Study guide
2.1 Physical & Chemical Water Treatment
PE Environmental Engineering Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 0: Introduction & Exam Overview
0.1 PE Environmental Exam Format & Strategy 0.2 How to Study & Use the NCEES Reference Handbook
2 Chapter 1: Water Quality, Regulations & Supply Hydraulics
1.1 Water Quality Standards, CWA & SDWA 1.2 Water Supply Hydraulics & Pipe Networks 1.3 Hydrology & Groundwater Hydraulics
3 Chapter 2: Physical, Chemical & Biological Water Treatment
2.1 Physical & Chemical Water Treatment 2.2 Water Softening & Advanced Membrane Processes 2.3 Disinfection Kinetics & Chemistry 2.4 Biological Wastewater Treatment & Kinetics
4 Chapter 3: Residuals & Sludge Engineering
3.1 Sludge Thickening & Digestion Kinetics 3.2 Dewatering, Biosolids Disposal & Land Application
5 Chapter 4: Municipal Solid Waste Engineering & Landfills
4.1 Solid Waste Characterization & RCRA Subtitle D 4.2 Collection, Processing & Resource Recovery 4.3 Landfill Engineering & Environmental Controls
6 Chapter 5: Hazardous Waste Engineering & Environmental Sustainability
5.1 Hazardous Waste Characterization & RCRA Subtitle C 5.2 Hazardous Waste Treatment & TSDF Operations 5.3 Life Cycle Assessment (LCA) & Carbon Footprint 5.4 Green Engineering & Sustainable Infrastructure
7 Chapter 6: Air Quality Regulations, Emissions & Particulate Control
6.1 Clean Air Act Regulatory Framework & Pollutants 6.2 Emission Estimation & Continuous Monitoring 6.3 Particulate Matter Control Systems
8 Chapter 7: Gaseous Air Pollution Control & Atmospheric Dispersion
7.1 Gaseous Pollutant Control Technologies 7.2 NOx Control Systems & Combustion Modification 7.3 Atmospheric Dispersion Modeling & Indoor Air Quality
9 Chapter 8: Site Assessment, Hydrogeology & Risk Assessment
8.1 Environmental Site Assessments & Site Characterization 8.2 Subsurface Contaminant Transport & Hydrogeology 8.3 Human Health & Ecological Risk Assessment
10 Chapter 9: Remediation Technologies & Occupational Health
9.1 Soil Remediation Technologies 9.2 Groundwater Remediation Technologies 9.3 Environmental Toxicology & Occupational Health
2.1 Physical & Chemical Water Treatment
Key Takeaways Explain This Topic AI
Coagulation neutralizes negative surface charges on particles, allowing them to agglomerate.
Alum and ferric chloride are common coagulants; their reactions consume alkalinity and lower pH.
Velocity gradient (G) and GT values are critical for rapid mix and flocculation design.
Sedimentation basin performance is governed by the surface overflow rate (V0 = Q/A).
Filtration head loss can be modeled using the Ergun or Carmen-Kozeny equations.
Last updated: July 2026
Physical & Chemical Water Treatment
Physical and chemical water treatment processes form the backbone of conventional surface water treatment plants. These processes are designed to remove suspended solids, colloidal particles, and dissolved organics that cause turbidity, color, and harbor pathogens.
Coagulation and Flocculation Chemistry
Most natural particles in surface water are negatively charged and repel each other, keeping them in stable suspension. Coagulation is the rapid chemical process of neutralizing these charges. When a coagulant like aluminum sulfate (alum) or ferric chloride is added to water, it hydrolyzes to form highly charged, polynuclear metal species that compress the electrical double layer around particles.
Alum Coagulation Stoichiometry
The reaction of alum (often A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O Al_2(SO_4)_3 \cdot 14H_2O A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O ) with natural alkalinity (represented by calcium bicarbonate) is:
A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O + 3 C a ( H C O 3 ) 2 → 2 A l ( O H ) 3 ( s ) + 3 C a S O 4 + 6 C O 2 + 14 H 2 O Al_2(SO_4)_3 \cdot 14H_2O + 3Ca(HCO_3)_2 \rightarrow 2Al(OH)_3(s) + 3CaSO_4 + 6CO_2 + 14H_2O A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O + 3 C a ( H C O 3 ) 2 → 2 A l ( O H ) 3 ( s ) + 3 C a S O 4 + 6 C O 2 + 14 H 2 O
Notice that this reaction:
- Consumes alkalinity ( 3 3 3 moles of alkalinity per mole of alum)
- Produces carbon dioxide, which can lower the pH
Forms an insoluble precipitate of aluminum hydroxide ( A l ( O H ) 3 Al(OH)_3 A l ( O H ) 3 ), known as sweep floc
If natural alkalinity is insufficient, supplemental alkalinity must be added, usually in the form of lime ( C a ( O H ) 2 Ca(OH)_2 C a ( O H ) 2 ) or soda ash ( N a 2 C O 3 Na_2CO_3 N a 2 C O 3 ). Polymers (cationic, anionic, or non-ionic) are often added as coagulant aids to bridge particles and form larger, denser flocs that settle faster.
Rapid Mix and Flocculation Design
The hydrodynamics of mixing are described by the velocity gradient ( G G G ) , which represents the intensity of mixing. G G G (with units of s − 1 s^{-1} s − 1 ) is defined as:
G = P μ V G = \sqrt{\frac{P}{\mu V}} G = μ V P
Where:
- P P P = Power input (Watts)
- μ \mu μ = Dynamic viscosity of water ( P a ⋅ s Pa \cdot s P a ⋅ s )
- V V V = Volume of the mixing basin ( m 3 m^3 m 3 )
The product of G G G and the hydraulic detention time ( t t t ) gives the dimensionless G T GT GT value , which is a measure of the total work done on the water. For rapid mix, typical G G G values are 700 700 700 to 1 , 000 s − 1 1,000 \ s^{-1} 1 , 000 s − 1 with t t t around 30 30 30 to 60 60 60 seconds, yielding G T GT GT values around 20 , 000 20,000 20 , 000 to 60 , 000 60,000 60 , 000 . Flocculation requires gentler mixing to promote particle collisions without shearing the fragile flocs, with G G G values typically tapering from 70 70 70 to 10 s − 1 10 \ s^{-1} 10 s − 1 over a 20 20 20 to 45 45 45 minute detention time.
Sedimentation Basin Hydraulics
After flocculation, water enters a sedimentation basin where flocs settle by gravity. The most critical design parameter is the Surface Overflow Rate ( V 0 V_0 V 0 ) :
V 0 = Q A V_0 = \frac{Q}{A} V 0 = A Q
Where Q Q Q is the flow rate and A A A is the surface area of the basin. Particles with a settling velocity ( v s v_s v s ) greater than V 0 V_0 V 0 will be completely removed. Particles with v s < V 0 v_s < V_0 v s < V 0 will be removed at a fractional rate of v s / V 0 v_s / V_0 v s / V 0 .
Other key hydraulic parameters include:
Detention Time ( t t t ) : t = V / Q t = V / Q t = V / Q
Weir Loading Rate (WLR) : The flow over the effluent weir per unit length. WLR = Q / L Q / L Q / L , where L L L is the weir length. Typical values are 100 100 100 to 250 m 3 / d a y / m 250 \ m^3/day/m 250 m 3 / d a y / m .
Settling Types
There are four distinct types of settling in water and wastewater treatment:
Type I (Discrete Particle Settling) : Unhindered settling of individual particles (e.g., grit removal). Described by Stokes' Law.
Type II (Flocculant Settling) : Particles agglomerate as they settle, increasing their mass and settling velocity (e.g., primary sedimentation).
Type III (Hindered/Zone Settling) : High particle concentration causes particles to settle as a blanket (e.g., secondary clarifiers).
Type IV (Compression Settling) : Particles physically rest on each other and compress under the weight of overlying layers (e.g., bottom of deep clarifiers or sludge thickeners).
Filtration Kinetics and Head Loss
Filtration removes remaining suspended particles. Rapid sand filters use a single layer of sand, but dual-media filters (anthracite coal over sand) are more common today. Dual-media allows for deeper penetration of particles, increasing the filter run time before backwashing is necessary.
Head loss through a clean filter bed can be modeled using the Carmen-Kozeny equation or the Ergun equation . The basic form of the Carmen-Kozeny equation for laminar flow is:
h L = f ⋅ L d ⋅ v 2 2 g h_L = f \cdot \frac{L}{d} \cdot \frac{v^2}{2g} h L = f ⋅ d L ⋅ 2 g v 2
Where the friction factor f f f depends on the porosity ( ϵ \epsilon ϵ ), sphericity ( ϕ \phi ϕ ), and Reynolds number. Head loss increases over time as particles accumulate in the pores. When head loss reaches a critical threshold or effluent turbidity spikes (particle breakthrough), the filter must be backwashed.
Worked Example: Surface Overflow Rate
A water treatment plant processes 10 , 000 m 3 / d a y 10,000 \ m^3/day 10 , 000 m 3 / d a y through a rectangular clarifier measuring 20 20 20 m long and 10 10 10 m wide. What is the surface overflow rate, and will a particle with a settling velocity of 60 m / d a y 60 \ m/day 60 m / d a y be fully removed?
A = 20 × 10 = 200 m 2 A = 20 \times 10 = 200 \ m^2 A = 20 × 10 = 200 m 2 V 0 = Q A = 10 , 000 200 = 50 m / d a y V_0 = \frac{Q}{A} = \frac{10,000}{200} = 50 \ m/day V 0 = A Q = 200 10 , 000 = 50 m / d a y
Since v s v_s v s ( 60 m / d a y 60 \ m/day 60 m / d a y ) is greater than V 0 V_0 V 0 ( 50 m / d a y 50 \ m/day 50 m / d a y ), the particle will be 100% removed.