Study guide

1.3 Recycle, Bypass, and Purge Operations

PE Chemical Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the PE Chemical Exam How to Use This Guide and the NCEES Handbook

2 Chapter 1: Material Balances & Flowsheet Calculations

1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations

3 Chapter 2: Energy Balances & Thermochemistry

2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances

4 Chapter 3: Fluid Statics & Incompressible Pipe Flow

3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations

5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow

4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up

6 Chapter 5: Thermodynamic Laws & Fundamental Relations

5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations

7 Chapter 6: Real Gases & Equations of State

6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions

8 Chapter 7: Phase & Chemical Reaction Equilibria

7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation

9 Chapter 8: Heat Transfer Mechanisms & Conduction

8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange

10 Chapter 9: Heat Exchanger Design & Phase Change

9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances

11 Chapter 10: Mass Transfer Fundamentals & Diffusion

10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)

12 Chapter 11: Distillation Operations

11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components

13 Chapter 12: Rate-Controlled & Equilibrium Separations

12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations

14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors

13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations

15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis

14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models

16 Chapter 15: Physical & Transport Properties of Fluids

15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles

17 Chapter 16: Materials of Construction & Corrosion

16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention

18 Chapter 17: Process Safety & Pressure Relief Systems

17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment

19 Chapter 18: Process Control & Engineering Economics

18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems

20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance

19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation

21 Chapter 20: Plant Operation, Reliability & Continuous Improvement

20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting

1.3 Recycle, Bypass, and Purge Operations

Key Takeaways Explain This Topic AI

Single-pass conversion (X_sp) measures performance across the reactor vessel alone, whereas overall conversion (X_ov) measures net performance across the entire plant envelope.

The Cardinal Purge Rule dictates that at steady state, the molar rate of inert entering in the fresh feed must identically equal the molar rate of inert exiting in the purge (F_inert,fresh = F_purge * x_inert,purge).

Purging prevents inert and trace byproduct accumulation in closed recycle loops, but inevitably incurs an economic penalty by co-purging valuable unreacted reactants.

Process bypass streams provide responsive dynamic trim control of stream temperatures, concentrations, or relative humidities without disrupting upstream equilibrium.

Applying material balances to the overall process boundary envelope first eliminates internal recycle variables, instantly resolving fresh feed, net product, and purge flow rates.

Last updated: September 2026

1.3 Recycle, Bypass, and Purge Operations

In industrial chemical manufacture, single-pass reactor conversions are frequently constrained by thermodynamic equilibrium, catalyst selectivity, or thermal runaway limits. To achieve economic viability, chemical plants route unreacted materials back to the reactor via recycle loops , bypass streams around equipment for fine dynamic control, and bleed purge streams to prevent inert accumulation. On the NCEES PE Chemical Exam , problems involving looped flowsheets are among the most heavily weighted calculation questions. Mastering boundary definitions and the relationships connecting overall conversion, single-pass conversion, and purge rates is essential.

Engineering Roles of Flowsheet Loops

Configuration Flow Architecture Primary Engineering Objectives Classic Industrial Examples

Recycle Downstream separator effluent returned to mix with fresh unit feed - Maximize overall raw material conversion ( X ov > 95 % X_{\text{ov}} > 95\% X ov ​ > 95% ); - Recover expensive dissolved homogeneous catalysts; - Provide thermal ballast/quench in highly exothermic reactions; - Dilute feed concentration to control reaction kinetics - Haber-Bosch ammonia synthesis; - Methanol synthesis from syngas; - Liquid-liquid extraction solvent loops; - Distillation column reflux

Bypass Fraction of upstream feed routed around a unit and rejoined downstream - Responsive dynamic control of outlet temperature or concentration; - Prevent thermal or mechanical degradation of heat-sensitive materials; - Control humidity or dew point in drying and conditioning - Evaporator juice bypass (flavor preservation); - Heat exchanger bypass for temperature control; - Air conditioning dehumidification

Purge Continuous bleed stream removed from a recycle loop - Prevent accumulation of non-reactive inerts ( N 2 , A r , C H 4 N_2, Ar, CH_4 N 2 ​ , A r , C H 4 ​ ); - Prevent buildup of trace reaction poisons or side products; - Establish steady-state operation in closed loops - Inert argon purge in ammonia loops; - Methane purge in methanol synthesis; - Heavy ends purge in solvent recovery

Single-Pass Conversion vs. Overall Conversion

A critical distinction tested on the PE exam is the mathematical difference between conversion across the reactor vessel alone versus conversion across the entire manufacturing plant envelope:

1. Overall System Conversion ( X ov X_{\text{ov}} X ov ​ )

Evaluated across the Overall Plant Control Envelope (considering only fresh feed entering and net product/waste exiting): X ov = n ˙ A , fresh feed − n ˙ A , net loss n ˙ A , fresh feed X_{\text{ov}} = \frac{\dot{n}_{A, \text{fresh feed}} - \dot{n}_{A, \text{net loss}}}{\dot{n}_{A, \text{fresh feed}}} X ov ​ = n ˙ A , fresh feed ​ n ˙ A , fresh feed ​ − n ˙ A , net loss ​ ​

If unreacted reactant is completely separated from the product stream and recycled with zero purge losses, the overall conversion is 100% , even if the reactor achieves only a 10 % 10\% 10% conversion per pass!

2. Single-Pass Reactor Conversion ( X sp X_{\text{sp}} X sp ​ )

Evaluated across the Reactor Control Envelope (considering the mixed feed entering the reactor and the gross effluent exiting): X sp = n ˙ A , reactor feed − n ˙ A , reactor effluent n ˙ A , reactor feed X_{\text{sp}} = \frac{\dot{n}_{A, \text{reactor feed}} - \dot{n}_{A, \text{reactor effluent}}}{\dot{n}_{A, \text{reactor feed}}} X sp ​ = n ˙ A , reactor feed ​ n ˙ A , reactor feed ​ − n ˙ A , reactor effluent ​ ​

Mathematical Linking Equation

Let F 0 F_0 F 0 ​ be the fresh feed of reactant A A A , R A R_A R A ​ be the recycle molar rate of A A A , and F 1 = F 0 + R A F_1 = F_0 + R_A F 1 ​ = F 0 ​ + R A ​ be the total reactant entering the reactor. Assuming all product is separated and only A A A is recycled without purge: Reactant A reacted in reactor = X sp ⋅ F 1 = X sp ( F 0 + R A ) \text{Reactant } A \text{ reacted in reactor} = X_{\text{sp}} \cdot F_1 = X_{\text{sp}} (F_0 + R_A) Reactant A reacted in reactor = X sp ​ ⋅ F 1 ​ = X sp ​ ( F 0 ​ + R A ​ )

At steady state, the reactant consumed in the reactor must identically equal the net reactant consumed across the entire plant ( X ov ⋅ F 0 X_{\text{ov}} \cdot F_0 X ov ​ ⋅ F 0 ​ ): X sp ( F 0 + R A ) = X ov ⋅ F 0 X_{\text{sp}} (F_0 + R_A) = X_{\text{ov}} \cdot F_0 X sp ​ ( F 0 ​ + R A ​ ) = X ov ​ ⋅ F 0 ​

Solving for the Recycle Ratio of reactant A A A ( R A / F 0 R_A / F_0 R A ​ / F 0 ​ ): R A F 0 = X ov − X sp X sp \frac{R_A}{F_0} = \frac{X_{\text{ov}} - X_{\text{sp}}}{X_{\text{sp}}} F 0 ​ R A ​ ​ = X sp ​ X ov ​ − X sp ​ ​

If X ov = 1.00 X_{\text{ov}} = 1.00 X ov ​ = 1.00 ( 100 % 100\% 100% overall conversion): R A F 0 = 1 − X sp X sp = 1 X sp − 1 \frac{R_A}{F_0} = \frac{1 - X_{\text{sp}}}{X_{\text{sp}}} = \frac{1}{X_{\text{sp}}} - 1 F 0 ​ R A ​ ​ = X sp ​ 1 − X sp ​ ​ = X sp ​ 1 ​ − 1

Exam Rule : If single-pass conversion is X sp = 0.20 X_{\text{sp}} = 0.20 X sp ​ = 0.20 (20%), the recycle ratio must be ( 1 − 0.20 ) / 0.20 = 4.0 (1 - 0.20) / 0.20 = 4.0 ( 1 − 0.20 ) /0.20 = 4.0 . Four moles of reactant must be recycled for every one mole of fresh feed introduced.

The Cardinal Purge Rule & Inert Accumulation

When a fresh feed contains even a minute concentration of an inert species (such as argon in air, or methane in synthesis gas), closing the recycle loop without a bleed stream violates steady-state physics. d M inert d t = m ˙ inert, in − 0 > 0 \frac{dM_{\text{inert}}}{dt} = \dot{m}_{\text{inert, in}} - 0 > 0 d t d M inert ​ ​ = m ˙ inert, in ​ − 0 > 0

Inert continuously accumulates within the loop, increasing system pressure, blanketing catalyst active sites, and eventually forcing an emergency shutdown.

To establish steady state ( d M inert / d t = 0 dM_{\text{inert}}/dt = 0 d M inert ​ / d t = 0 ), a continuous purge stream must be vented from the recycle loop. Because the purge stream is split from the recycle stream, its intensive composition is identical to the recycle stream: x inert, purge = x inert, recycle x_{\text{inert, purge}} = x_{\text{inert, recycle}} x inert, purge ​ = x inert, recycle ​

Important

The Cardinal Purge Rule: At steady state, the total mass/molar rate of inert entering in the fresh feed must identically equal the total mass/molar rate of inert exiting in the purge stream!

n ˙ inert, fresh feed = n ˙ inert, purge \dot{n}_{\text{inert, fresh feed}} = \dot{n}_{\text{inert, purge}} n ˙ inert, fresh feed ​ = n ˙ inert, purge ​ F fresh ⋅ z inert, fresh = F purge ⋅ x inert, purge F_{\text{fresh}} \cdot z_{\text{inert, fresh}} = F_{\text{purge}} \cdot x_{\text{inert, purge}} F fresh ​ ⋅ z inert, fresh ​ = F purge ​ ⋅ x inert, purge ​

Solving for the required continuous purge flow rate: F purge = F fresh ⋅ z inert, fresh x inert, purge F_{\text{purge}} = \frac{F_{\text{fresh}} \cdot z_{\text{inert, fresh}}}{x_{\text{inert, purge}}} F purge ​ = x inert, purge ​ F fresh ​ ⋅ z inert, fresh ​ ​

The Economic Trade-Off of Purge Streams

The purge stream cannot discriminate between inerts and unreacted feedstocks; it bleeds gas at the prevailing recycle loop composition. Consequently, valuable reactants are co-purged at a molar rate equal to F purge ( 1 − x inert, purge ) F_{\text{purge}} (1 - x_{\text{inert, purge}}) F purge ​ ( 1 − x inert, purge ​ ) .

Specifying a lower allowable inert level in the reactor loop requires a higher purge rate , which increases raw material loss and lowers overall conversion.

Specifying a higher allowable inert level reduces feedstock loss, but requires a larger reactor volume, larger heat exchangers, and higher recycle gas compressor power.

Bypass Operations & The Lever-Arm Rule

In bypass configurations, a portion of the feed stream ( B B B ) bypasses a processing unit (such as an evaporator, chiller, or chemical treater) and mixes with the unit effluent ( E out E_{\text{out}} E out ​ ) to produce final product ( P P P ): F fresh = E in + B F_{\text{fresh}} = E_{\text{in}} + B F fresh ​ = E in ​ + B P = E out + B P = E_{\text{out}} + B P = E out ​ + B

For binary concentration blending across the downstream mixing junction: B ⋅ x B + E out ⋅ x E = P ⋅ x P B \cdot x_B + E_{\text{out}} \cdot x_E = P \cdot x_P B ⋅ x B ​ + E out ​ ⋅ x E ​ = P ⋅ x P ​

Substituting P = B + E out P = B + E_{\text{out}} P = B + E out ​ yields the classic lever-arm rule : B E out = x E − x P x P − x B \frac{B}{E_{\text{out}}} = \frac{x_E - x_P}{x_P - x_B} E out ​ B ​ = x P ​ − x B ​ x E ​ − x P ​ ​

  • Comprehensive Worked Numerical Example: Methanol Synthesis Loop
  • Problem Statement

A continuous methanol synthesis plant is fed 1 , 000 kmol/h 1,000\text{ kmol/h} 1 , 000 kmol/h of fresh synthesis gas (Stream 0) containing:

Carbon Monoxide ( CO \text{CO} CO ): 32.0 mol% 32.0\text{ mol\%} 32.0 mol%

Hydrogen ( H 2 \text{H}_2 H 2 ​ ): 64.0 mol% 64.0\text{ mol\%} 64.0 mol% (exact 2:1 stoichiometric ratio to CO \text{CO} CO )

Methane ( CH 4 \text{CH}_4 CH 4 ​ , inert): 4.0 mol% 4.0\text{ mol\%} 4.0 mol%

The overall gas-phase reaction is: CO + 2 H 2 ⇌ CH 3 OH \text{CO} + 2\text{H}_2 \rightleftharpoons \text{CH}_3\text{OH} CO + 2 H 2 ​ ⇌ CH 3 ​ OH

Process Specifications:

Fresh feed combines with a recycle stream (Stream 5) to form the mixed reactor feed (Stream 1).

The catalytic reactor operates with a single-pass conversion of carbon monoxide of X sp = 0.200 X_{\text{sp}} = 0.200 X sp ​ = 0.200 ( 20.0 % 20.0\% 20.0% ).

Reactor effluent (Stream 2) enters a condenser-separator where 100 % 100\% 100% of the synthesized methanol is condensed and recovered as pure liquid product (Stream 3).

The non-condensable gas leaving the separator (Stream 4) contains unreacted CO \text{CO} CO , H 2 \text{H}_2 H 2 ​ , and inert CH 4 \text{CH}_4 CH 4 ​ . This gas is divided into a recycle stream (Stream 5) and a continuous purge stream (Stream 6).

The purge stream flow rate is adjusted to maintain the concentration of methane in the recycle gas at exactly 20.0 mol% CH 4 20.0\text{ mol\% }\text{CH}_4 20.0 mol% CH 4 ​ .

Calculate:

The molar flow rate of the continuous purge stream (Stream 6, kmol/h).

The molar production rate of liquid methanol (Stream 3, kmol/h) and the overall plant conversion of CO \text{CO} CO .

The molar flow rate of the recycle gas (Stream 5, kmol/h) and the recycle ratio ( R / F 0 R / F_0 R / F 0 ​ ).

The molar flow rate and composition of the gas entering the reactor (Stream 1).

Step 1: Overall Process Boundary Envelope

Draw a control volume around the entire plant. Crossing the boundary are:

Input : Fresh Feed ( F 0 = 1 , 000 kmol/h F_0 = 1,000\text{ kmol/h} F 0 ​ = 1 , 000 kmol/h ).

Outputs : Pure liquid methanol ( N 3 N_3 N 3 ​ ), and Purge gas ( P 6 P_6 P 6 ​ ).

Apply the Cardinal Purge Rule to inert methane: Methane In with Fresh Feed = F 0 × z CH 4 , 0 = 1 , 000 × 0.040 = 40.0 kmol/h \text{Methane In with Fresh Feed} = F_0 \times z_{\text{CH}_4, 0} = 1,000 \times 0.040 = 40.0\text{ kmol/h} Methane In with Fresh Feed = F 0 ​ × z CH 4 ​ , 0 ​ = 1 , 000 × 0.040 = 40.0 kmol/h

At steady state, all entering methane must leave in the purge stream: n ˙ CH 4 , 6 = 40.0 kmol/h \dot{n}_{\text{CH}_4, 6} = 40.0\text{ kmol/h} n ˙ CH 4 ​ , 6 ​ = 40.0 kmol/h

Given that the purge stream contains 20.0 mol% CH 4 20.0\text{ mol\% }\text{CH}_4 20.0 mol% CH 4 ​ ( y CH 4 , 6 = 0.200 y_{\text{CH}_4, 6} = 0.200 y CH 4 ​ , 6 ​ = 0.200 ): P 6 = n ˙ CH 4 , 6 y CH 4 , 6 = 40.0 kmol/h 0.200 = 200.0 kmol/h P_6 = \frac{\dot{n}_{\text{CH}_4, 6}}{y_{\text{CH}_4, 6}} = \frac{40.0\text{ kmol/h}}{0.200} = \mathbf{200.0\text{ kmol/h}} P 6 ​ = y CH 4 ​ , 6 ​ n ˙ CH 4 ​ , 6 ​ ​ = 0.200 40.0 kmol/h ​ = 200.0 kmol/h

The required continuous purge rate is 200.0 kmol/h .

Step 2: Purge Stream Composition & Methanol Production

Because CO \text{CO} CO and H 2 \text{H}_2 H 2 ​ enter in an exact 1:2 stoichiometric ratio ( 320 kmol/h CO 320\text{ kmol/h CO} 320 kmol/h CO and 640 kmol/h H 2 640\text{ kmol/h H}_2 640 kmol/h H 2 ​ ) and react in an exact 1:2 ratio, they maintain a 1:2 ratio throughout the entire loop.

In the purge stream (total 200.0 kmol/h 200.0\text{ kmol/h} 200.0 kmol/h ):

Methane: 40.0 kmol/h 40.0\text{ kmol/h} 40.0 kmol/h ( 20.0 mol% 20.0\text{ mol\%} 20.0 mol% )

Remaining syngas ( CO + H 2 \text{CO} + \text{H}_2 CO + H 2 ​ ): 200.0 − 40.0 = 160.0 kmol/h 200.0 - 40.0 = 160.0\text{ kmol/h} 200.0 − 40.0 = 160.0 kmol/h

CO \text{CO} CO in purge: n ˙ CO , 6 = 160.0 3 = 53.33 kmol/h \dot{n}_{\text{CO}, 6} = \frac{160.0}{3} = \mathbf{53.33\text{ kmol/h}} n ˙ CO , 6 ​ = 3 160.0 ​ = 53.33 kmol/h ( y CO , 6 = 0.2667 y_{\text{CO}, 6} = 0.2667 y CO , 6 ​ = 0.2667 )

H 2 \text{H}_2 H 2 ​ in purge: n ˙ H 2 , 6 = 2 × 160.0 3 = 106.67 kmol/h \dot{n}_{\text{H}_2, 6} = \frac{2 \times 160.0}{3} = \mathbf{106.67\text{ kmol/h}} n ˙ H 2 ​ , 6 ​ = 3 2 × 160.0 ​ = 106.67 kmol/h ( y H 2 , 6 = 0.5333 y_{\text{H}_2, 6} = 0.5333 y H 2 ​ , 6 ​ = 0.5333 )

Now perform an overall Carbon balance to find liquid methanol production ( N 3 N_3 N 3 ​ ): Carbon In with Fresh Feed = n ˙ CO , 0 + n ˙ CH 4 , 0 = 320.0 + 40.0 = 360.0 kmol C/h \text{Carbon In with Fresh Feed} = \dot{n}_{\text{CO}, 0} + \dot{n}_{\text{CH}_4, 0} = 320.0 + 40.0 = 360.0\text{ kmol C/h} Carbon In with Fresh Feed = n ˙ CO , 0 ​ + n ˙ CH 4 ​ , 0 ​ = 320.0 + 40.0 = 360.0 kmol C/h Carbon Out in Purge = n ˙ CO , 6 + n ˙ CH 4 , 6 = 53.33 + 40.0 = 93.33 kmol C/h \text{Carbon Out in Purge} = \dot{n}_{\text{CO}, 6} + \dot{n}_{\text{CH}_4, 6} = 53.33 + 40.0 = 93.33\text{ kmol C/h} Carbon Out in Purge = n ˙ CO , 6 ​ + n ˙ CH 4 ​ , 6 ​ = 53.33 + 40.0 = 93.33 kmol C/h Methanol Produced ( N 3 ) = 360.0 − 93.33 = 266.67 kmol/h \text{Methanol Produced } (N_3) = 360.0 - 93.33 = \mathbf{266.67\text{ kmol/h}} Methanol Produced ( N 3 ​ ) = 360.0 − 93.33 = 266.67 kmol/h

Overall conversion of carbon monoxide across the plant: X ov = n ˙ CO , 0 − n ˙ CO , 6 n ˙ CO , 0 = 320.0 − 53.33 320.0 = 266.67 320.0 = 0.8333 (83.33%) X_{\text{ov}} = \frac{\dot{n}_{\text{CO}, 0} - \dot{n}_{\text{CO}, 6}}{\dot{n}_{\text{CO}, 0}} = \frac{320.0 - 53.33}{320.0} = \frac{266.67}{320.0} = \mathbf{0.8333\text{ (83.33\%)}} X ov ​ = n ˙ CO , 0 ​ n ˙ CO , 0 ​ − n ˙ CO , 6 ​ ​ = 320.0 320.0 − 53.33 ​ = 320.0 266.67 ​ = 0.8333 (83.33%)

Step 3: Reactor Feed & Recycle Stream Calculations

From the single-pass conversion specification ( X sp = 0.200 X_{\text{sp}} = 0.200 X sp ​ = 0.200 ): Methanol produced in reactor = CO reacted = X sp × n ˙ CO , 1 \text{Methanol produced in reactor} = \text{CO reacted} = X_{\text{sp}} \times \dot{n}_{\text{CO}, 1} Methanol produced in reactor = CO reacted = X sp ​ × n ˙ CO , 1 ​ 266.67 kmol/h = 0.200 × n ˙ CO , 1 ⟹ n ˙ CO , 1 = 266.67 0.200 = 1 , 333.33 kmol/h 266.67\text{ kmol/h} = 0.200 \times \dot{n}_{\text{CO}, 1} \implies \dot{n}_{\text{CO}, 1} = \frac{266.67}{0.200} = \mathbf{1,333.33\text{ kmol/h}} 266.67 kmol/h = 0.200 × n ˙ CO , 1 ​ ⟹ n ˙ CO , 1 ​ = 0.200 266.67 ​ = 1 , 333.33 kmol/h

Perform a CO \text{CO} CO balance around the fresh feed / recycle mixing junction: n ˙ CO , 1 = n ˙ CO , 0 + n ˙ CO , 5 \dot{n}_{\text{CO}, 1} = \dot{n}_{\text{CO}, 0} + \dot{n}_{\text{CO}, 5} n ˙ CO , 1 ​ = n ˙ CO , 0 ​ + n ˙ CO , 5 ​ 1 , 333.33 = 320.0 + n ˙ CO , 5 ⟹ n ˙ CO , 5 = 1 , 333.33 − 320.0 = 1 , 013.33 kmol/h 1,333.33 = 320.0 + \dot{n}_{\text{CO}, 5} \implies \dot{n}_{\text{CO}, 5} = 1,333.33 - 320.0 = \mathbf{1,013.33\text{ kmol/h}} 1 , 333.33 = 320.0 + n ˙ CO , 5 ​ ⟹ n ˙ CO , 5 ​ = 1 , 333.33 − 320.0 = 1 , 013.33 kmol/h

Because the recycle stream has the exact same intensive composition as the purge stream ( y CO , 5 = 0.2667 = 4 / 15 y_{\text{CO}, 5} = 0.2667 = 4/15 y CO , 5 ​ = 0.2667 = 4/15 ): R 5 = n ˙ CO , 5 y CO , 5 = 1 , 013.333 4 / 15 = 3 , 800.0 kmol/h R_5 = \frac{\dot{n}_{\text{CO}, 5}}{y_{\text{CO}, 5}} = \frac{1,013.333}{4/15} = \mathbf{3,800.0\text{ kmol/h}} R 5 ​ = y CO , 5 ​ n ˙ CO , 5 ​ ​ = 4/15 1 , 013.333 ​ = 3 , 800.0 kmol/h

Recycle ratio relative to fresh feed: R 5 F 0 = 3 , 800.0 kmol/h 1 , 000.0 kmol/h = 3.80 \frac{R_5}{F_0} = \frac{3,800.0\text{ kmol/h}}{1,000.0\text{ kmol/h}} = \mathbf{3.80} F 0 ​ R 5 ​ ​ = 1 , 000.0 kmol/h 3 , 800.0 kmol/h ​ = 3.80

Total non-condensable gas leaving condenser (Stream 4): G 4 = R 5 + P 6 = 3 , 800.0 + 200.0 = 4 , 000.0 kmol/h G_4 = R_5 + P_6 = 3,800.0 + 200.0 = 4,000.0\text{ kmol/h} G 4 ​ = R 5 ​ + P 6 ​ = 3 , 800.0 + 200.0 = 4 , 000.0 kmol/h

  • Recycle fraction of loop gas: 3 , 800 / 4 , 000 = 95.0 % 3,800 / 4,000 = 95.0\% 3 , 800/4 , 000 = 95.0%
  • Purge fraction of loop gas: 200 / 4 , 000 = 5.0 % 200 / 4,000 = 5.0\% 200/4 , 000 = 5.0%
  • Step 4: Flowsheet Stream Summary Table
  • Stream # Stream Description Total (kmol/h) CO (kmol/h) H2 (kmol/h) CH4 (kmol/h) CH3OH (kmol/h)
  • 0 Fresh Feed 1,000.0 320.0 640.0 40.0 0.0
  • 1 Mixed Reactor Feed 4,800.0 1,333.3 2,666.7 800.0 0.0
  • 2 Reactor Effluent 4,266.7 1,066.7 2,133.3 800.0 266.7
  • 3 Pure Liquid Product 266.7 0.0 0.0 0.0 266.7
  • 4 Overhead Gas from Condenser 4,000.0 1,066.7 2,133.3 800.0 0.0
  • 5 Recycle Gas 3,800.0 1,013.3 2,026.7 760.0 0.0
  • 6 Purge Gas Bleed 200.0 53.3 106.7 40.0 0.0

Verification Check :

Reactor feed: F 0 + R 5 = 1 , 000.0 + 3 , 800.0 = 4 , 800.0 kmol/h F_0 + R_5 = 1,000.0 + 3,800.0 = 4,800.0\text{ kmol/h} F 0 ​ + R 5 ​ = 1 , 000.0 + 3 , 800.0 = 4 , 800.0 kmol/h (Matches Stream 1 exactly).

Reactor effluent: In reaction CO + 2 H 2 → CH 3 OH \text{CO} + 2\text{H}_2 \rightarrow \text{CH}_3\text{OH} CO + 2 H 2 ​ → CH 3 ​ OH , Δ n = − 2 \Delta n = -2 Δ n = − 2 moles per mole of methanol formed. Moles contracted = 2 × 266.67 = 533.33 kmol/h = 2 \times 266.67 = 533.33\text{ kmol/h} = 2 × 266.67 = 533.33 kmol/h . Effluent = 4 , 800.0 − 533.33 = 4 , 266.67 kmol/h = 4,800.0 - 533.33 = 4,266.67\text{ kmol/h} = 4 , 800.0 − 533.33 = 4 , 266.67 kmol/h (Matches Stream 2 exactly).

Methane into reactor: 40.0 (fresh) + 760.0 (recycle) = 800.0 kmol/h 40.0\text{ (fresh)} + 760.0\text{ (recycle)} = 800.0\text{ kmol/h} 40.0 (fresh) + 760.0 (recycle) = 800.0 kmol/h . Concentration entering reactor: 800 / 4 , 800 = 16.67 mol% 800 / 4,800 = 16.67\text{ mol\%} 800/4 , 800 = 16.67 mol% .