Study guide

10.1 Driven Pile Axial Capacity & Settlement

PE Civil Geotechnical Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Site Characterization

1.1 Site Data Interpretation & Boring Plans 1.2 In Situ Testing & Field Exploration 1.3 Soil and Rock Classification Systems 1.4 Groundwater Characterization & Hydrogeology

2 Chapter 2: Soil Mechanics, Laboratory Testing, and Analysis

2.1 Weight-Volume Phase Relationships & Index Properties 2.2 Effective Stress & Pore Water Pressure Dynamics 2.3 Shear Strength Principles & Laboratory Testing 2.4 Permeability, Hydraulic Conductivity & Seepage Properties 2.5 Consolidation & Compressibility Analysis

3 Chapter 3: Construction Observation, Monitoring, QA/QC, and Safety

3.1 Earthwork Quality Control & Compaction Verification 3.2 Geotechnical Instrumentation & Field Monitoring 3.3 Trenching, Excavation Safety & OSHA Shoring Requirements 3.4 Erosion, Scour Protection & Slope Protection During Construction

4 Chapter 4: Earthquake Engineering and Dynamic Loads

4.1 Seismic Site Characterization & Ground Motion Hazards 4.2 Soil Liquefaction Triggering & Post-Liquefaction Assessment 4.3 Dynamic Soil Properties & Ground Response Analysis 4.4 Pseudostatic Analysis & Seismic Geotechnical Design

5 Chapter 5: Earth Structures, Ground Improvement, and Pavement

5.1 Slope Stability Analysis & Limit Equilibrium Methods 5.2 Embankments, Earth Dams & Levee Geotechnics 5.3 Ground Improvement Techniques & Design 5.4 Geosynthetics in Geotechnical Engineering 5.5 Flexible & Rigid Pavement Subgrades & Buried Utilities 5.6 Landfills, Caps & Containment Systems

6 Chapter 6: Groundwater and Seepage

6.1 Dewatering System Design & Well Drawdown 6.2 Flow Nets & Two-Dimensional Seepage Analysis 6.3 Uplift Pressure, Piping & Heave Safety 6.4 Subsurface Drainage Systems & Filter Criteria

7 Chapter 7: Problematic Soil and Rock Conditions

7.1 Expansive & Collapsible Soil Engineering 7.2 Organic Soils, Sensitive Clays & Soft Marine Deposits 7.3 Corrosive, Frost-Susceptible & Degradable Formations 7.4 Karst Topography, Rock Slopes & Rockfall Hazards

8 Chapter 8: Retaining Structures

8.1 Lateral Earth Pressure Theories 8.2 Rigid Retaining Wall Design 8.3 Flexible Retaining Walls & Sheet Pile Bulkheads 8.4 Temporary Support of Excavations 8.5 Mechanically Stabilized Earth (MSE) Walls & Soil Nail Structures 8.6 Cofferdams, Underpinning & Adjacent Infrastructure Effects

9 Chapter 9: Shallow Foundations

9.1 Ultimate & Allowable Bearing Capacity Theories 9.2 Effective Footing Area, Eccentricity & Combined Footings 9.3 Induced Stress Distribution & Immediate Elastic Settlement 9.4 Consolidation Settlement & Mat/Raft Foundation Design

10 Chapter 10: Deep Foundations

10.1 Driven Pile Axial Capacity & Settlement 10.2 Drilled Shaft Axial Design & Construction Methods 10.3 Lateral Load Behavior of Deep Foundations 10.4 Pile Group Dynamics, Efficiency & Downdrag 10.5 Dynamic Load Testing & Pile Integrity Evaluation

10.1 Driven Pile Axial Capacity & Settlement

Key Takeaways Explain This Topic AI

Ultimate static axial pile capacity equals the sum of ultimate base resistance (Qb = qb * Ab) and ultimate shaft resistance (Qs = sum(fs * As)) minus the effective weight of the pile.

In cohesionless soils (sands), unit skin friction fs = K * sigma'_v * tan(delta') is subject to a limiting value fs,max, while unit end bearing qb = sigma'_v * Nq is capped by critical depth limits ql.

In cohesive soils (clays), total stress analysis uses the empirical adhesion factor alpha (fs = alpha * cu), where alpha ranges from 1.0 in soft clay down to 0.35-0.50 in stiff overconsolidated clay.

Elastic settlement of a single axial pile consists of pile stem elastic deformation (S1), settlement caused by load transmitted at the pile tip (S2), and settlement caused by load transmitted along the shaft (S3).

Last updated: July 2026

10.1 Driven Pile Axial Capacity & Settlement

Driven deep foundations are structural members (steel H-piles, pipe piles, precast prestressed concrete piles, or timber piles) forced into the ground using impact or vibratory hammers. Driven piles displace soil (full-displacement or partial-displacement) or cut through it (non-displacement open-ended pipes or H-piles), significantly altering the surrounding soil stress state.

Static Ultimate Axial Capacity Formulation

The ultimate compressive load capacity Q u Q_u Q u ​ of a single driven pile is computed as the sum of ultimate skin friction (shaft resistance) Q s Q_s Q s ​ and ultimate end bearing (tip resistance) Q b Q_b Q b ​ , minus the effective pile weight W p W_p W p ​ (which is typically neglected in standard geotechnical calculations unless extraordinary pile self-weight exists): Q u = Q s + Q b − W p = ∑ i = 1 n f s , i A s , i + q b A b Q_u = Q_s + Q_b - W_p = \sum_{i=1}^{n} f_{s,i} A_{s,i} + q_b A_b Q u ​ = Q s ​ + Q b ​ − W p ​ = i = 1 ∑ n ​ f s , i ​ A s , i ​ + q b ​ A b ​

Where:

f s , i f_{s,i} f s , i ​ = unit skin friction (side resistance) along pile segment (i) (kPa or psf)

A s , i A_{s,i} A s , i ​ = perimeter surface area of pile segment (i) = P ⋅ Δ z i P \cdot \Delta z_i P ⋅ Δ z i ​ (m² or ft²)

  • (P) = pile perimeter (m or ft)
  • q b q_b q b ​ = unit end bearing capacity at the pile tip (kPa or psf)
  • A b A_b A b ​ = gross cross-sectional area of the pile tip (m² or ft²)

To determine the allowable design load Q a l l Q_{all} Q a ll ​ under Working Stress Design (WSD) or Allowable Stress Design (ASD): Q a l l = Q u F S or Q a l l = Q s F S s + Q b F S b Q_{all} = \frac{Q_u}{FS} \quad \text{or} \quad Q_{all} = \frac{Q_s}{FS_s} + \frac{Q_b}{FS_b} Q a ll ​ = FS Q u ​ ​ or Q a ll ​ = F S s ​ Q s ​ ​ + F S b ​ Q b ​ ​

Standard factors of safety range between (FS = 2.0) (when verified by field static load testing or dynamic wave equation analysis) and (FS = 3.0) (for empirical static design without dynamic load testing).

Axial Capacity in Cohesionless Soils (Sands & Gravels)

In granular soils, skin friction and end bearing depend primarily on the effective vertical stress σ v ′ \sigma'_v σ v ′ ​ , the internal friction angle ϕ ′ \phi' ϕ ′ , soil-pile interface friction angle δ ′ \delta' δ ′ , and lateral earth pressure coefficient (K).

1. Unit Side Resistance (Skin Friction)

Unit side resistance at depth (z) is calculated as: f s = K ⋅ σ v ′ ⋅ tan ⁡ ( δ ′ ) ≤ f s , m a x f_s = K \cdot \sigma'_v \cdot \tan(\delta') \le f_{s,max} f s ​ = K ⋅ σ v ′ ​ ⋅ tan ( δ ′ ) ≤ f s , ma x ​

Earth Pressure Coefficient ((K)): For driven displacement piles (e.g., closed-end pipe, precast concrete), driving compacts the sand, elevating (K) above K o K_o K o ​ (typically K = 1.0 to 2.0 K = 1.0\text{ to } 2.0 K = 1.0 to 2.0 ). For non-displacement piles (e.g., H-piles), K ≈ K o = 1 − sin ⁡ ϕ ′ K \approx K_o = 1 - \sin\phi' K ≈ K o ​ = 1 − sin ϕ ′ .

Interface Friction Angle ( δ ′ \delta' δ ′ ): Usually taken as δ ′ = 0.60 ϕ ′ to 0.80 ϕ ′ \delta' = 0.60\phi'\text{ to } 0.80\phi' δ ′ = 0.60 ϕ ′ to 0.80 ϕ ′ depending on pile material (steel: δ ′ ≈ 0.7 ϕ ′ \delta' \approx 0.7\phi' δ ′ ≈ 0.7 ϕ ′ ; smooth concrete: δ ′ ≈ 0.8 ϕ ′ \delta' \approx 0.8\phi' δ ′ ≈ 0.8 ϕ ′ ; rough concrete: δ ′ ≈ 1.0 ϕ ′ \delta' \approx 1.0\phi' δ ′ ≈ 1.0 ϕ ′ ).

Limiting Skin Friction ( f s , m a x f_{s,max} f s , ma x ​ ): Due to soil arching and particle crushing along the pile shaft, vertical effective stress reaches a pseudo-critical threshold at depths of (15D) to (20D). Design standards cap f s f_s f s ​ at maximum thresholds (typically 100 kPa to 150 kPa / 2,000 psf to 3,000 psf).

2. Unit End Bearing Capacity

Unit end bearing in sand is derived from bearing capacity theory: q b = σ v ′ ⋅ N q ≤ q l q_b = \sigma'_v \cdot N_q \le q_l q b ​ = σ v ′ ​ ⋅ N q ​ ≤ q l ​

σ v ′ \sigma'_v σ v ′ ​ = effective vertical stress at the pile tip (kPa or psf)

N q N_q N q ​ = bearing capacity factor for deep foundations (from Meyerhof, Berezantsev, or Nordlund charts, which are significantly higher than shallow foundation N q N_q N q ​ values due to deep embedment containment).

q l q_l q l ​ = limiting unit end bearing capacity (Meyerhof recommendation: q l = 0.5 ⋅ N q ⋅ tan ⁡ ϕ ′ q_l = 0.5 \cdot N_q \cdot \tan\phi' q l ​ = 0.5 ⋅ N q ​ ⋅ tan ϕ ′ in MPa, or q l = 50 N q tan ⁡ ϕ ′ q_l = 50 N_q \tan\phi' q l ​ = 50 N q ​ tan ϕ ′ in kPa).

Pile Type Soil Type / Relative Density K / K o K/K_o K / K o ​ Ratio δ ′ / ϕ ′ \delta'/\phi' δ ′ / ϕ ′ Ratio Limiting f s , m a x f_{s,max} f s , ma x ​ (kPa)

  • Driven H-Pile Loose Sand 0.7 - 0.9 0.65 50 - 70
  • Driven H-Pile Dense Sand 1.0 - 1.2 0.70 80 - 100
  • Closed Pipe / Precast Medium Sand 1.2 - 1.5 0.80 100 - 120
  • Closed Pipe / Precast Dense Sand 1.5 - 2.0 0.90 120 - 150
  • Axial Capacity in Cohesive Soils (Clays & Silts)

Design in clay strata utilizes total stress (alpha method) or effective stress (beta and lambda methods).

1. Total Stress Analysis: Alpha ( α \alpha α ) Method

The α \alpha α -method relates unit side resistance directly to undrained shear strength c u c_u c u ​ : f s = α ⋅ c u f_s = \alpha \cdot c_u f s ​ = α ⋅ c u ​

Where α \alpha α is an empirical adhesion factor reflecting clay remolding, stress relief, and pile insertion disturbance. API RP 2A guidelines express α \alpha α as a function of the normalized strength ratio ψ = c u / σ v ′ \psi = c_u / \sigma'_v ψ = c u ​ / σ v ′ ​ : α = { 1.0 for ψ ≤ 0.5 0.5 ⋅ ψ − 0.5 for ψ > 0.5 ( with α ≤ 1.0 ) \alpha = \begin{cases} 1.0 & \text{for } \psi \le 0.5 \ 0.5 \cdot \psi^{-0.5} & \text{for } \psi > 0.5 \quad (\text{with } \alpha \le 1.0) \end{cases} α = { 1.0 ​ for ψ ≤ 0.5 0.5 ⋅ ψ − 0.5 ​ for ψ > 0.5 ( with α ≤ 1.0 ) ​

For soft to medium clays ( c u < 50 c_u < 50 c u ​ < 50 kPa), α ≈ 0.8 − 1.0 \alpha \approx 0.8 - 1.0 α ≈ 0.8 − 1.0 . For stiff to hard overconsolidated clays ( c u > 150 c_u > 150 c u ​ > 150 kPa), α \alpha α drops to (0.35 - 0.50).

Unit end bearing in clay is evaluated at deep failure conditions using Skempton's limit: q b = N c ⋅ c u = 9 ⋅ c u q_b = N_c \cdot c_u = 9 \cdot c_u q b ​ = N c ​ ⋅ c u ​ = 9 ⋅ c u ​

Where N c = 9.0 N_c = 9.0 N c ​ = 9.0 for deep embedded circular or square foundations ( D / B ≥ 5 D/B \ge 5 D / B ≥ 5 ).

2. Effective Stress Analysis: Beta ( β \beta β ) Method

Applicable for long-term drained conditions or fully reconsolidated clays: f s = β ⋅ σ v ′ = ( K ⋅ tan ⁡ δ ′ ) ⋅ σ v ′ f_s = \beta \cdot \sigma'_v = (K \cdot \tan\delta') \cdot \sigma'_v f s ​ = β ⋅ σ v ′ ​ = ( K ⋅ tan δ ′ ) ⋅ σ v ′ ​

For normally consolidated clays, β = ( 1 − sin ⁡ ϕ ′ ) tan ⁡ ϕ ′ ≈ 0.25 − 0.35 \beta = (1 - \sin\phi') \tan\phi' \approx 0.25 - 0.35 β = ( 1 − sin ϕ ′ ) tan ϕ ′ ≈ 0.25 − 0.35 . For overconsolidated clays, β = ( 1 − sin ⁡ ϕ ′ ) O C R tan ⁡ ϕ ′ \beta = (1 - \sin\phi') \sqrt{OCR} \tan\phi' β = ( 1 − sin ϕ ′ ) OCR ​ tan ϕ ′ .

3. Lambda ( λ \lambda λ ) Method

The λ \lambda λ -method incorporates mean effective vertical stress σ ˉ v ′ \bar{\sigma}'_v σ ˉ v ′ ​ and mean undrained shear strength c ˉ u \bar{c}_u c ˉ u ​ over the total pile penetration length (L): f a v g = λ ⋅ ( σ ˉ v ′ + 2 c ˉ u ) f_{avg} = \lambda \cdot \left( \bar{\sigma}'_v + 2 \bar{c}_u \right) f a vg ​ = λ ⋅ ( σ ˉ v ′ ​ + 2 c ˉ u ​ )

Where λ \lambda λ decreases nonlinearly from (0.32) at pile length L = 10 m L = 10\text{ m} L = 10 m to (0.12) at L = 70 m L = 70\text{ m} L = 70 m .

Pile Elastic Settlement (Vesic's Method)

The elastic settlement (S) of a single driven pile under working load Q w Q_w Q w ​ consists of three structural and geotechnical components: S = S 1 + S 2 + S 3 S = S_1 + S_2 + S_3 S = S 1 ​ + S 2 ​ + S 3 ​

Elastic Compression of Pile Stem ( S 1 S_1 S 1 ​ ): S 1 = ( Q w p + ξ Q w s ) L A p E p S_1 = \frac{(Q_{wp} + \xi Q_{ws}) L}{A_p E_p} S 1 ​ = A p ​ E p ​ ( Q wp ​ + ξ Q w s ​ ) L ​

Where Q w p Q_{wp} Q wp ​ is the load carried at the pile tip under working load, Q w s Q_{ws} Q w s ​ is load carried by skin friction, E p E_p E p ​ is pile elastic modulus, A p A_p A p ​ is pile cross-sectional area, and ξ \xi ξ is skin friction distribution factor ( ξ = 0.5 \xi = 0.5 ξ = 0.5 for uniform or parabolic distribution, ξ = 0.67 \xi = 0.67 ξ = 0.67 for triangular distribution increasing with depth).

Settlement Caused by Load at Pile Tip ( S 2 S_2 S 2 ​ ): S 2 = Q w p C p D ⋅ q b S_2 = \frac{Q_{wp} C_p}{D \cdot q_b} S 2 ​ = D ⋅ q b ​ Q wp ​ C p ​ ​

Where C p C_p C p ​ is an empirical coefficient (0.02 for sand/gravel, 0.04 for clay), and (D) is pile diameter/width.

Settlement Caused by Load Transmitted Along Shaft ( S 3 S_3 S 3 ​ ): S 3 = Q w s C s L ⋅ q b S_3 = \frac{Q_{ws} C_s}{L \cdot q_b} S 3 ​ = L ⋅ q b ​ Q w s ​ C s ​ ​

Where C s = ( 0.93 + 0.16 L / D ) C p C_s = (0.93 + 0.16 \sqrt{L/D}) C_p C s ​ = ( 0.93 + 0.16 L / D ​ ) C p ​ .

PE-Style Worked Example: Driven Pile Capacity

Problem: A closed-end steel pipe pile with an outer diameter D = 406 mm D = 406\text{ mm} D = 406 mm (0.406 m) is driven to a depth L = 18 m L = 18\text{ m} L = 18 m into a layered soil profile. The soil profile consists of:

Layer 1 (0 to 6 m): Soft to medium clay, γ 1 = 17.5 kN/m 3 \gamma_1 = 17.5\text{ kN/m}^3 γ 1 ​ = 17.5 kN/m 3 , undrained shear strength c u = 40 kPa c_u = 40\text{ kPa} c u ​ = 40 kPa .

Layer 2 (6 to 18 m): Dense sand, γ s a t = 19.5 kN/m 3 \gamma_{sat} = 19.5\text{ kN/m}^3 γ s a t ​ = 19.5 kN/m 3 , effective friction angle ϕ ′ = 36 ∘ \phi' = 36^\circ ϕ ′ = 3 6 ∘ , (K = 1.4), δ ′ = 28 ∘ \delta' = 28^\circ δ ′ = 2 8 ∘ .

The groundwater table is located at z = 3.0 m z = 3.0\text{ m} z = 3.0 m depth. Below GWT, unit weight of water γ w = 9.81 kN/m 3 \gamma_w = 9.81\text{ kN/m}^3 γ w ​ = 9.81 kN/m 3 .

Calculate:

Ultimate shaft resistance Q s Q_s Q s ​

Ultimate tip resistance Q b Q_b Q b ​ (using N q = 55 N_q = 55 N q ​ = 55 , capped at q l = 10 MPa q_l = 10\text{ MPa} q l ​ = 10 MPa )

Allowable design load Q a l l Q_{all} Q a ll ​ using a factor of safety (FS = 2.5).

Solution Step-by-Step:

1. Pile Geometry Parameters:

Perimeter P = π ⋅ D = π ⋅ 0.406 m = 1.2755 m P = \pi \cdot D = \pi \cdot 0.406\text{ m} = 1.2755\text{ m} P = π ⋅ D = π ⋅ 0.406 m = 1.2755 m

Tip Area A b = π 4 D 2 = π 4 ( 0.406 ) 2 = 0.1295 m 2 A_b = \frac{\pi}{4} D^2 = \frac{\pi}{4} (0.406)^2 = 0.1295\text{ m}^2 A b ​ = 4 π ​ D 2 = 4 π ​ ( 0.406 ) 2 = 0.1295 m 2

2. Layer 1 (Soft Clay, 0 to 6 m):

Shaft Area A s 1 = P ⋅ 6.0 m = 1.2755 ⋅ 6.0 = 7.653 m 2 A_{s1} = P \cdot 6.0\text{ m} = 1.2755 \cdot 6.0 = 7.653\text{ m}^2 A s 1 ​ = P ⋅ 6.0 m = 1.2755 ⋅ 6.0 = 7.653 m 2

Adhesion Factor α \alpha α : For c u = 40 kPa c_u = 40\text{ kPa} c u ​ = 40 kPa , c u < 50 kPa c_u < 50\text{ kPa} c u ​ < 50 kPa , so α = 1.0 \alpha = 1.0 α = 1.0 .

Unit Skin Friction f s 1 = α ⋅ c u = 1.0 ⋅ 40 = 40 kPa f_{s1} = \alpha \cdot c_u = 1.0 \cdot 40 = 40\text{ kPa} f s 1 ​ = α ⋅ c u ​ = 1.0 ⋅ 40 = 40 kPa

Shaft Capacity Layer 1: Q s 1 = f s 1 ⋅ A s 1 = 40 ⋅ 7.653 = 306.1 kN Q_{s1} = f_{s1} \cdot A_{s1} = 40 \cdot 7.653 = 306.1\text{ kN} Q s 1 ​ = f s 1 ​ ⋅ A s 1 ​ = 40 ⋅ 7.653 = 306.1 kN

3. Layer 2 (Dense Sand, 6 to 18 m):

Thickness Δ z 2 = 12.0 m \Delta z_2 = 12.0\text{ m} Δ z 2 ​ = 12.0 m

Shaft Area A s 2 = P ⋅ 12.0 m = 1.2755 ⋅ 12.0 = 15.306 m 2 A_{s2} = P \cdot 12.0\text{ m} = 1.2755 \cdot 12.0 = 15.306\text{ m}^2 A s 2 ​ = P ⋅ 12.0 m = 1.2755 ⋅ 12.0 = 15.306 m 2

Compute effective stress profile σ v ′ ( z ) \sigma'_v(z) σ v ′ ​ ( z ) :

σ v ′ ( z = 0 ) = 0 \sigma'_v(z=0) = 0 σ v ′ ​ ( z = 0 ) = 0

σ v ′ ( z = 3 m ) = 3.0 ⋅ 17.5 = 52.5 kPa \sigma'_v(z=3\text{ m}) = 3.0 \cdot 17.5 = 52.5\text{ kPa} σ v ′ ​ ( z = 3 m ) = 3.0 ⋅ 17.5 = 52.5 kPa

σ v ′ ( z = 6 m ) = 52.5 + 3.0 ⋅ ( 17.5 − 9.81 ) = 52.5 + 23.07 = 75.57 kPa \sigma'_v(z=6\text{ m}) = 52.5 + 3.0 \cdot (17.5 - 9.81) = 52.5 + 23.07 = 75.57\text{ kPa} σ v ′ ​ ( z = 6 m ) = 52.5 + 3.0 ⋅ ( 17.5 − 9.81 ) = 52.5 + 23.07 = 75.57 kPa

σ v ′ ( z = 18 m ) = 75.57 + 12.0 ⋅ ( 19.5 − 9.81 ) = 75.57 + 116.28 = 191.85 kPa \sigma'_v(z=18\text{ m}) = 75.57 + 12.0 \cdot (19.5 - 9.81) = 75.57 + 116.28 = 191.85\text{ kPa} σ v ′ ​ ( z = 18 m ) = 75.57 + 12.0 ⋅ ( 19.5 − 9.81 ) = 75.57 + 116.28 = 191.85 kPa

Average effective stress in Layer 2 (6 to 18 m): σ ˉ v 2 ′ = 75.57 + 191.85 2 = 133.71 kPa \bar{\sigma}'_{v2} = \frac{75.57 + 191.85}{2} = 133.71\text{ kPa} σ ˉ v 2 ′ ​ = 2 75.57 + 191.85 ​ = 133.71 kPa

Unit Skin Friction Layer 2: f s 2 = K ⋅ σ ˉ v 2 ′ ⋅ tan ⁡ ( δ ′ ) = 1.4 ⋅ 133.71 ⋅ tan ⁡ ( 28 ∘ ) = 1.4 ⋅ 133.71 ⋅ 0.5317 = 99.53 kPa f_{s2} = K \cdot \bar{\sigma}'_{v2} \cdot \tan(\delta') = 1.4 \cdot 133.71 \cdot \tan(28^\circ) = 1.4 \cdot 133.71 \cdot 0.5317 = 99.53\text{ kPa} f s 2 ​ = K ⋅ σ ˉ v 2 ′ ​ ⋅ tan ( δ ′ ) = 1.4 ⋅ 133.71 ⋅ tan ( 2 8 ∘ ) = 1.4 ⋅ 133.71 ⋅ 0.5317 = 99.53 kPa

(This is below typical limit f s , m a x = 120 kPa f_{s,max} = 120\text{ kPa} f s , ma x ​ = 120 kPa , so f s 2 = 99.53 kPa f_{s2} = 99.53\text{ kPa} f s 2 ​ = 99.53 kPa ) .

Shaft Capacity Layer 2: Q s 2 = f s 2 ⋅ A s 2 = 99.53 ⋅ 15.306 = 1523.4 kN Q_{s2} = f_{s2} \cdot A_{s2} = 99.53 \cdot 15.306 = 1523.4\text{ kN} Q s 2 ​ = f s 2 ​ ⋅ A s 2 ​ = 99.53 ⋅ 15.306 = 1523.4 kN

Total Ultimate Shaft Resistance: Q s = Q s 1 + Q s 2 = 306.1 + 1523.4 = 1829.5 kN Q_s = Q_{s1} + Q_{s2} = 306.1 + 1523.4 = 1829.5\text{ kN} Q s ​ = Q s 1 ​ + Q s 2 ​ = 306.1 + 1523.4 = 1829.5 kN

4. Ultimate End Bearing Q b Q_b Q b ​ at z = 18 m z = 18\text{ m} z = 18 m :

Effective vertical stress at pile tip: σ v ′ ( z = 18 ) = 191.85 kPa \sigma'_v(z=18) = 191.85\text{ kPa} σ v ′ ​ ( z = 18 ) = 191.85 kPa

Calculated unit end bearing: q b = σ v ′ ⋅ N q = 191.85 kPa ⋅ 55 = 10 , 551.75 kPa = 10.55 MPa q_b = \sigma'_v \cdot N_q = 191.85 \text{ kPa} \cdot 55 = 10,551.75\text{ kPa} = 10.55\text{ MPa} q b ​ = σ v ′ ​ ⋅ N q ​ = 191.85 kPa ⋅ 55 = 10 , 551.75 kPa = 10.55 MPa

Check limiting unit end bearing q l = 10.0 MPa = 10 , 000 kPa q_l = 10.0\text{ MPa} = 10,000\text{ kPa} q l ​ = 10.0 MPa = 10 , 000 kPa .

Since 10.55 MPa > 10.0 MPa 10.55\text{ MPa} > 10.0\text{ MPa} 10.55 MPa > 10.0 MPa , use q b = 10 , 000 kPa q_b = 10,000\text{ kPa} q b ​ = 10 , 000 kPa .

Total Ultimate Base Capacity: Q b = q b ⋅ A b = 10 , 000 kPa ⋅ 0.1295 m 2 = 1295.0 kN Q_b = q_b \cdot A_b = 10,000 \text{ kPa} \cdot 0.1295\text{ m}^2 = 1295.0\text{ kN} Q b ​ = q b ​ ⋅ A b ​ = 10 , 000 kPa ⋅ 0.1295 m 2 = 1295.0 kN

5. Total Ultimate Capacity and Allowable Load:

Ultimate Capacity Q u = Q s + Q b = 1829.5 + 1295.0 = 3124.5 kN Q_u = Q_s + Q_b = 1829.5 + 1295.0 = 3124.5\text{ kN} Q u ​ = Q s ​ + Q b ​ = 1829.5 + 1295.0 = 3124.5 kN

Allowable Design Load: Q a l l = Q u F S = 3124.5 kN 2.5 = 1249.8 kN ≈ 1250 kN Q_{all} = \frac{Q_u}{FS} = \frac{3124.5\text{ kN}}{2.5} = 1249.8\text{ kN} \approx 1250\text{ kN} Q a ll ​ = FS Q u ​ ​ = 2.5 3124.5 kN ​ = 1249.8 kN ≈ 1250 kN

Loading diagram... Figure 10.1: Driven Pile Axial Load Transfer Mechanisms