Study guide
1.2 In Situ Testing & Field Exploration
PE Civil Geotechnical Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Site Characterization
1.1 Site Data Interpretation & Boring Plans 1.2 In Situ Testing & Field Exploration 1.3 Soil and Rock Classification Systems 1.4 Groundwater Characterization & Hydrogeology
2 Chapter 2: Soil Mechanics, Laboratory Testing, and Analysis
2.1 Weight-Volume Phase Relationships & Index Properties 2.2 Effective Stress & Pore Water Pressure Dynamics 2.3 Shear Strength Principles & Laboratory Testing 2.4 Permeability, Hydraulic Conductivity & Seepage Properties 2.5 Consolidation & Compressibility Analysis
3 Chapter 3: Construction Observation, Monitoring, QA/QC, and Safety
3.1 Earthwork Quality Control & Compaction Verification 3.2 Geotechnical Instrumentation & Field Monitoring 3.3 Trenching, Excavation Safety & OSHA Shoring Requirements 3.4 Erosion, Scour Protection & Slope Protection During Construction
4 Chapter 4: Earthquake Engineering and Dynamic Loads
4.1 Seismic Site Characterization & Ground Motion Hazards 4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment 4.3 Dynamic Soil Properties & Ground Response Analysis 4.4 Pseudostatic Analysis & Seismic Geotechnical Design
5 Chapter 5: Earth Structures, Ground Improvement, and Pavement
5.1 Slope Stability Analysis & Limit Equilibrium Methods 5.2 Embankments, Earth Dams & Levee Geotechnics 5.3 Ground Improvement Techniques & Design 5.4 Geosynthetics in Geotechnical Engineering 5.5 Flexible & Rigid Pavement Subgrades & Buried Utilities 5.6 Landfills, Caps & Containment Systems
6 Chapter 6: Groundwater and Seepage
6.1 Dewatering System Design & Well Drawdown 6.2 Flow Nets & Two-Dimensional Seepage Analysis 6.3 Uplift Pressure, Piping & Heave Safety 6.4 Subsurface Drainage Systems & Filter Criteria
7 Chapter 7: Problematic Soil and Rock Conditions
7.1 Expansive & Collapsible Soil Engineering 7.2 Organic Soils, Sensitive Clays & Soft Marine Deposits 7.3 Corrosive, Frost-Susceptible & Degradable Formations 7.4 Karst Topography, Rock Slopes & Rockfall Hazards
8 Chapter 8: Retaining Structures
8.1 Lateral Earth Pressure Theories 8.2 Rigid Retaining Wall Design 8.3 Flexible Retaining Walls & Sheet Pile Bulkheads 8.4 Temporary Support of Excavations 8.5 Mechanically Stabilized Earth (MSE) Walls & Soil Nail Structures 8.6 Cofferdams, Underpinning & Adjacent Infrastructure Effects
9 Chapter 9: Shallow Foundations
9.1 Ultimate & Allowable Bearing Capacity Theories 9.2 Effective Footing Area, Eccentricity & Combined Footings 9.3 Induced Stress Distribution & Immediate Elastic Settlement 9.4 Consolidation Settlement & Mat/Raft Foundation Design
10 Chapter 10: Deep Foundations
10.1 Driven Pile Axial Capacity & Settlement 10.2 Drilled Shaft Axial Design & Construction Methods 10.3 Lateral Load Behavior of Deep Foundations 10.4 Pile Group Dynamics, Efficiency & Downdrag 10.5 Dynamic Load Testing & Pile Integrity Evaluation
1.2 In Situ Testing & Field Exploration
Key Takeaways Explain This Topic AI
The Cone Penetration Test (CPTU) provides continuous profiles of tip resistance (qc), sleeve friction (fs), and pore water pressure (u2), allowing Soil Behavior Type (SBT) determination without physical sampling.
Corrected CPT total tip resistance qt = qc + u2(1 - a) accounts for unequal pore pressure end area effects; undrained shear strength is derived as su = (qt - σv0) / Nkt.
The Vane Shear Test (VST) measures peak and remolded undrained shear strength in soft clays; measured peak strength must be corrected using Bjerrum's factor μ(PI) to account for strain rate and anisotropy.
Geophysical seismic refraction uses Snell's Law and critical distance xc to compute layer depths z = (xc / 2) * sqrt((V2 - V1)/(V2 + V1)); MASW provides shear wave velocity Vs for dynamic shear modulus Gmax = ρ · Vs^2.
Last updated: July 2026
Overview of In Situ Geotechnical Testing
In situ field testing is essential in modern geotechnical practice because extracting truly "undisturbed" soil samples for laboratory testing is extremely difficult, particularly in loose sands, soft sensitive clays, and fractured rock masses. In situ tests measure soil and rock responses directly under existing geostatic stress conditions, avoiding sampling disturbance, stress relief, and moisture changes.
Cone Penetration Test (CPT and CPTU - ASTM D5778)
The Cone Penetration Test (CPT) and piezocone test (CPTU) involve pushing a standard 60 ∘ 60^\circ 6 0 ∘ apex angle, 10 cm 2 10\text{ cm}^2 10 cm 2 base area cone ( 35.7 mm 35.7\text{ mm} 35.7 mm diameter) into the ground at a constant rate of 20 mm/s 20\text{ mm/s} 20 mm/s ( 2.0 cm/s 2.0\text{ cm/s} 2.0 cm/s ).
Measured Parameters
Cone Tip Resistance ( q c q_c q c ): Total force on cone tip divided by tip area ( 10 cm 2 10\text{ cm}^2 10 cm 2 or 15 cm 2 15\text{ cm}^2 15 cm 2 ).
Sleeve Friction ( f s f_s f s ): Frictional force on the friction sleeve ( 150 cm 2 150\text{ cm}^2 150 cm 2 area) divided by sleeve surface area.
Pore Water Pressure ( u 2 u_2 u 2 ): Dynamic pore water pressure measured at the shoulder filter element (immediately behind the cone tip).
Key Calculated Derivatives
Friction Ratio ( R f R_f R f ): R f = ( f s q c ) × 100 % R_f = \left( \frac{f_s}{q_c} \right) \times 100\% R f = ( q c f s ) × 100%
High R f R_f R f ( > 3 – 5 % > 3\text{--}5\% > 3 – 5% ): Cohesive silts and clays. Low R f R_f R f ( < 1 % < 1\% < 1% ): Cohesionless sands and gravels.
Total Corrected Cone Tip Resistance ( q t q_t q t ): Corrects q c q_c q c for unequal pore pressure effects acting on the cone shoulder: q t = q c + u 2 ( 1 − a ) q_t = q_c + u_2 (1 - a) q t = q c + u 2 ( 1 − a )
Where a a a is the net cone area ratio (typically 0.70 – 0.85 0.70\text{--}0.85 0.70 – 0.85 , determined via laboratory calibration).
Undrained Shear Strength ( s u s_u s u ): s u = q t − σ v 0 N k t s_u = \frac{q_t - \sigma_{v0}}{N_{kt}} s u = N k t q t − σ v 0
Where σ v 0 \sigma_{v0} σ v 0 is total vertical overburden stress and N k t N_{kt} N k t is the empirical cone factor (typically N k t = 14 – 18 N_{kt} = 14\text{--}18 N k t = 14 – 18 for NC to LOC clays).
Soil Behavior Type Index ( I c I_c I c ): Proposed by Robertson (1990): I c = [ ( 3.47 − log Q t ) 2 + ( 1.22 + log F r ) 2 ] 0.5 I_c = \left[ (3.47 - \log Q_t)^2 + (1.22 + \log F_r)^2 \right]^{0.5} I c = [ ( 3.47 − lo g Q t ) 2 + ( 1.22 + lo g F r ) 2 ] 0.5
Where Q t = ( q t − σ v 0 ) / σ v 0 ′ Q_t = (q_t - \sigma_{v0})/\sigma'_{v0} Q t = ( q t − σ v 0 ) / σ v 0 ′ is normalized tip resistance and F r = [ f s / ( q t − σ v 0 ) ] × 100 % F_r = [f_s / (q_t - \sigma_{v0})] \times 100\% F r = [ f s / ( q t − σ v 0 )] × 100% . Soils with I c > 2.60 I_c > 2.60 I c > 2.60 exhibit fine-grained clay-like behavior; soils with I c < 2.05 I_c < 2.05 I c < 2.05 exhibit sand-like behavior.
Field Vane Shear Test (VST - ASTM D2573)
The Field Vane Shear Test provides in situ measurements of undrained shear strength ( s u s_u s u ) in soft to stiff saturated cohesive soils. A four-bladed rectangular vane ( H / D = 2.0 H/D = 2.0 H / D = 2.0 , typically D = 65 mm D = 65\text{ mm} D = 65 mm or 75 mm 75\text{ mm} 75 mm ) is pushed into the clay and rotated at 0.1 ∘ / sec 0.1^\circ / \text{sec} 0. 1 ∘ / sec until soil failure occurs.
Governing Strength Equations
For a standard rectangular vane with height H H H equal to twice the diameter D D D ( H = 2 D H = 2D H = 2 D ): s u , field = 6 T m a x 7 π D 3 s_{u,\text{field}} = \frac{6 T_{max}}{7 \pi D^3} s u , field = 7 π D 3 6 T ma x
Where T m a x T_{max} T ma x is the peak torque applied at failure. After measuring peak strength, the vane is rotated rapidly 10 10 10 full revolutions to completely remold the clay, and a second torque test measures remolded strength ( s u , remolded s_{u,\text{remolded}} s u , remolded ). Soil Sensitivity ( S t S_t S t ) is defined as: S t = s u , peak s u , remolded S_t = \frac{s_{u,\text{peak}}}{s_{u,\text{remolded}}} S t = s u , remolded s u , peak
Bjerrum Bjerrum Correction Factor ( μ \mu μ )
Field vane undrained shear strength overestimates actual field strength in design due to rate of loading and soil anisotropy. Bjerrum (1972) established that measured s u , field s_{u,\text{field}} s u , field must be corrected using factor μ \mu μ , which depends on the Plasticity Index ( P I PI P I ): s u , design = μ ⋅ s u , field s_{u,\text{design}} = \mu \cdot s_{u,\text{field}} s u , design = μ ⋅ s u , field μ = 1.7 − 0.54 log ( P I ) (or via Bjerrum chart; μ ≈ 1.0 for P I = 20 , μ ≈ 0.8 for P I = 50 ) \mu = 1.7 - 0.54 \log(PI) \quad \text{(or via Bjerrum chart; } \mu \approx 1.0 \text{ for } PI=20, \mu \approx 0.8 \text{ for } PI=50\text{)} μ = 1.7 − 0.54 lo g ( P I ) (or via Bjerrum chart; μ ≈ 1.0 for P I = 20 , μ ≈ 0.8 for P I = 50 )
Flat Plate Dilatometer Test (DMT - ASTM D6635)
The Marchetti Flat Dilatometer consists of a stainless steel blade ( 95 mm 95\text{ mm} 95 mm wide, 14 mm 14\text{ mm} 14 mm thick) with a expandable thin circular steel membrane ( 60 mm 60\text{ mm} 60 mm diameter) mounted on one face. The blade is pushed vertically into the ground. At target test depths, gas pressure expands the membrane:
A A A -pressure ( p 0 p_0 p 0 ): Pressure required to expand membrane flush with blade face ( 0.00 mm 0.00\text{ mm} 0.00 mm displacement).
B B B -pressure ( p 1 p_1 p 1 ): Pressure required to move membrane center 1.10 mm 1.10\text{ mm} 1.10 mm outward.
C C C -pressure ( p 2 p_2 p 2 ): Deflation pressure at which membrane returns to flush position (yields pore pressure u 0 u_0 u 0 ).
Key Index Parameters
Material Index ( I D I_D I D ): I D = p 1 − p 0 p 0 − u 0 I_D = \frac{p_1 - p_0}{p_0 - u_0} I D = p 0 − u 0 p 1 − p 0 (Classifies soil: I D < 0.6 I_D < 0.6 I D < 0.6 clay; 0.6 < I D < 1.8 0.6 < I_D < 1.8 0.6 < I D < 1.8 silt; I D > 1.8 I_D > 1.8 I D > 1.8 sand).
Horizontal Stress Index ( K D K_D K D ): K D = p 0 − u 0 σ v 0 ′ K_D = \frac{p_0 - u_0}{\sigma'_{v0}} K D = σ v 0 ′ p 0 − u 0 (Correlated to earth pressure coefficient K 0 K_0 K 0 and Overconsolidation Ratio O C R OCR OCR ).
Dilatometer Modulus ( M DMT M_{\text{DMT}} M DMT ): M DMT = 34.7 ( p 1 − p 0 ) M_{\text{DMT}} = 34.7 (p_1 - p_0) M DMT = 34.7 ( p 1 − p 0 ) (One-dimensional constrained modulus for settlement calculations).
Pressuremeter Test (PMT - ASTM D4719)
The Pressuremeter Test (Menard type) involves placing a cylindrical flexible probe inside a pre-bored hole and expanding it radially using hydraulic or pneumatic pressure. The test measures volume change ( Δ V \Delta V Δ V ) versus applied pressure ( p p p ).
Derived Soil Properties
Limit Pressure ( p L p_L p L ): Applied pressure at which the borehole volume doubles; used directly in Menard's ultimate bearing capacity equations.
Pressuremeter Modulus ( E PMT E_{\text{PMT}} E PMT ): Derived from the linear pseudo-elastic phase of the pressure-volume curve: E PMT = 2 ( 1 + ν ) ( V 0 + V m ) Δ p Δ V E_{\text{PMT}} = 2 (1 + \nu) (V_0 + V_m) \frac{\Delta p}{\Delta V} E PMT = 2 ( 1 + ν ) ( V 0 + V m ) Δ V Δ p Where ν \nu ν is Poisson's ratio, V 0 V_0 V 0 is initial cavity volume, and V m V_m V m is average cavity volume during the linear phase.
Geophysical Exploration Methods
Geophysical surveys provide continuous non-destructive cross-sections of subsurface stratigraphy.
Seismic Refraction Method
Seismic refraction measures arrival times of compressional P P P -waves generated by dynamic impacts. By applying Snell's Law to a two-layer subsurface where wave velocity increases with depth ( V 2 > V 1 V_2 > V_1 V 2 > V 1 ): sin θ c = V 1 V 2 \sin \theta_c = \frac{V_1}{V_2} sin θ c = V 2 V 1
The critical distance ( x c x_c x c ) on the travel-time plot—where direct wave and refracted wave arrivals coincide—yields layer depth z 1 z_1 z 1 : z 1 = x c 2 V 2 − V 1 V 2 + V 1 z_1 = \frac{x_c}{2} \sqrt{\frac{V_2 - V_1}{V_2 + V_1}} z 1 = 2 x c V 2 + V 1 V 2 − V 1
Multichannel Analysis of Surface Waves (MASW)
MASW records Rayleigh surface waves to construct shear wave velocity ( V s V_s V s ) profiles down to 30 m 30\text{ m} 30 m depth. V s , 30 V_{s,30} V s , 30 is used universally for seismic site classification (NEHRP Site Classes A through F). Small-strain dynamic shear modulus ( G m a x G_{max} G ma x ) is computed as: G m a x = ρ ⋅ V s 2 G_{max} = \rho \cdot V_s^2 G ma x = ρ ⋅ V s 2
Where ρ = γ / g \rho = \gamma / g ρ = γ / g is total soil mass density.
- Detailed Worked Numerical Example
- Problem Statement
A piezocone test (CPTU) is performed in a soft saturated marine clay layer at a depth of 10.0 m 10.0\text{ m} 10.0 m . The groundwater table is at the ground surface. The soil unit weight is γ s a t = 18.5 kN/m 3 \gamma_{sat} = 18.5\text{ kN/m}^3 γ s a t = 18.5 kN/m 3 .
The CPTU measurements at 10.0 m 10.0\text{ m} 10.0 m depth are:
Cone tip resistance q c = 1.45 MPa = 1450 kPa q_c = 1.45\text{ MPa} = 1450\text{ kPa} q c = 1.45 MPa = 1450 kPa
- Sleeve friction f s = 38.0 kPa f_s = 38.0\text{ kPa} f s = 38.0 kPa
- Penetration pore pressure u 2 = 320 kPa u_2 = 320\text{ kPa} u 2 = 320 kPa
- Net cone area ratio a = 0.75 a = 0.75 a = 0.75
- Empirical cone factor N k t = 15.0 N_{kt} = 15.0 N k t = 15.0
Concurrently, a Field Vane Shear Test (VST) was conducted at the same depth using a standard rectangular vane ( D = 75 mm D = 75\text{ mm} D = 75 mm , H = 150 mm H = 150\text{ mm} H = 150 mm ). The maximum measured torque was T m a x = 42.5 N ⋅ m T_{max} = 42.5\text{ N}\cdot\text{m} T ma x = 42.5 N ⋅ m . The soil Plasticity Index is P I = 40 % PI = 40\% P I = 40% , corresponding to a Bjerrum correction factor μ = 0.82 \mu = 0.82 μ = 0.82 .
Calculate:
Total corrected tip resistance q t q_t q t .
Total vertical overburden stress σ v 0 \sigma_{v0} σ v 0 and effective stress σ v 0 ′ \sigma'_{v0} σ v 0 ′ .
Undrained shear strength s u s_u s u from CPTU.
Field vane peak undrained shear strength s u , field s_{u,\text{field}} s u , field and design strength s u , design s_{u,\text{design}} s u , design .
Solution
Step 1: Calculate q t q_t q t from CPTU q t = q c + u 2 ( 1 − a ) = 1450 kPa + 320 kPa × ( 1 − 0.75 ) q_t = q_c + u_2(1 - a) = 1450\text{ kPa} + 320\text{ kPa} \times (1 - 0.75) q t = q c + u 2 ( 1 − a ) = 1450 kPa + 320 kPa × ( 1 − 0.75 ) q t = 1450 + 320 × 0.25 = 1450 + 80 = 1530 kPa q_t = 1450 + 320 \times 0.25 = 1450 + 80 = 1530\text{ kPa} q t = 1450 + 320 × 0.25 = 1450 + 80 = 1530 kPa
Step 2: Calculate overburden stresses at z = 10.0 m z = 10.0\text{ m} z = 10.0 m σ v 0 = γ s a t × z = 18.5 kN/m 3 × 10.0 m = 185.0 kPa \sigma_{v0} = \gamma_{sat} \times z = 18.5\text{ kN/m}^3 \times 10.0\text{ m} = 185.0\text{ kPa} σ v 0 = γ s a t × z = 18.5 kN/m 3 × 10.0 m = 185.0 kPa ν 0 = γ w × z = 9.81 kN/m 3 × 10.0 m = 98.1 kPa \nu_0 = \gamma_w \times z = 9.81\text{ kN/m}^3 \times 10.0\text{ m} = 98.1\text{ kPa} ν 0 = γ w × z = 9.81 kN/m 3 × 10.0 m = 98.1 kPa σ v 0 ′ = σ v 0 − u 0 = 185.0 − 98.1 = 86.9 kPa \sigma'_{v0} = \sigma_{v0} - u_0 = 185.0 - 98.1 = 86.9\text{ kPa} σ v 0 ′ = σ v 0 − u 0 = 185.0 − 98.1 = 86.9 kPa
Step 3: Calculate CPTU undrained shear strength s u s_u s u s u = q t − σ v 0 N k t = 1530 kPa − 185.0 kPa 15.0 = 1345 15.0 = 89.67 kPa s_u = \frac{q_t - \sigma_{v0}}{N_{kt}} = \frac{1530\text{ kPa} - 185.0\text{ kPa}}{15.0} = \frac{1345}{15.0} = 89.67\text{ kPa} s u = N k t q t − σ v 0 = 15.0 1530 kPa − 185.0 kPa = 15.0 1345 = 89.67 kPa
Step 4: Calculate VST strength Convert vane diameter D = 75 mm = 0.075 m D = 75\text{ mm} = 0.075\text{ m} D = 75 mm = 0.075 m . Torque T m a x = 42.5 N ⋅ m = 0.0425 kN ⋅ m T_{max} = 42.5\text{ N}\cdot\text{m} = 0.0425\text{ kN}\cdot\text{m} T ma x = 42.5 N ⋅ m = 0.0425 kN ⋅ m . s u , field = 6 T m a x 7 π D 3 = 6 × 0.0425 kN ⋅ m 7 π × ( 0.075 m ) 3 s_{u,\text{field}} = \frac{6 T_{max}}{7 \pi D^3} = \frac{6 \times 0.0425\text{ kN}\cdot\text{m}}{7 \pi \times (0.075\text{ m})^3} s u , field = 7 π D 3 6 T ma x = 7 π × ( 0.075 m ) 3 6 × 0.0425 kN ⋅ m s u , field = 0.255 7 × 3.14159 × 0.000421875 = 0.255 0.009278 = 27.48 kPa s_{u,\text{field}} = \frac{0.255}{7 \times 3.14159 \times 0.000421875} = \frac{0.255}{0.009278} = 27.48\text{ kPa} s u , field = 7 × 3.14159 × 0.000421875 0.255 = 0.009278 0.255 = 27.48 kPa
Applying Bjerrum correction μ = 0.82 \mu = 0.82 μ = 0.82 : s u , design = μ × s u , field = 0.82 × 27.48 kPa = 22.53 kPa s_{u,\text{design}} = \mu \times s_{u,\text{field}} = 0.82 \times 27.48\text{ kPa} = 22.53\text{ kPa} s u , design = μ × s u , field = 0.82 × 27.48 kPa = 22.53 kPa
Note: The field vane measures localized localized shear strength along vertical and horizontal failure planes, providing a conservative design strength when corrected for rate effects.