Study guide
12.2 Vibration Isolation, Multi-DOF Systems & Transmissibility
PE Mechanical: Machine Design and Materials Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Basic Engineering Practice: Drawings, Economics & Design Methodology
1.1 Engineering Terms, Symbols, Drawing Interpretation & Conventions 1.2 Project Management & Engineering Economics 1.3 Design Methodology, Risk Assessment & Safety
2 Chapter 2: Physical & Mechanical Properties of Engineering Materials
2.1 Stress-Strain Relationships & Fundamental Mechanical Properties 2.2 Physical Properties, Temperature Effects, Hardness, Impact Toughness & Creep
3 Chapter 3: Mechanics of Materials: Fundamental Loadings & Deflections
3.1 Axial Loading, Normal Stress & Statically Indeterminate Members 3.2 Direct Shear, Bearing & Transverse Shear in Beams 3.3 Torsion of Shafts, Power Transmission & Thin-Walled Tubes 3.4 Beam Bending Stresses & Deflection Analysis
4 Chapter 4: Mechanics of Materials: Stability, Multiaxial Stress & Thermal Effects
4.1 Column Buckling & Elastic/Inelastic Instability 4.2 Combined Loading, Principal Stresses & Mohr's Circle 4.3 Thermal Stresses & Interference Stresses
5 Chapter 5: Failure Theories: Static Yielding & Fracture Mechanics
5.1 Static Failure Theories for Ductile Materials: von Mises & Tresca 5.2 Static Failure Theories for Brittle Materials & Fracture Mechanics
6 Chapter 6: Fatigue Analysis & Dynamic Failure
6.1 High-Cycle Fatigue, S-N Curves & Marin Modifying Factors 6.2 Fluctuating Stresses, Failure Criteria & Cumulative Damage
7 Chapter 7: Mechanical Attachments: Fasteners & Bolted Joints
7.1 Threaded Fasteners, Proof Strength & Preload Mechanics 7.2 Bolted Joint Stiffness, External Loading & Separation 7.3 Non-Threaded Fasteners: Keys, Pins, Clevises, Retaining Rings, Rivets, Lugs & Anchors
8 Chapter 8: Mechanical Attachments: Permanent Joints & Bonding
8.1 Welded Joints & Weld Group Stress Analysis 8.2 Brazing, Soldering & Structural Adhesive Bonding
9 Chapter 9: Power Transmission: Shafts & Gearing
9.1 Transmission Shaft Design, Critical Speeds & Deflection 9.2 Spur Gears: Geometry, Kinematics & AGMA Stress Equations 9.3 Helical, Bevel & Worm Gearing
10 Chapter 10: Power Transmission: Bearings, Flexible Drives, Friction Devices & Prime Movers
10.1 Rolling-Element Bearings & L10 Life Calculations 10.2 Hydrodynamic Journal Bearings & Lubrication Regimes 10.3 Belts, Roller Chains & Flexible Drives 10.4 Clutches, Brakes & Power Screws 10.5 Electric Motors, Engines & Flywheels
11 Chapter 11: Mechanical Components: Pressure Vessels & Structural Systems
11.1 Pressure Vessels & Piping: Thin and Thick Walls, ASME VIII and B31 11.2 Mechanical Springs: Helical, Belleville & Leaf Springs 11.3 Structural Trusses, Rigid Frames & Energy Methods
12 Chapter 12: Mechanical Dynamics, Vibrations & Fluid Power
12.1 Single-Degree-of-Freedom Vibrations & Resonance 12.2 Vibration Isolation, Multi-DOF Systems & Transmissibility 12.3 Fluid Power Systems: Hydraulics & Pneumatics
13 Chapter 13: Kinematics, Mechatronics & Control Systems
13.1 Mechanism Kinematics, Linkages, Cams & Simple Machines 13.2 Basic Mechatronics, Sensors & Closed-Loop Controls
14 Chapter 14: Supportive Knowledge: Fits, Tolerances & Manufacturing Methods
14.1 Limits, Fits & Geometric Dimensioning & Tolerancing (GD&T) 14.2 Manufacturing Methods, Machinability, Heat Treatment & Assembly
15 Chapter 15: Supportive Knowledge: Codes, Computation, Testing & Corrosion
15.1 Engineering Codes & Standards 15.2 Computational Methods: FEA & Numerical Analysis 15.3 Instrumentation, Testing, Inspection & Quality 15.4 Chemical Processes: Corrosion, Oxidation & Embrittlement
12.2 Vibration Isolation, Multi-DOF Systems & Transmissibility
Key Takeaways Explain This Topic AI
Vibration isolation ( T R < 1.0 TR < 1.0 TR < 1.0 ) is mathematically impossible unless the operating frequency ratio exceeds 2 ≈ 1.414 \sqrt{2} \approx 1.414 2 ≈ 1.414 ; at lower frequency ratios ( r < 2 r < \sqrt{2} r < 2 ), mounts amplify dynamic forces transmitted to the foundation.
Force transmissibility and motion transmissibility share the identical mathematical relationship T R = [ 1 + ( 2 ζ r ) 2 ] / [ ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ] TR = \sqrt{[1 + (2\zeta r)^2] / [(1-r^2)^2 + (2\zeta r)^2]} TR = [ 1 + ( 2 ζ r ) 2 ] / [( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ] , linking source isolation and receiver isolation under a single unified formulation.
The Damping Paradox dictates that while viscous damping reduces peak resonance amplitudes during start-up and shutdown, it degrades high-frequency isolation performance ( r > 2 r > \sqrt{2} r > 2 ) by transmitting higher forces through the damper.
Multi-degree-of-freedom undamped systems satisfy [ M ] x ¨ + [ K ] x = 0 [M]\mathbf{\ddot{x}} + [K]\mathbf{x} = \mathbf{0} [ M ] x ¨ + [ K ] x = 0 , producing natural frequencies and orthogonal mode shapes from the characteristic determinant det ( [ K ] − ω 2 [ M ] ) = 0 \det([K] - \omega^2[M]) = 0 det ([ K ] − ω 2 [ M ]) = 0 .
A tuned mass damper (TMD) tuned to ω a = k a / m a = Ω \omega_a = \sqrt{k_a/m_a} = \Omega ω a = k a / m a = Ω completely eliminates steady-state motion of the primary mass at the tuning frequency, splitting the single original resonance peak into two distinct side peaks.
Last updated: October 2026
12.2 Vibration Isolation, Multi-DOF Systems & Transmissibility
Vibration isolation prevents the transmission of dynamic forces from operating machinery into supporting structures or, conversely, protects sensitive instrumentation from floor vibration. Achieving effective isolation requires proper matching of mount stiffness, operating speeds, and damping ratios. This section examines force and motion transmissibility, the fundamental isolation threshold r > 2 r > \sqrt{2} r > 2 , isolator selection, and multi-degree-of-freedom (MDOF) modal dynamics including tuned mass dampers.
Principles of Vibration Isolation: Source vs. Receiver
Vibration isolation addresses two complementary engineering problems:
Source Isolation (Direct Force Excitation) : A vibrating machine generates internal unbalanced dynamic forces F ( t ) = F 0 cos ( ω t ) F(t) = F_0 \cos(\omega t) F ( t ) = F 0 cos ( ω t ) . The objective is to minimize the dynamic force F T F_T F T transmitted through the mounts into the supporting floor or foundation.
Receiver Isolation (Base Motion Excitation) : Ground or foundation displacement y ( t ) = Y 0 cos ( ω t ) y(t) = Y_0 \cos(\omega t) y ( t ) = Y 0 cos ( ω t ) (from seismic activity, traffic, or nearby forging presses) vibrates the mounts. The objective is to minimize the absolute displacement response X X X transmitted to a sensitive instrument or payload. Source Isolation Receiver Isolation
- +---------------------------+ +---------------------------+
- | Machine: F(t)=F_0 cos(wt) | | Sensitive Metrology CMM |
- +-------------+-------------+ +-------------+-------------+
- | | | |
- [k] [c] [k] [c]
- | | | |
- =======+=============+======= =======+=============+=======
- Foundation: Transmitted Force F_T Moving Base: y(t)=Y_0 cos(wt)
- Force Transmitted to the Foundation
In source isolation, the machine mass moves with displacement x ( t ) = X cos ( ω t − ϕ ) x(t) = X \cos(\omega t - \phi) x ( t ) = X cos ( ω t − ϕ ) . The dynamic force transmitted to the foundation is the vector sum of spring force and viscous damping force: f T ( t ) = k x ( t ) + c x ˙ ( t ) = k X cos ( ω t − ϕ ) − c ω X sin ( ω t − ϕ ) f_T(t) = k x(t) + c \dot{x}(t) = k X \cos(\omega t - \phi) - c \omega X \sin(\omega t - \phi) f T ( t ) = k x ( t ) + c x ˙ ( t ) = k X cos ( ω t − ϕ ) − c ω X sin ( ω t − ϕ )
Because the spring force and damping force are 90 ∘ 90^\circ 9 0 ∘ out of phase, their resultant peak amplitude is found via vector (phasor) addition: F T = ( k X ) 2 + ( c ω X ) 2 = X k 2 + c 2 ω 2 = k X 1 + ( c ω k ) 2 F_T = \sqrt{(k X)^2 + (c \omega X)^2} = X \sqrt{k^2 + c^2 \omega^2} = k X \sqrt{1 + \left(\frac{c\omega}{k}\right)^2} F T = ( k X ) 2 + ( c ω X ) 2 = X k 2 + c 2 ω 2 = k X 1 + ( k c ω ) 2
Recalling that c k = 2 ζ ω n ω n 2 = 2 ζ ω n \frac{c}{k} = \frac{2\zeta \omega_n}{\omega_n^2} = \frac{2\zeta}{\omega_n} k c = ω n 2 2 ζ ω n = ω n 2 ζ and r = ω ω n r = \frac{\omega}{\omega_n} r = ω n ω : F T = k X 1 + ( 2 ζ r ) 2 F_T = k X \sqrt{1 + (2\zeta r)^2} F T = k X 1 + ( 2 ζ r ) 2
Substituting the harmonic displacement amplitude X = F 0 / k ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 X = \frac{F_0 / k}{\sqrt{(1 - r^2)^2 + (2\zeta r)^2}} X = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 F 0 / k into the force equation gives: F T = F 0 [ 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ] F_T = F_0 \left[\frac{\sqrt{1 + (2\zeta r)^2}}{\sqrt{(1 - r^2)^2 + (2\zeta r)^2}}\right] F T = F 0 [ ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2 ]
Force and Motion Transmissibility Formula
The Transmissibility ( T R TR TR ) is defined as the ratio of transmitted force amplitude to applied excitation force amplitude: T R = F T F 0 = 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 TR = \frac{F_T}{F_0} = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}} TR = F 0 F T = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2
For base excitation (receiver isolation) where base displacement is y ( t ) = Y 0 cos ( ω t ) y(t) = Y_0 \cos(\omega t) y ( t ) = Y 0 cos ( ω t ) , Newton's equation yields the identical mathematical ratio for motion transmissibility: T R motion = X Y 0 = 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 TR_{\text{motion}} = \frac{X}{Y_0} = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}} T R motion = Y 0 X = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2
Force transmissibility and motion transmissibility are mathematically equivalent.
The Isolation Criteria: The r > 2 r > \sqrt{2} r > 2 Rule
To achieve true vibration isolation, the transmitted force must be strictly less than the excitation force ( T R < 1.0 TR < 1.0 TR < 1.0 ). Setting T R = 1.0 TR = 1.0 TR = 1.0 in the transmissibility equation reveals the critical operating boundary: 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 = 1.0 ⟹ ( 1 − r 2 ) 2 = 1.0 \frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2} = 1.0 \implies (1 - r^2)^2 = 1.0 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2 = 1.0 ⟹ ( 1 − r 2 ) 2 = 1.0
Taking the square root: 1 − r 2 = − 1 ⟹ r 2 = 2 ⟹ r = 2 ≈ 1.414 1 - r^2 = -1 \implies r^2 = 2 \implies r = \sqrt{2} \approx 1.414 1 − r 2 = − 1 ⟹ r 2 = 2 ⟹ r = 2 ≈ 1.414 Transmissibility TR vs Frequency Ratio r
- TR ^
- | /|\ Light Damping (Resonance Peak)
- 4.0 + / | \
- | / | \
- 2.0 + / | \
- | / | \
- 1.0 +-----+-----+-----\----+-------------------------> TR = 1.0
| / | \ \____ Higher damping has HIGHER TR here!
- 0.0 +---+-------+-------+----+----------------------->
- 0 0.5 r=1.0 r=sqrt(2) r
- Amplification Crossover ISOLATION REGION
- Region Boundary (TR < 1.0)
- Frequency Regimes of Transmissibility
0 < r < 1.0 0 < r < 1.0 0 < r < 1.0 (Stiffness Zone) : T R > 1.0 TR > 1.0 TR > 1.0 . Transmitted force exceeds applied force. At r = 0 r = 0 r = 0 , T R = 1.0 TR = 1.0 TR = 1.0 .
r = 1.0 r = 1.0 r = 1.0 (Resonance Zone) : T R TR TR reaches its maximum value, governed by damping: T R r = 1 = 1 + 4 ζ 2 2 ζ ≈ 1 2 ζ TR_{r=1} = \frac{\sqrt{1 + 4\zeta^2}}{2\zeta} \approx \frac{1}{2\zeta} T R r = 1 = 2 ζ 1 + 4 ζ 2 ≈ 2 ζ 1 .
1.0 < r < 2 1.0 < r < \sqrt{2} 1.0 < r < 2 (Amplification Zone) : T R > 1.0 TR > 1.0 TR > 1.0 . The mounts amplify force transmitted to the foundation.
r = 2 r = \sqrt{2} r = 2 (Crossover Point) : T R = 1.0 TR = 1.0 TR = 1.0 regardless of the value of damping ratio ζ \zeta ζ . All curves pass through ( r = 2 , T R = 1.0 ) (r = \sqrt{2}, TR = 1.0) ( r = 2 , TR = 1.0 ) .
r > 2 r > \sqrt{2} r > 2 (Isolation Zone) : T R < 1.0 TR < 1.0 TR < 1.0 . True vibration isolation occurs. Effective isolation requires operating well into this region, typically r ≥ 2.5 r \ge 2.5 r ≥ 2.5 to 4.0 4.0 4.0 .
Isolation Efficiency
The effectiveness of an isolator is expressed as Isolation Efficiency η I \eta_I η I : η I = ( 1 − T R ) × 100 % \eta_I = (1 - TR) \times 100\% η I = ( 1 − TR ) × 100%
For an undamped or lightly damped isolator ( ζ ≪ 1 \zeta \ll 1 ζ ≪ 1 ) operating in the isolation region ( r > 2 r > \sqrt{2} r > 2 ), transmissibility simplifies to: T R ≈ 1 r 2 − 1 TR \approx \frac{1}{r^2 - 1} TR ≈ r 2 − 1 1 η I ≈ ( 1 − 1 r 2 − 1 ) = r 2 − 2 r 2 − 1 \eta_I \approx \left(1 - \frac{1}{r^2 - 1}\right) = \frac{r^2 - 2}{r^2 - 1} η I ≈ ( 1 − r 2 − 1 1 ) = r 2 − 1 r 2 − 2
To achieve 90 % 90\% 90% isolation efficiency ( η I = 0.90 \eta_I = 0.90 η I = 0.90 , meaning T R = 0.10 TR = 0.10 TR = 0.10 ): 0.10 ≈ 1 r 2 − 1 ⟹ r 2 − 1 = 10 ⟹ r = 11 ≈ 3.317 0.10 \approx \frac{1}{r^2 - 1} \implies r^2 - 1 = 10 \implies r = \sqrt{11} \approx 3.317 0.10 ≈ r 2 − 1 1 ⟹ r 2 − 1 = 10 ⟹ r = 11 ≈ 3.317
The operating speed must be at least 3.32 3.32 3.32 times the natural frequency of the mounting system.
The Damping Paradox in Vibration Isolation
Examining the transmissibility plot reveals an important engineering trade-off known as the Damping Paradox :
In the resonant region ( r < 2 r < \sqrt{2} r < 2 ) : Damping is essential to limit excessive vibration amplitudes and structural stresses as machinery passes through resonance during startup and shutdown.
In the isolation region ( r > 2 r > \sqrt{2} r > 2 ) : Higher damping increases transmissibility ( T R TR TR ) and reduces isolation efficiency! The dashpot creates a direct dynamic path between the machine and foundation. At very high frequencies ( r ≫ 1 r \gg 1 r ≫ 1 ), the damper force dominates the spring force, causing T R TR TR to decay as 2 ζ / r 2\zeta / r 2 ζ / r rather than 1 / r 2 1 / r^2 1/ r 2 .
Important
For steady-state isolation at r > 2 r > \sqrt{2} r > 2 , lower damping provides superior isolation performance. Designers typically select light damping ( ζ ≈ 0.05 \zeta \approx 0.05 ζ ≈ 0.05 to 0.10 0.10 0.10 ) or employ elastomeric stops / limiters to constrain transient resonance excursions during machine run-up.
Isolator Media Selection & Properties
Isolator Type Useful Natural Frequency Range ( f n f_n f n ) Maximum Static Deflection ( δ s t \delta_{st} δ s t ) Typical Damping Ratio ( ζ \zeta ζ ) Characteristics & Engineering Applications
Elastomeric Mounts (Rubber/Neoprene) 7 − 20 Hz 7 - 20\,\text{Hz} 7 − 20 Hz ( 420 − 1 , 200 rpm 420 - 1,\!200\,\text{rpm} 420 − 1 , 200 rpm ) Up to 12 mm 12\,\text{mm} 12 mm ( 0.5 in 0.5\,\text{in} 0.5 in ) 0.05 − 0.15 0.05 - 0.15 0.05 − 0.15 High internal material damping; eliminates acoustic high-frequency noise; susceptible to oil degradation and thermal creep. Best for small engines, pumps, and fans.
Helical Steel Springs 1.5 − 6 Hz 1.5 - 6\,\text{Hz} 1.5 − 6 Hz ( 90 − 360 rpm 90 - 360\,\text{rpm} 90 − 360 rpm ) Up to 75 mm 75\,\text{mm} 75 mm ( 3.0 in 3.0\,\text{in} 3.0 in ) 0.005 − 0.015 0.005 - 0.015 0.005 − 0.015 Large static deflections achievable for low operating speeds; highly durable. Minimal damping requires auxiliary snubbers; transmits high-frequency acoustic surge (requires neoprene pad beneath spring).
Pneumatic (Air Springs) 0.5 − 2.5 Hz 0.5 - 2.5\,\text{Hz} 0.5 − 2.5 Hz ( 30 − 150 rpm 30 - 150\,\text{rpm} 30 − 150 rpm ) Variable / auto-leveling 0.02 − 0.08 0.02 - 0.08 0.02 − 0.08 Ultra-low natural frequencies for ultra-sensitive isolation (metrology CMMs, electron microscopes, wafer steppers); requires active compressed air supply.
Multi-Degree-of-Freedom (MDOF) Systems
Real mechanical installations possess multiple independent displacement coordinates. For an N N N -degree-of-freedom system, the generalized coordinate vector is x ( t ) = [ x 1 ( t ) , x 2 ( t ) , … , x N ( t ) ] T \mathbf{x}(t) = [x_1(t), x_2(t), \dots, x_N(t)]^T x ( t ) = [ x 1 ( t ) , x 2 ( t ) , … , x N ( t ) ] T .
Matrix Equations of Motion
For undamped free vibration, dynamic equilibrium yields the matrix system: [ M ] x ¨ + [ K ] x = 0 [M] \mathbf{\ddot{x}} + [K] \mathbf{x} = \mathbf{0} [ M ] x ¨ + [ K ] x = 0
where [ M ] [M] [ M ] is the N × N N \times N N × N symmetric, positive-definite mass matrix , and [ K ] [K] [ K ] is the N × N N \times N N × N symmetric stiffness matrix . Two-Degree-of-Freedom (2-DOF) System Model
- +------------------------------------------------+
- | Fixed Wall |
- +-------+--------------------------------+-------+
- | |
- [k_1] [k_3] (Optional)
- | |
- v v
- +-----------+ +-----------+
- | Mass (m_1)| <--- [k_2] ------->| Mass (m_2)|
- +-----------+ +-----------+
- x_1(t) x_2(t)
Assuming synchronous harmonic motion at circular frequency ω \omega ω : x ( t ) = u e i ω t \mathbf{x}(t) = \mathbf{u} e^{i \omega t} x ( t ) = u e iω t
Substituting into the matrix equation produces the algebraic generalized eigenvalue problem: ( [ K ] − ω 2 [ M ] ) u = 0 ([K] - \omega^2 [M]) \mathbf{u} = \mathbf{0} ([ K ] − ω 2 [ M ]) u = 0
The Characteristic Equation & Eigenvalues
For non-trivial eigenvector solutions ( u ≠ 0 \mathbf{u} \ne \mathbf{0} u = 0 ), the characteristic determinant must equal zero: det ( [ K ] − ω 2 [ M ] ) = 0 \det([K] - \omega^2 [M]) = 0 det ([ K ] − ω 2 [ M ]) = 0
For a two-degree-of-freedom (2-DOF) system: det [ k 11 − ω 2 m 11 k 12 − ω 2 m 12 k 21 − ω 2 m 21 k 22 − ω 2 m 22 ] = 0 \det \begin{bmatrix} k_{11} - \omega^2 m_{11} & k_{12} - \omega^2 m_{12} \\ k_{21} - \omega^2 m_{21} & k_{22} - \omega^2 m_{22} \end{bmatrix} = 0 det [ k 11 − ω 2 m 11 k 21 − ω 2 m 21 k 12 − ω 2 m 12 k 22 − ω 2 m 22 ] = 0
Expanding this determinant yields a quadratic equation in λ = ω 2 \lambda = \omega^2 λ = ω 2 (the characteristic polynomial). Solving gives two roots: ω 1 2 \omega_1^2 ω 1 2 and ω 2 2 \omega_2^2 ω 2 2 :
ω 1 \omega_1 ω 1 : First (fundamental) circular natural frequency.
ω 2 \omega_2 ω 2 : Second circular natural frequency ( ω 2 > ω 1 \omega_2 > \omega_1 ω 2 > ω 1 ).
Mode Shapes (Eigenvectors) and Orthogonality
Substituting each natural frequency ω r \omega_r ω r back into ( [ K ] − ω r 2 [ M ] ) u ( r ) = 0 ([K] - \omega_r^2 [M]) \mathbf{u}^{(r)} = \mathbf{0} ([ K ] − ω r 2 [ M ]) u ( r ) = 0 yields the corresponding mode shape vector u ( r ) \mathbf{u}^{(r)} u ( r ) :
Mode 1 ( ω 1 \,\omega_1\, ω 1 ) : Masses vibrate in-phase with one another (no internal node between masses).
Mode 2 ( ω 2 \,\omega_2\, ω 2 ) : Masses vibrate out-of-phase with one another (a stationary nodal point exists between masses).
Mode shapes satisfy mass-orthogonality and stiffness-orthogonality: u ( 1 ) T [ M ] u ( 2 ) = 0 , u ( 1 ) T [ K ] u ( 2 ) = 0 \mathbf{u}^{(1)T} [M] \mathbf{u}^{(2)} = 0, \qquad \mathbf{u}^{(1)T} [K] \mathbf{u}^{(2)} = 0 u ( 1 ) T [ M ] u ( 2 ) = 0 , u ( 1 ) T [ K ] u ( 2 ) = 0
The Dynamic Vibration Absorber (Tuned Mass Damper - TMD)
When a primary machine structure of mass M M M and stiffness K K K is excited by a harmonic force F ( t ) = F 0 sin ( Ω t ) F(t) = F_0 \sin(\Omega t) F ( t ) = F 0 sin ( Ω t ) operating at or near its resonance frequency ω n = K / M \omega_n = \sqrt{K/M} ω n = K / M , excessive vibration occurs. A dynamic vibration absorber attaches an auxiliary mass m a m_a m a and spring k a k_a k a directly to the primary mass. Tuned Mass Damper (TMD) Architecture
- +--------------------------------------------+
- | Primary Machine: Mass M, Stiffness K | ---> F_0 sin(Omega*t)
- +---------------------+----------------------+
- |
- [k_a] (Auxiliary Spring)
- |
- v
- +-----------+
- | Mass(m_a) | (Auxiliary Absorber Mass)
- +-----------+
The undamped coupled equations of motion are: M x ¨ 1 + ( K + k a ) x 1 − k a x 2 = F 0 sin ( Ω t ) M \ddot{x}_1 + (K + k_a) x_1 - k_a x_2 = F_0 \sin(\Omega t) M x ¨ 1 + ( K + k a ) x 1 − k a x 2 = F 0 sin ( Ω t ) m a x ¨ 2 + k a ( x 2 − x 1 ) = 0 m_a \ddot{x}_2 + k_a (x_2 - x_1) = 0 m a x ¨ 2 + k a ( x 2 − x 1 ) = 0
Solving for the steady-state harmonic amplitudes x 1 ( t ) = X 1 sin ( Ω t ) x_1(t) = X_1 \sin(\Omega t) x 1 ( t ) = X 1 sin ( Ω t ) and x 2 ( t ) = X 2 sin ( Ω t ) x_2(t) = X_2 \sin(\Omega t) x 2 ( t ) = X 2 sin ( Ω t ) : X 1 = F 0 ( k a − m a Ω 2 ) ( K + k a − M Ω 2 ) ( k a − m a Ω 2 ) − k a 2 X_1 = \frac{F_0 (k_a - m_a \Omega^2)}{(K + k_a - M \Omega^2)(k_a - m_a \Omega^2) - k_a^2} X 1 = ( K + k a − M Ω 2 ) ( k a − m a Ω 2 ) − k a 2 F 0 ( k a − m a Ω 2 ) X 2 = F 0 k a ( K + k a − M Ω 2 ) ( k a − m a Ω 2 ) − k a 2 X_2 = \frac{F_0 k_a}{(K + k_a - M \Omega^2)(k_a - m_a \Omega^2) - k_a^2} X 2 = ( K + k a − M Ω 2 ) ( k a − m a Ω 2 ) − k a 2 F 0 k a
The Tuning Condition
Examining the numerator of X 1 X_1 X 1 , the motion of the primary mass becomes identically zero ( X 1 = 0 X_1 = 0 X 1 = 0 ) when the numerator vanishes: k a − m a Ω 2 = 0 ⟹ ω a = k a m a = Ω k_a - m_a \Omega^2 = 0 \implies \omega_a = \sqrt{\frac{k_a}{m_a}} = \Omega k a − m a Ω 2 = 0 ⟹ ω a = m a k a = Ω
When the absorber's natural frequency ω a \omega_a ω a is tuned exactly to the excitation frequency Ω \Omega Ω :
The primary mass M M M is completely stationary ( X 1 = 0 X_1 = 0 X 1 = 0 ).
The auxiliary spring exerts an oscillating force − k a X 2 -k_a X_2 − k a X 2 that is exactly equal in magnitude and opposite in phase to the applied external force F 0 F_0 F 0 : X 2 = − F 0 k a X_2 = -\frac{F_0}{k_a} X 2 = − k a F 0
Operational Limitation
Attaching the absorber converts the original 1-DOF system into a 2-DOF system. While it neutralizes vibration at Ω \Omega Ω , it introduces two new resonant frequencies: one below Ω \Omega Ω and one above Ω \Omega Ω . Therefore, an undamped TMD is suitable only for constant-speed machinery. If excitation frequency drifts, the machine operates on one of the new resonance peaks unless damping is added to the absorber (creating a damped Tuned Mass Damper).
- Step-by-Step Worked Vibration Isolation Design Problem
- Problem Statement
A rooftop industrial HVAC compressor package has a total operating mass M = 1 , 200 kg M = 1,\!200\,\text{kg} M = 1 , 200 kg . The compressor operates at a constant running speed N = 1 , 800 rpm N = 1,\!800\,\text{rpm} N = 1 , 800 rpm . Structural criteria require that the vibration isolation system achieve a minimum isolation efficiency of 88 % 88\% 88% (transmissibility T R ≤ 0.12 TR \le 0.12 TR ≤ 0.12 ) transmitted to the building concrete floor slab. The selected isolators provide a damping ratio ζ = 0.05 \zeta = 0.05 ζ = 0.05 .
Calculate:
The operating circular frequency ω \omega ω .
The minimum required frequency ratio r r r to satisfy T R = 0.12 TR = 0.12 TR = 0.12 .
The maximum permissible system natural frequency ω n \omega_n ω n and cyclic natural frequency f n f_n f n .
The required static deflection δ s t \delta_{st} δ s t of the mounts under the machine's static weight.
The total required mounting stiffness K tot K_{\text{tot}} K tot , and the stiffness k i k_i k i for each of four identical corner isolator mounts.
The appropriate isolator medium selection.
- Step-by-Step Solution
- Step 1: Compressor Operating Frequency
Convert running speed from rpm to radians per second: ω = 2 π N 60 = 2 π × 1 , 800 60 = 60 π ≈ 188.50 rad/s \omega = \frac{2\pi N}{60} = \frac{2\pi \times 1,\!800}{60} = 60\pi \approx 188.50\,\text{rad/s} ω = 60 2 π N = 60 2 π × 1 , 800 = 60 π ≈ 188.50 rad/s f operating = 1 , 800 60 = 30.0 Hz f_{\text{operating}} = \frac{1,\!800}{60} = 30.0\,\text{Hz} f operating = 60 1 , 800 = 30.0 Hz
Step 2: Determine Required Frequency Ratio ( r r r )
The transmissibility equation is: T R = 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 TR = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}} TR = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2
Squaring both sides with T R = 0.12 TR = 0.12 TR = 0.12 and ζ = 0.05 \zeta = 0.05 ζ = 0.05 : ( 0.12 ) 2 = 1 + [ 2 ( 0.05 ) r ] 2 ( 1 − r 2 ) 2 + [ 2 ( 0.05 ) r ] 2 ⟹ 0.0144 = 1 + 0.01 r 2 ( 1 − r 2 ) 2 + 0.01 r 2 (0.12)^2 = \frac{1 + [2(0.05) r]^2}{(1 - r^2)^2 + [2(0.05) r]^2} \implies 0.0144 = \frac{1 + 0.01 r^2}{(1 - r^2)^2 + 0.01 r^2} ( 0.12 ) 2 = ( 1 − r 2 ) 2 + [ 2 ( 0.05 ) r ] 2 1 + [ 2 ( 0.05 ) r ] 2 ⟹ 0.0144 = ( 1 − r 2 ) 2 + 0.01 r 2 1 + 0.01 r 2
Letting u = r 2 u = r^2 u = r 2 : 0.0144 [ ( 1 − u ) 2 + 0.01 u ] = 1 + 0.01 u 0.0144 \left[(1 - u)^2 + 0.01 u\right] = 1 + 0.01 u 0.0144 [ ( 1 − u ) 2 + 0.01 u ] = 1 + 0.01 u 0.0144 [ u 2 − 2 u + 1 + 0.01 u ] = 1 + 0.01 u 0.0144 \left[u^2 - 2u + 1 + 0.01 u\right] = 1 + 0.01 u 0.0144 [ u 2 − 2 u + 1 + 0.01 u ] = 1 + 0.01 u 0.0144 [ u 2 − 1.99 u + 1 ] = 1 + 0.01 u 0.0144 \left[u^2 - 1.99 u + 1\right] = 1 + 0.01 u 0.0144 [ u 2 − 1.99 u + 1 ] = 1 + 0.01 u 0.0144 u 2 − 0.028656 u + 0.0144 = 1 + 0.01 u 0.0144 u^2 - 0.028656 u + 0.0144 = 1 + 0.01 u 0.0144 u 2 − 0.028656 u + 0.0144 = 1 + 0.01 u 0.0144 u 2 − 0.038656 u − 0.9856 = 0 0.0144 u^2 - 0.038656 u - 0.9856 = 0 0.0144 u 2 − 0.038656 u − 0.9856 = 0
Dividing through by 0.0144 0.0144 0.0144 : u 2 − 2.6844 u − 68.444 = 0 u^2 - 2.6844 u - 68.444 = 0 u 2 − 2.6844 u − 68.444 = 0
Applying the quadratic formula: u = 2.6844 + ( − 2.6844 ) 2 − 4 ( 1 ) ( − 68.444 ) 2 = 2.6844 + 7.206 + 273.778 2 = 2.6844 + 16.763 2 = 9.724 u = \frac{2.6844 + \sqrt{(-2.6844)^2 - 4(1)(-68.444)}}{2} = \frac{2.6844 + \sqrt{7.206 + 273.778}}{2} = \frac{2.6844 + 16.763}{2} = 9.724 u = 2 2.6844 + ( − 2.6844 ) 2 − 4 ( 1 ) ( − 68.444 ) = 2 2.6844 + 7.206 + 273.778 = 2 2.6844 + 16.763 = 9.724
Since u = r 2 u = r^2 u = r 2 : r = 9.724 ≈ 3.118 r = \sqrt{9.724} \approx 3.118 r = 9.724 ≈ 3.118
(Note: Using the undamped approximation T R ≈ 1 / ( r 2 − 1 ) TR \approx 1/(r^2 - 1) TR ≈ 1/ ( r 2 − 1 ) gives r 2 − 1 = 1 / 0.12 = 8.333 ⟹ r = 9.333 = 3.055 r^2 - 1 = 1/0.12 = 8.333 \implies r = \sqrt{9.333} = 3.055 r 2 − 1 = 1/0.12 = 8.333 ⟹ r = 9.333 = 3.055 . Exact solution with damping yields r = 3.118 r = 3.118 r = 3.118 .)
Step 3: Maximum Allowable Natural Frequency
To maintain r ≥ 3.118 r \ge 3.118 r ≥ 3.118 : ω n = ω r = 188.50 rad/s 3.118 = 60.455 rad/s \omega_n = \frac{\omega}{r} = \frac{188.50\,\text{rad/s}}{3.118} = 60.455\,\text{rad/s} ω n = r ω = 3.118 188.50 rad/s = 60.455 rad/s f n = ω n 2 π = 60.455 2 π ≈ 9.62 Hz f_n = \frac{\omega_n}{2\pi} = \frac{60.455}{2\pi} \approx 9.62\,\text{Hz} f n = 2 π ω n = 2 π 60.455 ≈ 9.62 Hz
The mounting system natural frequency must not exceed 9.62 Hz 9.62\,\text{Hz} 9.62 Hz .
Step 4: Required Static Deflection
Using the gravitational static deflection relation ( g = 9.81 m/s 2 g = 9.81\,\text{m/s}^2 g = 9.81 m/s 2 ): δ s t = g ω n 2 = 9.81 m/s 2 ( 60.455 rad/s ) 2 = 9.81 3 , 654.8 = 0.002684 m = 2.68 mm ( ≈ 0.106 in ) \delta_{st} = \frac{g}{\omega_n^2} = \frac{9.81\,\text{m/s}^2}{(60.455\,\text{rad/s})^2} = \frac{9.81}{3,\!654.8} = 0.002684\,\text{m} = 2.68\,\text{mm} \quad (\approx 0.106\,\text{in}) δ s t = ω n 2 g = ( 60.455 rad/s ) 2 9.81 m/s 2 = 3 , 654.8 9.81 = 0.002684 m = 2.68 mm ( ≈ 0.106 in )
Step 5: Required Mounting Stiffness
The total system stiffness is: K tot = M ω n 2 = 1 , 200 kg × 3 , 654.8 rad 2 / s 2 = 4 , 385 , 800 N/m = 4.386 MN/m K_{\text{tot}} = M \omega_n^2 = 1,\!200\,\text{kg} \times 3,\!654.8\,\text{rad}^2/\text{s}^2 = 4,\!385,\!800\,\text{N/m} = 4.386\,\text{MN/m} K tot = M ω n 2 = 1 , 200 kg × 3 , 654.8 rad 2 / s 2 = 4 , 385 , 800 N/m = 4.386 MN/m
For four identical corner mounts supporting the load equally in parallel: k i = K tot 4 = 4 , 385 , 800 N/m 4 = 1 , 096 , 450 N/m ≈ 1 , 096 kN/m = 1 , 096 N/mm k_i = \frac{K_{\text{tot}}}{4} = \frac{4,\!385,\!800\,\text{N/m}}{4} = 1,\!096,\!450\,\text{N/m} \approx 1,\!096\,\text{kN/m} = 1,\!096\,\text{N/mm} k i = 4 K tot = 4 4 , 385 , 800 N/m = 1 , 096 , 450 N/m ≈ 1 , 096 kN/m = 1 , 096 N/mm
Step 6: Isolator Selection Analysis
The required static deflection is δ s t = 2.68 mm \delta_{st} = 2.68\,\text{mm} δ s t = 2.68 mm with a natural frequency f n = 9.62 Hz f_n = 9.62\,\text{Hz} f n = 9.62 Hz . Consulting the isolator selection table:
Elastomeric (neoprene) shear mounts easily support deflections up to 6 − 12 mm 6 - 12\,\text{mm} 6 − 12 mm and natural frequencies in the 7 − 12 Hz 7 - 12\,\text{Hz} 7 − 12 Hz range.
Neoprene isolators provide the required internal damping ζ ≈ 0.05 \zeta \approx 0.05 ζ ≈ 0.05 without acoustic ringing.
Steel springs are unnecessary because the required deflection does not demand large spring travels (> 25 mm 25\,\text{mm} 25 mm ).
Final Engineering Specification : Install four commercial elastomeric (neoprene-in-shear) vibration isolators, each rated for k i = 1 , 096 kN/m k_i = 1,\!096\,\text{kN/m} k i = 1 , 096 kN/m ( 6 , 260 lbf/in 6,\!260\,\text{lbf/in} 6 , 260 lbf/in ) with a rated static load of 300 kg 300\,\text{kg} 300 kg ( 2 , 943 N 2,\!943\,\text{N} 2 , 943 N ) each.