Study guide
5.3 Fundamental Property Relations and Maxwell Equations
PE Chemical Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the PE Chemical Exam How to Use This Guide and the NCEES Handbook
2 Chapter 1: Material Balances & Flowsheet Calculations
1.1 Degree-of-Freedom Analysis & Process Flowsheet Accounting 1.2 Steady-State Material Balances (Reactive & Non-Reactive Systems) 1.3 Recycle, Bypass, and Purge Operations
3 Chapter 2: Energy Balances & Thermochemistry
2.1 Enthalpy Accounting, Sensible Heat, and Phase Changes 2.2 Heats of Reaction, Formation, and Adiabatic Flame Temperatures 2.3 Unsteady-State Mass and Energy Balances
4 Chapter 3: Fluid Statics & Incompressible Pipe Flow
3.1 Fluid Statics, Pressure Measurement, and Manometry 3.2 Incompressible Flow, Friction Factors, and the Moody Diagram 3.3 Minor Losses, Equivalent Length, and Piping Networks 3.4 Pumps, Compressors, and NPSH Calculations
5 Chapter 4: Advanced Fluid Dynamics & Compressible Flow
4.1 Compressible Gas Flow, Sonic Velocity, and Choked Flow 4.2 Flow Measurement Devices (Orifices, Venturis, Rotameters) 4.3 Multiphase Flow and Fluidization Principles 4.4 Mixing, Agitation, and Agitator Scale-Up
6 Chapter 5: Thermodynamic Laws & Fundamental Relations
5.1 First and Second Laws, Heat Engines, and Carnot Efficiency 5.2 Entropy, Availability, and Exergy Analysis 5.3 Fundamental Property Relations and Maxwell Equations
7 Chapter 6: Real Gases & Equations of State
6.1 Volumetric Properties and Compressibility Factor Charts 6.2 Cubic Equations of State (vdW, RK, SRK, and Peng-Robinson) 6.3 Residual Properties and Enthalpy/Entropy Departure Functions
8 Chapter 7: Phase & Chemical Reaction Equilibria
7.1 Pure Component Vapor Pressure and Phase Equilibria 7.2 Vapor-Liquid Equilibrium (VLE), Raoult's Law, and Activity Coefficients 7.3 Chemical Reaction Equilibria and Equilibrium Constant Calculation
9 Chapter 8: Heat Transfer Mechanisms & Conduction
8.1 Steady-State Conduction in Planar, Cylindrical, and Spherical Geometries 8.2 Convective Heat Transfer and Dimensionless Correlations 8.3 Thermal Radiation, Emissivity, and Surface Radiation Exchange
10 Chapter 9: Heat Exchanger Design & Phase Change
9.1 Shell-and-Tube Exchanger Design, TEMA Standards, and LMTD 9.2 Effectiveness-NTU Method and Exchanger Rating 9.3 Boiling Regimes, Condensation Phenomena, and Fouling Resistances
11 Chapter 10: Mass Transfer Fundamentals & Diffusion
10.1 Molecular Diffusion, Fick's Laws, and Equimolar Counterdiffusion 10.2 Convective Mass Transfer and Film Theories 10.3 Mass Transfer Dimensionless Numbers (Sherwood, Schmidt, Peclet)
12 Chapter 11: Distillation Operations
11.1 Vapor-Liquid Equilibrium and Relative Volatility in Distillation 11.2 McCabe-Thiele Method for Binary Distillation 11.3 Packed vs Tray Columns, Flooding, and Tray Hydraulics 11.4 Multicomponent Distillation Fundamentals and Key Components
13 Chapter 12: Rate-Controlled & Equilibrium Separations
12.1 Gas Absorption, Stripping, and the Kremser Equation 12.2 Liquid-Liquid Extraction and Ternary Phase Equilibria 12.3 Adsorption, Membrane Separations, and Drying Operations 12.4 Filtration, Crystallization, and Solid-Fluid Separations
14 Chapter 13: Chemical Kinetics & Ideal Isothermal Reactors
13.1 Reaction Rates, Rate Laws, and Order of Reaction 13.2 Temperature Dependence and the Arrhenius Equation 13.3 Batch Reactors and Continuous Stirred-Tank Reactors (CSTR) 13.4 Plug Flow Reactors (PFR) and Reactor Combinations
15 Chapter 14: Non-Ideal Flow, Non-Isothermal Reactors & Catalysis
14.1 Yield, Selectivity, and Multiple Reactions (Series and Parallel) 14.2 Non-Isothermal Reactor Design and Thermal Runaway 14.3 Heterogeneous Catalysis, Thiele Modulus, and RTD Models
16 Chapter 15: Physical & Transport Properties of Fluids
15.1 Fluid Density, Specific Gravity, and Viscosity Correlations 15.2 Thermal Conductivity and Specific Heat Capacities 15.3 Estimation Methods and Corresponding States Principles
17 Chapter 16: Materials of Construction & Corrosion
16.1 Mechanical Properties and Materials Selection in Chemical Plants 16.2 Corrosion Mechanisms, Materials Degradation, and Prevention
18 Chapter 17: Process Safety & Pressure Relief Systems
17.1 Hazard Identification Methodologies (HAZOP, FMEA, What-If) 17.2 Pressure Relief Valve (PRV) and Rupture Disk Sizing 17.3 Flammability, Explosions, and Toxic Dispersion Limits 17.4 Inerting, Purging, Discharge Location, and Containment
19 Chapter 18: Process Control & Engineering Economics
18.1 Process Dynamics and Feedback Control Loops 18.2 PID Controller Tuning and Loop Stability 18.3 Chemical Plant Capital Cost Estimation and Profitability Analysis 18.4 Field Instrumentation, Control Valves, Alarms, and Safety Instrumented Systems
20 Chapter 19: Process Design, Equipment Selection & Environmental Compliance
19.1 Process Flow Diagrams, P&IDs, Scale-Up, and Plant Siting 19.2 Process Equipment Selection, Sizing, and Optimization 19.3 Emissions Evaluation, Mitigation, and Remediation
21 Chapter 20: Plant Operation, Reliability & Continuous Improvement
20.1 Operating Procedures, Startup, and Shutdown 20.2 Mechanical Integrity, Reliability, and Failure Mechanisms 20.3 Debottlenecking, Optimization, and Troubleshooting
5.3 Fundamental Property Relations and Maxwell Equations
Key Takeaways Explain This Topic AI
The four fundamental property relations for a closed, homogeneous fluid phase are dU = T dS - P dV, dH = T dS + V dP, dA = -S dT - P dV, and dG = -S dT + V dP.
Applying Euler's reciprocity condition of exactness to the four thermodynamic potentials yields the Maxwell relations, which equate unmeasurable entropy derivatives to experimentally accessible P-V-T derivatives.
The fundamental enthalpy derivative with respect to pressure is (dH/dP)_T = V - T * (dV/dT)_P = V * (1 - beta * T), which vanishes identically for ideal gases but governs high-pressure real fluid behavior and enthalpy departure functions.
The Joule-Thomson coefficient mu_JT = (dT/dP)_H = [T * (dV/dT)_P - V] / C_p = V * (beta * T - 1) / C_p determines whether an adiabatic throttling expansion causes cooling (mu_JT > 0), heating (mu_JT < 0), or neither (mu_JT = 0 at the inversion temperature).
The difference between constant-pressure and constant-volume heat capacities is fundamentally C_p - C_v = T * (dP/dT)_V * (dV/dT)_P = T * V * beta^2 / kappa_T, proving that C_p >= C_v for all thermodynamically stable fluid and solid phases.
Last updated: September 2026
5.3 Fundamental Property Relations and Maxwell Equations
Chemical engineers cannot directly measure abstract thermodynamic properties such as internal energy ( U U U ), enthalpy ( H H H ), entropy ( S S S ), Helmholtz energy ( A A A ), or Gibbs free energy ( G G G ) using field instrumentation. Plant transmitters measure only temperature ( T T T ), pressure ( P P P ), volume ( V V V ), and compositions ( x i x_i x i ). Fundamental property relations and Maxwell equations provide the mathematical bridge that converts differential changes in unmeasurable thermodynamic potentials into rigorous expressions involving only measurable P P P - V V V - T T T coordinates and heat capacities. On the NCEES PE Chemical Exam , mastery of these relations is essential for deriving enthalpy departure functions, evaluating Joule-Thomson cooling, and calculating real fluid property changes.
1. The Four Fundamental Property Relations
For a closed, homogeneous system of constant composition undergoing an internally reversible process, combining the First Law ( d U = δ Q r e v − δ W r e v dU = \delta Q_{rev} - \delta W_{rev} d U = δ Q re v − δ W re v ) with the Second Law ( δ Q r e v = T d S \delta Q_{rev} = T dS δ Q re v = T d S and δ W r e v = P d V \delta W_{rev} = P dV δ W re v = P d V ) yields the fundamental property relation for internal energy : d U = T d S − P d V dU = T dS - P dV d U = T d S − P d V
Although derived assuming a reversible process, because U U U , T T T , S S S , P P P , and V V V are all state functions, d U = T d S − P d V dU = T dS - P dV d U = T d S − P d V is universally valid for any process (reversible or irreversible) between equilibrium states in a homogeneous fluid of constant composition .
By applying Legendre transforms to U U U , three additional thermodynamic potentials are systematically generated:
Enthalpy ( H ≡ U + P V H \equiv U + PV H ≡ U + P V ) : d H = d ( U + P V ) = d U + P d V + V d P = ( T d S − P d V ) + P d V + V d P dH = d(U + PV) = dU + P dV + V dP = (T dS - P dV) + P dV + V dP d H = d ( U + P V ) = d U + P d V + V d P = ( T d S − P d V ) + P d V + V d P d H = T d S + V d P dH = T dS + V dP d H = T d S + V d P
Helmholtz Free Energy ( A ≡ U − T S A \equiv U - TS A ≡ U − TS ) : d A = d ( U − T S ) = d U − T d S − S d T = ( T d S − P d V ) − T d S − S d T dA = d(U - TS) = dU - T dS - S dT = (T dS - P dV) - T dS - S dT d A = d ( U − TS ) = d U − T d S − S d T = ( T d S − P d V ) − T d S − S d T d A = − S d T − P d V dA = -S dT - P dV d A = − S d T − P d V
Gibbs Free Energy ( G ≡ H − T S = U + P V − T S G \equiv H - TS = U + PV - TS G ≡ H − TS = U + P V − TS ) : d G = d ( H − T S ) = d H − T d S − S d T = ( T d S + V d P ) − T d S − S d T dG = d(H - TS) = dH - T dS - S dT = (T dS + V dP) - T dS - S dT d G = d ( H − TS ) = d H − T d S − S d T = ( T d S + V d P ) − T d S − S d T d G = − S d T + V d P dG = -S dT + V dP d G = − S d T + V d P
Natural (Canonical) Variables
Each thermodynamic potential possesses a set of natural variables that appear as the differentials on the right-hand side of its fundamental relation:
U = U ( S , V ) ⟹ ( ∂ U ∂ S ) V = T , ( ∂ U ∂ V ) S = − P U = U(S, V) \implies \left(\frac{\partial U}{\partial S}\right)_V = T, \quad \left(\frac{\partial U}{\partial V}\right)_S = -P U = U ( S , V ) ⟹ ( ∂ S ∂ U ) V = T , ( ∂ V ∂ U ) S = − P
H = H ( S , P ) ⟹ ( ∂ H ∂ S ) P = T , ( ∂ H ∂ P ) S = V H = H(S, P) \implies \left(\frac{\partial H}{\partial S}\right)_P = T, \quad \left(\frac{\partial H}{\partial P}\right)_S = V H = H ( S , P ) ⟹ ( ∂ S ∂ H ) P = T , ( ∂ P ∂ H ) S = V
A = A ( T , V ) ⟹ ( ∂ A ∂ T ) V = − S , ( ∂ A ∂ V ) T = − P A = A(T, V) \implies \left(\frac{\partial A}{\partial T}\right)_V = -S, \quad \left(\frac{\partial A}{\partial V}\right)_T = -P A = A ( T , V ) ⟹ ( ∂ T ∂ A ) V = − S , ( ∂ V ∂ A ) T = − P
G = G ( T , P ) ⟹ ( ∂ G ∂ T ) P = − S , ( ∂ G ∂ P ) T = V G = G(T, P) \implies \left(\frac{\partial G}{\partial T}\right)_P = -S, \quad \left(\frac{\partial G}{\partial P}\right)_T = V G = G ( T , P ) ⟹ ( ∂ T ∂ G ) P = − S , ( ∂ P ∂ G ) T = V
- Note
- The Chemical Engineer's Preferred Potential: Gibbs Free Energy ( G G G )
In chemical process design, reactions and phase changes almost universally occur under controlled temperature and pressure conditions ( T , P T, P T , P ). Because the natural variables of Gibbs free energy are precisely T T T and P P P , d G = − S d T + V d P dG = -S dT + V dP d G = − S d T + V d P forms the computational foundation for phase equilibria (VLE, LLE), fugacity, and chemical reaction equilibrium constants ( K e q K_{eq} K e q ).
2. Exact Differentials and the Four Maxwell Relations
Mathematically, if a continuous state function z ( x , y ) z(x, y) z ( x , y ) has continuous second partial derivatives, its differential d z = M d x + N d y dz = M dx + N dy d z = M d x + N d y is an exact differential . By Schwarz's theorem (Euler's reciprocity relation), the order of mixed second partial differentiation is commutative: ∂ 2 z ∂ y ∂ x = ∂ 2 z ∂ x ∂ y ⟹ ( ∂ M ∂ y ) x = ( ∂ N ∂ x ) y \frac{\partial^2 z}{\partial y \, \partial x} = \frac{\partial^2 z}{\partial x \, \partial y} \implies \left( \frac{\partial M}{\partial y} \right)_x = \left( \frac{\partial N}{\partial x} \right)_y ∂ y ∂ x ∂ 2 z = ∂ x ∂ y ∂ 2 z ⟹ ( ∂ y ∂ M ) x = ( ∂ x ∂ N ) y
Applying this reciprocity condition to each of the four fundamental property relations yields the four classical Maxwell relations :
Maxwell Relation 1 (from d U = T d S − P d V dU = T dS - P dV d U = T d S − P d V ): ( ∂ T ∂ V ) S = − ( ∂ P ∂ S ) V \left( \frac{\partial T}{\partial V} \right)_S = -\left( \frac{\partial P}{\partial S} \right)_V ( ∂ V ∂ T ) S = − ( ∂ S ∂ P ) V
Maxwell Relation 2 (from d H = T d S + V d P dH = T dS + V dP d H = T d S + V d P ): ( ∂ T ∂ P ) S = ( ∂ V ∂ S ) P \left( \frac{\partial T}{\partial P} \right)_S = \left( \frac{\partial V}{\partial S} \right)_P ( ∂ P ∂ T ) S = ( ∂ S ∂ V ) P
Maxwell Relation 3 (from d A = − S d T − P d V dA = -S dT - P dV d A = − S d T − P d V ): ( ∂ S ∂ V ) T = ( ∂ P ∂ T ) V \left( \frac{\partial S}{\partial V} \right)_T = \left( \frac{\partial P}{\partial T} \right)_V ( ∂ V ∂ S ) T = ( ∂ T ∂ P ) V
Maxwell Relation 4 (from d G = − S d T + V d P dG = -S dT + V dP d G = − S d T + V d P ): ( ∂ S ∂ P ) T = − ( ∂ V ∂ T ) P \left( \frac{\partial S}{\partial P} \right)_T = -\left( \frac{\partial V}{\partial T} \right)_P ( ∂ P ∂ S ) T = − ( ∂ T ∂ V ) P
Tip
Mnemonic Strategy for Maxwell Relations: Notice the symmetry across the equations: the cross-derivatives relate ( T , S ) (T, S) ( T , S ) to ( P , V ) (P, V) ( P , V ) .
Relations holding temperature constant ( d A dA d A and d G dG d G ) feature entropy derivatives on the left: ( ∂ S / ∂ V ) T (\partial S / \partial V)_T ( ∂ S / ∂ V ) T and ( ∂ S / ∂ P ) T (\partial S / \partial P)_T ( ∂ S / ∂ P ) T .
Watch the negative signs: V V V and P P P carry negative signs when paired with S S S and T T T as dictated by the signs in d A = − S d T − P d V dA = -S dT - P dV d A = − S d T − P d V and d G = − S d T + V d P dG = -S dT + V dP d G = − S d T + V d P .
3. Measurable P P P - V V V - T T T Coefficients and Bridgman Transformations
To apply Maxwell relations to practical fluid mechanics and heat transfer, chemical engineers express volumetric derivatives using two standardized physical properties:
Isobaric Thermal Expansivity ( β \beta β ) :
The fractional change in volume with temperature at constant pressure: β ≡ 1 V ( ∂ V ∂ T ) P \beta \equiv \frac{1}{V} \left( \frac{\partial V}{\partial T} \right)_P β ≡ V 1 ( ∂ T ∂ V ) P
Isothermal Compressibility ( κ T \kappa_T κ T ) :
The fractional reduction in volume with pressure at constant temperature (defined with a negative sign so that κ T > 0 \kappa_T > 0 κ T > 0 for stable phases): κ T ≡ − 1 V ( ∂ V ∂ P ) T \kappa_T \equiv -\frac{1}{V} \left( \frac{\partial V}{\partial P} \right)_T κ T ≡ − V 1 ( ∂ P ∂ V ) T
From the cyclic triple product rule of partial differentiation: ( ∂ P ∂ T ) V ( ∂ T ∂ V ) P ( ∂ V ∂ P ) T = − 1 ⟹ ( ∂ P ∂ T ) V = − ( ∂ V / ∂ T ) P ( ∂ V / ∂ P ) T = β V κ T V = β κ T \left( \frac{\partial P}{\partial T} \right)_V \left( \frac{\partial T}{\partial V} \right)_P \left( \frac{\partial V}{\partial P} \right)_T = -1 \implies \left( \frac{\partial P}{\partial T} \right)_V = -\frac{(\partial V / \partial T)_P}{(\partial V / \partial P)_T} = \frac{\beta V}{\kappa_T V} = \frac{\beta}{\kappa_T} ( ∂ T ∂ P ) V ( ∂ V ∂ T ) P ( ∂ P ∂ V ) T = − 1 ⟹ ( ∂ T ∂ P ) V = − ( ∂ V / ∂ P ) T ( ∂ V / ∂ T ) P = κ T V β V = κ T β
Derivation of Internal Energy Variation with Volume: ( ∂ U / ∂ V ) T (\partial U / \partial V)_T ( ∂ U / ∂ V ) T
How does internal energy change during isothermal expansion?
Start with d U = T d S − P d V dU = T dS - P dV d U = T d S − P d V . Divide by d V dV d V holding T T T constant: ( ∂ U ∂ V ) T = T ( ∂ S ∂ V ) T − P \left( \frac{\partial U}{\partial V} \right)_T = T \left( \frac{\partial S}{\partial V} \right)_T - P ( ∂ V ∂ U ) T = T ( ∂ V ∂ S ) T − P
Substitute Maxwell Relation 3 [ ( ∂ S / ∂ V ) T = ( ∂ P / ∂ T ) V (\partial S / \partial V)_T = (\partial P / \partial T)_V ( ∂ S / ∂ V ) T = ( ∂ P / ∂ T ) V ]: ( ∂ U ∂ V ) T = T ( ∂ P ∂ T ) V − P = T ( β κ T ) − P \left( \frac{\partial U}{\partial V} \right)_T = T \left( \frac{\partial P}{\partial T} \right)_V - P = T \left( \frac{\beta}{\kappa_T} \right) - P ( ∂ V ∂ U ) T = T ( ∂ T ∂ P ) V − P = T ( κ T β ) − P
For an ideal gas ( P = R T / V P = RT/V P = RT / V ): ( ∂ P ∂ T ) V = R V = P T ⟹ ( ∂ U ∂ V ) T = T ( P T ) − P = 0 \left( \frac{\partial P}{\partial T} \right)_V = \frac{R}{V} = \frac{P}{T} \implies \left( \frac{\partial U}{\partial V} \right)_T = T \left(\frac{P}{T}\right) - P = 0 ( ∂ T ∂ P ) V = V R = T P ⟹ ( ∂ V ∂ U ) T = T ( T P ) − P = 0
This rigorously proves Joule's Law: the internal energy of an ideal gas is strictly a function of temperature alone ( U = U ( T ) U = U(T) U = U ( T ) ).
Derivation of Enthalpy Variation with Pressure: ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T
How does enthalpy change during isothermal compression?
Start with d H = T d S + V d P dH = T dS + V dP d H = T d S + V d P . Divide by d P dP d P holding T T T constant: ( ∂ H ∂ P ) T = T ( ∂ S ∂ P ) T + V \left( \frac{\partial H}{\partial P} \right)_T = T \left( \frac{\partial S}{\partial P} \right)_T + V ( ∂ P ∂ H ) T = T ( ∂ P ∂ S ) T + V
Substitute Maxwell Relation 4 [ ( ∂ S / ∂ P ) T = − ( ∂ V / ∂ T ) P (\partial S / \partial P)_T = -(\partial V / \partial T)_P ( ∂ S / ∂ P ) T = − ( ∂ V / ∂ T ) P ]: ( ∂ H ∂ P ) T = V − T ( ∂ V ∂ T ) P = V ( 1 − β T ) \left( \frac{\partial H}{\partial P} \right)_T = V - T \left( \frac{\partial V}{\partial T} \right)_P = V (1 - \beta T) ( ∂ P ∂ H ) T = V − T ( ∂ T ∂ V ) P = V ( 1 − βT )
For an ideal gas ( V = R T / P ⟹ ( ∂ V / ∂ T ) P = R / P = V / T V = RT/P \implies (\partial V / \partial T)_P = R/P = V/T V = RT / P ⟹ ( ∂ V / ∂ T ) P = R / P = V / T ): ( ∂ H ∂ P ) T = V − T ( V T ) = 0 \left( \frac{\partial H}{\partial P} \right)_T = V - T \left(\frac{V}{T}\right) = 0 ( ∂ P ∂ H ) T = V − T ( T V ) = 0
This proves that ideal gas enthalpy is strictly independent of pressure ( H = H ( T ) H = H(T) H = H ( T ) ).
For real fluids at high pressure , ( ∂ H / ∂ P ) T ≠ 0 (\partial H / \partial P)_T \ne 0 ( ∂ H / ∂ P ) T = 0 ; integrating this expression from zero pressure to system pressure yields the enthalpy departure function : H − H i g = ∫ 0 P [ V − T ( ∂ V ∂ T ) P ] d P H - H^{ig} = \int_0^P \left[ V - T \left(\frac{\partial V}{\partial T}\right)_P \right] dP H − H i g = ∫ 0 P [ V − T ( ∂ T ∂ V ) P ] d P
4. Joule-Thomson Expansion and the Inversion Curve
When a high-pressure fluid stream is continuously throttled through a flow restriction (porous plug, cracked orifice, or throttling valve) with no heat exchange ( Q ˙ = 0 \dot{Q} = 0 Q ˙ = 0 ) and no shaft work ( W ˙ s = 0 \dot{W}_s = 0 W ˙ s = 0 ), the process is isenthalpic ( h 1 = h 2 h_1 = h_2 h 1 = h 2 ).
The rate of temperature change with respect to pressure drop at constant enthalpy is defined as the Joule-Thomson coefficient ( μ J T \mu_{JT} μ J T ): μ J T ≡ ( ∂ T ∂ P ) H \mu_{JT} \equiv \left( \frac{\partial T}{\partial P} \right)_H μ J T ≡ ( ∂ P ∂ T ) H
Applying the cyclic triple product rule to ( T , P , H ) (T, P, H) ( T , P , H ) : ( ∂ T ∂ P ) H ( ∂ P ∂ H ) T ( ∂ H ∂ T ) P = − 1 \left( \frac{\partial T}{\partial P} \right)_H \left( \frac{\partial P}{\partial H} \right)_T \left( \frac{\partial H}{\partial T} \right)_P = -1 ( ∂ P ∂ T ) H ( ∂ H ∂ P ) T ( ∂ T ∂ H ) P = − 1 μ J T = − ( ∂ H / ∂ P ) T ( ∂ H / ∂ T ) P = − 1 C p ( ∂ H ∂ P ) T \mu_{JT} = -\frac{(\partial H / \partial P)_T}{(\partial H / \partial T)_P} = -\frac{1}{C_p} \left( \frac{\partial H}{\partial P} \right)_T μ J T = − ( ∂ H / ∂ T ) P ( ∂ H / ∂ P ) T = − C p 1 ( ∂ P ∂ H ) T
Substituting ( ∂ H / ∂ P ) T = V − T ( ∂ V / ∂ T ) P (\partial H / \partial P)_T = V - T (\partial V / \partial T)_P ( ∂ H / ∂ P ) T = V − T ( ∂ V / ∂ T ) P : μ J T = T ( ∂ V ∂ T ) P − V C p = V ( β T − 1 ) C p \mu_{JT} = \frac{T \left( \frac{\partial V}{\partial T} \right)_P - V}{C_p} = \frac{V (\beta T - 1)}{C_p} μ J T = C p T ( ∂ T ∂ V ) P − V = C p V ( βT − 1 )
Physical Behavior During Throttling ( d P < 0 dP < 0 d P < 0 )
Because pressure always drops during flow through a restriction ( d P < 0 dP < 0 d P < 0 ), the sign of μ J T \mu_{JT} μ J T dictates the temperature response: Δ T ≈ μ J T Δ P \Delta T \approx \mu_{JT} \Delta P Δ T ≈ μ J T Δ P
μ J T > 0 \mu_{JT} > 0 μ J T > 0 (Cooling Regime) :
Condition: β T > 1 \beta T > 1 βT > 1 , or T ( ∂ V / ∂ T ) P > V T (\partial V / \partial T)_P > V T ( ∂ V / ∂ T ) P > V .
Result: Fluid cools upon expansion ( d T < 0 dT < 0 d T < 0 when d P < 0 dP < 0 d P < 0 ).
Industrial application: Liquefaction of natural gas (Linde-Hampson cycle), refrigeration expansion valves.
μ J T < 0 \mu_{JT} < 0 μ J T < 0 (Heating Regime) :
Condition: β T < 1 \beta T < 1 βT < 1 , or T ( ∂ V / ∂ T ) P < V T (\partial V / \partial T)_P < V T ( ∂ V / ∂ T ) P < V .
Result: Fluid warms upon expansion ( d T > 0 dT > 0 d T > 0 when d P < 0 dP < 0 d P < 0 ).
Critical safety hazard: Hydrogen, helium, and neon at ambient temperature possess negative Joule-Thomson coefficients. Throttling high-pressure hydrogen gas can heat it above its autoignition temperature, creating spontaneous fire hazards!
μ J T = 0 \mu_{JT} = 0 μ J T = 0 (Inversion Curve) :
Condition: β T = 1 \beta T = 1 βT = 1 , or T ( ∂ V / ∂ T ) P = V T (\partial V / \partial T)_P = V T ( ∂ V / ∂ T ) P = V .
The locus of states where μ J T = 0 \mu_{JT} = 0 μ J T = 0 defines the Joule-Thomson inversion curve on a T T T - P P P diagram. The maximum temperature on this boundary is the maximum inversion temperature ( T i n v , m a x T_{inv, max} T in v , ma x ). Below T i n v T_{inv} T in v , gases can be cooled by throttling.
5. Fundamental Relation for Heat Capacity Difference: C p − C v C_p - C_v C p − C v
The general thermodynamic relationship connecting constant-pressure and constant-volume heat capacities is derived from entropy differentials: C p − C v = T ( ∂ P ∂ T ) V ( ∂ V ∂ T ) P C_p - C_v = T \left( \frac{\partial P}{\partial T} \right)_V \left( \frac{\partial V}{\partial T} \right)_P C p − C v = T ( ∂ T ∂ P ) V ( ∂ T ∂ V ) P
Substituting ( ∂ P / ∂ T ) V = β / κ T (\partial P / \partial T)_V = \beta / \kappa_T ( ∂ P / ∂ T ) V = β / κ T and ( ∂ V / ∂ T ) P = V β (\partial V / \partial T)_P = V \beta ( ∂ V / ∂ T ) P = V β : C p − C v = T V β 2 κ T C_p - C_v = \frac{T V \beta^2}{\kappa_T} C p − C v = κ T T V β 2
Engineering Consequences of C p − C v C_p - C_v C p − C v
Thermodynamic Stability : For any stable thermodynamic phase, absolute temperature T > 0 T > 0 T > 0 , volume V > 0 V > 0 V > 0 , and isothermal compressibility κ T > 0 \kappa_T > 0 κ T > 0 (compression reduces volume). Because β 2 \beta^2 β 2 is inherently non-negative: C p − C v ≥ 0 ⟹ C p ≥ C v C_p - C_v \ge 0 \implies C_p \ge C_v C p − C v ≥ 0 ⟹ C p ≥ C v C p C_p C p can never be smaller than C v C_v C v for a stable substance!
Incompressible Liquids : For ideal liquids, thermal expansivity is very small ( β ≈ 0 \beta \approx 0 β ≈ 0 ). Therefore, C p ≈ C v = C C_p \approx C_v = C C p ≈ C v = C .
Ideal Gases : For an ideal gas, β = 1 / T \beta = 1/T β = 1/ T and κ T = 1 / P \kappa_T = 1/P κ T = 1/ P . Substituting gives: C p − C v = T V ( 1 / T 2 ) 1 / P = P V T = R C_p - C_v = \frac{T V (1/T^2)}{1/P} = \frac{P V}{T} = R C p − C v = 1/ P T V ( 1/ T 2 ) = T P V = R Re-deriving Mayer's classical relation C p − C v = R C_p - C_v = R C p − C v = R .
6. Summary Table: Thermodynamic Potentials, Maxwell Relations, and Measurable Equivalents
Potential Natural Variables Fundamental Differential Associated Maxwell Relation Key Derived Physical Property
Internal Energy ( U U U ) ( S , V ) (S, V) ( S , V ) d U = T d S − P d V dU = T dS - P dV d U = T d S − P d V ( ∂ T ∂ V ) S = − ( ∂ P ∂ S ) V \left(\frac{\partial T}{\partial V}\right)_S = -\left(\frac{\partial P}{\partial S}\right)_V ( ∂ V ∂ T ) S = − ( ∂ S ∂ P ) V ( ∂ U ∂ V ) T = T ( ∂ P ∂ T ) V − P \left(\frac{\partial U}{\partial V}\right)_T = T\left(\frac{\partial P}{\partial T}\right)_V - P ( ∂ V ∂ U ) T = T ( ∂ T ∂ P ) V − P
Enthalpy ( H H H ) ( S , P ) (S, P) ( S , P ) d H = T d S + V d P dH = T dS + V dP d H = T d S + V d P ( ∂ T ∂ P ) S = ( ∂ V ∂ S ) P \left(\frac{\partial T}{\partial P}\right)_S = \left(\frac{\partial V}{\partial S}\right)_P ( ∂ P ∂ T ) S = ( ∂ S ∂ V ) P ( ∂ H ∂ P ) T = V − T ( ∂ V ∂ T ) P \left(\frac{\partial H}{\partial P}\right)_T = V - T\left(\frac{\partial V}{\partial T}\right)_P ( ∂ P ∂ H ) T = V − T ( ∂ T ∂ V ) P
Helmholtz Energy ( A A A ) ( T , V ) (T, V) ( T , V ) d A = − S d T − P d V dA = -S dT - P dV d A = − S d T − P d V ( ∂ S ∂ V ) T = ( ∂ P ∂ T ) V \left(\frac{\partial S}{\partial V}\right)_T = \left(\frac{\partial P}{\partial T}\right)_V ( ∂ V ∂ S ) T = ( ∂ T ∂ P ) V Equation of state pressure: P = − ( ∂ A / ∂ V ) T P = -(\partial A / \partial V)_T P = − ( ∂ A / ∂ V ) T
Gibbs Energy ( G G G ) ( T , P ) (T, P) ( T , P ) d G = − S d T + V d P dG = -S dT + V dP d G = − S d T + V d P ( ∂ S ∂ P ) T = − ( ∂ V ∂ T ) P \left(\frac{\partial S}{\partial P}\right)_T = -\left(\frac{\partial V}{\partial T}\right)_P ( ∂ P ∂ S ) T = − ( ∂ T ∂ V ) P Residual volume / fugacity: V = ( ∂ G / ∂ P ) T V = (\partial G / \partial P)_T V = ( ∂ G / ∂ P ) T
7. Critical PE Exam Traps & Pitfalls
- Warning
- PE Exam Trap 1: The Negative Sign in the Gibbs Maxwell Relation
The Maxwell relation derived from d G dG d G is ( ∂ S / ∂ P ) T = − ( ∂ V / ∂ T ) P (\partial S / \partial P)_T = -(\partial V / \partial T)_P ( ∂ S / ∂ P ) T = − ( ∂ V / ∂ T ) P . Forgetting the negative sign will cause you to calculate the wrong sign for entropy changes during compression ( d P > 0 dP > 0 d P > 0 ), falsely showing that entropy increases during isothermal gas compression!
Warning
PE Exam Trap 2: Blindly Assuming ( ∂ H / ∂ P ) T = 0 (\partial H / \partial P)_T = 0 ( ∂ H / ∂ P ) T = 0 for Real Fluids
While ( ∂ H / ∂ P ) T = 0 (\partial H / \partial P)_T = 0 ( ∂ H / ∂ P ) T = 0 is true for an ideal gas, it is never zero for real gases at elevated pressures or for liquids. When calculating high-pressure boiler feed pumps or high-pressure gas compressors, the mechanical enthalpy contribution ∫ [ V − T ( ∂ V / ∂ T ) P ] d P \int [V - T(\partial V/\partial T)_P] dP ∫ [ V − T ( ∂ V / ∂ T ) P ] d P is non-zero and must be included.
- Warning
- PE Exam Trap 3: Reversing the Sign of Joule-Thomson Temperature Change
Remember that throttling expansion involves a pressure drop ( Δ P = P 2 − P 1 < 0 \Delta P = P_2 - P_1 < 0 Δ P = P 2 − P 1 < 0 ). If μ J T = + 0.25 K/bar \mu_{JT} = +0.25\text{ K/bar} μ J T = + 0.25 K/bar , then Δ T = μ J T Δ P = ( + 0.25 ) × ( − 20 bar ) = − 5.0 K \Delta T = \mu_{JT} \Delta P = (+0.25) \times (-20\text{ bar}) = -5.0\text{ K} Δ T = μ J T Δ P = ( + 0.25 ) × ( − 20 bar ) = − 5.0 K (a 5.0 K 5.0\text{ K} 5.0 K drop in temperature). Candidates frequently forget that Δ P \Delta P Δ P is negative, erroneously predicting that positive μ J T \mu_{JT} μ J T produces heating.
- 8. Step-by-Step Worked Numerical Example: Real Gas Enthalpy Departure and Joule-Thomson Throttling
- Problem Statement
A high-pressure chemical synthesis reactor feed loop compresses pure nitrogen gas ( N 2 N_2 N 2 , M W = 28.01 g/mol MW = 28.01\text{ g/mol} M W = 28.01 g/mol ) at a constant temperature of T = 300.0 K T = 300.0\text{ K} T = 300.0 K from an initial pressure of P 1 = 0.100 MPa P_1 = 0.100\text{ MPa} P 1 = 0.100 MPa ( 1.00 bar 1.00\text{ bar} 1.00 bar ) to a reactor feed pressure of P 2 = 10.00 MPa P_2 = 10.00\text{ MPa} P 2 = 10.00 MPa ( 100.0 bar 100.0\text{ bar} 100.0 bar ).
Over this pressure range at 300.0 K 300.0\text{ K} 300.0 K , nitrogen behaves according to the truncated volumetric equation of state: V = R T P + b − a R T V = \frac{RT}{P} + b - \frac{a}{RT} V = P RT + b − RT a
Where:
R = 8.314 J/(mol ⋅ K) R = 8.314\text{ J/(mol}\cdot\text{K)} R = 8.314 J/(mol ⋅ K)
C p = 29.12 J/(mol ⋅ K) C_p = 29.12\text{ J/(mol}\cdot\text{K)} C p = 29.12 J/(mol ⋅ K) (constant over this range)
- a = 0.1370 J ⋅ m 3 / mol 2 a = 0.1370\text{ J}\cdot\text{m}^3/\text{mol}^2 a = 0.1370 J ⋅ m 3 / mol 2
- b = 3.870 × 10 − 5 m 3 / mol b = 3.870 \times 10^{-5}\text{ m}^3/\text{mol} b = 3.870 × 1 0 − 5 m 3 / mol
Calculate:
Derive the analytical expression for ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T for this gas.
Calculate the numerical value of ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T in units of m 3 / mol \text{m}^3/\text{mol} m 3 / mol (or J/(mol ⋅ Pa) \text{J/(mol}\cdot\text{Pa)} J/(mol ⋅ Pa) ) at 300.0 K 300.0\text{ K} 300.0 K .
Calculate the molar enthalpy change ( Δ H \Delta H Δ H ) of nitrogen during this isothermal compression from 1.00 bar 1.00\text{ bar} 1.00 bar to 100.0 bar 100.0\text{ bar} 100.0 bar . Compare this to an ideal gas.
Derive the analytical expression for the Joule-Thomson coefficient ( μ J T \mu_{JT} μ J T ) and evaluate its numerical value at 300.0 K 300.0\text{ K} 300.0 K in units of K/bar \text{K/bar} K/bar .
If high-pressure nitrogen at 10.00 MPa 10.00\text{ MPa} 10.00 MPa and 300.0 K 300.0\text{ K} 300.0 K is suddenly throttled across an emergency relief valve to atmospheric pressure ( 0.100 MPa 0.100\text{ MPa} 0.100 MPa ), estimate the resulting stream exit temperature ( T 2 T_2 T 2 ).
Calculate the Joule-Thomson inversion temperature ( T i n v T_{inv} T in v ) for this equation of state.
- Step-by-Step Solution
- Step 1: Analytical Derivation of ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T
From fundamental thermodynamics: ( ∂ H ∂ P ) T = V − T ( ∂ V ∂ T ) P \left( \frac{\partial H}{\partial P} \right)_T = V - T \left( \frac{\partial V}{\partial T} \right)_P ( ∂ P ∂ H ) T = V − T ( ∂ T ∂ V ) P
Differentiate the equation of state with respect to T T T at constant P P P : V = R T P + b − a R T V = \frac{RT}{P} + b - \frac{a}{RT} V = P RT + b − RT a ( ∂ V ∂ T ) P = R P + 0 − ( − a R T 2 ) = R P + a R T 2 \left( \frac{\partial V}{\partial T} \right)_P = \frac{R}{P} + 0 - \left( -\frac{a}{R T^2} \right) = \frac{R}{P} + \frac{a}{RT^2} ( ∂ T ∂ V ) P = P R + 0 − ( − R T 2 a ) = P R + R T 2 a
Substitute ( ∂ V / ∂ T ) P (\partial V / \partial T)_P ( ∂ V / ∂ T ) P into the enthalpy derivative: ( ∂ H ∂ P ) T = ( R T P + b − a R T ) − T ( R P + a R T 2 ) \left( \frac{\partial H}{\partial P} \right)_T = \left( \frac{RT}{P} + b - \frac{a}{RT} \right) - T \left( \frac{R}{P} + \frac{a}{RT^2} \right) ( ∂ P ∂ H ) T = ( P RT + b − RT a ) − T ( P R + R T 2 a ) ( ∂ H ∂ P ) T = R T P + b − a R T − R T P − a R T \left( \frac{\partial H}{\partial P} \right)_T = \frac{RT}{P} + b - \frac{a}{RT} - \frac{RT}{P} - \frac{a}{RT} ( ∂ P ∂ H ) T = P RT + b − RT a − P RT − RT a ( ∂ H ∂ P ) T = b − 2 a R T \mathbf{\left( \frac{\partial H}{\partial P} \right)_T = b - \frac{2a}{RT}} ( ∂P ∂H ) T = b − RT 2a
(Notice that P P P has completely canceled out; for this equation of state, ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T depends solely on temperature!)
Step 2: Numerical Evaluation of ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T at 300.0 K 300.0\text{ K} 300.0 K
Calculate R T RT RT : R T = ( 8.314 J/(mol ⋅ K) ) × ( 300.0 K ) = 2 , 494.2 J/mol RT = (8.314\text{ J/(mol}\cdot\text{K)}) \times (300.0\text{ K}) = 2,494.2\text{ J/mol} RT = ( 8.314 J/(mol ⋅ K) ) × ( 300.0 K ) = 2 , 494.2 J/mol
Calculate 2 a / ( R T ) 2a / (RT) 2 a / ( RT ) : 2 a R T = 2 × 0.1370 J ⋅ m 3 / mol 2 2 , 494.2 J/mol = 0.2740 2 , 494.2 = 1.09855 × 10 − 4 m 3 / mol \frac{2a}{RT} = \frac{2 \times 0.1370\text{ J}\cdot\text{m}^3/\text{mol}^2}{2,494.2\text{ J/mol}} = \frac{0.2740}{2,494.2} = 1.09855 \times 10^{-4}\text{ m}^3/\text{mol} RT 2 a = 2 , 494.2 J/mol 2 × 0.1370 J ⋅ m 3 / mol 2 = 2 , 494.2 0.2740 = 1.09855 × 1 0 − 4 m 3 / mol
Now evaluate ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T : ( ∂ H ∂ P ) T = ( 3.870 × 10 − 5 ) − ( 10.9855 × 10 − 5 ) = − 7.1155 × 10 − 5 m 3 / mol ( or J/(mol ⋅ Pa) ) \left( \frac{\partial H}{\partial P} \right)_T = (3.870 \times 10^{-5}) - (10.9855 \times 10^{-5}) = \mathbf{-7.1155 \times 10^{-5}\text{ m}^3/\text{mol} \quad (\text{or J/(mol}\cdot\text{Pa)})} ( ∂ P ∂ H ) T = ( 3.870 × 1 0 − 5 ) − ( 10.9855 × 1 0 − 5 ) = − 7.1155 × 1 0 − 5 m 3 / mol ( or J/(mol ⋅ Pa) )
Step 3: Enthalpy Change During Isothermal Compression
Because ( ∂ H / ∂ P ) T (\partial H / \partial P)_T ( ∂ H / ∂ P ) T is independent of pressure, integration is direct: Δ H = ∫ P 1 P 2 ( ∂ H ∂ P ) T d P = ( b − 2 a R T ) ( P 2 − P 1 ) \Delta H = \int_{P_1}^{P_2} \left( \frac{\partial H}{\partial P} \right)_T dP = \left( b - \frac{2a}{RT} \right) (P_2 - P_1) Δ H = ∫ P 1 P 2 ( ∂ P ∂ H ) T d P = ( b − RT 2 a ) ( P 2 − P 1 )
Pressure difference in Pascals: P 2 − P 1 = 10.00 × 10 6 Pa − 0.100 × 10 6 Pa = 9.90 × 10 6 Pa P_2 - P_1 = 10.00 \times 10^6\text{ Pa} - 0.100 \times 10^6\text{ Pa} = 9.90 \times 10^6\text{ Pa} P 2 − P 1 = 10.00 × 1 0 6 Pa − 0.100 × 1 0 6 Pa = 9.90 × 1 0 6 Pa
Calculate Δ H \Delta H Δ H : Δ H = ( − 7.1155 × 10 − 5 J/(mol ⋅ Pa) ) × ( 9.90 × 10 6 Pa ) = − 704.4 J/mol ( − 0.7044 kJ/mol ) \Delta H = (-7.1155 \times 10^{-5}\text{ J/(mol}\cdot\text{Pa)}) \times (9.90 \times 10^6\text{ Pa}) = \mathbf{-704.4\text{ J/mol} \quad (-0.7044\text{ kJ/mol})} Δ H = ( − 7.1155 × 1 0 − 5 J/(mol ⋅ Pa) ) × ( 9.90 × 1 0 6 Pa ) = − 704.4 J/mol ( − 0.7044 kJ/mol )
Comparison with Ideal Gas : For an ideal gas, ( ∂ H / ∂ P ) T = 0 (\partial H / \partial P)_T = 0 ( ∂ H / ∂ P ) T = 0 , so Δ H i d e a l = 0 \Delta H_{ideal} = 0 Δ H i d e a l = 0 . The real-gas intermolecular attractions cause the fluid enthalpy to decrease by 704.4 J/mol 704.4\text{ J/mol} 704.4 J/mol during compression.
Step 4: Joule-Thomson Coefficient at 300.0 K 300.0\text{ K} 300.0 K μ J T = − 1 C p ( ∂ H ∂ P ) T = 1 C p ( 2 a R T − b ) \mu_{JT} = -\frac{1}{C_p} \left( \frac{\partial H}{\partial P} \right)_T = \frac{1}{C_p} \left( \frac{2a}{RT} - b \right) μ J T = − C p 1 ( ∂ P ∂ H ) T = C p 1 ( RT 2 a − b ) μ J T = − − 7.1155 × 10 − 5 J/(mol ⋅ Pa) 29.12 J/(mol ⋅ K) = + 2.4435 × 10 − 6 K/Pa \mu_{JT} = -\frac{-7.1155 \times 10^{-5}\text{ J/(mol}\cdot\text{Pa)}}{29.12\text{ J/(mol}\cdot\text{K)}} = +2.4435 \times 10^{-6}\text{ K/Pa} μ J T = − 29.12 J/(mol ⋅ K) − 7.1155 × 1 0 − 5 J/(mol ⋅ Pa) = + 2.4435 × 1 0 − 6 K/Pa
Convert to engineering units of K/bar \text{K/bar} K/bar ( 1 bar = 10 5 Pa 1\text{ bar} = 10^5\text{ Pa} 1 bar = 1 0 5 Pa ): μ J T = ( 2.4435 × 10 − 6 K/Pa ) × ( 10 5 Pa/bar ) = + 0.2444 K/bar \mu_{JT} = (2.4435 \times 10^{-6}\text{ K/Pa}) \times (10^5\text{ Pa/bar}) = \mathbf{+0.2444\text{ K/bar}} μ J T = ( 2.4435 × 1 0 − 6 K/Pa ) × ( 1 0 5 Pa/bar ) = + 0.2444 K/bar
Step 5: Throttling Temperature Change Across Relief Valve
The pressure change during throttling is negative: Δ P = P 2 − P 1 = 0.100 MPa − 10.00 MPa = − 9.90 MPa = − 99.0 bar \Delta P = P_2 - P_1 = 0.100\text{ MPa} - 10.00\text{ MPa} = -9.90\text{ MPa} = -99.0\text{ bar} Δ P = P 2 − P 1 = 0.100 MPa − 10.00 MPa = − 9.90 MPa = − 99.0 bar Δ T ≈ μ J T Δ P = ( + 0.2444 K/bar ) × ( − 99.0 bar ) = − 24.19 K ( − 24.2 ∘ C ) \Delta T \approx \mu_{JT} \Delta P = (+0.2444\text{ K/bar}) \times (-99.0\text{ bar}) = \mathbf{-24.19\text{ K} \quad (-24.2^\circ\text{C})} Δ T ≈ μ J T Δ P = ( + 0.2444 K/bar ) × ( − 99.0 bar ) = − 24.19 K ( − 24. 2 ∘ C )
Exiting temperature: T 2 = T 1 + Δ T = 300.0 K − 24.2 K = 275.8 K ( 2.65 ∘ C ) T_2 = T_1 + \Delta T = 300.0\text{ K} - 24.2\text{ K} = \mathbf{275.8\text{ K} \quad (2.65^\circ\text{C})} T 2 = T 1 + Δ T = 300.0 K − 24.2 K = 275.8 K ( 2.6 5 ∘ C )
(Because μ J T > 0 \mu_{JT} > 0 μ J T > 0 , the gas undergoes substantial cooling of 24.2 ∘ C 24.2^\circ\text{C} 24. 2 ∘ C upon depressurization.)
Step 6: Joule-Thomson Inversion Temperature ( T i n v T_{inv} T in v )
The inversion temperature occurs when μ J T = 0 \mu_{JT} = 0 μ J T = 0 : 2 a R T i n v − b = 0 ⟹ T i n v = 2 a R b \frac{2a}{R T_{inv}} - b = 0 \implies T_{inv} = \frac{2a}{R b} R T in v 2 a − b = 0 ⟹ T in v = R b 2 a T i n v = 2 × 0.1370 J ⋅ m 3 / mol 2 ( 8.314 J/(mol ⋅ K) ) × ( 3.870 × 10 − 5 m 3 / mol ) = 0.2740 3.2175 × 10 − 4 = 851.6 K ( 578.4 ∘ C ) T_{inv} = \frac{2 \times 0.1370\text{ J}\cdot\text{m}^3/\text{mol}^2}{(8.314\text{ J/(mol}\cdot\text{K)}) \times (3.870 \times 10^{-5}\text{ m}^3/\text{mol})} = \frac{0.2740}{3.2175 \times 10^{-4}} = \mathbf{851.6\text{ K} \quad (578.4^\circ\text{C})} T in v = ( 8.314 J/(mol ⋅ K) ) × ( 3.870 × 1 0 − 5 m 3 / mol ) 2 × 0.1370 J ⋅ m 3 / mol 2 = 3.2175 × 1 0 − 4 0.2740 = 851.6 K ( 578. 4 ∘ C )
(Conclusion: Since the operating temperature 300.0 K 300.0\text{ K} 300.0 K is well below the inversion temperature of 851.6 K 851.6\text{ K} 851.6 K , nitrogen will always cool upon throttling at ambient conditions.)