Study guide

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD

PE Chemical Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the PE Chemical Exam How to Use This Guide and the NCEES Handbook

2 Chapter 1: Material Balances & Flowsheet Calculations

1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations

3 Chapter 2: Energy Balances & Thermochemistry

2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances

4 Chapter 3: Fluid Statics & Incompressible Pipe Flow

3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations

5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow

4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up

6 Chapter 5: Thermodynamic Laws & Fundamental Relations

5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations

7 Chapter 6: Real Gases & Equations of State

6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions

8 Chapter 7: Phase & Chemical Reaction Equilibria

7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation

9 Chapter 8: Heat Transfer Mechanisms & Conduction

8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange

10 Chapter 9: Heat Exchanger Design & Phase Change

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances

11 Chapter 10: Mass Transfer Fundamentals & Diffusion

10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)

12 Chapter 11: Distillation Operations

11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components

13 Chapter 12: Rate-Controlled & Equilibrium Separations

12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations

14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors

13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations

15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis

14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models

16 Chapter 15: Physical & Transport Properties of Fluids

15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles

17 Chapter 16: Materials of Construction & Corrosion

16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention

18 Chapter 17: Process Safety & Pressure Relief Systems

17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment

19 Chapter 18: Process Control & Engineering Economics

18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems

20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance

19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation

21 Chapter 20: Plant Operation, Reliability & Continuous Improvement

20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD

Key Takeaways Explain This Topic AI

The universal sizing equation for shell-and-tube heat exchangers is Q = U * A * Delta_T_lm * F, where F <= 1.0 is the LMTD correction factor accounting for crossflow passes, baffle geometry, and mixed/unmixed flow relative to true counterflow.

Log Mean Temperature Difference (LMTD = (Delta_T1 - Delta_T2) / ln(Delta_T1 / Delta_T2)) represents the exact logarithmic driving force for pure countercurrent flow; when terminal temperature differences are within 50% (Delta_T1 / Delta_T2 <= 1.5), the arithmetic mean approximates LMTD within 1%.

TEMA standard designations use a three-letter code specifying Stationary Front Head (A, B, C, D), Shell Type (E, F, G, H, J, K, X), and Rear Head (L, M, N, P, S, T, U, W); e.g., TEMA AES features a removable channel with cover, single-pass shell, and floating head with backing device.

Tube pitch geometries dictate compactness and cleanability: 30-degree and 60-degree triangular pitches maximize heat transfer coefficient and surface density (15% more tubes per shell) but require chemical cleaning, whereas 90-degree square and 45-degree rotated square pitches provide continuous cleaning lanes (>= 0.25 in or 6.35 mm) for mechanical fouling removal.

The LMTD correction factor F is evaluated as a function of thermal effectiveness P = (t2 - t1) / (T1 - t1) and heat capacity rate ratio R = (T1 - T2) / (t2 - t1); designs where F drops below 0.75-0.80 are operationally unstable and thermodynamically invalid, necessitating multiple shells in series to resolve temperature crosses (t2 > T2).

Last updated: September 2026

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD

On the NCEES PE Chemical Exam , heat transfer questions frequently focus on the design, rating, and mechanical selection of shell-and-tube heat exchangers . Whether evaluating crude preheat trains, reactor effluent coolers, or reboilers, the chemical engineer must translate process flow rates and thermal duties into required surface areas while balancing shell-side pressure drop, tube bundle cleanability, and thermal stress. The governing analytical framework combines the overall heat transfer equation , the Log Mean Temperature Difference (LMTD) , and the LMTD correction factor ( F F F ) derived from TEMA (Tubular Exchanger Manufacturers Association) standards.

1. Overall Heat Transfer Equation & The Log Mean Temperature Difference (LMTD)

At steady state, the total thermal duty ( Q Q Q ) exchanged between a hot process stream and a cold utility or process stream is governed by the energy conservation balance: Q = m ˙ h C p , h ( T h , i n − T h , o u t ) = m ˙ c C p , c ( T c , o u t − T c , i n ) Q = \dot{m}_h C_{p,h} (T_{h,in} - T_{h,out}) = \dot{m}_c C_{p,c} (T_{c,out} - T_{c,in}) Q = m ˙ h ​ C p , h ​ ( T h , in ​ − T h , o u t ​ ) = m ˙ c ​ C p , c ​ ( T c , o u t ​ − T c , in ​ )

Where:

m ˙ h , m ˙ c \dot{m}_h, \dot{m}_c m ˙ h ​ , m ˙ c ​ = mass flow rates of hot and cold fluids ( kg/s \text{kg/s} kg/s or lb/h \text{lb/h} lb/h ).

C p , h , C p , c C_{p,h}, C_{p,c} C p , h ​ , C p , c ​ = mean isobaric specific heat capacities ( kJ/(kg ⋅ K) \text{kJ/(kg}\cdot\text{K)} kJ/(kg ⋅ K) or Btu/(lb ⋅ ∘ F) \text{Btu/(lb}\cdot^\circ\text{F)} Btu/(lb ⋅ ∘ F) ).

T h , i n , T h , o u t T_{h,in}, T_{h,out} T h , in ​ , T h , o u t ​ = hot fluid inlet and outlet temperatures ( ∘ C ^\circ\text{C} ∘ C or ∘ F ^\circ\text{F} ∘ F ).

T c , i n , T c , o u t T_{c,in}, T_{c,out} T c , in ​ , T c , o u t ​ = cold fluid inlet and outlet temperatures ( ∘ C ^\circ\text{C} ∘ C or ∘ F ^\circ\text{F} ∘ F ).

The rate of heat transfer through the exchanger surface area ( A A A ) is given by: Q = U ⋅ A ⋅ Δ T l m ⋅ F Q = U \cdot A \cdot \Delta T_{lm} \cdot F Q = U ⋅ A ⋅ Δ T l m ​ ⋅ F

Where:

U U U = overall heat transfer coefficient ( W/(m 2 ⋅ K) \text{W/(m}^2\cdot\text{K)} W/(m 2 ⋅ K) or Btu/(hr ⋅ ft 2 ⋅ ∘ F) \text{Btu/(hr}\cdot\text{ft}^2\cdot^\circ\text{F)} Btu/(hr ⋅ ft 2 ⋅ ∘ F) ).

A A A = total outer heat transfer surface area ( m 2 \text{m}^2 m 2 or ft 2 \text{ft}^2 ft 2 ).

Δ T l m \Delta T_{lm} Δ T l m ​ = Log Mean Temperature Difference for pure countercurrent flow.

F F F = empirical LMTD configuration correction factor ( F ≤ 1.00 F \le 1.00 F ≤ 1.00 ). For pure countercurrent flow, F = 1.00 F = 1.00 F = 1.00 .

Derivation of LMTD for Pure Countercurrent Flow

Consider a differential heat transfer element d A dA d A in a counterflow heat exchanger. Across this element, the local temperature difference is Δ T = T h − T c \Delta T = T_h - T_c Δ T = T h ​ − T c ​ . The differential heat transfer is: d Q = U ( T h − T c ) d A = U Δ T d A dQ = U (T_h - T_c) dA = U \Delta T dA d Q = U ( T h ​ − T c ​ ) d A = U Δ T d A

From differential energy balances: d T h = − d Q m ˙ h C p , h = − d Q C h , d T c = − d Q m ˙ c C p , c = − d Q C c dT_h = -\frac{dQ}{\dot{m}_h C_{p,h}} = -\frac{dQ}{C_h}, \quad dT_c = -\frac{dQ}{\dot{m}_c C_{p,c}} = -\frac{dQ}{C_c} d T h ​ = − m ˙ h ​ C p , h ​ d Q ​ = − C h ​ d Q ​ , d T c ​ = − m ˙ c ​ C p , c ​ d Q ​ = − C c ​ d Q ​

Subtracting the two equations yields: d ( Δ T ) = d T h − d T c = − d Q ( 1 C h − 1 C c ) = − U Δ T d A ( 1 C h − 1 C c ) d(\Delta T) = dT_h - dT_c = -dQ \left( \frac{1}{C_h} - \frac{1}{C_c} \right) = -U \Delta T dA \left( \frac{1}{C_h} - \frac{1}{C_c} \right) d ( Δ T ) = d T h ​ − d T c ​ = − d Q ( C h ​ 1 ​ − C c ​ 1 ​ ) = − U Δ T d A ( C h ​ 1 ​ − C c ​ 1 ​ )

Separating variables and integrating from the hot inlet end (End 1) to the hot outlet end (End 2): ∫ Δ T 1 Δ T 2 d ( Δ T ) Δ T = − U ( 1 C h − 1 C c ) ∫ 0 A d A \int_{\Delta T_1}^{\Delta T_2} \frac{d(\Delta T)}{\Delta T} = -U \left( \frac{1}{C_h} - \frac{1}{C_c} \right) \int_0^A dA ∫ Δ T 1 ​ Δ T 2 ​ ​ Δ T d ( Δ T ) ​ = − U ( C h ​ 1 ​ − C c ​ 1 ​ ) ∫ 0 A ​ d A ln ⁡ ( Δ T 2 Δ T 1 ) = − U A ( 1 C h − 1 C c ) \ln\left( \frac{\Delta T_2}{\Delta T_1} \right) = -U A \left( \frac{1}{C_h} - \frac{1}{C_c} \right) ln ( Δ T 1 ​ Δ T 2 ​ ​ ) = − U A ( C h ​ 1 ​ − C c ​ 1 ​ )

Multiplying by total heat transfer Q Q Q and recognizing that Q / C h = T h , i n − T h , o u t Q/C_h = T_{h,in} - T_{h,out} Q / C h ​ = T h , in ​ − T h , o u t ​ and Q / C c = T c , o u t − T c , i n Q/C_c = T_{c,out} - T_{c,in} Q / C c ​ = T c , o u t ​ − T c , in ​ : Q ( 1 C h − 1 C c ) = ( T h , i n − T h , o u t ) − ( T c , o u t − T c , i n ) = ( T h , i n − T c , o u t ) − ( T h , o u t − T c , i n ) = Δ T 1 − Δ T 2 Q \left( \frac{1}{C_h} - \frac{1}{C_c} \right) = (T_{h,in} - T_{h,out}) - (T_{c,out} - T_{c,in}) = (T_{h,in} - T_{c,out}) - (T_{h,out} - T_{c,in}) = \Delta T_1 - \Delta T_2 Q ( C h ​ 1 ​ − C c ​ 1 ​ ) = ( T h , in ​ − T h , o u t ​ ) − ( T c , o u t ​ − T c , in ​ ) = ( T h , in ​ − T c , o u t ​ ) − ( T h , o u t ​ − T c , in ​ ) = Δ T 1 ​ − Δ T 2 ​

Substituting this back gives the universal definition of LMTD : Δ T l m = Δ T 1 − Δ T 2 ln ⁡ ( Δ T 1 Δ T 2 ) \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln\left(\frac{\Delta T_1}{\Delta T_2}\right)} Δ T l m ​ = ln ( Δ T 2 ​ Δ T 1 ​ ​ ) Δ T 1 ​ − Δ T 2 ​ ​

Terminal Temperature Difference Definitions

For Countercurrent Flow (streams flow in opposite directions):

Δ T 1 = T h , i n − T c , o u t \Delta T_1 = T_{h,in} - T_{c,out} Δ T 1 ​ = T h , in ​ − T c , o u t ​ (temperature difference at hot fluid entrance)

Δ T 2 = T h , o u t − T c , i n \Delta T_2 = T_{h,out} - T_{c,in} Δ T 2 ​ = T h , o u t ​ − T c , in ​ (temperature difference at hot fluid exit)

For Cocurrent / Parallel Flow (streams flow in identical directions):

Δ T 1 = T h , i n − T c , i n \Delta T_1 = T_{h,in} - T_{c,in} Δ T 1 ​ = T h , in ​ − T c , in ​ (temperature difference at fluid entrance)

Δ T 2 = T h , o u t − T c , o u t \Delta T_2 = T_{h,out} - T_{c,out} Δ T 2 ​ = T h , o u t ​ − T c , o u t ​ (temperature difference at fluid exit)

Important

Thermodynamic Superiority of Counterflow:

For identical stream temperatures, Δ T l m , counter > Δ T l m , parallel \Delta T_{lm,\text{counter}} > \Delta T_{lm,\text{parallel}} Δ T l m , counter ​ > Δ T l m , parallel ​ . Consequently, countercurrent flow requires significantly less surface area ( A A A ) for the same thermal duty. Furthermore, parallel flow cannot cool the hot fluid below the cold fluid's outlet temperature ( T h , o u t > T c , o u t T_{h,out} > T_{c,out} T h , o u t ​ > T c , o u t ​ always), whereas countercurrent flow allows a temperature cross where T h , o u t < T c , o u t T_{h,out} < T_{c,out} T h , o u t ​ < T c , o u t ​ .

Arithmetic Mean Approximation

When terminal temperature differences are nearly equal ( Δ T 1 ≈ Δ T 2 \Delta T_1 \approx \Delta T_2 Δ T 1 ​ ≈ Δ T 2 ​ ), ln ⁡ ( Δ T 1 / Δ T 2 ) → 0 \ln(\Delta T_1 / \Delta T_2) \to 0 ln ( Δ T 1 ​ /Δ T 2 ​ ) → 0 , creating a 0 / 0 0/0 0/0 indeterminacy. In this limit, Δ T l m \Delta T_{lm} Δ T l m ​ equals the simple arithmetic mean: Δ T a m = Δ T 1 + Δ T 2 2 \Delta T_{am} = \frac{\Delta T_1 + \Delta T_2}{2} Δ T am ​ = 2 Δ T 1 ​ + Δ T 2 ​ ​

If the ratio Δ T 1 / Δ T 2 ≤ 1.50 \Delta T_1 / \Delta T_2 \le 1.50 Δ T 1 ​ /Δ T 2 ​ ≤ 1.50 , the arithmetic mean overestimates the true logarithmic driving force by less than 1.0 % 1.0\% 1.0% , which is well within standard industrial engineering tolerances.

2. TEMA Standards and Three-Letter Nomenclature

The Tubular Exchanger Manufacturers Association (TEMA) standardizes shell-and-tube mechanical configurations using a systematic three-letter designation :

  • [Front Stationary Head] [Shell Type] [Rear Head] +-------------------+
  • Front Head --> | Shell Type (E) | <-- Rear Head
  • (Type A,B,C,D) | (E, F, G, H, J, K, X)| (L, M, N, P, S, T, U, W)
  • +-------------------+
  • 1. Front Heads (Stationary Heads)

Type A (Channel and Removable Cover) : Features a bolted cover plate allowing direct access to tube interiors for inspection and mechanical cleaning without dismantling external piping connections. Best for fouling tube-side fluids.

Type B (Bonnet Integral Cover) : Welded dome cap without a removable cover plate. More economical than Type A and minimizes gasketed joints, but external process piping must be broken to access the tube bundle. Common for clean fluids.

Type C (Channel Integral with Tubesheet) : Tubesheet is welded directly to the channel with a removable cover. Used for hazardous or high-pressure fluids to eliminate a gasketed joint.

Type D (Special High-Pressure Closure) : Heavy-duty closure designed for operating pressures exceeding 150 bar 150\text{ bar} 150 bar ( 2 , 200 psi 2,200\text{ psi} 2 , 200 psi ), such as high-pressure hydroprocessing units.

2. Shell Types

Type E (One-Pass Shell) : The most prevalent industrial shell. Fluid enters at one end and exits at the other. Cost-effective, simple, and capable of high thermal performance when paired with multi-pass tube bundles.

Type F (Two-Pass Shell with Longitudinal Baffle) : Incorporates an internal longitudinal baffle dividing the shell into two flow passes. Enhances LMTD correction factor ( F F F ), but leakage across the longitudinal baffle can significantly degrade performance if not properly sealed.

Type G (Split Flow) and Type H (Double Split Flow) : Longitudinal baffles with central inlets and split outlets. Used to reduce shell-side pressure drop while preventing tube vibration in thermosiphon reboilers.

Type J (Divided Flow) : One central nozzle splits flow toward both ends (or two inlets combine at a central outlet). Cuts shell-side pressure drop to approximately 1 / 8 1/8 1/8 th of an equivalent E-shell; ideal for vacuum condensers.

Type K (Kettle Reboiler) : Enlarged vapor disengagement dome above a submerged tube bundle. Standard for distillation column reboilers and refrigeration evaporators.

Type X (Crossflow Shell) : Fluid flows purely perpendicular to the tube bundle across the entire length with no segmental baffles. Provides the lowest possible shell-side pressure drop; standard for power plant steam surface condensers.

3. Rear Heads

Fixed Tubesheet (Types L, M, N) : Both tubesheets are welded directly to the shell. Lowest cost and eliminates internal gasketed leakage points. However, the shell interior cannot be mechanically cleaned, and large temperature differences between tube and shell ( > 50 ∘ C > 50^\circ\text{C} > 5 0 ∘ C ) induce severe thermal expansion stresses requiring shell expansion bellows.

Floating Head (Types S, T, P, W) : One tubesheet floats freely inside the shell, eliminating all thermal expansion differential stresses and allowing the tube bundle to be pulled for mechanical hydroblasting.

Type S (Floating Head with Backing Device) : Shell cover diameter must be larger than shell; backing ring clamps floating head. Industry standard for heavy refinery duty.

Type T (Pull-Through Floating Head) : The entire floating head can be pulled directly through the shell without removing the floating head cover. Simplifies maintenance but leaves a large peripheral annular gap that promotes bundle bypass.

U-Tube Bundle (Type U) : Tubes are bent into continuous U-shapes attached to a single stationary tubesheet. Completely accommodates differential thermal expansion at low cost. However, the internal radius of the U-bends cannot be mechanically cleaned with drill rods or hydroblasting lances; tube-side fluids must be clean.

TEMA Mechanical Classes

TEMA R : Severe petroleum refinery and petrochemical processing (heavy wall thicknesses, corrosion allowances, safety-critical).

TEMA C : General commercial chemical and utility service (moderate severity, cost-optimized).

TEMA B : Chemical process service where safety and corrosion resistance are prioritized under ASME Section VIII rules.

  • 3. Tube Layout, Pitch, Baffles, and Bundle Geometry
  • Tube Pitch Configurations

The arrangement of tubes within the tubesheet is characterized by the tube pitch ( P t P_t P t ​ ), which is the center-to-center distance between adjacent tubes. Standard tube outer diameters ( d o d_o d o ​ ) are 3 / 4 in 3/4\text{ in} 3/4 in ( 19.05 mm 19.05\text{ mm} 19.05 mm ) and 1.00 in 1.00\text{ in} 1.00 in ( 25.4 mm 25.4\text{ mm} 25.4 mm ).

Layout Angle Pattern Name Flow Characteristics Cleanability Relative Heat Transfer ( j H j_H j H ​ ) & Pressure Drop ( Δ P \Delta P Δ P )

30 ∘ 30^\circ 3 0 ∘ Triangular Highest packing density; intense turbulence Chemical cleaning only (no continuous lanes) Highest h o h_o h o ​ , highest Δ P s \Delta P_s Δ P s ​ per unit length

60 ∘ 60^\circ 6 0 ∘ Rotated Triangular Similar to 30 ∘ 30^\circ 3 0 ∘ ; allows drainage Chemical cleaning only High h o h_o h o ​ , high Δ P s \Delta P_s Δ P s ​

90 ∘ 90^\circ 9 0 ∘ In-Line Square Open lanes between rows Mechanical cleaning (hydroblast lance lane ≥ 6.35 mm \ge 6.35\text{ mm} ≥ 6.35 mm ) Lowest Δ P s \Delta P_s Δ P s ​ , lower h o h_o h o ​ (stagnant eddies behind tubes)

45 ∘ 45^\circ 4 5 ∘ Rotated Square Open diagonal lanes; higher impingement Mechanical cleaning accessible along diagonal Higher h o h_o h o ​ than 90 ∘ 90^\circ 9 0 ∘ at laminar/transitional Reynolds numbers

Standard pitch ratio is P t / d o = 1.25 P_t / d_o = 1.25 P t ​ / d o ​ = 1.25 . For square pitch, the minimum continuous cleaning lane is: C = P t − d o ≥ 0.25 in ( 6.35 mm ) C = P_t - d_o \ge 0.25\text{ in} \quad (6.35\text{ mm}) C = P t ​ − d o ​ ≥ 0.25 in ( 6.35 mm )

Triangular pitch holds approximately 15 % 15\% 15% more tubes in an identical shell diameter compared to square pitch, yielding a significantly more compact exchanger when shell-side fluids do not form hard mechanical fouling deposits.

Transverse Segmental Baffles

Baffles serve two vital engineering functions:

Structurally support the tubes against flow-induced vibration and sagging.

Force the shell-side fluid to flow across the tube bundle in perpendicular crossflow, vastly increasing convective turbulence.

Baffle Cut : The height of the segmental opening expressed as a percentage of the inside shell diameter ( D s D_s D s ​ ). The optimal industrial range is 20 % 20\% 20% to 25 % 25\% 25% . If the cut is too small ( < 15 % <15\% < 15% ), fluid velocity spikes through the window, inducing extreme pressure drops and stagnant recirculation pockets behind the baffles. If the cut is too large ( > 35 % >35\% > 35% ), fluid bypasses the crossflow zone, causing severe thermal stratification.

Baffle Spacing ( B B B ) : Center-to-center distance between adjacent baffles. Standard TEMA limits dictate: 0.2 ⋅ D s ≤ B ≤ 1.0 ⋅ D s 0.2 \cdot D_s \le B \le 1.0 \cdot D_s 0.2 ⋅ D s ​ ≤ B ≤ 1.0 ⋅ D s ​

  • 4. Shell-Side Hydraulics & Rating: Kern's Method vs. Bell-Delaware Method
  • Kern's Method (Simplified Design Method)

Kern's method is the classical analytical framework used on the PE Chemical exam for preliminary shell-side sizing. It assumes idealized crossflow across the tube bundle:

Bundle Crossflow Area ( S m S_m S m ​ ) at the shell centerline: S m = B ⋅ D s ( P t − d o ) P t S_m = \frac{B \cdot D_s (P_t - d_o)}{P_t} S m ​ = P t ​ B ⋅ D s ​ ( P t ​ − d o ​ ) ​

Shell-Side Mass Velocity ( G s G_s G s ​ ) : G s = m ˙ s S m G_s = \frac{\dot{m}_s}{S_m} G s ​ = S m ​ m ˙ s ​ ​

Equivalent Hydraulic Diameter ( D e D_e D e ​ ) :

For 30 ∘ 30^\circ 3 0 ∘ Triangular Pitch: D e = 4 ( 3 4 P t 2 − π 8 d o 2 ) π 2 d o = 1.103 P t 2 − 0.785 d o 2 d o D_e = \frac{4 \left( \frac{\sqrt{3}}{4} P_t^2 - \frac{\pi}{8} d_o^2 \right)}{\frac{\pi}{2} d_o} = \frac{1.103 P_t^2 - 0.785 d_o^2}{d_o} D e ​ = 2 π ​ d o ​ 4 ( 4 3 ​ ​ P t 2 ​ − 8 π ​ d o 2 ​ ) ​ = d o ​ 1.103 P t 2 ​ − 0.785 d o 2 ​ ​

For 90 ∘ 90^\circ 9 0 ∘ Square Pitch: D e = 4 ( P t 2 − π 4 d o 2 ) π d o = 1.273 P t 2 − d o 2 d o D_e = \frac{4 \left( P_t^2 - \frac{\pi}{4} d_o^2 \right)}{\pi d_o} = \frac{1.273 P_t^2 - d_o^2}{d_o} D e ​ = π d o ​ 4 ( P t 2 ​ − 4 π ​ d o 2 ​ ) ​ = d o ​ 1.273 P t 2 ​ − d o 2 ​ ​

Shell Reynolds Number & Nusselt Correlation : R e s = D e G s μ s Re_s = \frac{D_e G_s}{\mu_s} R e s ​ = μ s ​ D e ​ G s ​ ​ N u s = h o D e k s = 0.36 ( R e s ) 0.55 ( P r s ) 1 / 3 ( μ s μ s , w ) 0.14 Nu_s = \frac{h_o D_e}{k_s} = 0.36 \left( Re_s \right)^{0.55} \left( Pr_s \right)^{1/3} \left( \frac{\mu_s}{\mu_{s,w}} \right)^{0.14} N u s ​ = k s ​ h o ​ D e ​ ​ = 0.36 ( R e s ​ ) 0.55 ( P r s ​ ) 1/3 ( μ s , w ​ μ s ​ ​ ) 0.14

Bell-Delaware Method (Rigorous Industrial Rating)

Kern's method overpredicts shell-side heat transfer by 20 − 40 % 20-40\% 20 − 40% and pressure drop by up to 100 % 100\% 100% because it ignores leakage and bypass streams. The Bell-Delaware method introduces empirical correction factors ( J J J ) to adjust ideal tube bank crossflow ( h i d e a l h_{ideal} h i d e a l ​ ): h o = h i d e a l ⋅ J c ⋅ J l ⋅ J b ⋅ J s ⋅ J r h_o = h_{ideal} \cdot J_c \cdot J_l \cdot J_b \cdot J_s \cdot J_r h o ​ = h i d e a l ​ ⋅ J c ​ ⋅ J l ​ ⋅ J b ​ ⋅ J s ​ ⋅ J r ​

Where:

J c J_c J c ​ = Segmental baffle cut correction factor (accounts for heat transfer in window vs. crossflow).

J l J_l J l ​ = Baffle leakage correction factor (accounts for tube-to-baffle hole and baffle-to-shell annular clearances; reduces h o h_o h o ​ by 15 − 30 % 15-30\% 15 − 30% ).

J b J_b J b ​ = Bundle-to-shell bypass correction factor (accounts for flow bypassing around the bundle perimeter; restored using sealing strips).

J s J_s J s ​ = Unequal baffle spacing correction factor at inlet and exit nozzles.

J r J_r J r ​ = Adverse temperature gradient correction factor for laminar flow ( R e s < 100 Re_s < 100 R e s ​ < 100 ).

5. LMTD Correction Factor ( F F F ) and Temperature Cross

In multi-pass exchangers (e.g., a 1-2 exchanger with 1 shell pass and 2 tube passes), fluid in one tube pass travels cocurrently with the shell fluid while fluid in the other pass travels countercurrently. Consequently, the true effective temperature driving force is less than pure counterflow LMTD: Δ T e f f = F ⋅ Δ T l m \Delta T_{eff} = F \cdot \Delta T_{lm} Δ T e ff ​ = F ⋅ Δ T l m ​

The correction factor F F F ( 0 < F ≤ 1.0 0 < F \le 1.0 0 < F ≤ 1.0 ) is parameterized by two dimensionless thermal ratios:

1. Thermal Effectiveness ( P P P )

Ratio of the cold fluid temperature rise to the maximum theoretical temperature difference: P = t 2 − t 1 T 1 − t 1 ( 0 ≤ P ≤ 1 ) P = \frac{t_2 - t_1}{T_1 - t_1} \quad (0 \le P \le 1) P = T 1 ​ − t 1 ​ t 2 ​ − t 1 ​ ​ ( 0 ≤ P ≤ 1 )

(Note: Here uppercase T T T designates shell-side temperatures, and lowercase t t t designates tube-side temperatures; subscript 1 is inlet, 2 is outlet).

2. Heat Capacity Rate Ratio ( R R R )

Ratio of the tube-side heat capacity rate to the shell-side heat capacity rate: R = T 1 − T 2 t 2 − t 1 = ( m ˙ C p ) t u b e ( m ˙ C p ) s h e l l R = \frac{T_1 - T_2}{t_2 - t_1} = \frac{(\dot{m} C_p)_{tube}}{(\dot{m} C_p)_{shell}} R = t 2 ​ − t 1 ​ T 1 ​ − T 2 ​ ​ = ( m ˙ C p ​ ) s h e ll ​ ( m ˙ C p ​ ) t u b e ​ ​

Analytical Closed-Form Expression for a 1-2 Exchanger

For one shell pass and any even number of tube passes ( 2 , 4 , 6 , … 2, 4, 6, \dots 2 , 4 , 6 , … ): F = R 2 + 1 ln ⁡ ( 1 − P 1 − P R ) ( R − 1 ) ln ⁡ [ 2 − P ( R + 1 − R 2 + 1 ) 2 − P ( R + 1 + R 2 + 1 ) ] F = \frac{\sqrt{R^2 + 1} \ln\left( \frac{1 - P}{1 - P R} \right)}{(R - 1) \ln\left[ \frac{2 - P \left( R + 1 - \sqrt{R^2 + 1} \right)}{2 - P \left( R + 1 + \sqrt{R^2 + 1} \right)} \right]} F = ( R − 1 ) ln [ 2 − P ( R + 1 + R 2 + 1 ​ ) 2 − P ( R + 1 − R 2 + 1 ​ ) ​ ] R 2 + 1 ​ ln ( 1 − PR 1 − P ​ ) ​

(When R = 1.0 R = 1.0 R = 1.0 , evaluate the indeterminate form using L'Hôpital's rule or algebraic series expansion). F ^

  • 1.0 |-------------------\
  • | \
  • 0.8 |=====================\ <--- Critical Design Threshold (F >= 0.80)
  • | \
  • 0.6 | \
  • | |
  • +------------------------+---> P (Thermal Effectiveness)
  • P_max (Asymptote where F plummets)
  • The F ≥ 0.80 F \ge 0.80 F ≥ 0.80 Design Rule

On the NCEES PE Chemical exam, remember that a design where F < 0.75 to 0.80 F < 0.75\text{ to }0.80 F < 0.75 to 0.80 is unacceptable . When F F F drops below 0.80 0.80 0.80 , the slope ∣ d F / d P ∣ |dF/dP| ∣ d F / d P ∣ becomes extremely steep. A minor change in operating flow rate, cooling water temperature, or fouling factor causes F F F to plunge toward zero, collapsing heat duty. Furthermore, F < 0.80 F < 0.80 F < 0.80 requires excessive surface area, rendering the exchanger economically unviable.

The Temperature Cross Limitation

A temperature cross occurs when the cold fluid exit temperature exceeds the hot fluid exit temperature ( t 2 > T 2 t_2 > T_2 t 2 ​ > T 2 ​ ). In a 1-2 exchanger, a severe temperature cross causes the denominator argument of the F F F formula to become negative: 2 − P ( R + 1 + R 2 + 1 ) ≤ 0 2 - P \left( R + 1 + \sqrt{R^2 + 1} \right) \le 0 2 − P ( R + 1 + R 2 + 1 ​ ) ≤ 0

When this occurs, F F F becomes mathematically undefined and physically impossible in a single shell because heat transfers backwards from the heated tube fluid back into the cooling shell fluid!

Tip

Resolving Temperature Cross:

To achieve a temperature cross while maintaining F ≥ 0.80 F \ge 0.80 F ≥ 0.80 , the chemical engineer must:

Use multiple shells in series ( N N N shells in series). Each individual shell handles a fraction of the thermal rise, reducing the per-shell effectiveness P 1 P_1 P 1 ​ below the threshold.

Use a TEMA F two-pass shell (equivalent to two shells in series).

Use true countercurrent double-pipe or plate-and-frame exchangers where F ≡ 1.00 F \equiv 1.00 F ≡ 1.00 .

6. Summary Comparison Table: TEMA Configurations and Layouts

Feature / Parameter Triangular Pitch ( 30 ∘ / 60 ∘ 30^\circ / 60^\circ 3 0 ∘ /6 0 ∘ ) Square Pitch ( 90 ∘ / 45 ∘ 90^\circ / 45^\circ 9 0 ∘ /4 5 ∘ ) TEMA E-Shell TEMA F-Shell Fixed Tubesheet (L, M, N) Floating Head (S, T)

Primary Advantage Maximum surface density ( + 15 % +15\% + 15% tubes); high h o h_o h o ​ Continuous cleaning lanes; low Δ P s \Delta P_s Δ P s ​ Low cost; standard design; highly versatile Higher LMTD correction ( F F F ); handles temp cross Lowest cost; no internal gaskets; no leakage Accommodates extreme Δ T \Delta T Δ T ; bundle pullable

Primary Disadvantage Cannot clean mechanically; chemical cleaning only Lower heat transfer coefficient; larger shell Limited in temperature cross service Risk of internal bypass across baffle weld Tubesheet welded to shell; shell cannot be cleaned Highest initial capital cost; complex mechanical seals

Fouling Suitability Clean shell-side fluids ( R f , o < 0.0002 m 2 K/W R_{f,o} < 0.0002\text{ m}^2\text{K/W} R f , o ​ < 0.0002 m 2 K/W ) Severe fouling / coking ( R f , o > 0.0004 m 2 K/W R_{f,o} > 0.0004\text{ m}^2\text{K/W} R f , o ​ > 0.0004 m 2 K/W ) Clean to moderate fouling Clean fluids (prevent baffle leakage) Clean shell fluids; tube fluid can be fouling Heavy fouling on both tube and shell sides

Thermal Stress N/A N/A Normal Differential thermal stress across baffle Severe stress if Δ T > 50 ∘ C \Delta T > 50^\circ\text{C} Δ T > 5 0 ∘ C (needs bellows) Zero thermal stress (floats freely)

  • 7. Comprehensive Worked Numerical Example: Crude Heavy Gas Oil (HGO) Cooler Sizing
  • Problem Statement

A petroleum refinery design team must size a TEMA 1-2 AES shell-and-tube heat exchanger to cool 80 , 000 kg/h 80,000\text{ kg/h} 80 , 000 kg/h ( 22.222 kg/s 22.222\text{ kg/s} 22.222 kg/s ) of heavy gas oil (HGO) from 180.0 ∘ C 180.0^\circ\text{C} 180. 0 ∘ C to 90.0 ∘ C 90.0^\circ\text{C} 90. 0 ∘ C on the shell side.

Treated cooling water is available on the tube side entering at t 1 = 30.0 ∘ C t_1 = 30.0^\circ\text{C} t 1 ​ = 30. 0 ∘ C with a maximum permissible exit temperature of t 2 = 65.0 ∘ C t_2 = 65.0^\circ\text{C} t 2 ​ = 65. 0 ∘ C .

Physical Properties:

HGO (Shell side): C p , h = 2.40 kJ/(kg ⋅ K) C_{p,h} = 2.40\text{ kJ/(kg}\cdot\text{K)} C p , h ​ = 2.40 kJ/(kg ⋅ K) , ρ h = 820 kg/m 3 \rho_h = 820\text{ kg/m}^3 ρ h ​ = 820 kg/m 3

Cooling Water (Tube side): C p , c = 4.184 kJ/(kg ⋅ K) C_{p,c} = 4.184\text{ kJ/(kg}\cdot\text{K)} C p , c ​ = 4.184 kJ/(kg ⋅ K) , ρ c = 992 kg/m 3 \rho_c = 992\text{ kg/m}^3 ρ c ​ = 992 kg/m 3

Design overall fouled heat transfer coefficient: U = 450.0 W/(m 2 ⋅ K) U = 450.0\text{ W/(m}^2\cdot\text{K)} U = 450.0 W/(m 2 ⋅ K)

Carbon steel tubes: 3 / 4 in 3/4\text{ in} 3/4 in OD ( d o = 19.05 mm = 0.01905 m d_o = 19.05\text{ mm} = 0.01905\text{ m} d o ​ = 19.05 mm = 0.01905 m ), tube length L = 6.00 m L = 6.00\text{ m} L = 6.00 m , 2 tube passes.

Calculate:

The total heat duty ( Q Q Q ) in kW \text{kW} kW .

The required cooling water mass flow rate ( m ˙ c \dot{m}_c m ˙ c ​ ) in kg/s \text{kg/s} kg/s and kg/h \text{kg/h} kg/h .

The pure counterflow Log Mean Temperature Difference ( Δ T l m \Delta T_{lm} Δ T l m ​ ).

The dimensionless thermal ratios R R R and P P P , and the LMTD correction factor F F F .

The effective temperature difference ( Δ T e f f = F ⋅ Δ T l m \Delta T_{eff} = F \cdot \Delta T_{lm} Δ T e ff ​ = F ⋅ Δ T l m ​ ).

The required outside heat transfer surface area ( A A A ) in m 2 \text{m}^2 m 2 .

The total number of tubes ( N t N_t N t ​ ) and tubes per pass.

Step 1: Heat Duty Calculation Q = m ˙ h C p , h ( T h , i n − T h , o u t ) Q = \dot{m}_h C_{p,h} (T_{h,in} - T_{h,out}) Q = m ˙ h ​ C p , h ​ ( T h , in ​ − T h , o u t ​ ) Q = ( 22.222 kg/s ) × ( 2.40 kJ/(kg ⋅ K) ) × ( 180.0 ∘ C − 90.0 ∘ C ) Q = (22.222\text{ kg/s}) \times (2.40\text{ kJ/(kg}\cdot\text{K)}) \times (180.0^\circ\text{C} - 90.0^\circ\text{C}) Q = ( 22.222 kg/s ) × ( 2.40 kJ/(kg ⋅ K) ) × ( 180. 0 ∘ C − 90. 0 ∘ C ) Q = 22.222 × 2.40 × 90.0 = 4 , 800.0 kW = 4.800 × 10 6 W Q = 22.222 \times 2.40 \times 90.0 = \mathbf{4,800.0\text{ kW}} = \mathbf{4.800 \times 10^6\text{ W}} Q = 22.222 × 2.40 × 90.0 = 4 , 800.0 kW = 4.800 × 1 0 6 W

Step 2: Cooling Water Mass Flow Rate Q = m ˙ c C p , c ( t 2 − t 1 ) Q = \dot{m}_c C_{p,c} (t_2 - t_1) Q = m ˙ c ​ C p , c ​ ( t 2 ​ − t 1 ​ ) m ˙ c = Q C p , c ( t 2 − t 1 ) = 4 , 800.0 kW ( 4.184 kJ/(kg ⋅ K) ) × ( 65.0 ∘ C − 30.0 ∘ C ) \dot{m}_c = \frac{Q}{C_{p,c} (t_2 - t_1)} = \frac{4,800.0\text{ kW}}{(4.184\text{ kJ/(kg}\cdot\text{K)}) \times (65.0^\circ\text{C} - 30.0^\circ\text{C})} m ˙ c ​ = C p , c ​ ( t 2 ​ − t 1 ​ ) Q ​ = ( 4.184 kJ/(kg ⋅ K) ) × ( 65. 0 ∘ C − 30. 0 ∘ C ) 4 , 800.0 kW ​ m ˙ c = 4 , 800.0 4.184 × 35.0 = 4 , 800.0 146.44 = 32.778 kg/s \dot{m}_c = \frac{4,800.0}{4.184 \times 35.0} = \frac{4,800.0}{146.44} = \mathbf{32.778\text{ kg/s}} m ˙ c ​ = 4.184 × 35.0 4 , 800.0 ​ = 146.44 4 , 800.0 ​ = 32.778 kg/s

Converting to hourly flow: m ˙ c = 32.778 kg/s × 3 , 600 s/h = 118 , 000 kg/h \dot{m}_c = 32.778\text{ kg/s} \times 3,600\text{ s/h} = \mathbf{118,000\text{ kg/h}} m ˙ c ​ = 32.778 kg/s × 3 , 600 s/h = 118 , 000 kg/h

Step 3: Pure Counterflow LMTD Determination

Terminal temperature differences:

Δ T 1 = T h , i n − t 2 = 180.0 ∘ C − 65.0 ∘ C = 115.0 ∘ C \Delta T_1 = T_{h,in} - t_2 = 180.0^\circ\text{C} - 65.0^\circ\text{C} = \mathbf{115.0^\circ\text{C}} Δ T 1 ​ = T h , in ​ − t 2 ​ = 180. 0 ∘ C − 65. 0 ∘ C = 115. 0 ∘ C

Δ T 2 = T h , o u t − t 1 = 90.0 ∘ C − 30.0 ∘ C = 60.0 ∘ C \Delta T_2 = T_{h,out} - t_1 = 90.0^\circ\text{C} - 30.0^\circ\text{C} = \mathbf{60.0^\circ\text{C}} Δ T 2 ​ = T h , o u t ​ − t 1 ​ = 90. 0 ∘ C − 30. 0 ∘ C = 60. 0 ∘ C

Ratio: Δ T 1 Δ T 2 = 115.0 60.0 = 1.91667 \frac{\Delta T_1}{\Delta T_2} = \frac{115.0}{60.0} = 1.91667 Δ T 2 ​ Δ T 1 ​ ​ = 60.0 115.0 ​ = 1.91667 Δ T l m = Δ T 1 − Δ T 2 ln ⁡ ( Δ T 1 / Δ T 2 ) = 115.0 − 60.0 ln ⁡ ( 1.91667 ) = 55.0 0.65059 = 84.539 ∘ C \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \frac{115.0 - 60.0}{\ln(1.91667)} = \frac{55.0}{0.65059} = \mathbf{84.539^\circ\text{C}} Δ T l m ​ = ln ( Δ T 1 ​ /Δ T 2 ​ ) Δ T 1 ​ − Δ T 2 ​ ​ = ln ( 1.91667 ) 115.0 − 60.0 ​ = 0.65059 55.0 ​ = 84.53 9 ∘ C

Step 4: Dimensionless Ratios and LMTD Correction Factor ( F F F )

Heat capacity rate ratio ( R R R ): R = T 1 − T 2 t 2 − t 1 = 180.0 − 90.0 65.0 − 30.0 = 90.0 35.0 = 2.57143 R = \frac{T_1 - T_2}{t_2 - t_1} = \frac{180.0 - 90.0}{65.0 - 30.0} = \frac{90.0}{35.0} = \mathbf{2.57143} R = t 2 ​ − t 1 ​ T 1 ​ − T 2 ​ ​ = 65.0 − 30.0 180.0 − 90.0 ​ = 35.0 90.0 ​ = 2.57143

Thermal effectiveness ( P P P ): P = t 2 − t 1 T 1 − t 1 = 65.0 − 30.0 180.0 − 30.0 = 35.0 150.0 = 0.23333 P = \frac{t_2 - t_1}{T_1 - t_1} = \frac{65.0 - 30.0}{180.0 - 30.0} = \frac{35.0}{150.0} = \mathbf{0.23333} P = T 1 ​ − t 1 ​ t 2 ​ − t 1 ​ ​ = 180.0 − 30.0 65.0 − 30.0 ​ = 150.0 35.0 ​ = 0.23333

Check product P ⋅ R P \cdot R P ⋅ R : P ⋅ R = 0.23333 × 2.57143 = 0.6000 < 1.0 (Thermodynamically feasible) P \cdot R = 0.23333 \times 2.57143 = 0.6000 < 1.0 \quad \text{(Thermodynamically feasible)} P ⋅ R = 0.23333 × 2.57143 = 0.6000 < 1.0 (Thermodynamically feasible)

Evaluate R 2 + 1 \sqrt{R^2 + 1} R 2 + 1 ​ : R 2 + 1 = ( 2.57143 ) 2 + 1 = 6.61224 + 1 = 7.61224 = 2.75903 \sqrt{R^2 + 1} = \sqrt{(2.57143)^2 + 1} = \sqrt{6.61224 + 1} = \sqrt{7.61224} = \mathbf{2.75903} R 2 + 1 ​ = ( 2.57143 ) 2 + 1 ​ = 6.61224 + 1 ​ = 7.61224 ​ = 2.75903

Numerator of F F F expression: Num = R 2 + 1 ln ⁡ ( 1 − P 1 − P R ) = 2.75903 ln ⁡ ( 1 − 0.23333 1 − 0.60000 ) = 2.75903 ln ⁡ ( 0.76667 0.40000 ) \text{Num} = \sqrt{R^2 + 1} \ln\left( \frac{1 - P}{1 - P R} \right) = 2.75903 \ln\left( \frac{1 - 0.23333}{1 - 0.60000} \right) = 2.75903 \ln\left( \frac{0.76667}{0.40000} \right) Num = R 2 + 1 ​ ln ( 1 − PR 1 − P ​ ) = 2.75903 ln ( 1 − 0.60000 1 − 0.23333 ​ ) = 2.75903 ln ( 0.40000 0.76667 ​ ) Num = 2.75903 ln ⁡ ( 1.91667 ) = 2.75903 × 0.65059 = 1.79499 \text{Num} = 2.75903 \ln(1.91667) = 2.75903 \times 0.65059 = \mathbf{1.79499} Num = 2.75903 ln ( 1.91667 ) = 2.75903 × 0.65059 = 1.79499

Denominator terms:

Term 1: R + 1 − R 2 + 1 = 2.57143 + 1 − 2.75903 = 0.81240 R + 1 - \sqrt{R^2 + 1} = 2.57143 + 1 - 2.75903 = 0.81240 R + 1 − R 2 + 1 ​ = 2.57143 + 1 − 2.75903 = 0.81240 2 − P ( 0.81240 ) = 2 − ( 0.23333 × 0.81240 ) = 2 − 0.18956 = 1.81044 2 - P(0.81240) = 2 - (0.23333 \times 0.81240) = 2 - 0.18956 = \mathbf{1.81044} 2 − P ( 0.81240 ) = 2 − ( 0.23333 × 0.81240 ) = 2 − 0.18956 = 1.81044

Term 2: R + 1 + R 2 + 1 = 2.57143 + 1 + 2.75903 = 6.33046 R + 1 + \sqrt{R^2 + 1} = 2.57143 + 1 + 2.75903 = 6.33046 R + 1 + R 2 + 1 ​ = 2.57143 + 1 + 2.75903 = 6.33046 2 − P ( 6.33046 ) = 2 − ( 0.23333 × 6.33046 ) = 2 − 1.47711 = 0.52289 2 - P(6.33046) = 2 - (0.23333 \times 6.33046) = 2 - 1.47711 = \mathbf{0.52289} 2 − P ( 6.33046 ) = 2 − ( 0.23333 × 6.33046 ) = 2 − 1.47711 = 0.52289

Argument of logarithm in denominator: 1.81044 0.52289 = 3.46237 \frac{1.81044}{0.52289} = 3.46237 0.52289 1.81044 ​ = 3.46237 ln ⁡ ( 3.46237 ) = 1.24191 \ln(3.46237) = 1.24191 ln ( 3.46237 ) = 1.24191

Denominator: Den = ( R − 1 ) ln ⁡ ( 3.46237 ) = ( 2.57143 − 1 ) × 1.24191 = 1.57143 × 1.24191 = 1.95157 \text{Den} = (R - 1) \ln(3.46237) = (2.57143 - 1) \times 1.24191 = 1.57143 \times 1.24191 = \mathbf{1.95157} Den = ( R − 1 ) ln ( 3.46237 ) = ( 2.57143 − 1 ) × 1.24191 = 1.57143 × 1.24191 = 1.95157

Correction factor F F F : F = Num Den = 1.79499 1.95157 = 0.91977 ≈ 0.920 F = \frac{\text{Num}}{\text{Den}} = \frac{1.79499}{1.95157} = \mathbf{0.91977} \approx \mathbf{0.920} F = Den Num ​ = 1.95157 1.79499 ​ = 0.91977 ≈ 0.920

Because F = 0.920 > 0.80 F = 0.920 > 0.80 F = 0.920 > 0.80 , the design is thermally stable and robust against operational fluctuations.

Step 5: Effective Temperature Difference and Required Area Δ T e f f = F ⋅ Δ T l m = 0.91977 × 84.539 ∘ C = 77.756 ∘ C \Delta T_{eff} = F \cdot \Delta T_{lm} = 0.91977 \times 84.539^\circ\text{C} = \mathbf{77.756^\circ\text{C}} Δ T e ff ​ = F ⋅ Δ T l m ​ = 0.91977 × 84.53 9 ∘ C = 77.75 6 ∘ C

Required heat transfer area: A = Q U ⋅ Δ T e f f = 4.800 × 10 6 W ( 450.0 W/(m 2 ⋅ K) ) × ( 77.756 K ) = 4 , 800 , 000 34 , 990.2 = 137.18 m 2 A = \frac{Q}{U \cdot \Delta T_{eff}} = \frac{4.800 \times 10^6\text{ W}}{(450.0\text{ W/(m}^2\cdot\text{K)}) \times (77.756\text{ K})} = \frac{4,800,000}{34,990.2} = \mathbf{137.18\text{ m}^2} A = U ⋅ Δ T e ff ​ Q ​ = ( 450.0 W/(m 2 ⋅ K) ) × ( 77.756 K ) 4.800 × 1 0 6 W ​ = 34 , 990.2 4 , 800 , 000 ​ = 137.18 m 2

Step 6: Tube Count Determination

Outside surface area of a single tube: A single = π ⋅ d o ⋅ L = π × ( 0.01905 m ) × ( 6.00 m ) = 0.35908 m 2 A_{\text{single}} = \pi \cdot d_o \cdot L = \pi \times (0.01905\text{ m}) \times (6.00\text{ m}) = \mathbf{0.35908\text{ m}^2} A single ​ = π ⋅ d o ​ ⋅ L = π × ( 0.01905 m ) × ( 6.00 m ) = 0.35908 m 2

Total number of tubes required: N t = A A single = 137.18 m 2 0.35908 m 2 / tube = 382.04 → 382 tubes N_t = \frac{A}{A_{\text{single}}} = \frac{137.18\text{ m}^2}{0.35908\text{ m}^2/\text{tube}} = 382.04 \to \mathbf{382\text{ tubes}} N t ​ = A single ​ A ​ = 0.35908 m 2 / tube 137.18 m 2 ​ = 382.04 → 382 tubes

For a two-pass bundle ( N p = 2 N_p = 2 N p ​ = 2 ): N pass = 382 2 = 191 tubes per pass N_{\text{pass}} = \frac{382}{2} = \mathbf{191\text{ tubes per pass}} N pass ​ = 2 382 ​ = 191 tubes per pass

  • 8. Critical PE Exam Traps & Pitfalls
  • Trap 1: Designing with an Unstable F < 0.80 F < 0.80 F < 0.80

If your calculated LMTD correction factor F F F is less than 0.80 0.80 0.80 , do not simply accept the area sizing! On the PE exam, this indicates a design flaw. You must recognize that the exchanger is operating too close to its thermal limit, causing extreme sensitivity to fouling. The solution is to switch to two shells in series ( 2 2 2 E-shells) or a TEMA F shell, which restores F F F to > 0.90 > 0.90 > 0.90 .

Trap 2: Ignoring the Shell Expansion Differential

When the temperature difference between shell fluid and tube fluid exceeds 50 ∘ C 50^\circ\text{C} 5 0 ∘ C ( 100 ∘ F 100^\circ\text{F} 10 0 ∘ F ), selecting a fixed tubesheet (TEMA BEM) without an expansion joint is a critical mechanical error. Differential thermal expansion will cause tube buckling or shear tubes from the tubesheet welds. Always specify a floating head (TEMA AES) or U-tube bundle (TEMA AEU) for high Δ T \Delta T Δ T service.

Trap 3: Mixing Terminal Temperature Difference Indices in Counterflow vs. Parallel Flow

In countercurrent flow, Δ T 1 = T h , i n − T c , o u t \Delta T_1 = T_{h,in} - T_{c,out} Δ T 1 ​ = T h , in ​ − T c , o u t ​ and Δ T 2 = T h , o u t − T c , i n \Delta T_2 = T_{h,out} - T_{c,in} Δ T 2 ​ = T h , o u t ​ − T c , in ​ . A common exam blunder is setting Δ T 1 = T h , i n − T c , i n \Delta T_1 = T_{h,in} - T_{c,in} Δ T 1 ​ = T h , in ​ − T c , in ​ , which represents parallel flow. This error drastically underestimates Δ T l m \Delta T_{lm} Δ T l m ​ and grossly oversizes the heat exchanger.