9.2 Effectiveness-NTU Method and Exchanger Rating
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
9.2 Effectiveness-NTU Method and Exchanger Rating
Key Takeaways Explain This Topic AI
The Effectiveness-NTU (epsilon-NTU) method solves heat exchanger rating problems (determining outlet temperatures and heat duty for a known surface area and flow rates) directly and non-iteratively, whereas the LMTD method requires iterative trial-and-error because Delta_T_lm depends on unknown outlet temperatures.
The theoretical maximum heat transfer rate is strictly constrained by the fluid stream possessing the minimum heat capacity rate: Q_max = C_min * (T_h,in - T_c,in), where C = m_dot * Cp and C_min = min(C_h, C_c); the C_min fluid experiences the maximum theoretical temperature change.
Exchanger effectiveness is defined as epsilon = Q / Q_max; for pure countercurrent flow, epsilon = (1 - exp[-NTU*(1 - C_r)]) / (1 - C_r * exp[-NTU*(1 - C_r)]) where capacity ratio C_r = C_min / C_max <= 1.0 and Number of Transfer Units NTU = U * A / C_min.
For phase-change heat exchangers (condensers, reboilers, evaporators), one stream undergoes an isothermal transition where Cp -> infinity, collapsing C_max -> infinity and C_r = 0; under this condition, the effectiveness relation collapses to epsilon = 1 - exp(-NTU) across all flow geometries.
The Number of Transfer Units (NTU = U * A / C_min) is a dimensionless measure of heat exchanger physical size; beyond NTU = 3.0, heat exchangers enter a severe regime of diminishing returns where doubling surface area achieves less than 5% incremental thermal recovery.
Last updated: September 2026
9.2 Effectiveness-NTU Method and Exchanger Rating
In chemical plant operations and on the NCEES PE Chemical Exam , engineers face two fundamentally distinct categories of heat exchanger problems: sizing (design) and rating (performance evaluation) .
In a sizing problem , fluid flow rates and all four terminal temperatures are specified; the engineer uses the Log Mean Temperature Difference (LMTD) method to directly calculate the required heat transfer surface area ( A A A ).
In a rating problem , an existing heat exchanger with a fixed surface area ( A A A ) and known overall heat transfer coefficient ( U U U ) receives streams at specified inlet temperatures ( T h , i n , T c , i n T_{h,in}, T_{c,in} T h , in , T c , in ) and flow rates. The outlet temperatures ( T h , o u t , T c , o u t T_{h,out}, T_{c,out} T h , o u t , T c , o u t ) and heat duty ( Q Q Q ) are unknown.
Attempting to solve a rating problem with the LMTD method leads to tedious, circular trial-and-error: you must guess an outlet temperature, compute LMTD and F F F , calculate Q Q Q , update the outlet temperatures, and repeat until convergence. To eliminate iteration entirely, W. M. Kays and A. L. London formulated the Effectiveness-NTU ( ϵ \epsilon ϵ -NTU) method , which solves rating problems analytically in a single direct sequence.
- 1. Fundamental Definitions of the ϵ \epsilon ϵ -NTU Method
- 1. Heat Capacity Rates ( C h , C c C_h, C_c C h , C c )
The heat capacity rate ( C C C ) represents the thermal energy carried by a flowing stream per degree of temperature change: C h = m ˙ h C p , h , C c = m ˙ c C p , c C_h = \dot{m}_h C_{p,h}, \quad C_c = \dot{m}_c C_{p,c} C h = m ˙ h C p , h , C c = m ˙ c C p , c
Where:
C h , C c C_h, C_c C h , C c = heat capacity rates of hot and cold fluids ( W/K \text{W/K} W/K , kW/K \text{kW/K} kW/K , or Btu/(hr ⋅ ∘ F) \text{Btu/(hr}\cdot^\circ\text{F)} Btu/(hr ⋅ ∘ F) ).
m ˙ \dot{m} m ˙ = mass flow rate ( kg/s \text{kg/s} kg/s or lb/hr \text{lb/hr} lb/hr ).
C p C_p C p = specific heat capacity ( J/(kg ⋅ K) \text{J/(kg}\cdot\text{K)} J/(kg ⋅ K) or Btu/(lb ⋅ ∘ F) \text{Btu/(lb}\cdot^\circ\text{F)} Btu/(lb ⋅ ∘ F) ).
Identify the minimum and maximum heat capacity rates: C m i n = min ( C h , C c ) C_{min} = \min(C_h, C_c) C min = min ( C h , C c ) C m a x = max ( C h , C c ) C_{max} = \max(C_h, C_c) C ma x = max ( C h , C c )
2. Heat Capacity Ratio ( C r C_r C r )
The dimensionless capacity ratio is bounded between 0 0 0 and 1 1 1 : C r = C m i n C m a x ( 0 ≤ C r ≤ 1.0 ) C_r = \frac{C_{min}}{C_{max}} \quad (0 \le C_r \le 1.0) C r = C ma x C min ( 0 ≤ C r ≤ 1.0 )
3. Maximum Theoretical Heat Transfer Rate ( Q m a x Q_{max} Q ma x )
The maximum possible heat duty that could be transferred in an idealized, infinitely long countercurrent heat exchanger is governed strictly by the fluid with the minimum heat capacity rate ( C m i n C_{min} C min ): Q m a x = C m i n ( T h , i n − T c , i n ) Q_{max} = C_{min} (T_{h,in} - T_{c,in}) Q ma x = C min ( T h , in − T c , in )
Important
Why C m i n C_{min} C min Limits Heat Transfer:
The maximum temperature change any fluid can experience is the difference between fluid inlet temperatures: Δ T o v e r a l l = T h , i n − T c , i n \Delta T_{overall} = T_{h,in} - T_{c,in} Δ T o v er a ll = T h , in − T c , in .
From energy balances, Q = C h Δ T h = C c Δ T c Q = C_h \Delta T_h = C_c \Delta T_c Q = C h Δ T h = C c Δ T c . Because energy is conserved, the fluid with the smaller heat capacity rate ( C m i n C_{min} C min ) experiences the larger temperature change ( Δ T m a x = Q / C m i n \Delta T_{max} = Q / C_{min} Δ T ma x = Q / C min ). If the fluid with C m a x C_{max} C ma x were to undergo the full temperature span ( T h , i n − T c , i n ) (T_{h,in} - T_{c,in}) ( T h , in − T c , in ) , the required heat duty would force the temperature of the C m i n C_{min} C min fluid to exceed the inlet temperature of the opposing stream, violating the Second Law of Thermodynamics ! Therefore, C m i n C_{min} C min always dictates Q m a x Q_{max} Q ma x .
4. Heat Exchanger Effectiveness ( ϵ \epsilon ϵ )
Effectiveness ( ϵ \epsilon ϵ ) is the dimensionless ratio of the actual heat transfer rate ( Q Q Q ) to the maximum theoretical heat transfer rate ( Q m a x Q_{max} Q ma x ): ϵ ≡ Q Q m a x = C h ( T h , i n − T h , o u t ) C m i n ( T h , i n − T c , i n ) = C c ( T c , o u t − T c , i n ) C m i n ( T h , i n − T c , i n ) \epsilon \equiv \frac{Q}{Q_{max}} = \frac{C_h (T_{h,in} - T_{h,out})}{C_{min} (T_{h,in} - T_{c,in})} = \frac{C_c (T_{c,out} - T_{c,in})}{C_{min} (T_{h,in} - T_{c,in})} ϵ ≡ Q ma x Q = C min ( T h , in − T c , in ) C h ( T h , in − T h , o u t ) = C min ( T h , in − T c , in ) C c ( T c , o u t − T c , in )
If C h = C m i n C_h = C_{min} C h = C min (hot fluid is limiting): ϵ = T h , i n − T h , o u t T h , i n − T c , i n \epsilon = \frac{T_{h,in} - T_{h,out}}{T_{h,in} - T_{c,in}} ϵ = T h , in − T c , in T h , in − T h , o u t
If C c = C m i n C_c = C_{min} C c = C min (cold fluid is limiting): ϵ = T c , o u t − T c , i n T h , i n − T c , i n \epsilon = \frac{T_{c,out} - T_{c,in}}{T_{h,in} - T_{c,in}} ϵ = T h , in − T c , in T c , o u t − T c , in
Effectiveness is bounded by 0 ≤ ϵ < 1.0 0 \le \epsilon < 1.0 0 ≤ ϵ < 1.0 . Once ϵ \epsilon ϵ is determined from the exchanger geometry and operating conditions, actual duty is calculated immediately as Q = ϵ Q m a x Q = \epsilon Q_{max} Q = ϵ Q ma x .
5. Number of Transfer Units ( NTU \text{NTU} NTU )
The Number of Transfer Units (NTU) is a dimensionless parameter that characterizes the physical thermal size of the heat exchanger relative to the stream's heat capacity: NTU ≡ U ⋅ A C m i n \text{NTU} \equiv \frac{U \cdot A}{C_{min}} NTU ≡ C min U ⋅ A
Where:
U U U = overall heat transfer coefficient ( W/(m 2 ⋅ K) \text{W/(m}^2\cdot\text{K)} W/(m 2 ⋅ K) ).
A A A = total surface area ( m 2 \text{m}^2 m 2 ).
C m i n C_{min} C min = minimum heat capacity rate ( W/K \text{W/K} W/K ).
2. Explicit Analytical Effectiveness Formulas
Effectiveness is a function of flow geometry, NTU \text{NTU} NTU , and C r C_r C r : ϵ = f ( NTU , C r , Flow Arrangement ) \epsilon = f(\text{NTU}, C_r, \text{Flow Arrangement}) ϵ = f ( NTU , C r , Flow Arrangement )
1. Pure Countercurrent Flow
For C r < 1.0 C_r < 1.0 C r < 1.0 : ϵ = 1 − exp [ − NTU ( 1 − C r ) ] 1 − C r exp [ − NTU ( 1 − C r ) ] \epsilon = \frac{1 - \exp\left[-\text{NTU}(1 - C_r)\right]}{1 - C_r \exp\left[-\text{NTU}(1 - C_r)\right]} ϵ = 1 − C r exp [ − NTU ( 1 − C r ) ] 1 − exp [ − NTU ( 1 − C r ) ]
For C r = 1.0 C_r = 1.0 C r = 1.0 (Balanced Exchanger, C h = C c C_h = C_c C h = C c ) : ϵ = NTU 1 + NTU \epsilon = \frac{\text{NTU}}{1 + \text{NTU}} ϵ = 1 + NTU NTU
Inverse Formula (Sizing Area from Desired Effectiveness) : NTU = 1 1 − C r ln [ 1 − ϵ C r 1 − ϵ ] ( C r < 1.0 ) \text{NTU} = \frac{1}{1 - C_r} \ln\left[ \frac{1 - \epsilon C_r}{1 - \epsilon} \right] \quad (C_r < 1.0) NTU = 1 − C r 1 ln [ 1 − ϵ 1 − ϵ C r ] ( C r < 1.0 ) NTU = ϵ 1 − ϵ ( C r = 1.0 ) \text{NTU} = \frac{\epsilon}{1 - \epsilon} \quad (C_r = 1.0) NTU = 1 − ϵ ϵ ( C r = 1.0 )
2. Pure Cocurrent / Parallel Flow ϵ = 1 − exp [ − NTU ( 1 + C r ) ] 1 + C r \epsilon = \frac{1 - \exp\left[-\text{NTU}(1 + C_r)\right]}{1 + C_r} ϵ = 1 + C r 1 − exp [ − NTU ( 1 + C r ) ] NTU = − ln [ 1 − ϵ ( 1 + C r ) ] 1 + C r \text{NTU} = -\frac{\ln\left[ 1 - \epsilon(1 + C_r) \right]}{1 + C_r} NTU = − 1 + C r ln [ 1 − ϵ ( 1 + C r ) ]
Note
The Parallel Flow 50% Limit:
As surface area approaches infinity ( NTU → ∞ \text{NTU} \to \infty NTU → ∞ ), the exponential term exp [ − NTU ( 1 + C r ) ] → 0 \exp[-\text{NTU}(1+C_r)] \to 0 exp [ − NTU ( 1 + C r )] → 0 .
Consequently, the maximum possible effectiveness for parallel flow is: ϵ m a x , parallel = 1 1 + C r \epsilon_{max, \text{parallel}} = \frac{1}{1 + C_r} ϵ ma x , parallel = 1 + C r 1 When fluid heat capacities are balanced ( C r = 1.0 C_r = 1.0 C r = 1.0 ), ϵ m a x = 1 / ( 1 + 1 ) = 0.50 \epsilon_{max} = 1 / (1 + 1) = 0.50 ϵ ma x = 1/ ( 1 + 1 ) = 0.50 ( 50 % 50\% 50% ). In parallel flow, fluid streams can never exchange more than half the maximum theoretical heat because they approach a common intermediate equilibrium temperature!
3. Shell-and-Tube Exchangers (1 Shell Pass, 2 , 4 , 6 , … 2, 4, 6, \dots 2 , 4 , 6 , … Tube Passes)
For a TEMA 1-2 shell-and-tube exchanger: ϵ 1 = 2 [ 1 + C r + 1 + C r 2 ⋅ 1 + exp ( − NTU 1 + C r 2 ) 1 − exp ( − NTU 1 + C r 2 ) ] − 1 \epsilon_1 = 2 \left[ 1 + C_r + \sqrt{1 + C_r^2} \cdot \frac{1 + \exp\left(-\text{NTU} \sqrt{1 + C_r^2}\right)}{1 - \exp\left(-\text{NTU} \sqrt{1 + C_r^2}\right)} \right]^{-1} ϵ 1 = 2 1 + C r + 1 + C r 2 ⋅ 1 − exp ( − NTU 1 + C r 2 ) 1 + exp ( − NTU 1 + C r 2 ) − 1
For n n n identical shell passes in series (each shell containing an even number of tube passes): ϵ = [ 1 − ϵ 1 C r 1 − ϵ 1 ] n − 1 [ 1 − ϵ 1 C r 1 − ϵ 1 ] n − C r \epsilon = \frac{\left[ \frac{1 - \epsilon_1 C_r}{1 - \epsilon_1} \right]^n - 1}{\left[ \frac{1 - \epsilon_1 C_r}{1 - \epsilon_1} \right]^n - C_r} ϵ = [ 1 − ϵ 1 1 − ϵ 1 C r ] n − C r [ 1 − ϵ 1 1 − ϵ 1 C r ] n − 1
4. Crossflow Exchangers (Air Coolers, Fin-Fan Exchangers)
Both Fluids Unmixed (e.g., plate-fin or finned-tube radiators): ϵ = 1 − exp { NTU 0.22 C r [ exp ( − C r ⋅ NTU 0.78 ) − 1 ] } \epsilon = 1 - \exp\left\{ \frac{\text{NTU}^{0.22}}{C_r} \left[ \exp\left(-C_r \cdot \text{NTU}^{0.78}\right) - 1 \right] \right\} ϵ = 1 − exp { C r NTU 0.22 [ exp ( − C r ⋅ NTU 0.78 ) − 1 ] }
C m a x C_{max} C ma x Mixed, C m i n C_{min} C min Unmixed : ϵ = 1 C r ( 1 − exp { − C r [ 1 − exp ( − NTU ) ] } ) \epsilon = \frac{1}{C_r} \left( 1 - \exp\left\{ -C_r \left[ 1 - \exp(-\text{NTU}) \right] \right\} \right) ϵ = C r 1 ( 1 − exp { − C r [ 1 − exp ( − NTU ) ] } )
C m i n C_{min} C min Mixed, C m a x C_{max} C ma x Unmixed : ϵ = 1 − exp { − 1 C r [ 1 − exp ( − C r ⋅ NTU ) ] } \epsilon = 1 - \exp\left\{ -\frac{1}{C_r} \left[ 1 - \exp(-C_r \cdot \text{NTU}) \right] \right\} ϵ = 1 − exp { − C r 1 [ 1 − exp ( − C r ⋅ NTU ) ] }
3. Phase Change Heat Exchangers ( C r = 0 C_r = 0 C r = 0 )
In condensers, reboilers, evaporators, and steam heaters, one process stream undergoes an isothermal phase transition ( T = constant T = \text{constant} T = constant ). Thermodynamically, the effective heat capacity of a boiling or condensing fluid is infinite: C p = ( ∂ H ∂ T ) P → ∞ ⟹ C m a x → ∞ C_p = \left( \frac{\partial H}{\partial T} \right)_P \to \infty \implies C_{max} \to \infty C p = ( ∂ T ∂ H ) P → ∞ ⟹ C ma x → ∞
Therefore, the heat capacity ratio is identically zero: C r = C m i n C m a x = C m i n ∞ = 0 C_r = \frac{C_{min}}{C_{max}} = \frac{C_{min}}{\infty} = \mathbf{0} C r = C ma x C min = ∞ C min = 0
Substituting C r = 0 C_r = 0 C r = 0 into the effectiveness formulas for all heat exchanger configurations (counterflow, parallel flow, shell-and-tube, and crossflow) collapses the equations into a single universal relationship: ϵ = 1 − exp ( − NTU ) \epsilon = 1 - \exp(-\text{NTU}) ϵ = 1 − exp ( − NTU ) NTU = − ln ( 1 − ϵ ) \text{NTU} = -\ln(1 - \epsilon) NTU = − ln ( 1 − ϵ )
Tip
The C r = 0 C_r = 0 C r = 0 Shortcut on the PE Exam:
Whenever an exam question involves steam condensation or liquid vaporization, flow arrangement is completely irrelevant! Counterflow, parallel flow, and shell-and-tube all yield the identical effectiveness: ϵ = 1 − e − NTU \epsilon = 1 - e^{-\text{NTU}} ϵ = 1 − e − NTU .
4. Summary Table of Effectiveness-NTU Relations across Flow Configurations
Configuration Effectiveness ϵ = f ( NTU , C r ) \epsilon = f(\text{NTU}, C_r) ϵ = f ( NTU , C r ) Inverse Sizing NTU = f ( ϵ , C r ) \text{NTU} = f(\epsilon, C_r) NTU = f ( ϵ , C r ) Asymptotic Limit as NTU → ∞ \text{NTU} \to \infty NTU → ∞
Pure Counterflow ( C r < 1 C_r < 1 C r < 1 ) 1 − exp [ − NTU ( 1 − C r ) ] 1 − C r exp [ − NTU ( 1 − C r ) ] \frac{1 - \exp[-\text{NTU}(1 - C_r)]}{1 - C_r \exp[-\text{NTU}(1 - C_r)]} 1 − C r e x p [ − NTU ( 1 − C r )] 1 − e x p [ − NTU ( 1 − C r )] 1 1 − C r ln [ 1 − ϵ C r 1 − ϵ ] \frac{1}{1 - C_r} \ln\left[\frac{1 - \epsilon C_r}{1 - \epsilon}\right] 1 − C r 1 ln [ 1 − ϵ 1 − ϵ C r ] ϵ → 1.00 \epsilon \to 1.00 ϵ → 1.00 ( 100 % 100\% 100% recovery)
Pure Counterflow ( C r = 1 C_r = 1 C r = 1 ) NTU 1 + NTU \frac{\text{NTU}}{1 + \text{NTU}} 1 + NTU NTU ϵ 1 − ϵ \frac{\epsilon}{1 - \epsilon} 1 − ϵ ϵ ϵ → 1.00 \epsilon \to 1.00 ϵ → 1.00
Pure Parallel Flow 1 − exp [ − NTU ( 1 + C r ) ] 1 + C r \frac{1 - \exp[-\text{NTU}(1 + C_r)]}{1 + C_r} 1 + C r 1 − e x p [ − NTU ( 1 + C r )] − ln [ 1 − ϵ ( 1 + C r ) ] 1 + C r -\frac{\ln[1 - \epsilon(1 + C_r)]}{1 + C_r} − 1 + C r l n [ 1 − ϵ ( 1 + C r )] ϵ → 1 1 + C r ≤ 0.50 \epsilon \to \frac{1}{1 + C_r} \le 0.50 ϵ → 1 + C r 1 ≤ 0.50 (for C r = 1 C_r=1 C r = 1 )
Phase Change ( C r = 0 C_r = 0 C r = 0 ) 1 − exp ( − NTU ) 1 - \exp(-\text{NTU}) 1 − exp ( − NTU ) − ln ( 1 − ϵ ) -\ln(1 - \epsilon) − ln ( 1 − ϵ ) ϵ → 1.00 \epsilon \to 1.00 ϵ → 1.00 (all geometries)
1-2 Shell & Tube 2 [ 1 + C r + 1 + C r 2 1 + e − NTU 1 + C r 2 1 − e − NTU 1 + C r 2 ] − 1 2 \left[ 1 + C_r + \sqrt{1+C_r^2} \frac{1 + e^{-\text{NTU}\sqrt{1+C_r^2}}}{1 - e^{-\text{NTU}\sqrt{1+C_r^2}}} \right]^{-1} 2 [ 1 + C r + 1 + C r 2 1 − e − NTU 1 + C r 2 1 + e − NTU 1 + C r 2 ] − 1 − 1 1 + C r 2 ln [ 2 / ϵ 1 − 1 − C r − 1 + C r 2 2 / ϵ 1 − 1 − C r + 1 + C r 2 ] -\frac{1}{\sqrt{1+C_r^2}} \ln\left[ \frac{2/\epsilon_1 - 1 - C_r - \sqrt{1+C_r^2}}{2/\epsilon_1 - 1 - C_r + \sqrt{1+C_r^2}} \right] − 1 + C r 2 1 ln [ 2/ ϵ 1 − 1 − C r + 1 + C r 2 2/ ϵ 1 − 1 − C r − 1 + C r 2 ] ϵ → 2 1 + C r + 1 + C r 2 < 1.0 \epsilon \to \frac{2}{1 + C_r + \sqrt{1+C_r^2}} < 1.0 ϵ → 1 + C r + 1 + C r 2 2 < 1.0
5. Systematic Exchanger Rating Algorithm (Step-by-Step)
To rate an existing heat exchanger on the PE Chemical exam, follow this rigorous 7-step sequence: [Step 1: Calculate C_h & C_c] ---> [Step 2: Find C_min, C_max, C_r] ---> [Step 3: Compute Q_max]
- |
- [Step 6: Compute Actual Q] <--- [Step 5: Calculate epsilon] <--- [Step 4: Compute NTU]
- |
- v
- [Step 7: Solve Outlet Temps (T_h,out & T_c,out)]
Compute heat capacity rates : C h = m ˙ h C p , h C_h = \dot{m}_h C_{p,h} C h = m ˙ h C p , h and C c = m ˙ c C p , c C_c = \dot{m}_c C_{p,c} C c = m ˙ c C p , c .
Identify extremes : Determine C m i n , C m a x C_{min}, C_{max} C min , C ma x , and compute C r = C m i n / C m a x C_r = C_{min} / C_{max} C r = C min / C ma x .
Calculate maximum heat duty : Q m a x = C m i n ( T h , i n − T c , i n ) Q_{max} = C_{min} (T_{h,in} - T_{c,in}) Q ma x = C min ( T h , in − T c , in ) .
Evaluate Number of Transfer Units : NTU = U A / C m i n \text{NTU} = U A / C_{min} NTU = U A / C min .
Evaluate effectiveness ϵ \epsilon ϵ using the analytical relation corresponding to the exchanger flow arrangement.
Determine operating heat duty : Q = ϵ ⋅ Q m a x Q = \epsilon \cdot Q_{max} Q = ϵ ⋅ Q ma x .
Solve for stream outlet temperatures using straightforward energy balances: T h , o u t = T h , i n − Q C h T_{h,out} = T_{h,in} - \frac{Q}{C_h} T h , o u t = T h , in − C h Q T c , o u t = T c , i n + Q C c T_{c,out} = T_{c,in} + \frac{Q}{C_c} T c , o u t = T c , in + C c Q
- 6. Comprehensive Worked Numerical Example: Rating an Industrial Effluent Heat Recovery Exchanger
- Problem Statement
A chemical synthesis plant utilizes an existing countercurrent plate-and-frame heat exchanger to recover waste heat from a hot aqueous effluent stream to preheat cold boiler feedwater.
Exchanger and Stream Operating Data:
Exchanger surface area: A = 45.0 m 2 A = 45.0\text{ m}^2 A = 45.0 m 2
Overall heat transfer coefficient: U = 1 , 250 W/(m 2 ⋅ K) U = 1,250\text{ W/(m}^2\cdot\text{K)} U = 1 , 250 W/(m 2 ⋅ K)
Hot Effluent Stream: enters at T h , i n = 95.0 ∘ C T_{h,in} = 95.0^\circ\text{C} T h , in = 95. 0 ∘ C with mass flow rate m ˙ h = 12.0 kg/s \dot{m}_h = 12.0\text{ kg/s} m ˙ h = 12.0 kg/s , C p , h = 3.80 kJ/(kg ⋅ K) C_{p,h} = 3.80\text{ kJ/(kg}\cdot\text{K)} C p , h = 3.80 kJ/(kg ⋅ K)
Cold Boiler Feedwater: enters at T c , i n = 20.0 ∘ C T_{c,in} = 20.0^\circ\text{C} T c , in = 20. 0 ∘ C with mass flow rate m ˙ c = 8.0 kg/s \dot{m}_c = 8.0\text{ kg/s} m ˙ c = 8.0 kg/s , C p , c = 4.19 kJ/(kg ⋅ K) C_{p,c} = 4.19\text{ kJ/(kg}\cdot\text{K)} C p , c = 4.19 kJ/(kg ⋅ K)
Calculate:
The heat capacity rates C h C_h C h and C c C_c C c , identifying C m i n C_{min} C min and capacity ratio C r C_r C r .
The maximum theoretical heat transfer rate ( Q m a x Q_{max} Q ma x ) in kW \text{kW} kW .
The Number of Transfer Units ( NTU \text{NTU} NTU ).
The thermal effectiveness ( ϵ \epsilon ϵ ) of the countercurrent exchanger.
The actual steady-state operating heat transfer rate ( Q Q Q ) in kW \text{kW} kW .
The outlet temperatures of both process streams ( T h , o u t T_{h,out} T h , o u t and T c , o u t T_{c,out} T c , o u t ).
Verify the solution by calculating Δ T l m \Delta T_{lm} Δ T l m and confirming that Q = U A Δ T l m Q = U A \Delta T_{lm} Q = U A Δ T l m .
Step 1: Heat Capacity Rates and C r C_r C r
Hot fluid capacity rate: C h = m ˙ h C p , h = ( 12.0 kg/s ) × ( 3.80 kJ/(kg ⋅ K) ) = 45.60 kW/K = 45 , 600 W/K C_h = \dot{m}_h C_{p,h} = (12.0\text{ kg/s}) \times (3.80\text{ kJ/(kg}\cdot\text{K)}) = \mathbf{45.60\text{ kW/K}} = 45,600\text{ W/K} C h = m ˙ h C p , h = ( 12.0 kg/s ) × ( 3.80 kJ/(kg ⋅ K) ) = 45.60 kW/K = 45 , 600 W/K
Cold fluid capacity rate: C c = m ˙ c C p , c = ( 8.0 kg/s ) × ( 4.19 kJ/(kg ⋅ K) ) = 33.52 kW/K = 33 , 520 W/K C_c = \dot{m}_c C_{p,c} = (8.0\text{ kg/s}) \times (4.19\text{ kJ/(kg}\cdot\text{K)}) = \mathbf{33.52\text{ kW/K}} = 33,520\text{ W/K} C c = m ˙ c C p , c = ( 8.0 kg/s ) × ( 4.19 kJ/(kg ⋅ K) ) = 33.52 kW/K = 33 , 520 W/K
Comparing rates: C m i n = C c = 33.520 kW/K = 33 , 520 W/K C_{min} = C_c = \mathbf{33.520\text{ kW/K}} = \mathbf{33,520\text{ W/K}} C min = C c = 33.520 kW/K = 33 , 520 W/K C m a x = C h = 45.600 kW/K = 45 , 600 W/K C_{max} = C_h = \mathbf{45.600\text{ kW/K}} = \mathbf{45,600\text{ W/K}} C ma x = C h = 45.600 kW/K = 45 , 600 W/K
Heat capacity ratio: C r = C m i n C m a x = 33 , 520 W/K 45 , 600 W/K = 0.73509 C_r = \frac{C_{min}}{C_{max}} = \frac{33,520\text{ W/K}}{45,600\text{ W/K}} = \mathbf{0.73509} C r = C ma x C min = 45 , 600 W/K 33 , 520 W/K = 0.73509
Step 2: Maximum Theoretical Heat Duty Q m a x = C m i n ( T h , i n − T c , i n ) Q_{max} = C_{min} (T_{h,in} - T_{c,in}) Q ma x = C min ( T h , in − T c , in ) Q m a x = ( 33.520 kW/K ) × ( 95.0 ∘ C − 20.0 ∘ C ) = 33.520 × 75.0 = 2 , 514.0 kW Q_{max} = (33.520\text{ kW/K}) \times (95.0^\circ\text{C} - 20.0^\circ\text{C}) = 33.520 \times 75.0 = \mathbf{2,514.0\text{ kW}} Q ma x = ( 33.520 kW/K ) × ( 95. 0 ∘ C − 20. 0 ∘ C ) = 33.520 × 75.0 = 2 , 514.0 kW
Step 3: Number of Transfer Units ( NTU \text{NTU} NTU ) NTU = U ⋅ A C m i n = ( 1 , 250 W/(m 2 ⋅ K) ) × ( 45.0 m 2 ) 33 , 520 W/K = 56 , 250 W/K 33 , 520 W/K = 1.6781 \text{NTU} = \frac{U \cdot A}{C_{min}} = \frac{(1,250\text{ W/(m}^2\cdot\text{K)}) \times (45.0\text{ m}^2)}{33,520\text{ W/K}} = \frac{56,250\text{ W/K}}{33,520\text{ W/K}} = \mathbf{1.6781} NTU = C min U ⋅ A = 33 , 520 W/K ( 1 , 250 W/(m 2 ⋅ K) ) × ( 45.0 m 2 ) = 33 , 520 W/K 56 , 250 W/K = 1.6781
Step 4: Exchanger Thermal Effectiveness ( ϵ \epsilon ϵ )
For pure countercurrent flow with C r = 0.73509 < 1.0 C_r = 0.73509 < 1.0 C r = 0.73509 < 1.0 : ϵ = 1 − exp [ − NTU ( 1 − C r ) ] 1 − C r exp [ − NTU ( 1 − C r ) ] \epsilon = \frac{1 - \exp\left[-\text{NTU}(1 - C_r)\right]}{1 - C_r \exp\left[-\text{NTU}(1 - C_r)\right]} ϵ = 1 − C r exp [ − NTU ( 1 − C r ) ] 1 − exp [ − NTU ( 1 − C r ) ]
Evaluate exponent argument: NTU ( 1 − C r ) = 1.6781 × ( 1 − 0.73509 ) = 1.6781 × 0.26491 = 0.44455 \text{NTU}(1 - C_r) = 1.6781 \times (1 - 0.73509) = 1.6781 \times 0.26491 = \mathbf{0.44455} NTU ( 1 − C r ) = 1.6781 × ( 1 − 0.73509 ) = 1.6781 × 0.26491 = 0.44455 exp ( − 0.44455 ) = 0.64111 \exp(-0.44455) = \mathbf{0.64111} exp ( − 0.44455 ) = 0.64111
Numerator: Num = 1 − 0.64111 = 0.35889 \text{Num} = 1 - 0.64111 = \mathbf{0.35889} Num = 1 − 0.64111 = 0.35889
Denominator: Den = 1 − C r exp ( − 0.44455 ) = 1 − ( 0.73509 × 0.64111 ) = 1 − 0.47127 = 0.52873 \text{Den} = 1 - C_r \exp(-0.44455) = 1 - (0.73509 \times 0.64111) = 1 - 0.47127 = \mathbf{0.52873} Den = 1 − C r exp ( − 0.44455 ) = 1 − ( 0.73509 × 0.64111 ) = 1 − 0.47127 = 0.52873
Effectiveness: ϵ = 0.35889 0.52873 = 0.67878 ≈ 0.6788 ( 67.88 % ) \epsilon = \frac{0.35889}{0.52873} = \mathbf{0.67878} \approx \mathbf{0.6788} \quad (67.88\%) ϵ = 0.52873 0.35889 = 0.67878 ≈ 0.6788 ( 67.88% )
Step 5: Actual Operating Heat Duty ( Q Q Q ) Q = ϵ ⋅ Q m a x = 0.67878 × 2 , 514.0 kW = 1 , 706.45 kW ≈ 1 , 706.5 kW Q = \epsilon \cdot Q_{max} = 0.67878 \times 2,514.0\text{ kW} = \mathbf{1,706.45\text{ kW}} \approx \mathbf{1,706.5\text{ kW}} Q = ϵ ⋅ Q ma x = 0.67878 × 2 , 514.0 kW = 1 , 706.45 kW ≈ 1 , 706.5 kW
Step 6: Stream Outlet Temperatures
Hot effluent exit temperature: T h , o u t = T h , i n − Q C h = 95.0 ∘ C − 1 , 706.45 kW 45.60 kW/K = 95.0 − 37.42 = 57.58 ∘ C T_{h,out} = T_{h,in} - \frac{Q}{C_h} = 95.0^\circ\text{C} - \frac{1,706.45\text{ kW}}{45.60\text{ kW/K}} = 95.0 - 37.42 = \mathbf{57.58^\circ\text{C}} T h , o u t = T h , in − C h Q = 95. 0 ∘ C − 45.60 kW/K 1 , 706.45 kW = 95.0 − 37.42 = 57.5 8 ∘ C
Cold boiler feedwater exit temperature: T c , o u t = T c , i n + Q C c = 20.0 ∘ C + 1 , 706.45 kW 33.52 kW/K = 20.0 + 50.91 = 70.91 ∘ C T_{c,out} = T_{c,in} + \frac{Q}{C_c} = 20.0^\circ\text{C} + \frac{1,706.45\text{ kW}}{33.52\text{ kW/K}} = 20.0 + 50.91 = \mathbf{70.91^\circ\text{C}} T c , o u t = T c , in + C c Q = 20. 0 ∘ C + 33.52 kW/K 1 , 706.45 kW = 20.0 + 50.91 = 70.9 1 ∘ C
Notice that T c , o u t ( 70.91 ∘ C ) > T h , o u t ( 57.58 ∘ C ) T_{c,out} (70.91^\circ\text{C}) > T_{h,out} (57.58^\circ\text{C}) T c , o u t ( 70.9 1 ∘ C ) > T h , o u t ( 57.5 8 ∘ C ) —a significant temperature cross of 13.33 ∘ C 13.33^\circ\text{C} 13.3 3 ∘ C , which is fully achievable because plate-and-frame exchangers operate in pure countercurrent flow!
Step 7: LMTD Cross-Verification
Terminal temperature differences: Δ T 1 = T h , i n − T c , o u t = 95.0 ∘ C − 70.91 ∘ C = 24.09 ∘ C \Delta T_1 = T_{h,in} - T_{c,out} = 95.0^\circ\text{C} - 70.91^\circ\text{C} = 24.09^\circ\text{C} Δ T 1 = T h , in − T c , o u t = 95. 0 ∘ C − 70.9 1 ∘ C = 24.0 9 ∘ C Δ T 2 = T h , o u t − T c , i n = 57.58 ∘ C − 20.0 ∘ C = 37.58 ∘ C \Delta T_2 = T_{h,out} - T_{c,in} = 57.58^\circ\text{C} - 20.0^\circ\text{C} = 37.58^\circ\text{C} Δ T 2 = T h , o u t − T c , in = 57.5 8 ∘ C − 20. 0 ∘ C = 37.5 8 ∘ C Δ T l m = 37.58 − 24.09 ln ( 37.58 / 24.09 ) = 13.49 ln ( 1.5600 ) = 13.49 0.44469 = 30.336 ∘ C \Delta T_{lm} = \frac{37.58 - 24.09}{\ln(37.58 / 24.09)} = \frac{13.49}{\ln(1.5600)} = \frac{13.49}{0.44469} = \mathbf{30.336^\circ\text{C}} Δ T l m = ln ( 37.58/24.09 ) 37.58 − 24.09 = ln ( 1.5600 ) 13.49 = 0.44469 13.49 = 30.33 6 ∘ C
Recalculating heat duty via LMTD ( F = 1.00 F = 1.00 F = 1.00 for countercurrent): Q = U ⋅ A ⋅ Δ T l m = ( 1 , 250 W/(m 2 ⋅ K) ) × ( 45.0 m 2 ) × ( 30.336 K ) Q = U \cdot A \cdot \Delta T_{lm} = (1,250\text{ W/(m}^2\cdot\text{K)}) \times (45.0\text{ m}^2) \times (30.336\text{ K}) Q = U ⋅ A ⋅ Δ T l m = ( 1 , 250 W/(m 2 ⋅ K) ) × ( 45.0 m 2 ) × ( 30.336 K ) Q = 56 , 250 × 30.336 = 1 , 706 , 400 W = 1 , 706.4 kW Q = 56,250 \times 30.336 = 1,706,400\text{ W} = \mathbf{1,706.4\text{ kW}} Q = 56 , 250 × 30.336 = 1 , 706 , 400 W = 1 , 706.4 kW
(The calculation closes with 100.00 % 100.00\% 100.00% precision, proving exact analytical consistency between the two methods).
- 7. Critical PE Exam Traps & Pitfalls
- Trap 1: Calculating Q m a x Q_{max} Q ma x Using C m a x C_{max} C ma x Instead of C m i n C_{min} C min
A catastrophic exam error is evaluating Q m a x = C m a x ( T h , i n − T c , i n ) Q_{max} = C_{max} (T_{h,in} - T_{c,in}) Q ma x = C ma x ( T h , in − T c , in ) . Doing so violates the First Law of Thermodynamics: if you transfer that much heat, the temperature change of the C m i n C_{min} C min stream would exceed ( T h , i n − T c , i n ) (T_{h,in} - T_{c,in}) ( T h , in − T c , in ) , meaning a cold stream would exit hotter than the entering hot stream could ever supply. Always use C m i n C_{min} C min to establish Q m a x Q_{max} Q ma x .
Trap 2: Neglecting the C r = 0 C_r = 0 C r = 0 Simplification in Phase Change Operations
When an exam question specifies a boiler, evaporator, or condenser, do not attempt to calculate the mass flow rate times liquid heat capacity for the phase-changing stream! Because latent heat transfer occurs at constant temperature, C m a x → ∞ C_{max} \to \infty C ma x → ∞ and C r = 0 C_r = 0 C r = 0 . The effectiveness collapses immediately to ϵ = 1 − exp ( − NTU ) \epsilon = 1 - \exp(-\text{NTU}) ϵ = 1 − exp ( − NTU ) for all configurations.
Trap 3: The Economic Law of Diminishing Returns for NTU > 3.0 \text{NTU} > 3.0 NTU > 3.0
Heat exchanger surface area scales linearly with NTU \text{NTU} NTU ( A = NTU ⋅ C m i n / U A = \text{NTU} \cdot C_{min} / U A = NTU ⋅ C min / U ), but effectiveness scales asymptotically ( 1 − e − NTU \,1 - e^{-\text{NTU}} 1 − e − NTU ). For NTU = 1.0 \text{NTU} = 1.0 NTU = 1.0 , ϵ ≈ 63 % \epsilon \approx 63\% ϵ ≈ 63% ; for NTU = 3.0 \text{NTU} = 3.0 NTU = 3.0 , ϵ ≈ 95 % \epsilon \approx 95\% ϵ ≈ 95% . Increasing NTU \text{NTU} NTU from 3.0 3.0 3.0 to 6.0 6.0 6.0 doubles the capital cost of the heat exchanger but yields less than 4 % 4\% 4% in additional heat recovery. On process optimization exam questions, sizing an exchanger for NTU > 3.5 \text{NTU} > 3.5 NTU > 3.5 is rarely economically justified.