Study guide

7.2 NOx Control Systems & Combustion Modification

PE Environmental Engineering Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 0: Introduction & Exam Overview

0.1 PE Environmental Exam Format & Strategy 0.2 How to Study & Use the NCEES Reference Handbook

2 Chapter 1: Water Quality, Regulations & Supply Hydraulics

1.1 Water Quality Standards, CWA & SDWA 1.2 Water Supply Hydraulics & Pipe Networks 1.3 Hydrology & Groundwater Hydraulics

3 Chapter 2: Physical, Chemical & Biological Water Treatment

2.1 Physical & Chemical Water Treatment 2.2 Water Softening & Advanced Membrane Processes 2.3 Disinfection Kinetics & Chemistry 2.4 Biological Wastewater Treatment & Kinetics

4 Chapter 3: Residuals & Sludge Engineering

3.1 Sludge Thickening & Digestion Kinetics 3.2 Dewatering, Biosolids Disposal & Land Application

5 Chapter 4: Municipal Solid Waste Engineering & Landfills

4.1 Solid Waste Characterization & RCRA Subtitle D 4.2 Collection, Processing & Resource Recovery 4.3 Landfill Engineering & Environmental Controls

6 Chapter 5: Hazardous Waste Engineering & Environmental Sustainability

5.1 Hazardous Waste Characterization & RCRA Subtitle C 5.2 Hazardous Waste Treatment & TSDF Operations 5.3 Life Cycle Assessment (LCA) & Carbon Footprint 5.4 Green Engineering & Sustainable Infrastructure

7 Chapter 6: Air Quality Regulations, Emissions & Particulate Control

6.1 Clean Air Act Regulatory Framework & Pollutants 6.2 Emission Estimation & Continuous Monitoring 6.3 Particulate Matter Control Systems

8 Chapter 7: Gaseous Air Pollution Control & Atmospheric Dispersion

7.1 Gaseous Pollutant Control Technologies 7.2 NOx Control Systems & Combustion Modification 7.3 Atmospheric Dispersion Modeling & Indoor Air Quality

9 Chapter 8: Site Assessment, Hydrogeology & Risk Assessment

8.1 Environmental Site Assessments & Site Characterization 8.2 Subsurface Contaminant Transport & Hydrogeology 8.3 Human Health & Ecological Risk Assessment

10 Chapter 9: Remediation Technologies & Occupational Health

9.1 Soil Remediation Technologies 9.2 Groundwater Remediation Technologies 9.3 Environmental Toxicology & Occupational Health

7.2 NOx Control Systems & Combustion Modification

Key Takeaways Explain This Topic AI

Thermal NOx is formed by the high-temperature oxidation of atmospheric nitrogen, described by the Zeldovich mechanism.

Combustion modifications like Low-NOx Burners (LNB), Overfire Air (OFA), and Flue Gas Recirculation (FGR) reduce NOx formation.

SCR uses a catalyst (V2O5/TiO2) and ammonia to reduce NOx to N2 at 300-400°C with high efficiency.

FGD (scrubbers) use wet limestone to react with SO2 to produce gypsum (CaSO4·2H2O).

Last updated: July 2026

N O x NO_x N O x ​ & S O x SO_x S O x ​ Combustion Control Engineering

Nitrogen oxides ( N O x NO_x N O x ​ , primarily nitric oxide N O NO NO and nitrogen dioxide N O 2 NO_2 N O 2 ​ ) and sulfur oxides ( S O x SO_x S O x ​ , primarily S O 2 SO_2 S O 2 ​ ) are major criteria air pollutants regulated under National Ambient Air Quality Standards (NAAQS). N O x NO_x N O x ​ is a mandatory precursor to ground-level ozone (smog) and nitric acid rain, while S O 2 SO_2 S O 2 ​ drives particulate matter ( P M 2.5 PM_{2.5} P M 2.5 ​ ) and sulfuric acid deposition. Environmental engineers must select and design pre-combustion, combustion modification, and post-combustion control technologies to meet stringent EPA Title V and Prevention of Significant Deterioration (PSD) permit limits.

Mechanisms of N O x NO_x N O x ​ Formation

N O x NO_x N O x ​ is generated during fossil fuel combustion via three distinct chemical reaction pathways:

1. Thermal N O x NO_x N O x ​ (The Zeldovich Mechanism)

Thermal N O x NO_x N O x ​ is formed by the high-temperature oxidation of atmospheric nitrogen ( N 2 N_2 N 2 ​ ) present in combustion air. It dominates in clean gas and distillate oil combustion above 1300 ∘ C 1300^\circ C 130 0 ∘ C ( 2370 ∘ F 2370^\circ F 237 0 ∘ F ). The fundamental chemical kinetics are described by the Extended Zeldovich Mechanism : N 2 + O ⇌ N O + N ( E a = 318 k J / m o l ) N_2 + O \rightleftharpoons NO + N \quad (E_a = 318 \ kJ/mol) N 2 ​ + O ⇌ NO + N ( E a ​ = 318 k J / m o l ) N + O 2 ⇌ N O + O N + O_2 \rightleftharpoons NO + O N + O 2 ​ ⇌ NO + O N + O H ⇌ N O + H N + OH \rightleftharpoons NO + H N + O H ⇌ NO + H

Because the initial step breaking the N ≡ N N \equiv N N ≡ N triple bond has an exceptionally high activation energy ( 318 k J / m o l 318 \ kJ/mol 318 k J / m o l ), the thermal N O x NO_x N O x ​ reaction rate ( d [ N O ] / d t d[NO]/dt d [ NO ] / d t ) exhibits an extreme exponential dependence on temperature ( T T T ) and linear dependence on excess oxygen ( [ O 2 ] [O_2] [ O 2 ​ ] ): d [ N O ] d t = 2 k 1 [ O ] [ N 2 ] = 2 k 1 A 0 [ O 2 ] [ N 2 ] T 1 / 2 exp ⁡ ( − 318 , 000 R T ) \frac{d[NO]}{dt} = 2 k_1 [O][N_2] = \frac{2 k_1 A_0 \sqrt{[O_2]} [N_2]}{T^{1/2}} \exp\left(-\frac{318,000}{R T}\right) d t d [ NO ] ​ = 2 k 1 ​ [ O ] [ N 2 ​ ] = T 1/2 2 k 1 ​ A 0 ​ [ O 2 ​ ] ​ [ N 2 ​ ] ​ exp ( − RT 318 , 000 ​ )

2. Fuel N O x NO_x N O x ​

Fuel N O x NO_x N O x ​ results from the oxidation of nitrogen atoms organically bound within the fuel matrix (e.g., coal containing 0.5 − 2 % N 0.5 - 2\% \ N 0.5 − 2% N , heavy residual oils). Fuel-bound nitrogen compounds ( R − N H 2 , R − C N R-NH_2, R-CN R − N H 2 ​ , R − CN ) volatilize in the flame zone, forming intermediate radicals ( N H i , H C N NH_i, HCN N H i ​ , H CN ) that oxidize into N O NO NO . Fuel N O x NO_x N O x ​ accounts for 50 − 80 % 50 - 80\% 50 − 80% of total N O x NO_x N O x ​ in coal combustion and is strongly sensitive to local stoichiometry (air-fuel ratio) rather than temperature alone.

3. Prompt N O x NO_x N O x ​ (The Fenimore Mechanism)

Prompt N O x NO_x N O x ​ forms rapidly in the immediate flame front under fuel-rich conditions where hydrocarbon radicals ( C H , C H 2 CH, CH_2 C H , C H 2 ​ ) react with atmospheric nitrogen: C H + N 2 ⇌ H C N + N CH + N_2 \rightleftharpoons HCN + N C H + N 2 ​ ⇌ H CN + N H C N + O 2 → ⋯ → N O HCN + O_2 \rightarrow \dots \rightarrow NO H CN + O 2 ​ → ⋯ → NO

Prompt N O x NO_x N O x ​ contributes a minor fraction of overall emissions but establishes a baseline floor in low-temperature combustors.

Combustion Modification Technologies

Combustion controls aim to suppress N O x NO_x N O x ​ formation at the source by lowering peak flame temperatures, reducing excess oxygen in the high-temperature zone, and extending combustion residence time.

Low- N O x NO_x N O x ​ Burners (LNB): Stage the introduction of fuel and air. Air-staged LNBs create a primary fuel-rich, oxygen-deficient combustion zone (inhibiting N O NO NO formation) followed by a secondary burnout zone where remaining air completes combustion at lower peak temperatures ( 30 − 50 % 30 - 50\% 30 − 50% N O x NO_x N O x ​ reduction).

Overfire Air (OFA): Diverts 15 − 30 % 15 - 30\% 15 − 30% of total combustion air from the main burners to ports located higher up in the boiler furnace, ensuring sub-stoichiometric burning in the primary flame zone ( 30 − 40 % 30 - 40\% 30 − 40% N O x NO_x N O x ​ reduction).

Flue Gas Recirculation (FGR): Recirculates 10 − 20 % 10 - 20\% 10 − 20% of cool, inert exhaust gas back into the primary combustion air stream. The recirculated C O 2 CO_2 C O 2 ​ and N 2 N_2 N 2 ​ act as thermal heat sinks, lowering peak flame temperatures below 1300 ∘ C 1300^\circ C 130 0 ∘ C ( 40 − 70 % 40 - 70\% 40 − 70% reduction of Thermal N O x NO_x N O x ​ ).

Post-Combustion Flue Gas Treatment: SCR vs. SNCR

When combustion modifications cannot satisfy permit limits, post-combustion catalytic or non-catalytic chemical reduction systems are installed.

Selective Catalytic Reduction (SCR)

SCR is the most effective N O x NO_x N O x ​ removal technology, capable of > 90 % N O x > 90\% \ NO_x > 90% N O x ​ reduction . Ammonia gas ( N H 3 NH_3 N H 3 ​ ) or vaporized urea is injected into the flue gas and passed over a ceramic honeycomb catalyst bed composed of Vanadium Pentoxide ( V 2 O 5 V_2O_5 V 2 ​ O 5 ​ ) and Tungsten Trioxide ( W O 3 WO_3 W O 3 ​ ) supported on Titanium Dioxide ( T i O 2 TiO_2 T i O 2 ​ ) .

Stoichiometric Reduction Reactions: 4 N O + 4 N H 3 + O 2 → c a t 4 N 2 + 6 H 2 O 4 NO + 4 NH_3 + O_2 \xrightarrow{cat} 4 N_2 + 6 H_2O 4 NO + 4 N H 3 ​ + O 2 ​ c a t ​ 4 N 2 ​ + 6 H 2 ​ O 2 N O 2 + 4 N H 3 + O 2 → c a t 3 N 2 + 6 H 2 O 2 NO_2 + 4 NH_3 + O_2 \xrightarrow{cat} 3 N_2 + 6 H_2O 2 N O 2 ​ + 4 N H 3 ​ + O 2 ​ c a t ​ 3 N 2 ​ + 6 H 2 ​ O

Operating Temperature Window: Strict window of 300 − 400 ∘ C 300 - 400^\circ C 300 − 40 0 ∘ C ( 570 − 750 ∘ F 570 - 750^\circ F 570 − 75 0 ∘ F ) . Below 300 ∘ C 300^\circ C 30 0 ∘ C , catalyst activity drops and unreacted ammonia forms ammonium bisulfate ( N H 4 H S O 4 NH_4HSO_4 N H 4 ​ H S O 4 ​ ), plugging downstream air preheaters. Above 400 ∘ C 400^\circ C 40 0 ∘ C , N H 3 NH_3 N H 3 ​ oxidizes directly into additional N O x NO_x N O x ​ .

Ammonia Slip: Unreacted N H 3 NH_3 N H 3 ​ exiting the reactor. Must be controlled to < 2 − 5 p p m v < 2 - 5 \ ppmv < 2 − 5 pp m v to prevent secondary particulate formation.

Selective Non-Catalytic Reduction (SNCR)

SNCR injects ammonia or aqueous urea directly into the high-temperature upper furnace without a catalyst: 2 ( N H 2 ) 2 C O (urea) + 4 N O + O 2 → 850 − 1100 ∘ C 4 N 2 + 2 C O 2 + 4 H 2 O 2 (NH_2)_2CO \text{ (urea)} + 4 NO + O_2 \xrightarrow{850-1100^\circ C} 4 N_2 + 2 CO_2 + 4 H_2O 2 ( N H 2 ​ ) 2 ​ CO (urea) + 4 NO + O 2 ​ 850 − 110 0 ∘ C ​ 4 N 2 ​ + 2 C O 2 ​ + 4 H 2 ​ O

Operating Temperature Window: Narrow window of 850 − 1100 ∘ C 850 - 1100^\circ C 850 − 110 0 ∘ C ( 1560 − 2000 ∘ F 1560 - 2000^\circ F 1560 − 200 0 ∘ F ) . Below 850 ∘ C 850^\circ C 85 0 ∘ C , reaction kinetics are too slow, causing excessive N H 3 NH_3 N H 3 ​ slip. Above 1100 ∘ C 1100^\circ C 110 0 ∘ C , N H 3 NH_3 N H 3 ​ oxidizes to N O NO NO .

Removal Efficiency: Typically 30 − 50 % 30 - 50\% 30 − 50% , but with drastically lower capital cost than SCR.

Flue Gas Desulfurization (FGD) Systems for S O 2 SO_2 S O 2 ​

Sulfur dioxide ( S O 2 SO_2 S O 2 ​ ) emissions are controlled post-combustion using alkaline sorbent scrubbers.

Wet Limestone Forced Oxidation Scrubbing

Flue gas passes through a counter-current spray tower contacting a limestone ( C a C O 3 CaCO_3 C a C O 3 ​ ) slurry:

Absorption & Neutralization: S O 2 ( g ) + H 2 O ⇌ H 2 S O 3 SO_2(g) + H_2O \rightleftharpoons H_2SO_3 S O 2 ​ ( g ) + H 2 ​ O ⇌ H 2 ​ S O 3 ​ C a C O 3 ( s ) + H 2 S O 3 → C a S O 3 ( s ) + C O 2 ( g ) + H 2 O CaCO_3(s) + H_2SO_3 \rightarrow CaSO_3(s) + CO_2(g) + H_2O C a C O 3 ​ ( s ) + H 2 ​ S O 3 ​ → C a S O 3 ​ ( s ) + C O 2 ​ ( g ) + H 2 ​ O

Forced Air Oxidation: Air is bubbled into the reaction tank to convert calcium sulfite into commercial-grade gypsum ( C a S O 4 ⋅ 2 H 2 O CaSO_4 \cdot 2 H_2O C a S O 4 ​ ⋅ 2 H 2 ​ O ): C a S O 3 + 1 2 O 2 + 2 H 2 O → C a S O 4 ⋅ 2 H 2 O (Gypsum) CaSO_3 + \frac{1}{2} O_2 + 2 H_2O \rightarrow CaSO_4 \cdot 2 H_2O \text{ (Gypsum)} C a S O 3 ​ + 2 1 ​ O 2 ​ + 2 H 2 ​ O → C a S O 4 ​ ⋅ 2 H 2 ​ O (Gypsum)

Wet FGD achieves > 95 − 98 % S O 2 > 95 - 98\% \ SO_2 > 95 − 98% S O 2 ​ removal efficiency .

Dry & Semi-Dry Systems (SDA & DSI)

Spray Dryer Absorber (SDA): Atomizes a lime slurry ( C a ( O H ) 2 Ca(OH)_2 C a ( O H ) 2 ​ ) into the hot flue gas. Water evaporates, producing dry calcium sulfite/sulfate powder captured in a fabric filter baghouse ( 85 − 92 % 85 - 92\% 85 − 92% efficiency).

Dry Sorbent Injection (DSI): Injects dry hydrated lime or sodium bicarbonate (Trona) directly into ductwork ( 50 − 80 % 50 - 80\% 50 − 80% efficiency).

Loading diagram... NOx Control Strategy Flowchart