Study guide
19.3 Emissions Evaluation, Mitigation, and Remediation
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
19.3 Emissions Evaluation, Mitigation, and Remediation
Key Takeaways Explain This Topic AI
Emissions are classified as point sources (stacks and vents), fugitive sources (valve stems, flanges, pump seals, sampling points), and area sources (tank farms, wastewater basins), and each is quantified by a different method.
Electrostatic precipitator efficiency follows the Deutsch-Anderson relation η = 1 − exp ( − w A / Q ) \eta = 1 - \exp(-wA/Q) η = 1 − exp ( − w A / Q ) , so each additional "nine" of collection efficiency requires a fixed additive increment of ln ( 10 ) = 2.303 \ln(10) = 2.303 ln ( 10 ) = 2.303 in the group (wA/Q).
40 CFR 60.18 sets flare operating criteria — a continuous pilot, exit velocity limits, and a net heating value of at least 300 Btu/scf 300\text{ Btu/scf} 300 Btu/scf steam- or air-assisted ( 200 Btu/scf 200\text{ Btu/scf} 200 Btu/scf unassisted) — and EPA credits a flare meeting them with 98% destruction efficiency .
The pollution prevention hierarchy ranks source reduction first , then reuse and recycling, then treatment, and disposal last; an end-of-pipe control device is the least preferred answer when a process change can eliminate the stream.
Groundwater and soil remediation technologies are selected by contaminant volatility and biodegradability: soil vapor extraction and air sparging for volatile organics, bioremediation for biodegradable hydrocarbons, and pump-and-treat where the plume must simply be contained.
Last updated: September 2026
19.3 Emissions Evaluation, Mitigation, and Remediation
The NCEES specification lists Environment (e.g., emissions evaluation, mitigation, remediation) as the third subtopic under Safety, Health, and Environment. It is the subtopic most often absent from PE Chemical preparation, and it is examined the same way as any other unit operation — quantify the stream, select a technology, size it.
1. Classifying and Quantifying Emissions
Source type Examples Usual quantification method
Point Stacks, process vents, flares, incinerator outlets Direct stack testing (EPA reference methods) or continuous emission monitoring (CEMS)
Fugitive Valve stems, flanges, pump and compressor seals, connectors, sampling points EPA Method 21 screening with correlation equations, under an LDAR program
Area Storage tank vents, wastewater basins, cooling towers, landfarms Emission factors (EPA AP-42) or model calculation
Three quantification approaches recur:
Material balance. The most defensible method when the inventory is well measured: what enters minus what leaves in product, waste, and recycle is what was emitted. If a tank farm receives 500,000 kg/yr 500{,}000\text{ kg/yr} 500 , 000 kg/yr of toluene and 499,200 kg/yr 499{,}200\text{ kg/yr} 499 , 200 kg/yr is accounted for in product and shipped waste, the 800 kg/yr 800\text{ kg/yr} 800 kg/yr difference is the emission estimate. The weakness is precision: the emission is a small difference between two large numbers, so a 0.5 % 0.5\% 0.5% metering error swamps the answer.
Emission factors. Published mass of pollutant per unit of activity (per m 3 \text{m}^3 m 3 processed, per tonne produced, per tank turnover). EPA's AP-42 compilation is the standard source. Fast, but factors carry wide uncertainty ratings.
Direct measurement. Most accurate, most expensive, and the basis of compliance demonstration for major point sources.
Storage tank emissions split into working losses (vapor expelled as liquid is pumped in) and breathing losses (vapor expelled as the vapor space heats and expands diurnally). Both are attacked structurally: a floating roof eliminates most of the vapor space and is the standard control for volatile liquids in large fixed-roof service; a nitrogen blanket with a vapor recovery unit handles smaller or higher-value streams.
2. Air Emission Control Technologies
Pollutant Technology Governing relation / typical performance
Particulate, coarse Cyclone (Section 12.4) Lapple cut diameter; ineffective below ∼ 5 μ m \sim 5\ \mu\text{m} ∼ 5 μ m
- Particulate, fine Baghouse > 99 % > 99\% > 99% ; sized by air-to-cloth ratio
- Particulate, fine, high volume Electrostatic precipitator Deutsch-Anderson, below
- VOC, dilute high volume Carbon adsorption (Section 12.3) Breakthrough curve, regeneration by steam
VOC, concentrated Thermal or catalytic oxidizer ≥ 99 % \ge 99\% ≥ 99% destruction typical; RCRA incinerators require 99.99 % 99.99\% 99.99% DRE on principal organic hazardous constituents
VOC, intermittent / emergency Flare 98 % 98\% 98% destruction credited when operated within 40 CFR 60.18 criteria
Acid gas, SO 2 \text{SO}_2 SO 2 , HCl \text{HCl} HCl Wet scrubber (Section 12.1) Absorption with caustic or limestone slurry
NO x \text{NO}_x NO x SCR (ammonia + catalyst), low- NO x \text{NO}_x NO x burners 80 − 90 % 80-90\% 80 − 90% reduction
The Deutsch-Anderson equation for an electrostatic precipitator: η = 1 − exp ( − w A Q ) \eta = 1 - \exp\!\left( -\frac{w A}{Q} \right) η = 1 − exp ( − Q w A )
where (w) is the particle migration velocity , (A) the collecting plate area, and (Q) the gas volumetric flow.
Worked example. w = 0.10 m/s w = 0.10\text{ m/s} w = 0.10 m/s , A = 3,000 m 2 A = 3{,}000\text{ m}^2 A = 3 , 000 m 2 , Q = 50 m 3 /s Q = 50\text{ m}^3\text{/s} Q = 50 m 3 /s : w A Q = ( 0.10 ) ( 3,000 ) 50 = 6.00 η = 1 − e − 6.00 = 1 − 0.00248 = 99.75 % \frac{wA}{Q} = \frac{(0.10)(3{,}000)}{50} = 6.00 \qquad \eta = 1 - e^{-6.00} = 1 - 0.00248 = 99.75\% Q w A = 50 ( 0.10 ) ( 3 , 000 ) = 6.00 η = 1 − e − 6.00 = 1 − 0.00248 = 99.75%
Now tighten the permit to 99.9 % 99.9\% 99.9% . Required w A / Q = ln ( 1 / 0.001 ) = 6.908 wA/Q = \ln(1/0.001) = 6.908 w A / Q = ln ( 1/0.001 ) = 6.908 , so (A) must rise by (6.908/6.00 = 1.15), a 15 % 15\% 15% area increase. But going from 99 % 99\% 99% to 99.9 % 99.9\% 99.9% requires (wA/Q) to rise from (4.605) to (6.908) — an additive increment of ln ( 10 ) = 2.303 \ln(10) = 2.303 ln ( 10 ) = 2.303 . Every additional nine costs the same absolute increment of (wA/Q) , so the marginal cost of capture is constant in "nines" and explosive in absolute terms. That structure is why permit limits expressed as 99.99 % 99.99\% 99.99% are enormously more expensive than 99.9 % 99.9\% 99.9% , and it appears identically in adsorption bed depth and in scrubber transfer units.
Flares. 40 CFR 60.18 does not itself state a destruction efficiency; it sets the operating criteria a flare must meet — a continuously present pilot flame, exit velocity below the specified limit, and a net heating value of at least 300 Btu/scf 300\text{ Btu/scf} 300 Btu/scf for steam- or air-assisted flares ( 200 Btu/scf 200\text{ Btu/scf} 200 Btu/scf for unassisted). EPA then credits a flare operated within those criteria with 98 % 98\% 98% destruction efficiency for emission inventory and compliance purposes. Over-steaming a flare quenches the flame and destroys the destruction efficiency, which is why steam ratio is controlled rather than maximized.
3. Water and Waste
Wastewater treatment is staged by contaminant class:
Primary (physical): equalization, oil-water separation (API separator), dissolved air flotation, sedimentation.
Secondary (biological): activated sludge, trickling filter, anaerobic digestion — for biodegradable organic load measured as BOD/COD.
Tertiary (polishing): filtration, carbon adsorption, air stripping (Section 12.1), membranes (Section 12.3), advanced oxidation.
Stream segregation is the highest-leverage decision: mixing a small, concentrated, toxic stream into a large dilute one creates a large toxic stream and forfeits the option of treating the concentrate at its source.
The pollution prevention hierarchy , established by the Pollution Prevention Act of 1990, ranks responses: 1. SOURCE REDUCTION <- eliminate the stream (solvent substitution, leak-free seals,
- improved conversion/selectivity, closed sampling)
- 2. REUSE / RECYCLE <- return it to the process or recover the material
- 3. TREATMENT <- destroy or convert what remains (oxidizer, biotreatment)
- 4. DISPOSAL <- landfill, deep well, incineration without recovery
Exam questions frequently offer a control device where a process change is available. If one option eliminates the stream and another captures it, the hierarchy says eliminate it.
4. The Regulatory Framework
A licensed PE is expected to recognize which statute governs which stream.
Statute Governs Key mechanisms
Clean Air Act (CAA) Air emissions NAAQS, NSPS, NESHAP/MACT standards, Title V operating permits, PSD review for new major sources
Clean Water Act (CWA) Discharges to surface water NPDES permits with numeric effluent limits; pretreatment standards for discharge to POTWs
RCRA Hazardous waste Cradle-to-grave manifest tracking; generator, transporter, and TSDF standards
CERCLA (Superfund) Remediation of contaminated sites Strict, joint and several liability for cleanup of historical releases
EPCRA Community right-to-know Toxics Release Inventory reporting; release notification thresholds
OSHA PSM (29 CFR 1910.119) Process safety (Section 20.1) Fourteen elements including PHA and mechanical integrity
5. Remediation
Once a release has reached soil or groundwater, technology selection is driven by contaminant volatility, solubility, and biodegradability .
Technology Best for Principle
Soil vapor extraction (SVE) Volatile organics in the unsaturated (vadose) zone Vacuum draws vapor from soil pores to a treatment unit
Air sparging Volatile organics below the water table Air injected into the saturated zone strips volatiles into the vadose zone, usually paired with SVE
Pump and treat Plume containment; soluble, non-volatile contaminants Extraction wells create a capture zone; water is treated above ground
Bioremediation Biodegradable hydrocarbons Stimulate indigenous microbes with oxygen and nutrients; in situ or in a landfarm
Permeable reactive barrier Chlorinated solvents, metals Passive trench of reactive medium (e.g., zero-valent iron) intercepts the plume
Thermal desorption / excavation Hot spots, high concentrations Physical removal; fastest, most expensive
Two practical facts shape almost every remediation question. First, pump and treat is very good at containing a plume and very poor at cleaning one up : once the mobile dissolved mass is removed, contaminant desorbs slowly from soil and the effluent concentration plateaus, a phenomenon called tailing , so cleanup asymptotes rather than finishing. Second, dense non-aqueous phase liquids (DNAPLs) such as chlorinated solvents sink below the water table and pool on low-permeability layers, where they act as a long-term source that no groundwater extraction system can reach. Locating and removing the source zone matters more than pumping the plume.