Study guide
4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment
PE Civil Geotechnical Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Site Characterization
1.1 Site Data Interpretation & Boring Plans 1.2 In Situ Testing & Field Exploration 1.3 Soil and Rock Classification Systems 1.4 Groundwater Characterization & Hydrogeology
2 Chapter 2: Soil Mechanics, Laboratory Testing, and Analysis
2.1 Weight-Volume Phase Relationships & Index Properties 2.2 Effective Stress & Pore Water Pressure Dynamics 2.3 Shear Strength Principles & Laboratory Testing 2.4 Permeability, Hydraulic Conductivity & Seepage Properties 2.5 Consolidation & Compressibility Analysis
3 Chapter 3: Construction Observation, Monitoring, QA/QC, and Safety
3.1 Earthwork Quality Control & Compaction Verification 3.2 Geotechnical Instrumentation & Field Monitoring 3.3 Trenching, Excavation Safety & OSHA Shoring Requirements 3.4 Erosion, Scour Protection & Slope Protection During Construction
4 Chapter 4: Earthquake Engineering and Dynamic Loads
4.1 Seismic Site Characterization & Ground Motion Hazards 4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment 4.3 Dynamic Soil Properties & Ground Response Analysis 4.4 Pseudostatic Analysis & Seismic Geotechnical Design
5 Chapter 5: Earth Structures, Ground Improvement, and Pavement
5.1 Slope Stability Analysis & Limit Equilibrium Methods 5.2 Embankments, Earth Dams & Levee Geotechnics 5.3 Ground Improvement Techniques & Design 5.4 Geosynthetics in Geotechnical Engineering 5.5 Flexible & Rigid Pavement Subgrades & Buried Utilities 5.6 Landfills, Caps & Containment Systems
6 Chapter 6: Groundwater and Seepage
6.1 Dewatering System Design & Well Drawdown 6.2 Flow Nets & Two-Dimensional Seepage Analysis 6.3 Uplift Pressure, Piping & Heave Safety 6.4 Subsurface Drainage Systems & Filter Criteria
7 Chapter 7: Problematic Soil and Rock Conditions
7.1 Expansive & Collapsible Soil Engineering 7.2 Organic Soils, Sensitive Clays & Soft Marine Deposits 7.3 Corrosive, Frost-Susceptible & Degradable Formations 7.4 Karst Topography, Rock Slopes & Rockfall Hazards
8 Chapter 8: Retaining Structures
8.1 Lateral Earth Pressure Theories 8.2 Rigid Retaining Wall Design 8.3 Flexible Retaining Walls & Sheet Pile Bulkheads 8.4 Temporary Support of Excavations 8.5 Mechanically Stabilized Earth (MSE) Walls & Soil Nail Structures 8.6 Cofferdams, Underpinning & Adjacent Infrastructure Effects
9 Chapter 9: Shallow Foundations
9.1 Ultimate & Allowable Bearing Capacity Theories 9.2 Effective Footing Area, Eccentricity & Combined Footings 9.3 Induced Stress Distribution & Immediate Elastic Settlement 9.4 Consolidation Settlement & Mat/Raft Foundation Design
10 Chapter 10: Deep Foundations
10.1 Driven Pile Axial Capacity & Settlement 10.2 Drilled Shaft Axial Design & Construction Methods 10.3 Lateral Load Behavior of Deep Foundations 10.4 Pile Group Dynamics, Efficiency & Downdrag 10.5 Dynamic Load Testing & Pile Integrity Evaluation
4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment
Key Takeaways Explain This Topic AI
Liquefaction occurs in saturated cohesionless soils when cyclic earthquake shearing induces pore water pressure buildup equal to initial effective overburden stress (ru = 1.0), reducing effective stress and shear strength to near zero.
Liquefaction susceptibility for fine-grained soils is assessed using Plasticity Index (PI < 12) and Liquid Limit (LL < 37) criteria per Bray & Sancio / Boulanger & Idriss.
The Simplified Procedure compares the earthquake-induced Cyclic Stress Ratio (CSR) against the soil's Cyclic Resistance Ratio (CRR7.5), adjusted by Magnitude Scaling Factors (MSF) and overburden corrections (K_sigma).
Post-liquefaction consequences include volumetric reconsolidation settlement, loss of shear strength to a residual value (sr), and lateral spreading displacement.
Ground improvement methods (e.g., stone columns, compaction grouting, deep soil mixing) mitigate liquefaction through densification, reinforcement, stress redirection, or drainage.
Last updated: July 2026
- 4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment
- 1. Physics of Soil Liquefaction
Soil liquefaction is one of the most destructive geotechnical hazards caused by strong earthquake ground shaking. Under undrained cyclic shear loading, loose to medium-dense saturated cohesionless soils (sands, non-plastic silts, and gravelly sands) tend to contract. Because pore water cannot drain rapidly during brief earthquake shaking, contractive volumetric tendencies transfer stress from the soil skeleton to the pore fluid, generating excess pore water pressure ( Δ u \Delta u Δ u ) .
As excess pore pressure accumulates, the excess pore pressure ratio r u r_u r u approaches unity: r u = Δ u σ v o ′ → 1.0 r_u = \frac{\Delta u}{\sigma'_{vo}} \rightarrow 1.0 r u = σ v o ′ Δ u → 1.0
According to Terzaghi's effective stress principle ( σ ′ = σ − u \sigma' = \sigma - u σ ′ = σ − u ), when Δ u ≈ σ v o ′ \Delta u \approx \sigma'_{vo} Δ u ≈ σ v o ′ , the effective stress drops to zero ( σ ′ → 0 \sigma' \to 0 σ ′ → 0 ). Consequently, frictional shear strength ( τ = σ ′ tan ϕ ′ \tau = \sigma' \tan\phi' τ = σ ′ tan ϕ ′ ) vanishes, causing the soil deposit to transform transiently into a dense fluid suspension. Two primary phenomena result:
Flow Liquefaction: Occurs in loose soils where static shear stresses (such as on slopes or under footing edges) exceed the residual strength of the liquefied soil ( s r s_r s r ), triggering catastrophic, unlimited flow slides.
Cyclic Mobility: Occurs in medium-dense soils under level or gently sloping ground where cyclic stress reversals produce large incremental shear deformations, but static equilibrium is maintained due to strain-hardening upon dilation at larger strains.
2. Liquefaction Susceptibility Criteria
Not all soils are susceptible to liquefaction. Geotechnical screening evaluates grain size distribution, density, groundwater depth, and soil plasticity:
Cohesionless Soils: Clean sands ( F C < 5 % FC < 5\% FC < 5% ), silty sands, and non-plastic silts with high relative density ( D r > 75 % D_r > 75\% D r > 75% ) or high blow counts ( N 1 , 60 c s ≥ 30 N_{1,60cs} \ge 30 N 1 , 60 cs ≥ 30 ) are non-liquefiable under typical design earthquakes.
Fine-Grained Soil Susceptibility (Bray & Sancio 2006 / Boulanger & Idriss 2006):
Susceptible to Liquefaction (Sand-like Behavior): Plasticity Index P I < 12 PI < 12 P I < 12 , Liquid Limit L L < 37 LL < 37 LL < 37 , and in-situ water content ratio w c / L L > 0.85 w_c / LL > 0.85 w c / LL > 0.85 .
Moderately Susceptible: 12 ≤ P I ≤ 18 12 \le PI \le 18 12 ≤ P I ≤ 18 and L L < 45 LL < 45 LL < 45 .
Clay-like Cyclic Softening (Non-Liquefiable by Classical Sand Rules): P I > 18 PI > 18 P I > 18 . These soils undergo cyclic softening rather than classical liquefaction and must be evaluated using fine-grained dynamic strength reduction procedures.
3. Simplified Triggering Procedure (Seed & Idriss Methodology)
The industry standard for evaluating liquefaction triggering is the Simplified Procedure (Seed & Idriss 1971; Youd et al. 2001; Boulanger & Idriss 2014). It involves comparing the seismic demand ( Cyclic Stress Ratio, C S R CSR CSR ) against the soil capacity ( Cyclic Resistance Ratio, C R R CRR CRR ).
Step A: Compute Seismic Demand ( C S R CSR CSR )
The average cyclic shear stress ratio induced by an earthquake at depth z z z is calculated as: C S R = 0.65 ⋅ ( a m a x g ) ⋅ ( σ v o σ v o ′ ) ⋅ r d CSR = 0.65 \cdot \left(\frac{a_{max}}{g}\right) \cdot \left(\frac{\sigma_{vo}}{\sigma'_{vo}}\right) \cdot r_d CSR = 0.65 ⋅ ( g a ma x ) ⋅ ( σ v o ′ σ v o ) ⋅ r d
where:
a m a x a_{max} a ma x = peak horizontal ground surface acceleration.
g g g = acceleration of gravity ( 9.81 m/s 2 9.81\text{ m/s}^2 9.81 m/s 2 or 32.2 ft/s 2 32.2\text{ ft/s}^2 32.2 ft/s 2 ).
σ v o \sigma_{vo} σ v o = total vertical overburden stress at depth z z z .
σ v o ′ \sigma'_{vo} σ v o ′ = effective vertical overburden stress at depth z z z .
r d r_d r d = stress reduction coefficient accounting for soil column flexibility (Boulanger & Idriss 2014): r d = exp ( − 1.012 − 0.00518 z + 0.0024 z 1.5 + ( 0.0158 + 0.0006 z ) M w ) r_d = \exp\left( -1.012 - 0.00518 z + 0.0024 z^{1.5} + (0.0158 + 0.0006 z) M_w \right) r d = exp ( − 1.012 − 0.00518 z + 0.0024 z 1.5 + ( 0.0158 + 0.0006 z ) M w ) Or for simplified hand calculations ( z ≤ 9.15 m z \le 9.15\text{ m} z ≤ 9.15 m / 30 ft 30\text{ ft} 30 ft ): r d ≈ 1.0 − 0.00765 z ( z in meters ) r_d \approx 1.0 - 0.00765 z \quad (z \text{ in meters}) r d ≈ 1.0 − 0.00765 z ( z in meters )
Step B: Compute Soil Capacity ( C R R 7.5 CRR_{7.5} CR R 7.5 )
Field penetration resistance is first corrected to an equivalent clean-sand blow count ( N 1 , 60 c s N_{1,60cs} N 1 , 60 cs ): N 1 , 60 = N 60 ⋅ C N ⋅ C B ⋅ C R ⋅ C S N_{1,60} = N_{60} \cdot C_N \cdot C_B \cdot C_R \cdot C_S N 1 , 60 = N 60 ⋅ C N ⋅ C B ⋅ C R ⋅ C S
where C N = P a σ v o ′ ≤ 1.7 C_N = \sqrt{\frac{P_a}{\sigma'_{vo}}} \le 1.7 C N = σ v o ′ P a ≤ 1.7 is the overburden correction factor ( P a = 100 kPa ≈ 1 atm P_a = 100\text{ kPa} \approx 1\text{ atm} P a = 100 kPa ≈ 1 atm ).
The fine-content correction yields N 1 , 60 c s N_{1,60cs} N 1 , 60 cs : N 1 , 60 c s = N 1 , 60 + Δ N 1 , 60 N_{1,60cs} = N_{1,60} + \Delta N_{1,60} N 1 , 60 cs = N 1 , 60 + Δ N 1 , 60 Δ N 1 , 60 = exp ( 1.63 + 9.7 F C + 0.01 − ( 15.7 F C + 0.01 ) 2 ) \Delta N_{1,60} = \exp\left( 1.63 + \frac{9.7}{FC + 0.01} - \left(\frac{15.7}{FC + 0.01}\right)^2 \right) Δ N 1 , 60 = exp ( 1.63 + FC + 0.01 9.7 − ( FC + 0.01 15.7 ) 2 )
For an M w = 7.5 M_w = 7.5 M w = 7.5 earthquake and effective overburden stress σ v o ′ = 1 atm \sigma'_{vo} = 1\text{ atm} σ v o ′ = 1 atm , C R R M 7.5 , 1 a t m CRR_{M7.5, 1atm} CR R M 7.5 , 1 a t m is estimated per Boulanger & Idriss (2014): C R R 7.5 = exp ( N 1 , 60 c s 14.1 + ( N 1 , 60 c s 126 ) 2 − ( N 1 , 60 c s 23.6 ) 3 + ( N 1 , 60 c s 25.4 ) 4 − 3 ) CRR_{7.5} = \exp\left( \frac{N_{1,60cs}}{14.1} + \left(\frac{N_{1,60cs}}{126}\right)^2 - \left(\frac{N_{1,60cs}}{23.6}\right)^3 + \left(\frac{N_{1,60cs}}{25.4}\right)^4 - 3 \right) CR R 7.5 = exp ( 14.1 N 1 , 60 cs + ( 126 N 1 , 60 cs ) 2 − ( 23.6 N 1 , 60 cs ) 3 + ( 25.4 N 1 , 60 cs ) 4 − 3 )
Step C: Compute Factor of Safety ( F S l i q FS_{liq} F S l i q )
To adjust C R R 7.5 CRR_{7.5} CR R 7.5 for different earthquake magnitudes ( M w M_w M w ) and overburden stresses ( σ v o ′ ≠ 1 atm \sigma'_{vo} \neq 1\text{ atm} σ v o ′ = 1 atm ): F S l i q = C R R 7.5 ⋅ M S F ⋅ K σ C S R FS_{liq} = \frac{CRR_{7.5} \cdot MSF \cdot K\sigma}{CSR} F S l i q = CSR CR R 7.5 ⋅ MSF ⋅ K σ
where:
Magnitude Scaling Factor ( M S F MSF MSF ): Corrects for duration of shaking relative to M w = 7.5 M_w = 7.5 M w = 7.5 : M S F = 6.9 ⋅ exp ( − M w 4 ) − 0.058 ≤ 1.8 MSF = 6.9 \cdot \exp\left(-\frac{M_w}{4}\right) - 0.058 \le 1.8 MSF = 6.9 ⋅ exp ( − 4 M w ) − 0.058 ≤ 1.8
Overburden Correction Factor ( K σ K_\sigma K σ ): Accounts for non-linear reduction in cyclic strength ratio at high effective stresses: K σ = 1 − C σ ln ( σ v o ′ P a ) ≤ 1.1 K\sigma = 1 - C\sigma \ln\left(\frac{\sigma'_{vo}}{P_a}\right) \le 1.1 K σ = 1 − C σ ln ( P a σ v o ′ ) ≤ 1.1 where C σ = 1 18.9 − 2.55 N 1 , 60 c s ≤ 0.3 C_\sigma = \frac{1}{18.9 - 2.55 \sqrt{N_{1,60cs}}} \le 0.3 C σ = 18.9 − 2.55 N 1 , 60 cs 1 ≤ 0.3 .
A soil layer is predicted to liquefy if F S l i q < 1.0 FS_{liq} < 1.0 F S l i q < 1.0 (or F S l i q < 1.2 − 1.5 FS_{liq} < 1.2 - 1.5 F S l i q < 1.2 − 1.5 per engineering design standards).
4. Post-Liquefaction Assessment: Settlement & Lateral Spreading
When liquefaction is triggered ( F S l i q < 1.0 FS_{liq} < 1.0 F S l i q < 1.0 ), geotechnical engineers must quantify post-liquefaction deformations:
Post-Liquefaction Volumetric Settlement (Reconsolidation):
Excess pore pressures dissipate upward after shaking, causing volumetric contraction strain ( ε v \varepsilon_v ε v ) in liquefied layers.
ε v \varepsilon_v ε v is evaluated as a function of F S l i q FS_{liq} F S l i q and N 1 , 60 c s N_{1,60cs} N 1 , 60 cs (Ishihara & Yoshimine 1992; Zhang et al. 2002).
Total ground surface settlement Δ S \Delta S Δ S is the integral of volumetric strain across layer thickness H H H : Δ S = ∑ i = 1 m ε v , i ⋅ Δ z i \Delta S = \sum_{i=1}^{m} \varepsilon_{v,i} \cdot \Delta z_i Δ S = i = 1 ∑ m ε v , i ⋅ Δ z i
Residual Shear Strength ( s r s_r s r ):
Liquefied soil retains a small residual undrained shear strength s r s_r s r due to soil fabric jamming and friction at large strains.
s r s_r s r (or normalized ratio s r / σ v o ′ s_r / \sigma'_{vo} s r / σ v o ′ ) is estimated from empirical SPT correlations (Olson & Stark 2002; Idriss & Boulanger 2008): s r = P a ⋅ exp ( N 1 , 60 c s 16 + ( N 1 , 60 c s 16 ) 3 − 3.0 ) or s r σ v o ′ = 0.02 − 0.12 s_r = P_a \cdot \exp\left( \frac{N_{1,60cs}}{16} + \left(\frac{N_{1,60cs}}{16}\right)^3 - 3.0 \right) \quad \text{or} \quad \frac{s_r}{\sigma'_{vo}} = 0.02 - 0.12 s r = P a ⋅ exp ( 16 N 1 , 60 cs + ( 16 N 1 , 60 cs ) 3 − 3.0 ) or σ v o ′ s r = 0.02 − 0.12
Lateral Spreading Displacement:
Gentle slopes ( 0.1 % − 5 % 0.1\% - 5\% 0.1% − 5% ) or free-face margins (riverbanks, seawalls) undergo lateral movement driven by static gravity stresses operating on liquefied soil.
Lateral Displacement Index ( L D I LDI L D I ): Calculated by integrating maximum shear strains ( γ m a x \gamma_{max} γ ma x ) over depth: L D I = ∫ 0 z m a x γ m a x ⋅ d z LDI = \int_{0}^{z_{max}} \gamma_{max} \cdot dz L D I = ∫ 0 z ma x γ ma x ⋅ d z
Empirical models (Youd, Hansen, & Bartlett 2002 Multi-Linear Regression) predict horizontal displacement ( D H D_H D H ) as a function of slope steepness ( W % W\% W % or S % S\% S % ), earthquake magnitude ( M w M_w M w ), distance to source ( R R R ), and cumulative liquefied thickness ( T 15 T_{15} T 15 ).
5. Liquefaction Mitigation Strategies
Ground Improvement Technique Primary Mechanism Applicability / Limitations
Vibro-Compaction / Vibro-Replacement Densification via mechanical vibration; gravel stone column reinforcement. Highly effective in clean to moderately silty sands ( F C < 15 % FC < 15\% FC < 15% ).
Dynamic Compaction Heavy weight drops ( 10 − 30 tonnes 10-30\text{ tonnes} 10 − 30 tonnes ) from heights ( 10 − 30 m 10-30\text{ m} 10 − 30 m ) densifying deep deposits. Effective for coarse granular soils; limited near sensitive adjacent structures.
Compaction Grouting Injection of low-slump mortar bulb expanding soil and increasing horizontal stress. Excellent for underpinning existing foundations in loose sand.
Deep Soil Mixing (DSM) / Jet Grouting In-situ cementitious mixing to create soil-cement grid columns or walls. Encapsulates liquefiable soils, cutting off strain development.
Subsurface Drains (Prefabricated Vertical Drains / Gravel Drains) Rapid dissipation of excess pore water pressures during shaking ( r u < 0.6 r_u < 0.6 r u < 0.6 ). Prevents r u r_u r u from reaching 1.0 without high densification energy.
6. Comprehensive Step-by-Step Worked Example
Problem Statement:
A level site proposed for a commercial building has a saturated clean sand layer ( F C = 3 % FC = 3\% FC = 3% ) located at a depth of z = 6.0 m z = 6.0\text{ m} z = 6.0 m .
- Water table depth: z w = 1.5 m z_{w} = 1.5\text{ m} z w = 1.5 m
- Total unit weight above water table: γ m = 18.0 kN/m 3 \gamma_{m} = 18.0\text{ kN/m}^3 γ m = 18.0 kN/m 3
Saturated unit weight below water table: γ s a t = 19.5 kN/m 3 \gamma_{sat} = 19.5\text{ kN/m}^3 γ s a t = 19.5 kN/m 3
Measured field blow count at z = 6.0 m z = 6.0\text{ m} z = 6.0 m : N 60 = 10 N_{60} = 10 N 60 = 10
Design Earthquake: Magnitude M w = 7.5 M_w = 7.5 M w = 7.5 , Peak Ground Acceleration a m a x = 0.30 g a_{max} = 0.30g a ma x = 0.30 g
Overburden correction exponent C N = 1.15 C_N = 1.15 C N = 1.15 , hammer efficiency ratio C B C R C S = 1.0 C_B C_R C_S = 1.0 C B C R C S = 1.0 .
Simplified stress reduction coefficient at z = 6 m z = 6\text{ m} z = 6 m : r d = 1.0 − 0.00765 ( 6.0 ) = 0.954 r_d = 1.0 - 0.00765(6.0) = 0.954 r d = 1.0 − 0.00765 ( 6.0 ) = 0.954 .
Volumetric strain correlation for this N 1 , 60 c s N_{1,60cs} N 1 , 60 cs and C S R CSR CSR : ε v = 2.5 % \varepsilon_v = 2.5\% ε v = 2.5% .
Thickness of liquefied sand layer: H = 4.0 m H = 4.0\text{ m} H = 4.0 m .
Calculate:
Initial total stress σ v o \sigma_{vo} σ v o and effective stress σ v o ′ \sigma'_{vo} σ v o ′ at z = 6.0 m z = 6.0\text{ m} z = 6.0 m .
The Cyclic Stress Ratio ( C S R CSR CSR ).
The normalized clean sand blow count ( N 1 , 60 c s N_{1,60cs} N 1 , 60 cs ) and Cyclic Resistance Ratio ( C R R 7.5 CRR_{7.5} CR R 7.5 ).
Factor of Safety against Liquefaction ( F S l i q FS_{liq} F S l i q ).
Estimated post-liquefaction reconsolidation settlement ( Δ S \Delta S Δ S ).
Solution:
Step 1: Overburden Stresses at z = 6.0 m z = 6.0\text{ m} z = 6.0 m
Total overburden stress: σ v o = ( 1.5 m × 18.0 kN/m 3 ) + ( 4.5 m × 19.5 kN/m 3 ) = 27.0 + 87.75 = 114.75 kPa \sigma_{vo} = (1.5\text{ m} \times 18.0\text{ kN/m}^3) + (4.5\text{ m} \times 19.5\text{ kN/m}^3) = 27.0 + 87.75 = \mathbf{114.75\text{ kPa}} σ v o = ( 1.5 m × 18.0 kN/m 3 ) + ( 4.5 m × 19.5 kN/m 3 ) = 27.0 + 87.75 = 114.75 kPa
Pore water pressure: u o = 4.5 m × 9.81 kN/m 3 = 44.15 kPa u_o = 4.5\text{ m} \times 9.81\text{ kN/m}^3 = \mathbf{44.15\text{ kPa}} u o = 4.5 m × 9.81 kN/m 3 = 44.15 kPa
Initial effective stress: σ v o ′ = σ v o − u o = 114.75 − 44.15 = 70.60 kPa \sigma'_{vo} = \sigma_{vo} - u_o = 114.75 - 44.15 = \mathbf{70.60\text{ kPa}} σ v o ′ = σ v o − u o = 114.75 − 44.15 = 70.60 kPa
Step 2: Compute Cyclic Stress Ratio ( C S R CSR CSR ) C S R = 0.65 × ( a m a x g ) × ( σ v o σ v o ′ ) × r d CSR = 0.65 \times \left(\frac{a_{max}}{g}\right) \times \left(\frac{\sigma_{vo}}{\sigma'_{vo}}\right) \times r_d CSR = 0.65 × ( g a ma x ) × ( σ v o ′ σ v o ) × r d C S R = 0.65 × 0.30 × ( 114.75 70.60 ) × 0.954 = 0.195 × 1.6253 × 0.954 = 0.3023 CSR = 0.65 \times 0.30 \times \left(\frac{114.75}{70.60}\right) \times 0.954 = 0.195 \times 1.6253 \times 0.954 = \mathbf{0.3023} CSR = 0.65 × 0.30 × ( 70.60 114.75 ) × 0.954 = 0.195 × 1.6253 × 0.954 = 0.3023
Step 3: Compute N 1 , 60 c s N_{1,60cs} N 1 , 60 cs and C R R 7.5 CRR_{7.5} CR R 7.5
Normalized blow count: N 1 , 60 = N 60 × C N = 10 × 1.15 = 11.5 N_{1,60} = N_{60} \times C_N = 10 \times 1.15 = 11.5 N 1 , 60 = N 60 × C N = 10 × 1.15 = 11.5 Since fine content F C = 3 % < 5 % FC = 3\% < 5\% FC = 3% < 5% , fine content correction Δ N 1 , 60 = 0 \Delta N_{1,60} = 0 Δ N 1 , 60 = 0 , so N 1 , 60 c s = 11.5 N_{1,60cs} = 11.5 N 1 , 60 cs = 11.5 .
Cyclic Resistance Ratio ( C R R 7.5 CRR_{7.5} CR R 7.5 ) using Boulanger & Idriss formula for N 1 , 60 c s = 11.5 N_{1,60cs} = 11.5 N 1 , 60 cs = 11.5 : C R R 7.5 = exp ( 11.5 14.1 + ( 11.5 126 ) 2 − ( 11.5 23.6 ) 3 + ( 11.5 25.4 ) 4 − 3 ) CRR_{7.5} = \exp\left( \frac{11.5}{14.1} + \left(\frac{11.5}{126}\right)^2 - \left(\frac{11.5}{23.6}\right)^3 + \left(\frac{11.5}{25.4}\right)^4 - 3 \right) CR R 7.5 = exp ( 14.1 11.5 + ( 126 11.5 ) 2 − ( 23.6 11.5 ) 3 + ( 25.4 11.5 ) 4 − 3 ) C R R 7.5 = exp ( 0.8156 + 0.0083 − 0.1158 + 0.0421 − 3.0 ) = exp ( − 2.2498 ) = 0.1054 CRR_{7.5} = \exp\left( 0.8156 + 0.0083 - 0.1158 + 0.0421 - 3.0 \right) = \exp(-2.2498) = \mathbf{0.1054} CR R 7.5 = exp ( 0.8156 + 0.0083 − 0.1158 + 0.0421 − 3.0 ) = exp ( − 2.2498 ) = 0.1054
Step 4: Factor of Safety against Liquefaction ( F S l i q FS_{liq} F S l i q )
Since M w = 7.5 M_w = 7.5 M w = 7.5 , M S F = 1.0 MSF = 1.0 MSF = 1.0 . For σ v o ′ = 70.6 kPa \sigma'_{vo} = 70.6\text{ kPa} σ v o ′ = 70.6 kPa , K σ ≈ 1.05 K_\sigma \approx 1.05 K σ ≈ 1.05 . F S l i q = C R R 7.5 × M S F × K σ C S R = 0.1054 × 1.0 × 1.05 0.3023 = 0.1107 0.3023 = 0.366 FS_{liq} = \frac{CRR_{7.5} \times MSF \times K\sigma}{CSR} = \frac{0.1054 \times 1.0 \times 1.05}{0.3023} = \frac{0.1107}{0.3023} = \mathbf{0.366} F S l i q = CSR CR R 7.5 × MSF × K σ = 0.3023 0.1054 × 1.0 × 1.05 = 0.3023 0.1107 = 0.366
Since F S l i q = 0.366 ≪ 1.0 FS_{liq} = 0.366 \ll 1.0 F S l i q = 0.366 ≪ 1.0 , liquefaction is triggered in this layer .
Step 5: Post-Liquefaction Settlement ( Δ S \Delta S Δ S )
With volumetric strain ε v = 2.5 % \varepsilon_v = 2.5\% ε v = 2.5% across H = 4.0 m H = 4.0\text{ m} H = 4.0 m ( 4000 mm 4000\text{ mm} 4000 mm ): Δ S = ε v × H = 0.025 × 4000 mm = 100 mm ( 3.94 inches ) \mathbf{\Delta S} = \varepsilon_v \times H = 0.025 \times 4000\text{ mm} = \mathbf{100\text{ mm}} \quad (3.94\text{ inches}) ΔS = ε v × H = 0.025 × 4000 mm = 100 mm ( 3.94 inches )