe Flow

3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations

5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow

4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up

6 Chapter 5: Thermodynamic Laws & Fundamental Relations

5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations

7 Chapter 6: Real Gases & Equations of State

6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions

8 Chapter 7: Phase & Chemical Reaction Equilibria

7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation

9 Chapter 8: Heat Transfer Mechanisms & Conduction

8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange

10 Chapter 9: Heat Exchanger Design & Phase Change

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances

11 Chapter 10: Mass Transfer Fundamentals & Diffusion

10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)

12 Chapter 11: Distillation Operations

11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components

13 Chapter 12: Rate-Controlled & Equilibrium Separations

12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations

14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors

13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations

15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis

14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models

16 Chapter 15: Physical & Transport Properties of Fluids

15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles

17 Chapter 16: Materials of Construction & Corrosion

16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention

18 Chapter 17: Process Safety & Pressure Relief Systems

17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment

19 Chapter 18: Process Control & Engineering Economics

18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems

20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance

19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation

21 Chapter 20: Plant Operation, Reliability & Continuous Improvement

20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting

15.2 Thermal Conductivity and Specific Heat Capacities

Key Takeaways Explain This Topic AI

Fourier's law q = -k * dT/dx defines thermal conductivity k; typical gas thermal conductivities range from 0.010 to 0.040 W/(m·K), organic liquids range from 0.10 to 0.20 W/(m·K), and liquid water displays an exceptionally high value of 0.60 to 0.68 W/(m·K).

The modified Eucken correlation estimates polyatomic gas thermal conductivity from dynamic viscosity and heat capacity: k = (μ / M) * (C_p + 1.25 * R) = (μ / M) * (C_v + 2.25 * R), successfully accounting for translational, rotational, and vibrational energy modes.

Thermal conductivity varies in opposite directions across phases with temperature: gas k increases with temperature (k ∝ T^n), whereas liquid k decreases almost linearly with temperature for virtually all fluids, with liquid water being the famous anomaly whose k increases up to 130°C (403 K) before declining.

Ideal gas heat capacity C_p°(T) is parameterized by polynomials (such as the Shomate or NASA equations); liquid heat capacity C_p^L is always significantly greater than C_p° at the same temperature (C_p^L > C_p°) due to intermolecular vibrational and structural modes.

Kopp's rule provides a rapid estimation technique for solid and liquid molar heat capacities at ambient conditions by summing atomic contributions: approximately 7.5 J/(mol·K) for C, 9.6 for H, 16.7 for O, and 26.0 for heavy metals and halogens.

Last updated: September 2026

15.2 Thermal Conductivity and Specific Heat Capacities

Thermal transport properties—specifically thermal conductivity ( k k k ) and specific heat capacity ( C p C_p C p ​ )—govern energy conservation equations, heat exchanger surface area sizing, and transient heating/cooling operations in process plants. These properties appear in key dimensionless transport groups on the NCEES PE Chemical Exam , notably the Prandtl number ( Pr = C p μ / k \text{Pr} = C_p \mu / k Pr = C p ​ μ / k ) and the thermal diffusivity ( α = k / ( ρ C p ) \alpha = k / (\rho C_p) α = k / ( ρ C p ​ ) ).

  • 1. Thermal Conductivity Fundamentals & Fourier's Law
  • Fourier's Law of Heat Conduction

Thermal conduction is the transfer of internal thermal energy via microscopic molecular collisions and electron/phonon transport. In one dimension, Fourier's Law states: q x = − k d T d x q_x = -k \frac{dT}{dx} q x ​ = − k d x d T ​

Where:

q x q_x q x ​ = conductive heat flux ( W/m 2 \text{W/m}^2 W/m 2 or Btu / ( hr ⋅ ft 2 ) \text{Btu}/(\text{hr}\cdot\text{ft}^2) Btu / ( hr ⋅ ft 2 ) ).

k k k = thermal conductivity .

d T / d x dT/dx d T / d x = temperature gradient ( K/m \text{K/m} K/m or ∘ F/ft ^\circ\text{F/ft} ∘ F/ft ).

Units and Conversions

SI Unit: W / ( m ⋅ K ) = J / ( s ⋅ m ⋅ K ) \text{W}/(\text{m}\cdot\text{K}) = \text{J}/(\text{s}\cdot\text{m}\cdot\text{K}) W / ( m ⋅ K ) = J / ( s ⋅ m ⋅ K ) .

US Customary Unit: Btu / ( hr ⋅ ft ⋅ ∘ F ) \text{Btu}/(\text{hr}\cdot\text{ft}\cdot^\circ\text{F}) Btu / ( hr ⋅ ft ⋅ ∘ F ) .

Conversion Factor: 1.0 Btu / ( hr ⋅ ft ⋅ ∘ F ) = 1.7307 W / ( m ⋅ K ) ⟺ 1.0 W / ( m ⋅ K ) = 0.5778 Btu / ( hr ⋅ ft ⋅ ∘ F ) 1.0\text{ Btu}/(\text{hr}\cdot\text{ft}\cdot^\circ\text{F}) = 1.7307\text{ W}/(\text{m}\cdot\text{K}) \iff 1.0\text{ W}/(\text{m}\cdot\text{K}) = 0.5778\text{ Btu}/(\text{hr}\cdot\text{ft}\cdot^\circ\text{F}) 1.0 Btu / ( hr ⋅ ft ⋅ ∘ F ) = 1.7307 W / ( m ⋅ K ) ⟺ 1.0 W / ( m ⋅ K ) = 0.5778 Btu / ( hr ⋅ ft ⋅ ∘ F ) 1.0 cal / ( s ⋅ cm ⋅ ∘ C ) = 418.4 W / ( m ⋅ K ) 1.0\text{ cal}/(\text{s}\cdot\text{cm}\cdot^\circ\text{C}) = 418.4\text{ W}/(\text{m}\cdot\text{K}) 1.0 cal / ( s ⋅ cm ⋅ ∘ C ) = 418.4 W / ( m ⋅ K )

The Prandtl Number ( Pr \text{Pr} Pr )

The dimensionless Prandtl number measures the relative rate of momentum diffusion to thermal diffusion in the velocity and thermal boundary layers: Pr ≡ ν α = μ / ρ k / ( ρ C p ) = C p μ k \text{Pr} \equiv \frac{\nu}{\alpha} = \frac{\mu / \rho}{k / (\rho C_p)} = \frac{C_p \mu}{k} Pr ≡ α ν ​ = k / ( ρ C p ​ ) μ / ρ ​ = k C p ​ μ ​

Representative magnitudes:

Liquid metals (mercury, sodium): Pr ∼ 0.004 − 0.03 \text{Pr} \sim 0.004 - 0.03 Pr ∼ 0.004 − 0.03 (conduction dominates over convection).

Air and light gases: Pr ≈ 0.69 − 0.72 \text{Pr} \approx 0.69 - 0.72 Pr ≈ 0.69 − 0.72 (momentum and thermal boundary layers grow at identical rates).

Liquid water ( 20 ∘ C 20^\circ\text{C} 2 0 ∘ C ): Pr ≈ 7.0 \text{Pr} \approx 7.0 Pr ≈ 7.0 .

Viscous lubricating oils, glycols: Pr ∼ 50 − 10 , 000 \text{Pr} \sim 50 - 10,000 Pr ∼ 50 − 10 , 000 (momentum boundary layer is vastly thicker than the thermal boundary layer).

  • 2. Gas Thermal Conductivity Estimation
  • Monatomic Gases (Kinetic Theory)

For dilute monatomic gases (helium, argon), molecules possess only 3 translational degrees of freedom ( C v = 3 2 R C_v = \frac{3}{2} R C v ​ = 2 3 ​ R ). Elementary kinetic theory relates thermal conductivity directly to dynamic viscosity: k = 5 2 μ c v = 5 2 μ M C v = 15 4 R M μ k = \frac{5}{2} \mu c_v = \frac{5}{2} \frac{\mu}{M} C_v = \frac{15}{4} \frac{R}{M} \mu k = 2 5 ​ μ c v ​ = 2 5 ​ M μ ​ C v ​ = 4 15 ​ M R ​ μ

Where c v c_v c v ​ is specific heat capacity ( J / ( kg ⋅ K ) \text{J}/(\text{kg}\cdot\text{K}) J / ( kg ⋅ K ) ), C v C_v C v ​ is molar heat capacity ( J / ( mol ⋅ K ) \text{J}/(\text{mol}\cdot\text{K}) J / ( mol ⋅ K ) ), and M M M is molecular weight ( kg/mol \text{kg/mol} kg/mol ).

Polyatomic Gases: The Modified Eucken Correlation

Polyatomic molecules possess rotational and vibrational energy storage modes in addition to translation. Translational energy transfers at the collision rate (factor ≈ 2.5 \approx 2.5 ≈ 2.5 ), while internal rotational/vibrational energy diffuses more slowly (factor ≈ 1.0 \approx 1.0 ≈ 1.0 ). The modified Eucken correlation partitions these modes: k = μ M ( C v + 9 4 R ) = μ M ( C p + 5 4 R ) = μ M ( C p + 1.25 R ) k = \frac{\mu}{M} \left( C_v + \frac{9}{4} R \right) = \frac{\mu}{M} \left( C_p + \frac{5}{4} R \right) = \frac{\mu}{M} \left( C_p + 1.25 R \right) k = M μ ​ ( C v ​ + 4 9 ​ R ) = M μ ​ ( C p ​ + 4 5 ​ R ) = M μ ​ ( C p ​ + 1.25 R )

Where:

k k k = gas thermal conductivity ( W / ( m ⋅ K ) \text{W}/(\text{m}\cdot\text{K}) W / ( m ⋅ K ) ).

μ \mu μ = gas dynamic viscosity ( Pa ⋅ s = kg / ( m ⋅ s ) \text{Pa}\cdot\text{s} = \text{kg}/(\text{m}\cdot\text{s}) Pa ⋅ s = kg / ( m ⋅ s ) ).

M M M = molecular weight ( kg/mol \text{kg/mol} kg/mol ; e.g., for methane M = 0.01604 kg/mol M = 0.01604\text{ kg/mol} M = 0.01604 kg/mol ).

C p , C v C_p, C_v C p ​ , C v ​ = ideal gas molar heat capacities ( J / ( mol ⋅ K ) \text{J}/(\text{mol}\cdot\text{K}) J / ( mol ⋅ K ) ).

R R R = universal gas constant ( 8.3145 J / ( mol ⋅ K ) 8.3145\text{ J}/(\text{mol}\cdot\text{K}) 8.3145 J / ( mol ⋅ K ) ).

Temperature and Pressure Dependencies in Gases

Temperature: At low to moderate pressures, gas thermal conductivity increases with temperature ( k ∝ T n k \propto T^n k ∝ T n , where n ≈ 0.65 − 1.0 n \approx 0.65 - 1.0 n ≈ 0.65 − 1.0 ) because molecular velocities increase and internal vibrational modes become thermally active.

Pressure: For dilute gases ( P < 10 bar P < 10\text{ bar} P < 10 bar ), thermal conductivity is virtually independent of pressure. At high pressures ( P r > 1 P_r > 1 P r ​ > 1 ), dense gas clustering increases k k k , especially near the critical point.

  • 3. Liquid Thermal Conductivity & The Water Anomaly
  • General Liquid Behavior

In liquids, heat is conducted via acoustic waves and lattice-like molecular vibrational collisions. As temperature increases, liquid thermal expansion increases average intermolecular separation, dampening collisional energy transmission between adjacent molecular cages. Therefore, for almost all organic and inorganic liquids, thermal conductivity decreases with increasing temperature : k L ( T ) ≈ k 0 [ 1 − β ( T − T 0 ) ] k_L(T) \approx k_0 [1 - \beta (T - T_0)] k L ​ ( T ) ≈ k 0 ​ [ 1 − β ( T − T 0 ​ )]

Typical organic liquid values range between 0.10 0.10 0.10 and 0.20 W / ( m ⋅ K ) 0.20\text{ W}/(\text{m}\cdot\text{K}) 0.20 W / ( m ⋅ K ) at ambient conditions (e.g., benzene ≈ 0.144 W / ( m ⋅ K ) \approx 0.144\text{ W}/(\text{m}\cdot\text{K}) ≈ 0.144 W / ( m ⋅ K ) , ethanol ≈ 0.167 W / ( m ⋅ K ) \approx 0.167\text{ W}/(\text{m}\cdot\text{K}) ≈ 0.167 W / ( m ⋅ K ) ).

The Thermal Anomaly of Liquid Water

Liquid water is the famous, critical exception to the rule! Due to its extensive three-dimensional hydrogen bonding network, liquid water at ambient conditions contains open, ice-like cage structures. As water is heated from 0 ∘ C 0^\circ\text{C} 0 ∘ C to ≈ 130 ∘ C \approx 130^\circ\text{C} ≈ 13 0 ∘ C ( 403 K 403\text{ K} 403 K ), thermal energy travels through the hydrogen-bond network by a fast, quasi-lattice (phonon-like) mechanism rather than by slow molecular translation alone. Rising temperature raises molecular vibration amplitude and collision frequency, which strengthens that vibrational transfer faster than the progressive rupture of hydrogen bonds weakens the network, so k k k increases.

Do not attribute the rise to densification: liquid water becomes steadily less dense above 4 ∘ C 4^\circ\text{C} 4 ∘ C , falling from 999.97 kg/m 3 999.97\text{ kg/m}^3 999.97 kg/m 3 at 4 ∘ C 4^\circ\text{C} 4 ∘ C to roughly 935 kg/m 3 935\text{ kg/m}^3 935 kg/m 3 at 130 ∘ C 130^\circ\text{C} 13 0 ∘ C . Only above ≈ 130 ∘ C \approx 130^\circ\text{C} ≈ 13 0 ∘ C does the combination of continued thermal expansion and extensive hydrogen-bond breakdown finally dominate, causing k k k to decline and then collapse toward the critical point. Furthermore, water's thermal conductivity ( 0.60 − 0.68 W / ( m ⋅ K ) 0.60 - 0.68\text{ W}/(\text{m}\cdot\text{K}) 0.60 − 0.68 W / ( m ⋅ K ) ) is 3 to 5 times higher than almost all organic solvents: Thermal Conductivity k [W/(m*K)]

  • ^
  • 0.7 | * * * (Peak at ~130°C: k ≈ 0.687)
  • | * *
  • 0.6 | Saturated Water * *
  • |-----------------------------------------------------
  • 0.2 | Organic Liquids (Benzene, Toluene)
  • 0.1 | \ (k decreases monotonically)
  • | \---------------------
  • 0.0 +----------------------------------------------------> Temperature (°C)
  • 0 50 100 130 150 200
  • Liquid Estimation Methods

Latini Correlation: k L = A ( 1 − T r ) 0.38 T r 1 / 6 k_L = \frac{A (1 - T_r)^{0.38}}{T_r^{1/6}} k L ​ = T r 1/6 ​ A ( 1 − T r ​ ) 0.38 ​ Where A A A is a characteristic dimensional constant tabulated by chemical family.

Robbins-Kingrea Correlation: Employs normal boiling point, heat of vaporization Δ H v b \Delta H_{vb} Δ H v b ​ , and liquid density ρ L \rho_L ρ L ​ to estimate k L k_L k L ​ .

  • 4. Heat Capacity Formulations
  • Fundamental Thermodynamic Relations

Molar heat capacities at constant volume ( C v C_v C v ​ ) and constant pressure ( C p C_p C p ​ ) are defined as: C v ≡ ( ∂ U ∂ T ) V , C p ≡ ( ∂ H ∂ T ) P C_v \equiv \left( \frac{\partial U}{\partial T} \right)_V, \quad C_p \equiv \left( \frac{\partial H}{\partial T} \right)_P C v ​ ≡ ( ∂ T ∂ U ​ ) V ​ , C p ​ ≡ ( ∂ T ∂ H ​ ) P ​

For any homogeneous fluid phase, the general thermodynamic relation is: C p − C v = − T ( ∂ V / ∂ T ) P 2 ( ∂ V / ∂ P ) T = T V β 2 κ T C_p - C_v = -T \frac{(\partial V / \partial T)_P^2}{(\partial V / \partial P)_T} = \frac{T V \beta^2}{\kappa_T} C p ​ − C v ​ = − T ( ∂ V / ∂ P ) T ​ ( ∂ V / ∂ T ) P 2 ​ ​ = κ T ​ T V β 2 ​

Where β = 1 V ( ∂ V / ∂ T ) P \beta = \frac{1}{V} (\partial V / \partial T)_P β = V 1 ​ ( ∂ V / ∂ T ) P ​ is the volumetric thermal expansivity and κ T = − 1 V ( ∂ V / ∂ P ) T \kappa_T = -\frac{1}{V} (\partial V / \partial P)_T κ T ​ = − V 1 ​ ( ∂ V / ∂ P ) T ​ is the isothermal compressibility. For an ideal gas ( P V = R T P V = R T P V = RT ), this reduces to Mayer's relation: C p ∘ − C v ∘ = R C_p^\circ - C_v^\circ = R C p ∘ ​ − C v ∘ ​ = R .

Ideal Gas Heat Capacity Polynomials

At low pressures, ideal gas heat capacity C p ∘ ( T ) C_p^\circ(T) C p ∘ ​ ( T ) is a function of temperature alone, representing translational, rotational, and vibrational molecular modes: C p ∘ ( T ) = a + b T + c T 2 + d T 3 C_p^\circ(T) = a + b T + c T^2 + d T^3 C p ∘ ​ ( T ) = a + b T + c T 2 + d T 3 C p ∘ ( T ) R = a 1 + a 2 T + a 3 T 2 + a 4 T 3 + a 5 T 4 \frac{C_p^\circ(T)}{R} = a_1 + a_2 T + a_3 T^2 + a_4 T^3 + a_5 T^4 R C p ∘ ​ ( T ) ​ = a 1 ​ + a 2 ​ T + a 3 ​ T 2 + a 4 ​ T 3 + a 5 ​ T 4

NIST Shomate Equation: Widely used in modern thermochemical software and tables: C p ∘ = A + B t + C t 2 + D t 3 + E t 2 C_p^\circ = A + B t + C t^2 + D t^3 + \frac{E}{t^2} C p ∘ ​ = A + Bt + C t 2 + D t 3 + t 2 E ​

Where t = T / 1000 t = T / 1000 t = T /1000 ( T T T in K \text{K} K ) and C p ∘ C_p^\circ C p ∘ ​ is in J / ( mol ⋅ K ) \text{J}/(\text{mol}\cdot\text{K}) J / ( mol ⋅ K ) .

Liquid Heat Capacity and Residual Property ( C p L > C p ∘ C_p^L > C_p^\circ C p L ​ > C p ∘ ​ )

Liquid heat capacity is always significantly greater than ideal gas heat capacity at the same temperature ( C p L > C p ∘ C_p^L > C_p^\circ C p L ​ > C p ∘ ​ ). In liquids, close intermolecular potential wells hinder free rotation and create low-frequency intermolecular vibrational modes (librations and cage oscillations) that store additional sensible energy. The difference is the residual heat capacity: C p L = C p ∘ + C p R C_p^L = C_p^\circ + C_p^R C p L ​ = C p ∘ ​ + C p R ​

Rowlinson-Bondi Correlation: C p L − C p ∘ R = 1.45 + 0.45 1 − T r + 0.25 ω [ 17.11 + 25.2 ( 1 − T r ) 1 / 3 T r + 1.74 1 − T r ] \frac{C_p^L - C_p^\circ}{R} = 1.45 + \frac{0.45}{1 - T_r} + 0.25 \omega \left[ 17.11 + \frac{25.2 (1 - T_r)^{1/3}}{T_r} + \frac{1.74}{1 - T_r} \right] R C p L ​ − C p ∘ ​ ​ = 1.45 + 1 − T r ​ 0.45 ​ + 0.25 ω [ 17.11 + T r ​ 25.2 ( 1 − T r ​ ) 1/3 ​ + 1 − T r ​ 1.74 ​ ]

Where ω \omega ω is Pitzer's acentric factor.

Kopp's Rule (Neumann-Kopp Law) for Condensed Phases

When experimental calorimetric data is unavailable for solid salts, minerals, or liquid compounds, Kopp's rule approximates molar heat capacity at 20 − 25 ∘ C 20-25^\circ\text{C} 20 − 2 5 ∘ C as the sum of atomic heat capacities of constituent elements: C p = ∑ i n i c p , i C_p = \sum_{i} n_i c_{p,i} C p ​ = i ∑ ​ n i ​ c p , i ​

Element Atomic Contribution c p , i c_{p,i} c p , i ​ [ J / ( mol ⋅ K ) \text{J}/(\text{mol}\cdot\text{K}) J / ( mol ⋅ K ) ] Atomic Contribution [ cal / ( mol ⋅ ∘ C ) \text{cal}/(\text{mol}\cdot^\circ\text{C}) cal / ( mol ⋅ ∘ C ) ]

  • Carbon (C) 7.5 7.5 7.5 1.8 1.8 1.8
  • Hydrogen (H) 9.6 9.6 9.6 2.3 2.3 2.3
  • Boron (B) 11.3 11.3 11.3 2.7 2.7 2.7
  • Silicon (Si) 15.9 15.9 15.9 3.8 3.8 3.8
  • Oxygen (O) 16.7 16.7 16.7 4.0 4.0 4.0
  • Fluorine (F) 20.9 20.9 20.9 5.0 5.0 5.0
  • Phosphorus (P), Sulfur (S) 22.6 22.6 22.6 5.4 5.4 5.4
  • All other elements / metals / halogens 26.0 26.0 26.0 6.2 6.2 6.2 (Dulong-Petit value ≈ 3 R \approx 3R ≈ 3 R )
  • 5. Comprehensive Worked Numerical Example
  • Problem Statement

An engineer is sizing a gas cooler and a catalyst bed. Solve the following three engineering evaluations:

Modified Eucken Gas Thermal Conductivity: A gas reactor effluent contains pure ethane ( M = 30.07 kg/kmol = 0.03007 kg/mol M = 30.07\text{ kg/kmol} = 0.03007\text{ kg/mol} M = 30.07 kg/kmol = 0.03007 kg/mol ) at 400.0 K 400.0\text{ K} 400.0 K and 1.0 bar 1.0\text{ bar} 1.0 bar . At this condition, dynamic viscosity is μ = 1.250 × 10 − 5 Pa ⋅ s \mu = 1.250 \times 10^{-5}\text{ Pa}\cdot\text{s} μ = 1.250 × 1 0 − 5 Pa ⋅ s and molar heat capacity is C p = 65.80 J / ( mol ⋅ K ) C_p = 65.80\text{ J}/(\text{mol}\cdot\text{K}) C p ​ = 65.80 J / ( mol ⋅ K ) . Estimate the thermal conductivity k k k in W / ( m ⋅ K ) \text{W}/(\text{m}\cdot\text{K}) W / ( m ⋅ K ) and evaluate the Prandtl number Pr \text{Pr} Pr .

Liquid Cooler Comparison: In a shell-and-tube exchanger, compare the heat transfer fluid properties of liquid water at 40 ∘ C 40^\circ\text{C} 4 0 ∘ C ( k = 0.630 W / ( m ⋅ K ) k = 0.630\text{ W}/(\text{m}\cdot\text{K}) k = 0.630 W / ( m ⋅ K ) , μ = 0.653 cP \mu = 0.653\text{ cP} μ = 0.653 cP , C p = 4178 J / ( kg ⋅ K ) C_p = 4178\text{ J}/(\text{kg}\cdot\text{K}) C p ​ = 4178 J / ( kg ⋅ K ) ) against liquid toluene at 40 ∘ C 40^\circ\text{C} 4 0 ∘ C ( k = 0.131 W / ( m ⋅ K ) k = 0.131\text{ W}/(\text{m}\cdot\text{K}) k = 0.131 W / ( m ⋅ K ) , μ = 0.500 cP \mu = 0.500\text{ cP} μ = 0.500 cP , C p = 1750 J / ( kg ⋅ K ) C_p = 1750\text{ J}/(\text{kg}\cdot\text{K}) C p ​ = 1750 J / ( kg ⋅ K ) ). Calculate the Prandtl number for each fluid.

Kopp's Rule Solid Heat Capacity: Estimate the solid molar heat capacity ( C p C_p C p ​ ) and specific heat capacity ( c p c_p c p ​ ) in kJ / ( kg ⋅ K ) \text{kJ}/(\text{kg}\cdot\text{K}) kJ / ( kg ⋅ K ) of an alumina catalyst support, aluminum oxide ( Al 2 O 3 \text{Al}_2\text{O}_3 Al 2 ​ O 3 ​ , M = 101.96 g/mol M = 101.96\text{ g/mol} M = 101.96 g/mol ), at 25.0 ∘ C 25.0^\circ\text{C} 25. 0 ∘ C using Kopp's rule.

Step 1: Ethane Gas Thermal Conductivity & Prandtl Number

Using the modified Eucken correlation: k = μ M ( C p + 1.25 R ) k = \frac{\mu}{M} \left( C_p + 1.25 R \right) k = M μ ​ ( C p ​ + 1.25 R )

Evaluate the energy transport factor: 1.25 R = 1.25 × 8.3145 J / ( mol ⋅ K ) = 10.393 J / ( mol ⋅ K ) 1.25 R = 1.25 \times 8.3145\text{ J}/(\text{mol}\cdot\text{K}) = 10.393\text{ J}/(\text{mol}\cdot\text{K}) 1.25 R = 1.25 × 8.3145 J / ( mol ⋅ K ) = 10.393 J / ( mol ⋅ K ) C p + 1.25 R = 65.80 + 10.393 = 76.193 J / ( mol ⋅ K ) C_p + 1.25 R = 65.80 + 10.393 = 76.193\text{ J}/(\text{mol}\cdot\text{K}) C p ​ + 1.25 R = 65.80 + 10.393 = 76.193 J / ( mol ⋅ K )

Compute the viscosity-to-molar-mass ratio: μ M = 1.250 × 10 − 5 kg / ( m ⋅ s ) 0.03007 kg/mol = 4.15697 × 10 − 4 mol / ( m ⋅ s ) \frac{\mu}{M} = \frac{1.250 \times 10^{-5}\text{ kg}/(\text{m}\cdot\text{s})}{0.03007\text{ kg/mol}} = 4.15697 \times 10^{-4}\text{ mol}/(\text{m}\cdot\text{s}) M μ ​ = 0.03007 kg/mol 1.250 × 1 0 − 5 kg / ( m ⋅ s ) ​ = 4.15697 × 1 0 − 4 mol / ( m ⋅ s )

Calculate thermal conductivity: k = ( 4.15697 × 10 − 4 ) × 76.193 = 0.03167 W / ( m ⋅ K ) k = (4.15697 \times 10^{-4}) \times 76.193 = \mathbf{0.03167\text{ W}/(\text{m}\cdot\text{K})} k = ( 4.15697 × 1 0 − 4 ) × 76.193 = 0.03167 W / ( m ⋅ K )

Compute mass specific heat capacity and Prandtl number: c p = C p M = 65.80 J / ( mol ⋅ K ) 0.03007 kg/mol = 2188.2 J / ( kg ⋅ K ) c_p = \frac{C_p}{M} = \frac{65.80\text{ J}/(\text{mol}\cdot\text{K})}{0.03007\text{ kg/mol}} = 2188.2\text{ J}/(\text{kg}\cdot\text{K}) c p ​ = M C p ​ ​ = 0.03007 kg/mol 65.80 J / ( mol ⋅ K ) ​ = 2188.2 J / ( kg ⋅ K ) Pr = c p μ k = ( 2188.2 J / ( kg ⋅ K ) ) × ( 1.250 × 10 − 5 Pa ⋅ s ) 0.03167 W / ( m ⋅ K ) = 0.027353 0.03167 = 0.864 \text{Pr} = \frac{c_p \mu}{k} = \frac{(2188.2\text{ J}/(\text{kg}\cdot\text{K})) \times (1.250 \times 10^{-5}\text{ Pa}\cdot\text{s})}{0.03167\text{ W}/(\text{m}\cdot\text{K})} = \frac{0.027353}{0.03167} = \mathbf{0.864} Pr = k c p ​ μ ​ = 0.03167 W / ( m ⋅ K ) ( 2188.2 J / ( kg ⋅ K )) × ( 1.250 × 1 0 − 5 Pa ⋅ s ) ​ = 0.03167 0.027353 ​ = 0.864

Step 2: Liquid Water vs. Toluene Prandtl Numbers

Convert dynamic viscosities from centipoise to SI units ( 1 cP = 10 − 3 Pa ⋅ s 1\text{ cP} = 10^{-3}\text{ Pa}\cdot\text{s} 1 cP = 1 0 − 3 Pa ⋅ s ):

Water ( 40 ∘ C 40^\circ\text{C} 4 0 ∘ C ): μ = 0.653 × 10 − 3 Pa ⋅ s \mu = 0.653 \times 10^{-3}\text{ Pa}\cdot\text{s} μ = 0.653 × 1 0 − 3 Pa ⋅ s Pr water = C p μ k = ( 4178 J / ( kg ⋅ K ) ) × ( 0.653 × 10 − 3 Pa ⋅ s ) 0.630 W / ( m ⋅ K ) = 2.7282 0.630 = 4.33 \text{Pr}_{\text{water}} = \frac{C_p \mu}{k} = \frac{(4178\text{ J}/(\text{kg}\cdot\text{K})) \times (0.653 \times 10^{-3}\text{ Pa}\cdot\text{s})}{0.630\text{ W}/(\text{m}\cdot\text{K})} = \frac{2.7282}{0.630} = \mathbf{4.33} Pr water ​ = k C p ​ μ ​ = 0.630 W / ( m ⋅ K ) ( 4178 J / ( kg ⋅ K )) × ( 0.653 × 1 0 − 3 Pa ⋅ s ) ​ = 0.630 2.7282 ​ = 4.33

Toluene ( 40 ∘ C 40^\circ\text{C} 4 0 ∘ C ): μ = 0.500 × 10 − 3 Pa ⋅ s \mu = 0.500 \times 10^{-3}\text{ Pa}\cdot\text{s} μ = 0.500 × 1 0 − 3 Pa ⋅ s Pr toluene = C p μ k = ( 1750 J / ( kg ⋅ K ) ) × ( 0.500 × 10 − 3 Pa ⋅ s ) 0.131 W / ( m ⋅ K ) = 0.875 0.131 = 6.68 \text{Pr}_{\text{toluene}} = \frac{C_p \mu}{k} = \frac{(1750\text{ J}/(\text{kg}\cdot\text{K})) \times (0.500 \times 10^{-3}\text{ Pa}\cdot\text{s})}{0.131\text{ W}/(\text{m}\cdot\text{K})} = \frac{0.875}{0.131} = \mathbf{6.68} Pr toluene ​ = k C p ​ μ ​ = 0.131 W / ( m ⋅ K ) ( 1750 J / ( kg ⋅ K )) × ( 0.500 × 1 0 − 3 Pa ⋅ s ) ​ = 0.131 0.875 ​ = 6.68

(Notice: Even though toluene has lower viscosity than water, its thermal conductivity is almost 5 times lower, causing its Prandtl number to be higher than that of water).

Step 3: Kopp's Rule for Alumina ( Al 2 O 3 \text{Al}_2\text{O}_3 Al 2 ​ O 3 ​ )

Aluminum is a metal (use c p , Al = 26.0 J / ( mol ⋅ K ) c_{p,\text{Al}} = 26.0\text{ J}/(\text{mol}\cdot\text{K}) c p , Al ​ = 26.0 J / ( mol ⋅ K ) ). Oxygen has c p , O = 16.7 J / ( mol ⋅ K ) c_{p,\text{O}} = 16.7\text{ J}/(\text{mol}\cdot\text{K}) c p , O ​ = 16.7 J / ( mol ⋅ K ) .

Applying Kopp's rule for Al 2 O 3 \text{Al}_2\text{O}_3 Al 2 ​ O 3 ​ : C p = 2 × c p , Al + 3 × c p , O = ( 2 × 26.0 ) + ( 3 × 16.7 ) = 52.0 + 50.1 = 102.1 J / ( mol ⋅ K ) C_p = 2 \times c_{p,\text{Al}} + 3 \times c_{p,\text{O}} = (2 \times 26.0) + (3 \times 16.7) = 52.0 + 50.1 = \mathbf{102.1\text{ J}/(\text{mol}\cdot\text{K})} C p ​ = 2 × c p , Al ​ + 3 × c p , O ​ = ( 2 × 26.0 ) + ( 3 × 16.7 ) = 52.0 + 50.1 = 102.1 J / ( mol ⋅ K )

Compute mass specific heat capacity ( M = 101.96 g/mol = 0.10196 kg/mol M = 101.96\text{ g/mol} = 0.10196\text{ kg/mol} M = 101.96 g/mol = 0.10196 kg/mol ): c p = C p M = 102.1 J / ( mol ⋅ K ) 0.10196 kg/mol = 1001.4 J / ( kg ⋅ K ) = 1.001 kJ / ( kg ⋅ K ) c_p = \frac{C_p}{M} = \frac{102.1\text{ J}/(\text{mol}\cdot\text{K})}{0.10196\text{ kg/mol}} = 1001.4\text{ J}/(\text{kg}\cdot\text{K}) = \mathbf{1.001\text{ kJ}/(\text{kg}\cdot\text{K})} c p ​ = M C p ​ ​ = 0.10196 kg/mol 102.1 J / ( mol ⋅ K ) ​ = 1001.4 J / ( kg ⋅ K ) = 1.001 kJ / ( kg ⋅ K )

(Experimental calorimetric value for α − Al 2 O 3 \alpha-\text{Al}_2\text{O}_3 α − Al 2 ​ O 3 ​ at 298 K 298\text{ K} 298 K is 79.0 J / ( mol ⋅ K ) 79.0\text{ J}/(\text{mol}\cdot\text{K}) 79.0 J / ( mol ⋅ K ) ; Kopp's rule provides a rapid, conservative first-order estimate within engineering screening accuracy).

6. Critical PE Exam Traps & Pitfalls

  • Warning
  • Trap 1: The Water Thermal Conductivity Anomaly

Assuming that thermal conductivity decreases with temperature for all liquids will cause you to miss points on the PE exam. Liquid water's thermal conductivity increases with temperature from 0 ∘ C 0^\circ\text{C} 0 ∘ C to 130 ∘ C 130^\circ\text{C} 13 0 ∘ C . For all other standard liquid hydrocarbons (benzene, hexane, ethanol), k k k decreases as temperature rises.

  • Warning
  • Trap 2: Molecular Weight Units in the Modified Eucken Formula

In the modified Eucken correlation k = ( μ / M ) ( C p + 1.25 R ) k = (\mu / M)(C_p + 1.25 R) k = ( μ / M ) ( C p ​ + 1.25 R ) , R R R is in J / ( mol ⋅ K ) \text{J}/(\text{mol}\cdot\text{K}) J / ( mol ⋅ K ) . Therefore, molecular weight M M M must be entered in kg/mol \text{kg/mol} kg/mol (e.g., 0.02805 kg/mol 0.02805\text{ kg/mol} 0.02805 kg/mol for ethylene), NOT g/mol \text{g/mol} g/mol . Entering 28.05 28.05 28.05 will underestimate thermal conductivity by a factor of 1,000.

  • Warning
  • Trap 3: Confusing C p C_p C p ​ and C v C_v C v ​ in Modified Eucken Formulations

Be careful which heat capacity you are using: k = ( μ / M ) ( C p + 1.25 R ) k = (\mu/M)(C_p + 1.25R) k = ( μ / M ) ( C p ​ + 1.25 R ) uses constant-pressure heat capacity C p C_p C p ​ , whereas k = ( μ / M ) ( C v + 2.25 R ) k = (\mu/M)(C_v + 2.25R) k = ( μ / M ) ( C v ​ + 2.25 R ) uses constant-volume heat capacity C v C_v C v ​ . Because C p = C v + R C_p = C_v + R C p ​ = C v ​ + R , adding 1.25 R 1.25R 1.25 R to C v C_v C v ​ instead of C p C_p C p ​ will introduce significant error.