Study guide

7.3 Atmospheric Dispersion Modeling & Indoor Air Quality

PE Environmental Engineering Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 0: Introduction & Exam Overview

0.1 PE Environmental Exam Format & Strategy 0.2 How to Study & Use the NCEES Reference Handbook

2 Chapter 1: Water Quality, Regulations & Supply Hydraulics

1.1 Water Quality Standards, CWA & SDWA 1.2 Water Supply Hydraulics & Pipe Networks 1.3 Hydrology & Groundwater Hydraulics

3 Chapter 2: Physical, Chemical & Biological Water Treatment

2.1 Physical & Chemical Water Treatment 2.2 Water Softening & Advanced Membrane Processes 2.3 Disinfection Kinetics & Chemistry 2.4 Biological Wastewater Treatment & Kinetics

4 Chapter 3: Residuals & Sludge Engineering

3.1 Sludge Thickening & Digestion Kinetics 3.2 Dewatering, Biosolids Disposal & Land Application

5 Chapter 4: Municipal Solid Waste Engineering & Landfills

4.1 Solid Waste Characterization & RCRA Subtitle D 4.2 Collection, Processing & Resource Recovery 4.3 Landfill Engineering & Environmental Controls

6 Chapter 5: Hazardous Waste Engineering & Environmental Sustainability

5.1 Hazardous Waste Characterization & RCRA Subtitle C 5.2 Hazardous Waste Treatment & TSDF Operations 5.3 Life Cycle Assessment (LCA) & Carbon Footprint 5.4 Green Engineering & Sustainable Infrastructure

7 Chapter 6: Air Quality Regulations, Emissions & Particulate Control

6.1 Clean Air Act Regulatory Framework & Pollutants 6.2 Emission Estimation & Continuous Monitoring 6.3 Particulate Matter Control Systems

8 Chapter 7: Gaseous Air Pollution Control & Atmospheric Dispersion

7.1 Gaseous Pollutant Control Technologies 7.2 NOx Control Systems & Combustion Modification 7.3 Atmospheric Dispersion Modeling & Indoor Air Quality

9 Chapter 8: Site Assessment, Hydrogeology & Risk Assessment

8.1 Environmental Site Assessments & Site Characterization 8.2 Subsurface Contaminant Transport & Hydrogeology 8.3 Human Health & Ecological Risk Assessment

10 Chapter 9: Remediation Technologies & Occupational Health

9.1 Soil Remediation Technologies 9.2 Groundwater Remediation Technologies 9.3 Environmental Toxicology & Occupational Health

7.3 Atmospheric Dispersion Modeling & Indoor Air Quality

Key Takeaways Explain This Topic AI

The Gaussian Plume Dispersion Model predicts pollutant concentration downwind based on source emission rate, wind speed, and atmospheric stability.

Effective stack height accounts for the physical stack height plus plume rise (calculated via Holland's equation).

Pasquill-Gifford stability classes (A-F) map environmental lapse rates to atmospheric stability types like looping and coning.

Indoor Air Quality (IAQ) is modeled using mass balance equations, with ASHRAE 62.1 governing ventilation rates to control CO2 and VOCs.

Last updated: July 2026

Atmospheric Dispersion Modeling & Indoor Air Quality (IAQ)

Once gaseous or particulate air pollutants are discharged from elevated industrial stacks or fugitive indoor sources, their movement is governed by atmospheric transport (advection) and turbulent mixing (dispersion). Environmental engineers utilize steady-state Gaussian plume dispersion models to evaluate outdoor downwind ambient concentrations against National Ambient Air Quality Standards (NAAQS), while applying indoor mass balance equations to ensure acceptable Indoor Air Quality (IAQ) under ASHRAE 62.1 standards.

Gaussian Plume Dispersion Model Derivation

The EPA regulatory baseline model assumes continuous emission from a point source into an atmosphere with constant wind speed ( u u u ) along the x x x -axis. Dispersion in the crosswind ( y y y ) and vertical ( z z z ) directions follows double-Gaussian normal probability distributions.

Full Steady-State Gaussian Equation

Including total reflection of the plume at the impenetrable ground surface ( z = 0 z=0 z = 0 ), the downwind ground-level or elevated concentration C ( x , y , z ; H ) C(x,y,z;H) C ( x , y , z ; H ) ( g / m 3 g/m^3 g / m 3 or μ g / m 3 \mu g/m^3 μg / m 3 ) is calculated as: C ( x , y , z ; H ) = Q 2 π u σ y σ z exp ⁡ ( − y 2 2 σ y 2 ) [ exp ⁡ ( − ( z − H ) 2 2 σ z 2 ) + exp ⁡ ( − ( z + H ) 2 2 σ z 2 ) ] C(x,y,z;H) = \frac{Q}{2\pi u \sigma_y \sigma_z} \exp\left(-\frac{y^2}{2\sigma_y^2}\right) \left[ \exp\left(-\frac{(z-H)^2}{2\sigma_z^2}\right) + \exp\left(-\frac{(z+H)^2}{2\sigma_z^2}\right) \right] C ( x , y , z ; H ) = 2 π u σ y ​ σ z ​ Q ​ exp ( − 2 σ y 2 ​ y 2 ​ ) [ exp ( − 2 σ z 2 ​ ( z − H ) 2 ​ ) + exp ( − 2 σ z 2 ​ ( z + H ) 2 ​ ) ]

Where:

  • Q Q Q = Mass emission rate of pollutant ( g / s g/s g / s )
  • u u u = Mean wind speed at effective stack height ( m / s m/s m / s )

σ y , σ z \sigma_y, \sigma_z σ y ​ , σ z ​ = Standard deviations of plume concentration distribution in crosswind and vertical directions ( m m m ). These grow as a function of downwind distance ( x x x ) and Pasquill-Gifford stability class.

  • H H H = Effective stack release height ( m m m )
  • y y y = Crosswind distance from plume centerline ( m m m )
  • z z z = Vertical receptor height above ground ( m m m )
  • Ground-Level Centerline Concentration

For a receptor located directly on the ground ( z = 0 z=0 z = 0 ) along the plume centerline ( y = 0 y=0 y = 0 ), the equation simplifies to: C ( x , 0 , 0 ; H ) = Q π u σ y σ z exp ⁡ ( − H 2 2 σ z 2 ) C(x,0,0;H) = \frac{Q}{\pi u \sigma_y \sigma_z} \exp\left(-\frac{H^2}{2\sigma_z^2}\right) C ( x , 0 , 0 ; H ) = π u σ y ​ σ z ​ Q ​ exp ( − 2 σ z 2 ​ H 2 ​ )

Maximum Ground-Level Concentration Location

The maximum ground-level concentration occurs downwind where σ z ( x ) = H 2 ≈ 0.707 H \sigma_z(x) = \frac{H}{\sqrt{2}} \approx 0.707 H σ z ​ ( x ) = 2 ​ H ​ ≈ 0.707 H : C m a x = 2 Q π e u H 2 ( σ y σ z ) C_{max} = \frac{2 Q}{\pi e u H^2 \left(\frac{\sigma_y}{\sigma_z}\right)} C ma x ​ = π e u H 2 ( σ z ​ σ y ​ ​ ) 2 Q ​

Plume Rise Thermodynamics & Effective Stack Height

The effective stack height ( H H H ) accounts for both the physical stack height ( h s h_s h s ​ ) and the thermal/momentum plume rise ( Δ h \Delta h Δ h ): H = h s + Δ h H = h_s + \Delta h H = h s ​ + Δ h

Holland's Plume Rise Formula

For neutral stability conditions, plume rise is estimated via Holland's equation: Δ h = v s d u [ 1.5 + 2.68 × 10 − 3 P ⋅ d ( T s − T a T s ) ] \Delta h = \frac{v_s d}{u} \left[ 1.5 + 2.68 \times 10^{-3} P \cdot d \left(\frac{T_s - T_a}{T_s}\right) \right] Δ h = u v s ​ d ​ [ 1.5 + 2.68 × 1 0 − 3 P ⋅ d ( T s ​ T s ​ − T a ​ ​ ) ]

Where v s v_s v s ​ is stack exit gas velocity ( m / s m/s m / s ), d d d is inner stack diameter ( m m m ), P P P is atmospheric pressure ( m b mb mb ), T s T_s T s ​ is stack gas temperature ( K K K ), and T a T_a T a ​ is ambient air temperature ( K K K ).

Briggs Buoyancy Flux Parameter

For hot, buoyant plumes, Briggs equations use the Buoyancy Flux ( F F F ) : F = g v s d 2 ( T s − T a 4 T s ) F = g v_s d^2 \left(\frac{T_s - T_a}{4 T_s}\right) F = g v s ​ d 2 ( 4 T s ​ T s ​ − T a ​ ​ )

Pasquill-Gifford Stability Classes & Plume Behavior

Atmospheric stability is classified from Class A (Extremely Unstable) to Class F (Moderately Stable) based on surface wind speed and solar radiation.

Environmental Lapse Rate (ELR) vs. Dry Adiabatic Lapse Rate (DALR)

Stability depends on comparing the actual ELR ( − d T d z -\frac{dT}{dz} − d z d T ​ ) with the DALR ( Γ d = 9.8 ∘ C / k m \Gamma_{d} = 9.8^\circ C/km Γ d ​ = 9. 8 ∘ C / km or 5.4 ∘ F / 1000 f t 5.4^\circ F/1000 \ ft 5. 4 ∘ F /1000 f t ):

Unstable (Superadiabatic, E L R > 9.8 ∘ C / k m ELR > 9.8^\circ C/km E L R > 9. 8 ∘ C / km ): Strong vertical mixing. Produces Looping plumes (Class A/B).

Neutral (Neutral, E L R = 9.8 ∘ C / k m ELR = 9.8^\circ C/km E L R = 9. 8 ∘ C / km ): Moderate mixing. Produces Coning plumes (Class D, overcast day/night).

Stable (Inversion / Subadiabatic, E L R < 9.8 ∘ C / k m ELR < 9.8^\circ C/km E L R < 9. 8 ∘ C / km ): Suppressed vertical mixing. Produces Fanning plumes (Class E/F, clear night).

Lofting Plume: Inversion below stack, unstable above. Highly desirable; traps emissions above ground.

Fumigation Plume: Unstable below stack, inversion aloft (e.g., morning solar heating breaking ground inversion). Dangerous; brings high concentration plume to ground level across a wide area.

Indoor Air Quality (IAQ) Dynamic Mass Balances

Indoor air pollution inside commercial and residential buildings is evaluated using single-zone or multi-zone mass balance models.

Dynamic Governing Equation V d C d t = G + Q C i n − Q C − k V C − E Q r e c C V \frac{dC}{dt} = G + Q C_{in} - Q C - k V C - E Q_{rec} C V d t d C ​ = G + Q C in ​ − QC − kV C − E Q rec ​ C

Where:

  • V V V = Enclosed room volume ( m 3 m^3 m 3 )
  • C ( t ) C(t) C ( t ) = Indoor pollutant concentration ( m g / m 3 mg/m^3 m g / m 3 or p p m ppm pp m )
  • G G G = Indoor generation rate ( m g / h mg/h m g / h )
  • Q Q Q = Outdoor fresh air ventilation rate ( m 3 / h m^3/h m 3 / h )
  • C i n C_{in} C in ​ = Outdoor makeup air pollutant concentration ( m g / m 3 mg/m^3 m g / m 3 )
  • k k k = First-order decay / surface deposition rate constant ( h − 1 h^{-1} h − 1 )
  • E E E = Air cleaner filtration efficiency ( 0 − 1.0 0 - 1.0 0 − 1.0 )
  • Q r e c Q_{rec} Q rec ​ = Recirculated filtration air flow rate ( m 3 / h m^3/h m 3 / h )

Steady-State Solution ( d C / d t = 0 dC/dt = 0 d C / d t = 0 ) C s s = G + Q C i n Q + k V + E Q r e c C_{ss} = \frac{G + Q C_{in}}{Q + k V + E Q_{rec}} C ss ​ = Q + kV + E Q rec ​ G + Q C in ​ ​

If there is no internal decay ( k = 0 k=0 k = 0 ) and no recirculated filtration ( Q r e c = 0 Q_{rec}=0 Q rec ​ = 0 ): C s s = C i n + G Q C_{ss} = C_{in} + \frac{G}{Q} C ss ​ = C in ​ + Q G ​

ASHRAE Standard 62.1 Ventilation Requirements

ASHRAE Standard 62.1 specifies minimum outdoor airflow rates ( Q t o t Q_{tot} Q t o t ​ ) based on human occupant density ( P z P_z P z ​ ) and floor area ( A z A_z A z ​ ): Q t o t = R p P z + R a A z Q_{tot} = R_p P_z + R_a A_z Q t o t ​ = R p ​ P z ​ + R a ​ A z ​

Where R p R_p R p ​ is outdoor air rate per person ( L / s ⋅ p e r s o n L/s\cdot person L / s ⋅ p erso n or c f m / p e r s o n cfm/person c f m / p erso n ) and R a R_a R a ​ is outdoor air rate per area ( L / s ⋅ m 2 L/s\cdot m^2 L / s ⋅ m 2 or c f m / f t 2 cfm/ft^2 c f m / f t 2 ). Human bio-effluent C O 2 CO_2 C O 2 ​ generation ( G C O 2 ≈ 0.005 L / s ⋅ p e r s o n G_{CO2} \approx 0.005 \ L/s \cdot person G CO 2 ​ ≈ 0.005 L / s ⋅ p erso n ) is used as a surrogate indicator for adequate ventilation, maintaining indoor C O 2 < 1000 p p m v CO_2 < 1000 \ ppmv C O 2 ​ < 1000 pp m v ( < 700 p p m v < 700 \ ppmv < 700 pp m v above ambient).

Loading diagram... Atmospheric Dispersion & Plume Behavior