Study guide
9.2 Effective Footing Area, Eccentricity & Combined Footings
PE Civil Geotechnical Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Site Characterization
1.1 Site Data Interpretation & Boring Plans 1.2 In Situ Testing & Field Exploration 1.3 Soil and Rock Classification Systems 1.4 Groundwater Characterization & Hydrogeology
2 Chapter 2: Soil Mechanics, Laboratory Testing, and Analysis
2.1 Weight-Volume Phase Relationships & Index Properties 2.2 Effective Stress & Pore Water Pressure Dynamics 2.3 Shear Strength Principles & Laboratory Testing 2.4 Permeability, Hydraulic Conductivity & Seepage Properties 2.5 Consolidation & Compressibility Analysis
3 Chapter 3: Construction Observation, Monitoring, QA/QC, and Safety
3.1 Earthwork Quality Control & Compaction Verification 3.2 Geotechnical Instrumentation & Field Monitoring 3.3 Trenching, Excavation Safety & OSHA Shoring Requirements 3.4 Erosion, Scour Protection & Slope Protection During Construction
4 Chapter 4: Earthquake Engineering and Dynamic Loads
4.1 Seismic Site Characterization & Ground Motion Hazards 4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment 4.3 Dynamic Soil Properties & Ground Response Analysis 4.4 Pseudostatic Analysis & Seismic Geotechnical Design
5 Chapter 5: Earth Structures, Ground Improvement, and Pavement
5.1 Slope Stability Analysis & Limit Equilibrium Methods 5.2 Embankments, Earth Dams & Levee Geotechnics 5.3 Ground Improvement Techniques & Design 5.4 Geosynthetics in Geotechnical Engineering 5.5 Flexible & Rigid Pavement Subgrades & Buried Utilities 5.6 Landfills, Caps & Containment Systems
6 Chapter 6: Groundwater and Seepage
6.1 Dewatering System Design & Well Drawdown 6.2 Flow Nets & Two-Dimensional Seepage Analysis 6.3 Uplift Pressure, Piping & Heave Safety 6.4 Subsurface Drainage Systems & Filter Criteria
7 Chapter 7: Problematic Soil and Rock Conditions
7.1 Expansive & Collapsible Soil Engineering 7.2 Organic Soils, Sensitive Clays & Soft Marine Deposits 7.3 Corrosive, Frost-Susceptible & Degradable Formations 7.4 Karst Topography, Rock Slopes & Rockfall Hazards
8 Chapter 8: Retaining Structures
8.1 Lateral Earth Pressure Theories 8.2 Rigid Retaining Wall Design 8.3 Flexible Retaining Walls & Sheet Pile Bulkheads 8.4 Temporary Support of Excavations 8.5 Mechanically Stabilized Earth (MSE) Walls & Soil Nail Structures 8.6 Cofferdams, Underpinning & Adjacent Infrastructure Effects
9 Chapter 9: Shallow Foundations
9.1 Ultimate & Allowable Bearing Capacity Theories 9.2 Effective Footing Area, Eccentricity & Combined Footings 9.3 Induced Stress Distribution & Immediate Elastic Settlement 9.4 Consolidation Settlement & Mat/Raft Foundation Design
10 Chapter 10: Deep Foundations
10.1 Driven Pile Axial Capacity & Settlement 10.2 Drilled Shaft Axial Design & Construction Methods 10.3 Lateral Load Behavior of Deep Foundations 10.4 Pile Group Dynamics, Efficiency & Downdrag 10.5 Dynamic Load Testing & Pile Integrity Evaluation
9.2 Effective Footing Area, Eccentricity & Combined Footings
Key Takeaways Explain This Topic AI
Load eccentricity (e = M / P) shifts the vertical pressure distribution beneath footings, creating non-uniform contact stress and potential tension detachment if e > B / 6.
Meyerhof's effective area method reduces nominal footing dimensions to B' = B - 2e_B and L' = L - 2e_L, using B' and L' for both ultimate bearing capacity equations and allowable load calculations.
One-way eccentricity within the middle third (e <= B / 6) maintains full base contact with trapezoidal soil pressure, where q_max,min = (P / BL) * (1 +/- 6e / B).
Combined footings (rectangular or trapezoidal) unify two or more column loads onto a single foundation, matching the centroid of the footing footprint with the resultant column force to prevent non-uniform settlement.
Strap (cantilever) footings connect an exterior column footing subject to spatial edge constraints to an interior footing via a rigid beam, transferring eccentric overturning moments without causing base tilt.
Last updated: July 2026
Foundations Subjected to Eccentric Loading
Eccentric loads arise when structural columns transfer vertical downward forces P P P accompanied by bending moments M M M caused by wind, seismic shear, or lateral soil pressures ( e = M / P e = M / P e = M / P ). In spread footings, eccentricity redistributes soil contact pressure non-uniformly across the base.
Contact Stress Distribution & Middle-Third Rule (One-Way Eccentricity)
For a rectangular footing of width B B B and length L L L subjected to a load P P P with eccentricity e = M / P e = M / P e = M / P along axis B B B : Soil Stress Profiles Under Eccentric Load P
- e <= B/6 (Trapezoidal) e = B/6 (Triangular) e > B/6 (Base Detachment)
- P P P
- │ │ │
- ┌─────┴─────┐ ┌─────┴─────┐ ┌─────┴─────┐
- └─────┬─────┘ └─────┬─────┘ └─────┬─────┘
- ▲▲▲▲▲▲▲▲▲▲▲▲▲ ▲▲▲▲▲▲▲▲▲▲▲▲▲ ▲▲▲▲▲▲▲
- │ │ │ │ │ │
- q_min q_max q_min=0 q_max q_min=0 q_max
- ◄─── L_eff ──►
- 1. Eccentricity Within the Middle Third ( e ≤ B / 6 e \le B/6 e ≤ B /6 )
The entire base remains in compression with a trapezoidal contact stress distribution: q m a x = P B L ( 1 + 6 e B ) q_{max} = \frac{P}{B L} \left( 1 + \frac{6 e}{B} \right) q ma x = B L P ( 1 + B 6 e ) q m i n = P B L ( 1 − 6 e B ) q_{min} = \frac{P}{B L} \left( 1 - \frac{6 e}{B} \right) q min = B L P ( 1 − B 6 e )
Where q m i n ≥ 0 q_{min} \ge 0 q min ≥ 0 .
2. Eccentricity at the Limit of Middle Third ( e = B / 6 e = B/6 e = B /6 )
The stress distribution becomes strictly triangular across the entire footprint: q m i n = 0 , q m a x = 2 P B L q_{min} = 0, \quad q_{max} = \frac{2 P}{B L} q min = 0 , q ma x = B L 2 P
3. Eccentricity Exceeding Middle Third ( e > B / 6 e > B/6 e > B /6 )
Soil cannot sustain tension. Tensile separation (lift-off) occurs along the heel of the footing. The effective contact length reduces to L e f f = 3 ( B 2 − e ) L_{eff} = 3 \left(\frac{B}{2} - e\right) L e ff = 3 ( 2 B − e ) , and maximum compressive edge stress becomes: q m a x = 2 P 3 L ( B 2 − e ) q_{max} = \frac{2 P}{3 L \left(\frac{B}{2} - e\right)} q ma x = 3 L ( 2 B − e ) 2 P q m i n = 0 across detached zone of length [ B − 3 ( B 2 − e ) ] q_{min} = 0 \text{ across detached zone of length } \left[ B - 3\left(\frac{B}{2} - e\right) \right] q min = 0 across detached zone of length [ B − 3 ( 2 B − e ) ]
Meyerhof's Effective Area Concept
Meyerhof (1953) established that an eccentrically loaded footing can be evaluated as an equivalent concentrically loaded footing with reduced effective dimensions ( B ′ , L ′ B', L' B ′ , L ′ ): B ′ = B − 2 e B B' = B - 2 e_B B ′ = B − 2 e B L ′ = L − 2 e L L' = L - 2 e_L L ′ = L − 2 e L
Where:
- e B = M L / P = e_B = M_L / P = e B = M L / P = Eccentricity along width B B B
- e L = M B / P = e_L = M_B / P = e L = M B / P = Eccentricity along length L L L
- A ′ = B ′ ⋅ L ′ = A' = B' \cdot L' = A ′ = B ′ ⋅ L ′ = Effective footing area
- Application Rules for Bearing Capacity Equations
In all general bearing capacity equations (Meyerhof, Vesic, Hansen), use effective dimensions B ′ B' B ′ and L ′ L' L ′ to compute shape factors s c , s q , s γ s_c, s_q, s_\gamma s c , s q , s γ (e.g., s q = 1 + B ′ L ′ tan ϕ ′ s_q = 1 + \frac{B'}{L'} \tan\phi' s q = 1 + L ′ B ′ tan ϕ ′ ).
The third term of the bearing capacity equation ( 0.5 γ B ′ N γ s γ 0.5 \gamma B' N_\gamma s_\gamma 0.5 γ B ′ N γ s γ ) uses B ′ B' B ′ (always the smaller of B ′ B' B ′ and L ′ L' L ′ ).
Ultimate load capacity P u l t P_{ult} P u lt is calculated by multiplying ultimate effective bearing capacity q u l t ′ q_{ult}' q u lt ′ by the effective area A ′ A' A ′ : P u l t = q u l t ′ ⋅ A ′ = q u l t ′ ⋅ ( B ′ L ′ ) P_{ult} = q_{ult}' \cdot A' = q_{ult}' \cdot (B' L') P u lt = q u lt ′ ⋅ A ′ = q u lt ′ ⋅ ( B ′ L ′ )
Bi-Directional Eccentricity and the Kern Region
When eccentricity occurs simultaneously along both axes ( e B e_B e B and e L e_L e L ), base tension is avoided if the load resultant falls within the Kern region of the footing: e B B + e L L ≤ 1 6 \frac{e_B}{B} + \frac{e_L}{L} \le \frac{1}{6} B e B + L e L ≤ 6 1 Kern Zone of Rectangular Footing
- ┌───────────┐ +L/2
- │ ▲ │
- │ ╱│╲ │
- │ ╱ │ ╲ │
- ───────┼──◄──┼──►──┼───────
- │ ╲ │ ╱ │ -B/6 to +B/6
- │ ╲│╱ │
- │ ▼ │
- └───────────┘ -L/2
- B/2 +B/2
- Combined Footings Design
When column loads are heavy, space is restricted, or an exterior column sits directly against a property boundary, individual spread footings may overlap or experience severe load eccentricity. Combined footings support two or more columns on a single structural slab.
1. Rectangular Combined Footings
Used when the exterior column load P 1 P_1 P 1 is smaller than or comparable to interior load P 2 P_2 P 2 , allowing the footing to extend past column P 2 P_2 P 2 . Rectangular Combined Footing Layout
- Property Line
- │ P1 = Exterior P2 = Interior
- │ Column Column
- ▼ │ │
- ┌─────┴──────────────────────────┴─────┐
- │ Footing │
- └──────────────────┬───────────────────┘
- ◄────── x_bar ─────►
- ◄───────────────────── L ──────────────►
Design Equations for Rectangular Footings:
Resultant load magnitude: R = P 1 + P 2 R = P_1 + P_2 R = P 1 + P 2
Resultant location x ˉ \bar{x} x ˉ measured from center of exterior column P 1 P_1 P 1 (spaced distance S S S from P 2 P_2 P 2 ): x ˉ = P 2 ⋅ S P 1 + P 2 \bar{x} = \frac{P_2 \cdot S}{P_1 + P_2} x ˉ = P 1 + P 2 P 2 ⋅ S
Distance from property line to resultant: X c g = L m a r g i n + x ˉ X_{cg} = L_{margin} + \bar{x} X c g = L ma r g in + x ˉ (where L m a r g i n L_{margin} L ma r g in is distance from property line to column P 1 P_1 P 1 center).
To achieve uniform base pressure ( e = 0 e = 0 e = 0 ), footing length L L L must be centered on the resultant: L = 2 ⋅ X c g = 2 ( L m a r g i n + x ˉ ) L = 2 \cdot X_{cg} = 2 (L_{margin} + \bar{x}) L = 2 ⋅ X c g = 2 ( L ma r g in + x ˉ )
Required footing width B B B based on net allowable soil pressure q n e t , a l l q_{net,all} q n e t , a ll : B = P 1 + P 2 L ⋅ q n e t , a l l B = \frac{P_1 + P_2}{L \cdot q_{net,all}} B = L ⋅ q n e t , a ll P 1 + P 2
2. Trapezoidal Combined Footings
Used when property line constraints limit the extension of L L L ( L < 2 X c g L < 2 X_{cg} L < 2 X c g ), or when exterior load P 1 > P 2 P_1 > P_2 P 1 > P 2 . Trapezoidal Combined Footing Footprint
- Property Line
- │
- ▼ ┌───────────────────────┐ Width B1 (Larger)
- │ │ P1 P2 │
- │ └───────────────────────┘ Width B2 (Smaller)
- ◄───────────── L ──────────►
Design Equations for Trapezoidal Footings: Area A = ( B 1 + B 2 2 ) L = P 1 + P 2 q n e t , a l l \text{Area } A = \left( \frac{B_1 + B_2}{2} \right) L = \frac{P_1 + P_2}{q_{net,all}} Area A = ( 2 B 1 + B 2 ) L = q n e t , a ll P 1 + P 2 X c g = L 3 ( B 1 + 2 B 2 B 1 + B 2 ) X_{cg} = \frac{L}{3} \left( \frac{B_1 + 2 B_2}{B_1 + B_2} \right) X c g = 3 L ( B 1 + B 2 B 1 + 2 B 2 )
Solving simultaneously for width dimensions B 1 B_1 B 1 (exterior edge) and B 2 B_2 B 2 (interior edge): B 1 = 2 A L ( 3 X c g L − 1 ) B_1 = \frac{2 A}{L} \left( 3 \frac{X_{cg}}{L} - 1 \right) B 1 = L 2 A ( 3 L X c g − 1 ) B 2 = 2 A L ( 2 − 3 X c g L ) B_2 = \frac{2 A}{L} \left( 2 - 3 \frac{X_{cg}}{L} \right) B 2 = L 2 A ( 2 − 3 L X c g )
3. Strap (Cantilever) Footings
Strap footings connect an eccentrically loaded exterior column footing to an interior footing using a rigid concrete beam (strap). The strap beam is elevated above the soil so it transfers zero vertical soil bearing pressure, serving purely as a rigid moment transfer tie.
- Comprehensive Worked Calculation Example
- Problem Statement
An exterior column P 1 = 650 kN P_1 = 650\text{ kN} P 1 = 650 kN is located at a property boundary ( L m a r g i n = 0.3 m L_{margin} = 0.3\text{ m} L ma r g in = 0.3 m from property line to column center). An interior column P 2 = 1100 kN P_2 = 1100\text{ kN} P 2 = 1100 kN is located 4.2 m 4.2\text{ m} 4.2 m center-to-center from column P 1 P_1 P 1 . The net allowable bearing pressure is q n e t , a l l = 140 kPa q_{net,all} = 140\text{ kPa} q n e t , a ll = 140 kPa .
Design a rectangular combined footing to achieve uniform contact pressure ( e = 0 e = 0 e = 0 ).
- Determine required footing length L L L
- Determine required footing width B B B
- Calculate uniform ground pressure under service loads
- Solution Steps
Step 1: Calculate Resultant Force and Location x ˉ \bar{x} x ˉ R = P 1 + P 2 = 650 + 1100 = 1750 kN R = P_1 + P_2 = 650 + 1100 = 1750\text{ kN} R = P 1 + P 2 = 650 + 1100 = 1750 kN
Taking moments about the center of column P 1 P_1 P 1 : x ˉ = P 2 ⋅ S P 1 + P 2 = 1100 × 4.2 1750 = 4620 1750 = 2.64 m \bar{x} = \frac{P_2 \cdot S}{P_1 + P_2} = \frac{1100 \times 4.2}{1750} = \frac{4620}{1750} = 2.64\text{ m} x ˉ = P 1 + P 2 P 2 ⋅ S = 1750 1100 × 4.2 = 1750 4620 = 2.64 m
Step 2: Calculate Distance from Property Line to Resultant X c g X_{cg} X c g X c g = L m a r g i n + x ˉ = 0.3 + 2.64 = 2.94 m X_{cg} = L_{margin} + \bar{x} = 0.3 + 2.64 = 2.94\text{ m} X c g = L ma r g in + x ˉ = 0.3 + 2.64 = 2.94 m
Step 3: Compute Required Footing Length L L L
To ensure e = 0 e = 0 e = 0 , the resultant must coincide with the midpoint of L L L : L = 2 ⋅ X c g = 2 × 2.94 = 5.88 m L = 2 \cdot X_{cg} = 2 \times 2.94 = 5.88\text{ m} L = 2 ⋅ X c g = 2 × 2.94 = 5.88 m
Step 4: Compute Required Footing Width B B B A r e q = R q n e t , a l l = 1750 kN 140 kPa = 12.50 m 2 A_{req} = \frac{R}{q_{net,all}} = \frac{1750\text{ kN}}{140\text{ kPa}} = 12.50\text{ m}^2 A re q = q n e t , a ll R = 140 kPa 1750 kN = 12.50 m 2 B = A r e q L = 12.50 5.88 = 2.126 m ≈ 2.15 m B = \frac{A_{req}}{L} = \frac{12.50}{5.88} = 2.126\text{ m} \approx 2.15\text{ m} B = L A re q = 5.88 12.50 = 2.126 m ≈ 2.15 m
Step 5: Verify Final Uniform Contact Stress
Using B = 2.15 m B = 2.15\text{ m} B = 2.15 m and L = 5.88 m L = 5.88\text{ m} L = 5.88 m ( A a c t u a l = 12.642 m 2 A_{actual} = 12.642\text{ m}^2 A a c t u a l = 12.642 m 2 ): q a c t u a l = 1750 12.642 = 138.4 kPa ≤ 140 kPa (OK) q_{actual} = \frac{1750}{12.642} = 138.4\text{ kPa} \le 140\text{ kPa} \quad \text{(OK)} q a c t u a l = 12.642 1750 = 138.4 kPa ≤ 140 kPa (OK)