Study guide
1.1 PE Power Exam Format, CBT Navigation & Reference Handbook
PE Electrical and Computer: Power Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Strategy & Reference Handbook
1.1 PE Power Exam Format, CBT Navigation & Reference Handbook 1.2 2026 Reference Standards (NEC 2020, NFPA 70E-2021, NESC) & Scoring Mechanics 1.3 CBT Pacing, AIT Question Formats & Formula Sheet Mastery
2 Chapter 2: Measurement, Metering & Field Testing
2.1 Current Transformers (CTs), Potential Transformers (PTs) & Meter Connections 2.2 Instrument Transformer Burdens, Saturation Curves & Ratio Correction Factors 2.3 Insulation Resistance Testing (Megger, Polarization Index, Dielectric Absorption) 2.4 Ground Resistance Testing (Fall-of-Potential 62% Rule & Clamp-on Methods)
3 Chapter 3: General Applications — Grounding & Surge Protection
3.1 Substation Ground Grid Design & IEEE 80 Touch/Step Voltage Criteria 3.2 Lightning Protection Systems & Rolling Sphere / Cone of Protection Methods 3.3 Surge Protective Devices (SPDs) & Voltage Surge Arresters
4 Chapter 4: General Applications — Lighting & Energy Management
4.1 Illumination Engineering & Zonal Cavity / Lumen Method Calculations 4.2 Energy Management, Demand Factors & Load Factor Calculations 4.3 Economic Dispatch, Energy Efficiency & Load Profile Analysis
5 Chapter 5: Electrical Safety & NFPA Standards
5.1 NFPA 70E Shock Protection, Approach Boundaries & PPE Requirements 5.2 Arc-Flash Hazard Analysis & IEEE 1584-2018 Incident Energy Calculations 5.3 Hazardous (Classified) Locations (Class I, II, III & Division/Zone Systems) 5.4 Special Occupancies & Critical Systems (NEC Articles 517 Health Care, 700/701/702 Emergency)
6 Chapter 6: NEC Wiring Methods & Installation Requirements
6.1 Conductor Ampacity & NEC Table 310.16 Derating Adjustments 6.2 Raceway Fill, Box Sizing & Conduit Bending Calculations (Chapter 9 Tables) 6.3 Equipment Grounding Conductors & Grounding Electrode Sizing (NEC Article 250)
7 Chapter 7: Circuit Analysis — Fundamentals & Symmetrical Components
7.1 DC & Single-Phase AC Network Analysis (Thevenin, Norton, Superposition) 7.2 Balanced Three-Phase Circuits (Wye-Delta Configurations & Power Formulas) 7.3 Symmetrical Components & Fortescue Sequence Transformation Matrices 7.4 Sequence Impedances & Positive, Negative, Zero Sequence Network Construction
8 Chapter 8: Circuit Analysis — Per-Unit & Phasor Analysis
8.1 Per-Unit System Fundamentals & Base Conversion Formulas 8.2 Three-Phase Per-Unit Network Modeling & Equipment Impedance Conversion 8.3 Phasor Diagrams, Complex Power & Power Triangle Relationships
9 Chapter 9: Power Electronics & Logic Controls
9.1 Power Electronic Converters (Rectifiers, Inverters & DC-DC Topologies) 9.2 Inverter-Based Resources (IBRs), Grid-Forming & Grid-Following Controls 9.3 Variable Frequency Drives (VFDs), PWM Operation & Harmonic Mitigation 9.4 Boolean Algebra, Logic Gates, De Morgan's Laws & Ladder Logic Control Diagrams
10 Chapter 10: Rotating Machines — Induction & Synchronous
10.1 Three-Phase Induction Motors (Equivalent Circuits, Slip & Performance) 10.2 Induction Motor Torque-Speed Characteristics & NEMA Design Classes 10.3 Synchronous Machines (Operating Principles, Power-Angle Curves & V-Curves) 10.4 Motor Starting Methods (DOL, Wye-Delta, Autotransformer, Soft-Start) & Voltage Dip
11 Chapter 11: Electric Power Devices & Renewable Energy
11.1 Power Transformers (Equivalent Circuits, Efficiency & Voltage Regulation) 11.2 Power Factor Correction Capacitors & Shunt Bank Sizing 11.3 Battery Energy Storage Systems (BESS) & Ultracapacitors 11.4 Renewable Energy Generation (Solar Photovoltaic Systems & Wind Turbines)
12 Chapter 12: Transmission & Distribution — Steady-State & Power Quality
12.1 Transmission Line Modeling, Voltage Drop & Conductor Sizing 12.2 Voltage Regulation, Reactive Power Support & Tap-Changer Controls 12.3 Power Quality, Harmonics, THD & IEEE 519 Compliance 12.4 Power Flow Analysis & System Stability (Steady-State, Transient & Swing Equation)
13 Chapter 13: Transmission & Distribution — Fault Analysis & Transformer Shifts
13.1 Symmetrical Three-Phase Bolted Fault Calculations 13.2 Unsymmetrical Fault Analysis (SLG, L-L, DLG Fault Calculations) 13.3 Transformer Connection Types, Zero-Sequence Paths & 30-Degree Phase Shifts
14 Chapter 14: Protection Systems & Device Coordination
14.1 Overcurrent Protection & Time-Current Characteristic (TCC) Curves 14.2 Protective Relaying Schemes (Differential 87, Distance 21, Undervoltage 27) 14.3 Circuit Breakers, Fuses & Automatic Reclosers 14.4 Protection Coordination, Selectivity & Coordination Time Intervals (CTI)
1.1 PE Power Exam Format, CBT Navigation & Reference Handbook
Key Takeaways Explain This Topic AI
The NCEES PE Electrical and Computer: Power exam consists of 80 total questions administered as a Computer-Based Test (CBT) across an 8-hour testing window (9-hour total appointment including breaks and tutorial).
Candidates navigate an electronic, searchable PDF of the NCEES PE Electrical and Computer: Power Reference Handbook (current October 2025 edition) on a split-screen monitor alongside test questions.
The exam is strictly closed-book; only NCEES-approved calculators (such as the TI-36X Pro, Casio fx-115/991 series, or HP 35s) and provided spiral-bound dry-erase scratch booklets are permitted.
An effective pacing baseline requires budgeting an average of 6.0 minutes per question across two separate 40-question modules split by the scheduled break.
Last updated: August 2026
1.1 PE Power Exam Format, CBT Navigation & Reference Handbook
Executive Overview: The NCEES Principles and Practice of Engineering (PE) Electrical and Computer: Power examination is an 80-question, computer-based test (CBT) representing the final technical hurdle for professional engineering licensure. Success requires not only deep theoretical mastery of power engineering disciplines—such as circuits, rotating machines, power system analysis, and protection—but also rapid operational proficiency within the Pearson VUE electronic testing interface, the split-screen searchable NCEES PE Power Reference Handbook , and approved scientific calculators.
1. Exam Appointment Breakdown & Testing Structure
The PE Power examination is administered year-round at Pearson VUE professional testing centers. The total testing appointment is 9 hours (540 minutes) , structured into distinct sequential phases:
Phase Allocated Duration Description & Operational Rules
Nondisclosure Agreement (NDA) 2 minutes Mandatory onscreen confidentiality terms. If not accepted within 2 minutes, the exam ends and the appointment and exam fees are forfeited.
Tutorial 8 minutes Interface mechanics: advancing questions, flagging for review, handbook and design-standard navigation.
Morning Session (Module 1) ~4.0 hours (flexible) Approximately 40 questions spanning all syllabus domains. Time spent here directly reduces time available for Module 2.
Scheduled Break 50 minutes Optional, off-the-clock break. Initiating the break permanently locks Module 1 questions from further review.
Afternoon Session (Module 2) ~4.0 hours (remaining) Approximately 40 questions. Candidates utilize the balance of the total 8-hour testing clock.
Total Appointment 9 hours (540 min) Net Test Clock: 8 hours (480 min) for 80 questions (6.0 min/question average)
Split-Session Dynamics and Question Locking
The exam is split into two independent 40-question modules. While you have a single pool of 8 hours (480 minutes) of active test time, the scheduled 50-minute break acts as an irreversible firewall :
You can freely navigate, flag, and review questions within Module 1 until you submit Module 1 or choose to take your break.
Once you confirm submission of Module 1, you can take up to 50 minutes of break time without depleting your exam timer. Returning early from break does NOT extend your testing clock—per the NCEES Examinee Guide, unused break time never adds to the 8 hours of exam time; it only lets you begin Module 2 sooner.
Crucial Rule: You cannot return to Module 1 after the break. You must budget your time so you do not leave yourself with fewer than 4 hours for Module 2.
2. Pearson VUE CBT Interface & Reference Handbook Mastery
In the testing center, candidates work on a high-resolution widescreen monitor (or dual monitors depending on the station) partitioned into a split-screen configuration:
Left Pane: Displays the active exam question, numerical answer input field or multiple-choice radio buttons, and any associated circuit schematics or one-line exhibits.
Right Pane: Houses the integrated PDF reader containing the searchable NCEES PE Electrical and Computer: Power Reference Handbook (version 2.0) and provided design codes. +---------------------------------------+---------------------------------------+
- | EXAM PANE | REFERENCE PANE |
- | | |
- | [Question 14 of 40] [Flag for Rev] | [ Search: "symmetrical components" ] |
- | | |
- | A 3-phase, 480 V synchronous motor | Bookmarks: |
- | draws 120 A at 0.85 power factor... | > 1. General Power Engineering |
- | | v 2. Circuits & Power System Theory |
- | (A) 55.4 kW | 2.1 Single-Phase Circuits |
- | (B) 72.1 kW | 2.2 Three-Phase Symmetrical... |
- | (C) 84.8 kW | |
- | (D) 99.7 kW | Formula Sheet Display: |
- | | S_3ph = sqrt(3) * V_LL * I_L |
- | [ Previous ] [ Next ] | P_3ph = S_3ph * cos(theta) |
- +---------------------------------------+---------------------------------------+
- Electronic PDF Search Engine Mechanics
The integrated PDF search engine in Pearson VUE is an exact string matcher. Navigating it efficiently requires understanding its specific behaviors:
Literal Matching: Searching for per unit will find instances of "per unit", but will miss hyphenated instances like per-unit unless the search string matches exactly.
Avoid Generic Single Keywords: Searching transformer or voltage will return hundreds of search hits across all chapters, grinding search efficiency to a halt. Instead, search specific compound phrases such as open-circuit test , zero-sequence network , or Kelvin bridge .
Bookmark Navigation Dominance: Top-scoring candidates rely on the PDF table of contents bookmarks pane rather than the search bar for core engineering sections. Memorizing the exact structural hierarchy of the current handbook saves dozens of cumulative minutes:
Section 1: General Power Engineering (Measurement, Instrumentation, Reliability, Special Applications)
Section 2: Circuits (Analysis, Devices & Power Electronic Circuits, Single-Phase & Three-Phase Systems, Symmetrical Components)
Section 3: Rotating Machines & Electric Power Devices (Induction Machines, Synchronous Machines, Transformers, DC Machines)
Section 4: Transmission & Distribution (Transmission Lines, Power Flow, Fault Analysis, System Protection & Relaying)
3. NCEES Calculator Policy & Operational Optimization
NCEES enforces an uncompromising calculator policy. Only models strictly designated on the annual approved list may be brought into the testing center. No other electronic devices, programmable units with external memory cards, or communication-capable tools are permitted.
Approved Calculator Comparison
Calculator Model Series Key Strengths for PE Power Operational Considerations
Texas Instruments TI-36X Pro (Recommended) • Native polar ( r ∠ θ r\angle\theta r ∠ θ ) and rectangular ( a + j b a+jb a + jb ) complex math in both radians and degrees; • 3 × 3 3\times3 3 × 3 matrix inversion for symmetrical component transformations; • Fast polynomial solver for quadratic circuit roots • Highly intuitive multi-tap key layout; • Dedicated [math] menu for vector operations; • Dual solar/battery power reliability
Casio fx-115ES PLUS / fx-991EX ClassWiz / fx-991CW • High-speed matrix calculation engine; • Clean numerical integration display; • Independent complex number calculation mode ( MODE 2 ) • Angle mode (Deg vs Rad) must be verified after entering Complex mode; • Keystroke syntax differs slightly between 991EX and 991CW
Hewlett-Packard HP 35s • Reverse Polish Notation (RPN) option for rapid chaining of long algebraic formulas; • Two-line alphanumeric display • Steep learning curve if not already trained in RPN; • More difficult to source commercially
Essential Calculator Techniques for PE Power
To maintain the necessary 6-minute pace, candidates must execute complex power calculations without manual trigonometric conversions: Example Calculation: Three-Phase Line Current with Complex Impedance
Given:
- V_LL = 480 V (balanced three-phase, line-to-line)
- Load = 45 kVA at 0.80 power factor lagging per phase (delta connection)
- Feeder impedance Z_line = 0.05 + j0.12 ohms per phase
TI-36X Pro Workflow:
1. Ensure Angle Mode is set to DEG (Degrees) via [mode] key.
- 2. Compute phase voltage magnitude: V_LN = 480 / sqrt(3) = 277.128 V
- 3. Express per-phase load complex power: S_1ph = (45 / 3) kVA = 15 kVA
- Power angle theta = arccos(0.80) = 36.87 deg => S_1ph = 15000 /_ 36.87 deg
- 4. Load current conjugate: I_load* = S_1ph / V_LN = 15000 /_ 36.87 / 277.128 /_ 0
- I_load = 54.127 /_ -36.87 deg A
- 5. Voltage drop along feeder: Delta_V = I_load * Z_line
- Enter directly: (54.127 /_ -36.87) * (0.05 + 0.12i) = 7.036 /_ 30.51 deg V
Performing this computation directly using complex arithmetic takes under 25 seconds on a TI-36X Pro, compared to over 2 minutes if decomposed into separate sines and cosines.
4. Scratch Booklet Strategy & Workstation Ergonomics
Pearson VUE provides each candidate with a spiral-bound, laminated grid scratch booklet and ultra-fine point dry-erase markers.
Best Practices for Scratch Booklet Management
The Four-Quadrant Method: Divide every laminated page into four quadrants by drawing a cross. Number each quadrant clearly with the corresponding question number (e.g., Q-12 , Q-13 ). This structure ensures calculations remain neat and allows instant verification if you return to a flagged question.
Marker Cap Discipline: The provided solvent-based dry-erase markers dry out within 30 to 45 seconds if left uncapped on the desk. Develop the muscle memory of clicking the pen cap shut between calculation steps.
Proactive Booklet Replacement: You are not allowed to erase pages yourself using tissues or hands. If you are nearly out of writing surface, raise your hand to request a fresh booklet from the proctor before you run out of space during an active calculation. +-----------------------+-----------------------+
- | Q-17 | Q-18 |
- | S_3ph = sqrt(3)*V*I | Symmetrical Comps: |
- | I = 75000/(sqrt(3)*480| [Ia0] 1 [1 1 1 ] |
- | I = 90.21 A | [Ia1] = - [1 a a2] |
- | P = S*cos(theta) | [Ia2] 3 [1 a2 a ] |
- | P = 75*0.92 = 69 kW | |
- +-----------------------+-----------------------+
- | Q-19 | Q-20 (FLAGGED) |
- | Motor Slip: | X_d" = 0.15 pu |
- | Ns = 120*60/4 = 1800 | S_b = 50 MVA |
- | Nr = 1745 rpm | Check Base Conversion |
- | s = (1800-1745)/1800 | -> Need Pass 2 calc |
- | s = 0.0306 (3.06%) | |
- +-----------------------+-----------------------+
- 5. Common Exam Traps & Strategic Pitfalls
The "Part 1 Overtime" Trap: Spending 4.5 hours on Module 1 because the timer allows it, leaving only 3.5 hours for Module 2. Enforce an internal deadline: click submit on Module 1 no later than the 4:00:00 mark.
Handbook Pluralization Blindspot: Searching relays instead of relay or transformers instead of transformer . Standardize search keywords in singular form.
Degree vs. Radian Mode Inversion: Solving ac power trigonometric equations while the calculator is accidentally set to Radian mode. Verify the DEG annunciator on your screen at the start of every session.
Unflagged Guessing Neglect: Leaving flagged questions blank in hopes of returning to them, only to run out of time. Always enter your best immediate guess before flagging and moving on.