Study guide

1.3 Hydrology & Groundwater Hydraulics

PE Environmental Engineering Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 0: Introduction & Exam Overview

0.1 PE Environmental Exam Format & Strategy 0.2 How to Study & Use the NCEES Reference Handbook

2 Chapter 1: Water Quality, Regulations & Supply Hydraulics

1.1 Water Quality Standards, CWA & SDWA 1.2 Water Supply Hydraulics & Pipe Networks 1.3 Hydrology & Groundwater Hydraulics

3 Chapter 2: Physical, Chemical & Biological Water Treatment

2.1 Physical & Chemical Water Treatment 2.2 Water Softening & Advanced Membrane Processes 2.3 Disinfection Kinetics & Chemistry 2.4 Biological Wastewater Treatment & Kinetics

4 Chapter 3: Residuals & Sludge Engineering

3.1 Sludge Thickening & Digestion Kinetics 3.2 Dewatering, Biosolids Disposal & Land Application

5 Chapter 4: Municipal Solid Waste Engineering & Landfills

4.1 Solid Waste Characterization & RCRA Subtitle D 4.2 Collection, Processing & Resource Recovery 4.3 Landfill Engineering & Environmental Controls

6 Chapter 5: Hazardous Waste Engineering & Environmental Sustainability

5.1 Hazardous Waste Characterization & RCRA Subtitle C 5.2 Hazardous Waste Treatment & TSDF Operations 5.3 Life Cycle Assessment (LCA) & Carbon Footprint 5.4 Green Engineering & Sustainable Infrastructure

7 Chapter 6: Air Quality Regulations, Emissions & Particulate Control

6.1 Clean Air Act Regulatory Framework & Pollutants 6.2 Emission Estimation & Continuous Monitoring 6.3 Particulate Matter Control Systems

8 Chapter 7: Gaseous Air Pollution Control & Atmospheric Dispersion

7.1 Gaseous Pollutant Control Technologies 7.2 NOx Control Systems & Combustion Modification 7.3 Atmospheric Dispersion Modeling & Indoor Air Quality

9 Chapter 8: Site Assessment, Hydrogeology & Risk Assessment

8.1 Environmental Site Assessments & Site Characterization 8.2 Subsurface Contaminant Transport & Hydrogeology 8.3 Human Health & Ecological Risk Assessment

10 Chapter 9: Remediation Technologies & Occupational Health

9.1 Soil Remediation Technologies 9.2 Groundwater Remediation Technologies 9.3 Environmental Toxicology & Occupational Health

1.3 Hydrology & Groundwater Hydraulics

Key Takeaways Explain This Topic AI

The Rational Method (Q = CiA) estimates peak runoff for small urban watersheds.

The SCS Curve Number method computes runoff volume based on soil type, land use, and antecedent moisture conditions.

Darcy's Law fundamentally describes groundwater flow through porous media.

Transmissivity (T = Kb) quantifies how much water a confined aquifer can transmit horizontally.

The Theis equation and Cooper-Jacob approximation are used to model transient drawdown in aquifers undergoing pumping.

Last updated: July 2026

Hydrology & Groundwater Hydraulics

Environmental engineers must evaluate the movement, distribution, and quality of water above and below the earth's surface. Surface hydrology focuses on rainfall and runoff modeling, while groundwater hydraulics (hydrogeology) focuses on flow through porous media and well pumping dynamics.

  • Surface Hydrology
  • The Rational Method

The Rational Method is widely used for estimating peak surface runoff from small, primarily urban watersheds (typically less than 200 acres). The governing equation is: Q = C ⋅ i ⋅ A Q = C \cdot i \cdot A Q = C ⋅ i ⋅ A

Where:

Q Q Q = Peak runoff rate (cfs)

C C C = Runoff coefficient (dimensionless, representing the fraction of rainfall that becomes runoff. E.g., asphalt might have C = 0.9 C=0.9 C = 0.9 , while a lawn has C = 0.2 C=0.2 C = 0.2 )

i i i = Rainfall intensity (inches/hour), determined from an Intensity-Duration-Frequency (IDF) curve for a duration equal to the Time of Concentration ( t c t_c t c ​ )

A A A = Watershed area (acres)

(Note: While units appear mixed, 1 acre-inch/hour perfectly equates to 1.008 cubic feet per second, allowing the conversion factor to be effectively 1.0)

SCS Curve Number Method

Developed by the Soil Conservation Service (now NRCS), the Curve Number (CN) method estimates total direct runoff volume from a storm event. The CN is an empirical parameter (ranging from 30 to 100) based on hydrologic soil group, land use, treatment, and antecedent moisture condition. Q = ( P − I a ) 2 ( P − I a ) + S Q = \frac{(P - I_a)^2}{(P - I_a) + S} Q = ( P − I a ​ ) + S ( P − I a ​ ) 2 ​

Where:

  • Q Q Q = Runoff depth (inches)
  • P P P = Total rainfall depth (inches)

S S S = Potential maximum retention after runoff begins (inches), calculated as S = 1000 C N − 10 S = \frac{1000}{CN} - 10 S = CN 1000 ​ − 10

  • I a I_a I a ​ = Initial abstraction (inches), commonly estimated as 0.2 S 0.2S 0.2 S
  • Hydrograph Analysis

A hydrograph plots discharge ( Q Q Q ) versus time. A unit hydrograph represents the direct runoff resulting from one inch of excess rainfall generated uniformly over a watershed at a constant rate for a specified duration. It serves as a linear transfer function to predict runoff from storms of any magnitude.

  • Groundwater Hydraulics (Hydrogeology)
  • Darcy's Law

The fundamental equation describing laminar fluid flow through a porous medium is Darcy's Law: Q = − K ⋅ A ⋅ d h d l Q = -K \cdot A \cdot \frac{dh}{dl} Q = − K ⋅ A ⋅ d l d h ​

Where:

Q Q Q = Groundwater flow rate

K K K = Hydraulic conductivity (length/time, representing the permeability of the soil and properties of the fluid)

  • A A A = Cross-sectional area perpendicular to flow
  • d h d l \frac{dh}{dl} d l d h ​ = Hydraulic gradient (change in head over a specific distance)
  • Aquifer Properties

Hydraulic Conductivity ( K K K ): A measure of the ease with which water can move through pore spaces.

Transmissivity ( T T T ): The rate at which water is transmitted through a unit width of an aquifer under a unit hydraulic gradient. For a confined aquifer of thickness b b b , T = K ⋅ b T = K \cdot b T = K ⋅ b .

Storativity ( S S S ): The volume of water an aquifer releases from or takes into storage per unit surface area of the aquifer per unit change in head. In unconfined aquifers, this is essentially the Specific Yield ( S y S_y S y ​ ).

Well Drawdown and Pumping Analysis

When a well is pumped, a cone of depression forms in the potentiometric surface (or water table) around the well.

1. Steady-State Flow (Thiem Equation): When pumping reaches equilibrium and the cone of depression stabilizes, drawdown can be calculated. For a confined aquifer: Q = 2 π T ( h 2 − h 1 ) ln ⁡ ( r 2 / r 1 ) Q = \frac{2 \pi T (h_2 - h_1)}{\ln(r_2/r_1)} Q = ln ( r 2 ​ / r 1 ​ ) 2 π T ( h 2 ​ − h 1 ​ ) ​

Where h 1 h_1 h 1 ​ and h 2 h_2 h 2 ​ are the hydraulic heads at radial distances r 1 r_1 r 1 ​ and r 2 r_2 r 2 ​ from the well.

2. Unconfined Aquifer Drawdown (Dupuit-Forchheimer): In unconfined aquifers, the saturated thickness decreases near the well, complicating the mathematics. The steady-state equation becomes: Q = π K ( h 2 2 − h 1 2 ) ln ⁡ ( r 2 / r 1 ) Q = \frac{\pi K (h_2^2 - h_1^2)}{\ln(r_2/r_1)} Q = ln ( r 2 ​ / r 1 ​ ) π K ( h 2 2 ​ − h 1 2 ​ ) ​

3. Transient Flow (Theis Equation): Before steady-state is reached, the drawdown ( s s s ) at a radial distance ( r r r ) and time ( t t t ) in a confined aquifer is given by the Theis equation: s = Q 4 π T W ( u ) s = \frac{Q}{4 \pi T} W(u) s = 4 π T Q ​ W ( u )

Where W ( u ) W(u) W ( u ) is the well function, and u = r 2 S 4 T t u = \frac{r^2 S}{4 T t} u = 4 Tt r 2 S ​ .

4. Cooper-Jacob Approximation: For small values of u u u (typically u < 0.01 u < 0.01 u < 0.01 , occurring at large times or small distances), the Theis well function can be approximated using a logarithmic expansion: s = 2.3 Q 4 π T log ⁡ 10 ( 2.25 T t r 2 S ) s = \frac{2.3 Q}{4 \pi T} \log_{10}\left(\frac{2.25 T t}{r^2 S}\right) s = 4 π T 2.3 Q ​ lo g 10 ​ ( r 2 S 2.25 Tt ​ )

This linearizes the drawdown against the logarithm of time, making it highly useful for determining aquifer transmissivity and storativity from pump test data by plotting time vs. drawdown on semi-logarithmic paper.