Study guide
13.2 Basic Mechatronics, Sensors & Closed-Loop Controls
PE Mechanical: Machine Design and Materials Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Basic Engineering Practice: Drawings, Economics & Design Methodology
1.1 Engineering Terms, Symbols, Drawing Interpretation & Conventions 1.2 Project Management & Engineering Economics 1.3 Design Methodology, Risk Assessment & Safety
2 Chapter 2: Physical & Mechanical Properties of Engineering Materials
2.1 Stress-Strain Relationships & Fundamental Mechanical Properties 2.2 Physical Properties, Temperature Effects, Hardness, Impact Toughness & Creep
3 Chapter 3: Mechanics of Materials: Fundamental Loadings & Deflections
3.1 Axial Loading, Normal Stress & Statically Indeterminate Members 3.2 Direct Shear, Bearing & Transverse Shear in Beams 3.3 Torsion of Shafts, Power Transmission & Thin-Walled Tubes 3.4 Beam Bending Stresses & Deflection Analysis
4 Chapter 4: Mechanics of Materials: Stability, Multiaxial Stress & Thermal Effects
4.1 Column Buckling & Elastic/Inelastic Instability 4.2 Combined Loading, Principal Stresses & Mohr's Circle 4.3 Thermal Stresses & Interference Stresses
5 Chapter 5: Failure Theories: Static Yielding & Fracture Mechanics
5.1 Static Failure Theories for Ductile Materials: von Mises & Tresca 5.2 Static Failure Theories for Brittle Materials & Fracture Mechanics
6 Chapter 6: Fatigue Analysis & Dynamic Failure
6.1 High-Cycle Fatigue, S-N Curves & Marin Modifying Factors 6.2 Fluctuating Stresses, Failure Criteria & Cumulative Damage
7 Chapter 7: Mechanical Attachments: Fasteners & Bolted Joints
7.1 Threaded Fasteners, Proof Strength & Preload Mechanics 7.2 Bolted Joint Stiffness, External Loading & Separation 7.3 Non-Threaded Fasteners: Keys, Pins, Clevises, Retaining Rings, Rivets, Lugs & Anchors
8 Chapter 8: Mechanical Attachments: Permanent Joints & Bonding
8.1 Welded Joints & Weld Group Stress Analysis 8.2 Brazing, Soldering & Structural Adhesive Bonding
9 Chapter 9: Power Transmission: Shafts & Gearing
9.1 Transmission Shaft Design, Critical Speeds & Deflection 9.2 Spur Gears: Geometry, Kinematics & AGMA Stress Equations 9.3 Helical, Bevel & Worm Gearing
10 Chapter 10: Power Transmission: Bearings, Flexible Drives, Friction Devices & Prime Movers
10.1 Rolling-Element Bearings & L10 Life Calculations 10.2 Hydrodynamic Journal Bearings & Lubrication Regimes 10.3 Belts, Roller Chains & Flexible Drives 10.4 Clutches, Brakes & Power Screws 10.5 Electric Motors, Engines & Flywheels
11 Chapter 11: Mechanical Components: Pressure Vessels & Structural Systems
11.1 Pressure Vessels & Piping: Thin and Thick Walls, ASME VIII and B31 11.2 Mechanical Springs: Helical, Belleville & Leaf Springs 11.3 Structural Trusses, Rigid Frames & Energy Methods
12 Chapter 12: Mechanical Dynamics, Vibrations & Fluid Power
12.1 Single-Degree-of-Freedom Vibrations & Resonance 12.2 Vibration Isolation, Multi-DOF Systems & Transmissibility 12.3 Fluid Power Systems: Hydraulics & Pneumatics
13 Chapter 13: Kinematics, Mechatronics & Control Systems
13.1 Mechanism Kinematics, Linkages, Cams & Simple Machines 13.2 Basic Mechatronics, Sensors & Closed-Loop Controls
14 Chapter 14: Supportive Knowledge: Fits, Tolerances & Manufacturing Methods
14.1 Limits, Fits & Geometric Dimensioning & Tolerancing (GD&T) 14.2 Manufacturing Methods, Machinability, Heat Treatment & Assembly
15 Chapter 15: Supportive Knowledge: Codes, Computation, Testing & Corrosion
15.1 Engineering Codes & Standards 15.2 Computational Methods: FEA & Numerical Analysis 15.3 Instrumentation, Testing, Inspection & Quality 15.4 Chemical Processes: Corrosion, Oxidation & Embrittlement
13.2 Basic Mechatronics, Sensors & Closed-Loop Controls
Key Takeaways Explain This Topic AI
Resistive strain gages quantify mechanical strain via Δ R R = G F ⋅ ϵ \frac{\Delta R}{R} = GF \cdot \epsilon R Δ R = GF ⋅ ϵ ; configured in a full Wheatstone bridge with four active gages, output voltage quadruples ( V o u t = V s ⋅ G F ⋅ ϵ V_{out} = V_s \cdot GF \cdot \epsilon V o u t = V s ⋅ GF ⋅ ϵ ), maximizing sensitivity while inherently canceling thermal expansion and bending/axial crosstalk.
Incremental optical encoders generate quadrature pulse trains (channels A and B shifted by 90 ∘ 90^\circ 9 0 ∘ electrical) enabling 4 × 4\times 4 × edge-count resolution multiplication and direction sensing, whereas absolute encoders utilize Gray code tracks to prevent multi-bit transition errors during dynamic reading.
Brushed and brushless DC motors exhibit a linear inverse torque-speed relationship ω ( T ) = ω n l ( 1 − T / T s t a l l ) \omega(T) = \omega_{nl}(1 - T/T_{stall}) ω ( T ) = ω n l ( 1 − T / T s t a ll ) , producing peak mechanical output power at exactly half the stall torque and half the no-load speed ( P max = 1 4 T s t a l l ω n l P_{\max} = \frac{1}{4} T_{stall} \omega_{nl} P m a x = 4 1 T s t a ll ω n l ).
In PID control architectures, proportional gain K p K_p K p reduces rise time and steady-state error, integral gain K i K_i K i eliminates steady-state offset ( e s s → 0 e_{ss} \to 0 e ss → 0 ) by increasing system type at the expense of phase lag and overshoot, and derivative gain K d K_d K d introduces phase lead to dampen transient oscillations.
Closed-loop system stability requires all roots of the characteristic equation 1 + C ( s ) G ( s ) = 0 1 + C(s)G(s) = 0 1 + C ( s ) G ( s ) = 0 to lie strictly within the open left-half complex plane ( Re ( s ) < 0 \text{Re}(s) < 0 Re ( s ) < 0 ), verifiable algebraically via the Routh-Hurwitz stability criterion without factoring high-order polynomials.
Last updated: October 2026
13.2 Basic Mechatronics, Sensors & Closed-Loop Controls
Modern mechanical systems are rarely purely mechanical; they are integrated mechatronic systems that combine precision mechanisms, sensors, electronic signal conditioning, embedded digital processors, and electromechanical actuators. For machine designers, understanding how physical quantities (force, strain, displacement, temperature, and speed) are measured, converted into electrical signals, and regulated by feedback controllers is essential for designing automated machinery, robotic arms, precision positioning stages, and dynamic test equipment.
- Mechatronic System Architecture & Signal Conditioning
- A complete mechatronic control system functions as a closed information loop: Mechatronic Control Loop
- Reference + Error +------------+ Control +----------+
- r(t) ------------>(+)----------> | Controller | --------> | Actuator |
- (Setpoint) ^ - e(t) | (DSP/PLC) | u(t) | Driver |
- | +------------+ +----------+
- | |
- | +-----------------------+ v
- | | Mechanical Plant | <--------------+
- | | (Mechanism / Load) | Driven |
- | +-----------------------+ Motion |
- | | |
- | v |
- | +-------------------+ |
- +------------ | Sensor / Signal | <----------------+
- Measurement | Conditioning | Process Feedback
- y(t) +-------------------+
- Signal Conditioning & Interfacing Fundamentals
Amplification & Common-Mode Rejection :
Sensors frequently output low-level differential voltages ( 1 mV − 50 mV 1\,\text{mV} - 50\,\text{mV} 1 mV − 50 mV ). Differential instrumentation amplifiers provide high input impedance and a high Common-Mode Rejection Ratio (CMRR) to amplify microvolt sensor signals while rejecting 60 Hz electrical mains noise and electromagnetic interference (EMI).
Anti-Aliasing Filtering & Sampling (Nyquist Criterion) :
Analog signals must be converted to digital numbers via an Analog-to-Digital Converter (ADC). To prevent aliasing (where high-frequency noise folds back into the measurement band as false low-frequency signals), an analog low-pass anti-aliasing filter must precede the ADC.
By the Nyquist-Shannon sampling theorem , the sampling frequency f s f_s f s must exceed at least twice the maximum frequency component present in the analog signal: f s ≥ 2 f max f_s \ge 2 f_{\max} f s ≥ 2 f m a x
In practical machine control systems, f s f_s f s is commonly set to 10 × 10 \times 10 × to 20 × 20 \times 20 × the closed-loop system bandwidth.
ADC Resolution & Quantization Error :
An N N N -bit ADC with an input voltage range V ref V_{\text{ref}} V ref divides the signal into 2 N 2^N 2 N discrete digital levels. The voltage resolution (quantization step size Q Q Q ) is: Q = V ref 2 N Q = \frac{V_{\text{ref}}}{2^N} Q = 2 N V ref
The maximum quantization error is ± Q 2 \pm \frac{Q}{2} ± 2 Q . For example, a 16-bit ADC operating over a 0 − 10 V 0-10\,\text{V} 0 − 10 V range has Q = 10 65 , 536 ≈ 0.153 mV Q = \frac{10}{65,\!536} \approx 0.153\,\text{mV} Q = 65 , 536 10 ≈ 0.153 mV .
- Sensors & Transducers
- 1. Resistive Strain Gages & Wheatstone Bridges
A resistive foil strain gage consists of a thin metallic grid bonded to a flexible backing. When subjected to mechanical strain ϵ \epsilon ϵ , its electrical resistance changes proportionally due to physical elongation and piezoresistive effects: Δ R R = G F ⋅ ϵ \frac{\Delta R}{R} = GF \cdot \epsilon R Δ R = GF ⋅ ϵ
where:
R R R = nominal gage resistance (commonly 120 Ω , 350 Ω , or 1 , 000 Ω 120\,\Omega, 350\,\Omega, \text{or } 1,\!000\,\Omega 120 Ω , 350 Ω , or 1 , 000 Ω ).
ϵ = Δ L L \epsilon = \frac{\Delta L}{L} ϵ = L Δ L = engineering strain (dimensionless, commonly expressed in microstrain μ ε = 10 − 6 \mu\varepsilon = 10^{-6} μ ε = 1 0 − 6 ).
G F GF GF = Gage Factor (dimensionless sensitivity factor; typically G F ≈ 2.0 − 2.1 GF \approx 2.0 - 2.1 GF ≈ 2.0 − 2.1 for metallic constantan foil gages, and G F ≈ 100 − 150 GF \approx 100 - 150 GF ≈ 100 − 150 for semiconductor silicon gages). Wheatstone Bridge Circuit
- (+) V_s (Excitation)
- *
- / \
- R_1 (Arm 1)/ \ R_2 (Arm 2)
- / \
- *-------*
- (-) V_out (+)
- \ /
- R_4 (Arm 4)\ / R_3 (Arm 3)
- \ /
- *
- GND
- Wheatstone Bridge Circuit Formulations
Because Δ R / R \Delta R / R Δ R / R is tiny (typically < 0.1 % < 0.1\% < 0.1% ), a Wheatstone bridge converts small fractional resistance changes into measurable differential voltages V out V_{\text{out}} V out . The general balanced bridge relation is R 1 R 3 = R 2 R 4 R_1 R_3 = R_2 R_4 R 1 R 3 = R 2 R 4 . For small variations, the bridge output is: V out V s ≈ 1 4 ( Δ R 1 R 1 − Δ R 2 R 2 + Δ R 3 R 3 − Δ R 4 R 4 ) = G F 4 ( ϵ 1 − ϵ 2 + ϵ 3 − ϵ 4 ) \frac{V_{\text{out}}}{V_s} \approx \frac{1}{4} \left( \frac{\Delta R_1}{R_1} - \frac{\Delta R_2}{R_2} + \frac{\Delta R_3}{R_3} - \frac{\Delta R_4}{R_4} \right) = \frac{GF}{4} (\epsilon_1 - \epsilon_2 + \epsilon_3 - \epsilon_4) V s V out ≈ 4 1 ( R 1 Δ R 1 − R 2 Δ R 2 + R 3 Δ R 3 − R 4 Δ R 4 ) = 4 GF ( ϵ 1 − ϵ 2 + ϵ 3 − ϵ 4 )
Quarter-Bridge (1 active gage in arm 1, 3 fixed resistors): V out = V s G F ⋅ ϵ 4 V_{\text{out}} = V_s \frac{GF \cdot \epsilon}{4} V out = V s 4 GF ⋅ ϵ
Susceptible to thermal drift because temperature changes cause thermal resistance changes that mimic mechanical strain. A dummy unstrained gage in arm 2 exposed to the same ambient temperature cancels temperature drift.
Half-Bridge (2 active gages):
Bending Application : Gage 1 mounted on top surface in tension ( + ϵ +\epsilon + ϵ ), Gage 2 on bottom surface in compression ( − ϵ -\epsilon − ϵ ): V out = V s G F 4 [ ( ϵ ) − ( − ϵ ) ] = V s G F ⋅ ϵ 2 V_{\text{out}} = V_s \frac{GF}{4} [(\epsilon) - (-\epsilon)] = V_s \frac{GF \cdot \epsilon}{2} V out = V s 4 GF [( ϵ ) − ( − ϵ )] = V s 2 GF ⋅ ϵ Doubles sensitivity, and inherently cancels both axial tension/compression and thermal expansion.
Full-Bridge (4 active gages):
Bending Beam : Gages 1 and 3 in tension ( + ϵ +\epsilon + ϵ ), Gages 2 and 4 in compression ( − ϵ -\epsilon − ϵ ): V out = V s G F 4 [ ( ϵ ) − ( − ϵ ) + ( ϵ ) − ( − ϵ ) ] = V s ⋅ G F ⋅ ϵ V_{\text{out}} = V_s \frac{GF}{4} [(\epsilon) - (-\epsilon) + (\epsilon) - (-\epsilon)] = V_s \cdot GF \cdot \epsilon V out = V s 4 GF [( ϵ ) − ( − ϵ ) + ( ϵ ) − ( − ϵ )] = V s ⋅ GF ⋅ ϵ Quadruples output sensitivity, completely rejects temperature drift, cancels axial loads, and provides maximum signal-to-noise ratio.
2. Linear Variable Differential Transformers (LVDTs)
An LVDT is an electromechanical transducer that produces an electrical output proportional to linear displacement:
Construction : One primary coil centered between two identical secondary coils wound in series-opposition around a cylindrical hollow bobbin. A moveable high-permeability ferromagnetic core attaches to the moving machine member.
Operation : The primary coil is excited with an AC carrier voltage ( 1 − 10 kHz 1-10\,\text{kHz} 1 − 10 kHz , 3 − 15 V rms 3-15\,\text{V}_{\text{rms}} 3 − 15 V rms ). When the core is centered at the null position , equal magnetic flux links both secondary coils; because they are wired in series-opposition, the net output voltage is zero ( V out = V s 1 − V s 2 = 0 V_{\text{out}} = V_{s1} - V_{s2} = 0 V out = V s 1 − V s 2 = 0 ).
Displacement : Moving the core from null increases flux in one secondary while decreasing flux in the other. The amplitude of V out V_{\text{out}} V out scales linearly with core displacement, while its phase ( 0 ∘ 0^\circ 0 ∘ vs 180 ∘ 180^\circ 18 0 ∘ relative to primary excitation) indicates direction.
Features : Frictionless non-contact operation, infinite theoretical resolution, high linearity ( < 0.25 % < 0.25\% < 0.25% ), and rugged resistance to shock, vibration, and contaminated environments.
3. Optical Encoders (Incremental vs. Absolute)
Optical encoders convert rotational displacement into digital pulses using a patterned glass or polymer disc and photodetectors.
Incremental Encoders :
Utilize two optical tracks: Channel A and Channel B, offset by 90 ∘ 90^\circ 9 0 ∘ electrical phase ( quadrature ).
Direction Sensing : If Channel A leads Channel B, shaft rotation is clockwise; if B leads A, rotation is counterclockwise.
Resolution Multiplication ( 4 × 4\times 4 × Decoding) : By counting both rising and falling edges of channels A and B, the effective resolution is quadrupled ( 4 × PPR 4 \times \text{PPR} 4 × PPR pulses per revolution).
Index Channel (Z) : Produces one pulse per complete revolution, serving as a physical reference marker for homing.
Limitation : Loses absolute shaft position upon loss of power; requires a homing routine on power-up.
Absolute Encoders :
Disc features multiple concentric tracks, where each angular sector corresponds to a unique digital binary word.
Retains absolute position even during power outages; no homing sequence required.
Gray Code vs. Binary : In natural binary code, transitioning between consecutive numbers often requires multiple bits to flip simultaneously (e.g., 011 2 → 100 2 011_2 \to 100_2 01 1 2 → 10 0 2 flips all 3 bits). Slight mechanical disc misalignment causes intermediate read glitches (e.g., momentarily reading 111 2 111_2 11 1 2 ). Gray code is a reflected binary code designed so that only one bit changes between any two consecutive values , eliminating transition glitches.
- 4. Temperature Sensors Temperature Sensor Comparison
- +-----------------------------------------------------------------------------------------+
- | Sensor Type | Transduction Principle | Operating Range | Key Characteristic |
- |--------------+---------------------------------+---------------------+--------------------|
- | Thermocouple | Seebeck thermoelectric effect | -200C to +1800C | Rugged, self-power |
- | RTD (Pt100) | Positive temp-coefficient (PTC) | -200C to +650C | High accuracy/line |
- | Thermistor | Negative temp-coefficient (NTC) | -50C to +150C | High sensitivity |
- +-----------------------------------------------------------------------------------------+
Thermocouples :
Two dissimilar metal wires joined at one end form a measuring (hot) junction. The Seebeck effect generates an open-circuit voltage proportional to the temperature difference between hot junction T hot T_{\text{hot}} T hot and reference (cold) junction T ref T_{\text{ref}} T ref : V = S A B ( T hot − T ref ) V = S_{AB}(T_{\text{hot}} - T_{\text{ref}}) V = S A B ( T hot − T ref ) .
Requires Cold-Junction Compensation (CJC) using a local IC temperature sensor on the isothermal terminal block.
Common types: Type K (Chromel-Alumel, wide industrial range − 200 ∘ C -200^\circ\text{C} − 20 0 ∘ C to + 1250 ∘ C +1250^\circ\text{C} + 125 0 ∘ C , ≈ 41 μ V / ∘ C \approx 41\,\mu\text{V}/^\circ\text{C} ≈ 41 μ V / ∘ C ), Type J (Iron-Constantan), Type T (Copper-Constantan).
Resistance Temperature Detectors (RTDs) :
Operating principle: Pure metals exhibit a linear increase in electrical resistance with temperature: R ( T ) = R 0 [ 1 + α ( T − T 0 ) ] R(T) = R_0 [1 + \alpha(T - T_0)] R ( T ) = R 0 [ 1 + α ( T − T 0 )]
Industrial standard: Pt100 ( R 0 = 100.0 Ω R_0 = 100.0\,\Omega R 0 = 100.0 Ω at 0 ∘ C 0^\circ\text{C} 0 ∘ C , α = 0.00385 Ω / Ω / ∘ C \alpha = 0.00385\,\Omega/\Omega/^\circ\text{C} α = 0.00385 Ω/Ω / ∘ C ) and Pt1000 ( 1 , 000 Ω 1,\!000\,\Omega 1 , 000 Ω at 0 ∘ C 0^\circ\text{C} 0 ∘ C ).
Highly linear, stable, and accurate ( ± 0.1 ∘ C \pm 0.1^\circ\text{C} ± 0. 1 ∘ C ). 3-wire and 4-wire lead configurations cancel lead-wire resistance in remote installations.
Thermistors :
Semiconductor metal oxides with a Negative Temperature Coefficient (NTC): R ( T ) = R 0 exp [ β ( 1 T − 1 T 0 ) ] R(T) = R_0 \exp\left[ \beta \left(\frac{1}{T} - \frac{1}{T_0}\right) \right] R ( T ) = R 0 exp [ β ( T 1 − T 0 1 ) ]
Extremely sensitive to small temperature changes over narrow ranges, but highly non-linear.
Basic Circuit Relations for Mechatronics
Sensor, actuator and controller hardware rests on a few circuit relations:
Ohm's law and power : V = I R V = IR V = I R ; P = V I = I 2 R = V 2 / R P = VI = I^2 R = V^2/R P = V I = I 2 R = V 2 / R .
Series and parallel resistors : R e q = R 1 + R 2 + … R_{eq} = R_1 + R_2 + \dots R e q = R 1 + R 2 + … in series; 1 / R e q = 1 / R 1 + 1 / R 2 + … 1/R_{eq} = 1/R_1 + 1/R_2 + \dots 1/ R e q = 1/ R 1 + 1/ R 2 + … in parallel.
Voltage divider : V out = V in R 2 / ( R 1 + R 2 ) V_{\text{out}} = V_{\text{in}} R_2/(R_1 + R_2) V out = V in R 2 / ( R 1 + R 2 ) , used to scale signals and in potentiometer position sensors.
RC circuits : time constant τ = R C \tau = RC τ = RC ; a capacitor charges to 63.2 % 63.2\% 63.2% of its final voltage in one τ \tau τ and about 99 % 99\% 99% in 5 τ 5\tau 5 τ . A first-order RC low-pass filter has cutoff frequency f c = 1 / ( 2 π R C ) f_c = 1/(2\pi R C) f c = 1/ ( 2 π RC ) and is the simplest anti-aliasing filter.
RL circuits : τ = L / R \tau = L/R τ = L / R . Current in solenoids and motor windings rises with this time constant, which is why stepper torque falls at high step rates.
Inductive loads (relays, solenoids, motor windings) produce a large voltage spike ( V = L d i / d t V = L\,di/dt V = L d i / d t ) when switched off, so a flyback (freewheeling) diode is placed across the coil to protect the switching transistor.
Switching and drive circuits : transistors and MOSFETs let low-power logic switch loads; an H-bridge of four switches reverses a DC motor; pulse-width modulation (PWM) sets the average voltage V avg = D V supply V_{\text{avg}} = D\,V_{\text{supply}} V avg = D V supply for duty cycle D D D . Relays, contactors and solid-state relays interface controller outputs with motors and heaters.
Mini-example: A 10 k Ω 10\,\text{k}\Omega 10 k Ω resistor and a 0.1 μ F 0.1\,\mu\text{F} 0.1 μ F capacitor give τ = R C = 1 ms \tau = RC = 1\,\text{ms} τ = RC = 1 ms and f c = 1 / ( 2 π × 10,000 × 0.1 × 10 − 6 ) = 159 Hz f_c = 1/(2\pi \times 10{,}000 \times 0.1 \times 10^{-6}) = 159\,\text{Hz} f c = 1/ ( 2 π × 10 , 000 × 0.1 × 1 0 − 6 ) = 159 Hz . A 24 V 24\,\text{V} 24 V supply switched at 40 % 40\% 40% duty cycle delivers an average of 9.6 V 9.6\,\text{V} 9.6 V to a motor.
- Electromechanical Actuators
- 1. DC Motors (Brushed vs. Brushless)
In a direct current (DC) motor, magnetic fields interact to produce torque: V = I a R a + E b = I a R a + K e ω V = I_a R_a + E_b = I_a R_a + K_e \omega V = I a R a + E b = I a R a + K e ω T = K t I a T = K_t I_a T = K t I a
where:
- V V V = applied armature terminal voltage (V)
- I a I_a I a = armature current (A)
- R a R_a R a = armature winding resistance ( Ω \Omega Ω )
- E b = K e ω E_b = K_e \omega E b = K e ω = counter-electromotive force / back-EMF (V)
- ω \omega ω = rotor angular velocity (rad/s)
- K e K_e K e = back-EMF constant ( V ⋅ s/rad \text{V}\cdot\text{s/rad} V ⋅ s/rad )
- K t K_t K t = torque sensitivity constant ( N ⋅ m/A \text{N}\cdot\text{m/A} N ⋅ m/A )
(In consistent SI units, K e = K t K_e = K_t K e = K t numerically).
Torque-Speed Characteristic
Combining the electrical and torque equations yields the linear torque-speed curve for a permanent magnet DC motor: ω ( T ) = V K e − R a K t K e T = ω n l ( 1 − T T stall ) \omega(T) = \frac{V}{K_e} - \frac{R_a}{K_t K_e} T = \omega_{nl} \left(1 - \frac{T}{T_{\text{stall}}}\right) ω ( T ) = K e V − K t K e R a T = ω n l ( 1 − T stall T )
No-Load Speed ( ω n l \omega_{nl} ω n l at T = 0 T = 0 T = 0 ): ω n l = V K e \omega_{nl} = \frac{V}{K_e} ω n l = K e V
Stall Torque ( T stall T_{\text{stall}} T stall at ω = 0 \omega = 0 ω = 0 ): T stall = K t V R a T_{\text{stall}} = \frac{K_t V}{R_a} T stall = R a K t V DC Motor Torque-Speed Curve
- Speed w ^
- w_nl +\
- | \
- | \ Operating Characteristic Curve
- | \
- w_nl/2 +----+----\ <-- Maximum Power Point: P_max
- | | \
- +----+------+---------> Torque T
- 0 T_stall/2 T_stall
- Mechanical Output Power
The mechanical output power is P ( T ) = T ω P(T) = T \omega P ( T ) = T ω : P ( T ) = T ω n l ( 1 − T T stall ) P(T) = T \omega_{nl} \left(1 - \frac{T}{T_{\text{stall}}}\right) P ( T ) = T ω n l ( 1 − T stall T )
Differentiating with respect to T T T and setting to zero demonstrates that maximum mechanical power output occurs at exactly half the stall torque and half the no-load speed : T P max = 1 2 T stall , ω P max = 1 2 ω n l T_{P\max} = \frac{1}{2} T_{\text{stall}}, \qquad \omega_{P\max} = \frac{1}{2} \omega_{nl} T P m a x = 2 1 T stall , ω P m a x = 2 1 ω n l P max = T P max ω P max = 1 4 T stall ω n l = V 2 4 R a P_{\max} = T_{P\max} \omega_{P\max} = \frac{1}{4} T_{\text{stall}} \omega_{nl} = \frac{V^2}{4 R_a} P m a x = T P m a x ω P m a x = 4 1 T stall ω n l = 4 R a V 2
Brushed vs. Brushless DC Motors (BLDC)
Brushed DC : Mechanical commutator rings and graphite brushes continuously reverse armature coil currents. Simple two-lead drive, but subject to brush arcing, wear, acoustic/RF noise, and limited operational life.
Brushless DC (BLDC) : Permanent magnets on rotor, multiphase electromagnetic windings on stator. Electronic inverter commutates currents based on rotor position (Hall effect sensors or sensorless back-EMF sensing). Offers higher efficiency, superior thermal dissipation, higher continuous torque, and virtually maintenance-free operation.
2. Stepper Motors
Stepper motors convert discrete digital pulses into precise incremental shaft rotations without closed-loop feedback.
Step Angle ( θ s \theta_s θ s ): θ s = 360 ∘ 2 m Z \theta_s = \frac{360^\circ}{2\,m\,Z} θ s = 2 m Z 36 0 ∘ for a hybrid stepper driven in full steps, where m m m = number of phases (typically 2) and Z Z Z = number of rotor teeth (commonly 50). Each tooth pitch is crossed in 2 m 2m 2 m full steps, giving the standard hybrid stepper angle: θ s = 360 ∘ 2 × 2 × 50 = 1.8 ∘ ( ⟹ 200 steps per revolution ) \theta_s = \frac{360^\circ}{2 \times 2 \times 50} = 1.8^\circ \quad (\implies 200\,\text{steps per revolution}) θ s = 2 × 2 × 50 36 0 ∘ = 1. 8 ∘ ( ⟹ 200 steps per revolution )
Microstepping : Modulating phase currents using Pulse-Width Modulation (PWM) into sinusoidal proportions divides each fundamental full step into fractions ( 1 / 4 , 1 / 16 , 1 / 64 , 1 / 256 1/4, 1/16, 1/64, 1/256 1/4 , 1/16 , 1/64 , 1/256 ), smoothing shaft torque and suppressing mid-frequency mechanical resonance.
Torque Behavior : Stepper motors generate high holding torque at zero speed, but usable torque drops rapidly at higher stepping frequencies due to winding inductance ( L / R L/R L / R time constant) limiting current rise.
- Closed-Loop Feedback Control Systems
- Open-Loop vs. Closed-Loop Systems
Open-Loop : Control input is applied without measuring system output. Simple, low cost, unconditionally stable, but unable to compensate for external disturbances (load changes, friction variations) or plant parameter drift.
Closed-Loop (Feedback) : Sensor monitors the output y ( t ) y(t) y ( t ) , subtracts it from reference setpoint r ( t ) r(t) r ( t ) to generate error signal e ( t ) = r ( t ) − y ( t ) e(t) = r(t) - y(t) e ( t ) = r ( t ) − y ( t ) . Provides high disturbance rejection, reduced sensitivity to plant parameter changes, and stabilization of unstable systems.
Block Diagram Algebra & Transfer Functions
Consider a negative feedback system with forward controller C ( s ) C(s) C ( s ) , plant G ( s ) G(s) G ( s ) , and unity feedback ( H ( s ) = 1 H(s) = 1 H ( s ) = 1 ): T ( s ) = Y ( s ) R ( s ) = C ( s ) G ( s ) 1 + C ( s ) G ( s ) T(s) = \frac{Y(s)}{R(s)} = \frac{C(s) G(s)}{1 + C(s) G(s)} T ( s ) = R ( s ) Y ( s ) = 1 + C ( s ) G ( s ) C ( s ) G ( s )
The open-loop loop transfer function is L ( s ) = C ( s ) G ( s ) L(s) = C(s) G(s) L ( s ) = C ( s ) G ( s ) . The characteristic equation governing system stability is: 1 + L ( s ) = 1 + C ( s ) G ( s ) = 0 1 + L(s) = 1 + C(s) G(s) = 0 1 + L ( s ) = 1 + C ( s ) G ( s ) = 0
PID Control Fundamentals
The Proportional-Integral-Derivative (PID) controller is the most widely deployed feedback algorithm in machine design: u ( t ) = K p e ( t ) + K i ∫ 0 t e ( τ ) d τ + K d d e ( t ) d t u(t) = K_p e(t) + K_i \int_0^t e(\tau) d\tau + K_d \frac{de(t)}{dt} u ( t ) = K p e ( t ) + K i ∫ 0 t e ( τ ) d τ + K d d t d e ( t )
In the Laplace domain: C ( s ) = K p + K i s + K d s = K d s 2 + K p s + K i s C(s) = K_p + \frac{K_i}{s} + K_d s = \frac{K_d s^2 + K_p s + K_i}{s} C ( s ) = K p + s K i + K d s = s K d s 2 + K p s + K i PID Tuning Influences
- +----------------------------------------------------------------------------------------+
- | Parameter | Rise Time | Overshoot | Settling Time | Steady-State Error | Stability |
- |-----------+---------------+---------------+---------------+--------------------+-----------|
- | Increase K_p | Decreases | Increases | Minor Effect | Decreases (offset) | Degrades |
- | Increase K_i | Decreases | Increases | Increases | Eliminates to ZERO | Degrades |
- | Increase K_d | Minor Effect| Decreases | Decreases | Minor Effect | Improves |
- +----------------------------------------------------------------------------------------+
Proportional Gain ( K p K_p K p ) : Provides immediate restoring action proportional to current error. Accelerates response and reduces steady-state error, but high K p K_p K p induces excessive overshoot and oscillation.
Integral Gain ( K i K_i K i ) : Integrates past error over time. Adds a free integrator (pole at s = 0 s = 0 s = 0 ), raising system type by 1 and forcing steady-state error to zero ( e s s = 0 e_{ss} = 0 e ss = 0 ) under step commands and constant disturbance loads. However, introduces − 90 ∘ -90^\circ − 9 0 ∘ phase lag, which reduces damping and can cause integral windup during actuator saturation.
Derivative Gain ( K d K_d K d ) : Anticipates future error based on rate of change ( d e / d t de/dt d e / d t ). Adds phase lead, increasing effective damping, suppressing overshoot, and accelerating settling time. However, amplifies high-frequency measurement noise; practical implementations require a first-order low-pass filter on the derivative term: C d ( s ) = K d s τ f s + 1 C_d(s) = \frac{K_d s}{\tau_f s + 1} C d ( s ) = τ f s + 1 K d s .
Stability Analysis & Routh-Hurwitz Stability Criterion
A closed-loop linear system is Bounded-Input Bounded-Output (BIBO) stable if and only if all roots of the characteristic equation lie strictly in the open left-half complex plane ( Re ( s ) < 0 \text{Re}(s) < 0 Re ( s ) < 0 ).
For a general characteristic polynomial: A ( s ) = a n s n + a n − 1 s n − 1 + a n − 2 s n − 2 + ⋯ + a 1 s + a 0 = 0 A(s) = a_n s^n + a_{n-1} s^{n-1} + a_{n-2} s^{n-2} + \dots + a_1 s + a_0 = 0 A ( s ) = a n s n + a n − 1 s n − 1 + a n − 2 s n − 2 + ⋯ + a 1 s + a 0 = 0
Necessary Condition (Stodola) : All coefficients a i a_i a i must be strictly positive ( a i > 0 a_i > 0 a i > 0 ) and non-zero.
Routh-Hurwitz Array : Form the array from polynomial coefficients: s n a n a n − 2 a n − 4 … s n − 1 a n − 1 a n − 3 a n − 5 … s n − 2 b 1 b 2 b 3 … s n − 3 c 1 c 2 c 3 … \begin{array}{c|cccc}
- s^n & a_n & a_{n-2} & a_{n-4} & \dots \\
- s^{n-1} & a_{n-1} & a_{n-3} & a_{n-5} & \dots \\
- s^{n-2} & b_1 & b_2 & b_3 & \dots \\
- s^{n-3} & c_1 & c_2 & c_3 & \dots
\end{array} s n s n − 1 s n − 2 s n − 3 a n a n − 1 b 1 c 1 a n − 2 a n − 3 b 2 c 2 a n − 4 a n − 5 b 3 c 3 … … … … where: b 1 = a n − 1 a n − 2 − a n a n − 3 a n − 1 , b 2 = a n − 1 a n − 4 − a n a n − 5 a n − 1 b_1 = \frac{a_{n-1} a_{n-2} - a_n a_{n-3}}{a_{n-1}}, \qquad b_2 = \frac{a_{n-1} a_{n-4} - a_n a_{n-5}}{a_{n-1}} b 1 = a n − 1 a n − 1 a n − 2 − a n a n − 3 , b 2 = a n − 1 a n − 1 a n − 4 − a n a n − 5 c 1 = b 1 a n − 3 − a n − 1 b 2 b 1 c_1 = \frac{b_1 a_{n-3} - a_{n-1} b_2}{b_1} c 1 = b 1 b 1 a n − 3 − a n − 1 b 2 Criterion : The number of roots with positive real parts (unstable poles) equals the number of sign changes in the first column of the Routh array. For absolute stability, there must be zero sign changes in the first column .
For a Third-Order System ( s 3 + a 2 s 2 + a 1 s + a 0 = 0 s^3 + a_2 s^2 + a_1 s + a_0 = 0 s 3 + a 2 s 2 + a 1 s + a 0 = 0 ): s 3 1 a 1 s 2 a 2 a 0 s 1 a 2 a 1 − a 0 a 2 0 s 0 a 0 0 \begin{array}{c|cc}
- s^3 & 1 & a_1 \\
- s^2 & a_2 & a_0 \\
- s^1 & \frac{a_2 a_1 - a_0}{a_2} & 0 \\
- s^0 & a_0 & 0
- \end{array} s 3 s 2 s 1 s 0 1 a 2 a 2 a 2 a 1 − a 0 a 0 a 1 a 0 0 0
The system is strictly stable if and only if: a 2 > 0 , a 1 > 0 , a 0 > 0 , and a 2 a 1 > a 0 a_2 > 0, \quad a_1 > 0, \quad a_0 > 0, \quad \text{and} \quad a_2 a_1 > a_0 a 2 > 0 , a 1 > 0 , a 0 > 0 , and a 2 a 1 > a 0
- Step-by-Step Worked Sensor & Control Scenario
- Problem Statement
An automated machine spindle drive requires precision torque measurement and closed-loop speed control.
Part A: Wheatstone Bridge Strain Gage Transducer
A solid steel shaft of diameter d = 30.0 mm d = 30.0\,\text{mm} d = 30.0 mm ( 0.030 m 0.030\,\text{m} 0.030 m ) transmits a steady working torque T = 250.0 N ⋅ m T = 250.0\,\text{N}\cdot\text{m} T = 250.0 N ⋅ m . The shear modulus of elasticity of the steel is G = 79.3 GPa G = 79.3\,\text{GPa} G = 79.3 GPa . Four identical metallic foil strain gages with nominal resistance R = 350.0 Ω R = 350.0\,\Omega R = 350.0 Ω and Gage Factor G F = 2.10 GF = 2.10 GF = 2.10 are bonded to the shaft surface at ± 45 ∘ \pm 45^\circ ± 4 5 ∘ helix angles to measure the principal tensile and compressive strains induced by torsion in a full Wheatstone bridge configuration. The bridge excitation voltage is V s = 10.0 V V_s = 10.0\,\text{V} V s = 10.0 V .
Calculate:
The maximum torsional surface shear stress τ max \tau_{\max} τ m a x and the resulting surface principal strain ϵ \epsilon ϵ .
The differential output voltage V out V_{\text{out}} V out produced by the full Wheatstone bridge in millivolts.
Part B: Closed-Loop Speed Control & Stability
The DC spindle drive and load have the plant transfer function: G ( s ) = 25 s ( s + 5 ) G(s) = \frac{25}{s(s + 5)} G ( s ) = s ( s + 5 ) 25
A proportional-derivative (PD) controller C ( s ) = K p + K d s C(s) = K_p + K_d s C ( s ) = K p + K d s is placed in the forward path with unity negative feedback ( H ( s ) = 1 H(s) = 1 H ( s ) = 1 ).
Calculate:
The closed-loop characteristic equation in terms of K p K_p K p and K d K_d K d .
The required gains K p K_p K p and K d K_d K d to achieve a closed-loop natural frequency ω n = 10.0 rad/s \omega_n = 10.0\,\text{rad/s} ω n = 10.0 rad/s and a damping ratio ζ = 0.707 \zeta = 0.707 ζ = 0.707 .
If an integral gain K i K_i K i is added to form a full PID controller ( C ( s ) = K d s 2 + K p s + K i s C(s) = \frac{K_d s^2 + K_p s + K_i}{s} C ( s ) = s K d s 2 + K p s + K i ), apply the Routh-Hurwitz criterion to determine the maximum upper bound on K i K_i K i for which the closed-loop system remains strictly stable.
- Step-by-Step Solution
- Step 1: Torsional Stress & Principal Strain
Compute the polar moment of inertia J J J of the solid circular shaft: J = π d 4 32 = π ( 0.030 m ) 4 32 = π × 8.1 × 10 − 7 32 = 7.9522 × 10 − 8 m 4 J = \frac{\pi d^4}{32} = \frac{\pi (0.030\,\text{m})^4}{32} = \frac{\pi \times 8.1 \times 10^{-7}}{32} = 7.9522 \times 10^{-8}\,\text{m}^4 J = 32 π d 4 = 32 π ( 0.030 m ) 4 = 32 π × 8.1 × 1 0 − 7 = 7.9522 × 1 0 − 8 m 4
Compute maximum surface shear stress τ max \tau_{\max} τ m a x : τ max = T ( d / 2 ) J = 16 T π d 3 = 16 × 250.0 π ( 0.030 ) 3 = 4 , 000 8.4823 × 10 − 5 = 4.7157 × 10 7 Pa = 47.16 MPa \tau_{\max} = \frac{T (d/2)}{J} = \frac{16 T}{\pi d^3} = \frac{16 \times 250.0}{\pi (0.030)^3} = \frac{4,\!000}{8.4823 \times 10^{-5}} = 4.7157 \times 10^7\,\text{Pa} = 47.16\,\text{MPa} τ m a x = J T ( d /2 ) = π d 3 16 T = π ( 0.030 ) 3 16 × 250.0 = 8.4823 × 1 0 − 5 4 , 000 = 4.7157 × 1 0 7 Pa = 47.16 MPa
Compute the surface engineering shear strain γ \gamma γ : γ = τ max G = 47.157 × 10 6 Pa 79.3 × 10 9 Pa = 5.9467 × 10 − 4 rad \gamma = \frac{\tau_{\max}}{G} = \frac{47.157 \times 10^6\,\text{Pa}}{79.3 \times 10^9\,\text{Pa}} = 5.9467 \times 10^{-4}\,\text{rad} γ = G τ m a x = 79.3 × 1 0 9 Pa 47.157 × 1 0 6 Pa = 5.9467 × 1 0 − 4 rad
In pure torsion, the principal normal stresses occur at ± 45 ∘ \pm 45^\circ ± 4 5 ∘ to the shaft axis with magnitudes σ 1 = + τ max \sigma_1 = +\tau_{\max} σ 1 = + τ m a x and σ 2 = − τ max \sigma_2 = -\tau_{\max} σ 2 = − τ m a x . The corresponding principal normal strains are: ϵ 1 = + γ 2 = + 2.9734 × 10 − 4 = + 297.3 μ ε \epsilon_1 = +\frac{\gamma}{2} = +2.9734 \times 10^{-4} = +297.3\,\mu\varepsilon ϵ 1 = + 2 γ = + 2.9734 × 1 0 − 4 = + 297.3 μ ε ϵ 2 = − γ 2 = − 2.9734 × 10 − 4 = − 297.3 μ ε \epsilon_2 = -\frac{\gamma}{2} = -2.9734 \times 10^{-4} = -297.3\,\mu\varepsilon ϵ 2 = − 2 γ = − 2.9734 × 1 0 − 4 = − 297.3 μ ε
Step 2: Full-Bridge Output Voltage
In a full-bridge torsion setup, gages 1 and 3 experience tensile principal strain ϵ 1 = ϵ 3 = + ϵ \epsilon_1 = \epsilon_3 = +\epsilon ϵ 1 = ϵ 3 = + ϵ , and gages 2 and 4 experience compressive principal strain ϵ 2 = ϵ 4 = − ϵ \epsilon_2 = \epsilon_4 = -\epsilon ϵ 2 = ϵ 4 = − ϵ : V out V s = G F 4 ( ϵ 1 − ϵ 2 + ϵ 3 − ϵ 4 ) = G F 4 [ ϵ − ( − ϵ ) + ϵ − ( − ϵ ) ] = G F 4 ( 4 ϵ ) = G F ⋅ ϵ \frac{V_{\text{out}}}{V_s} = \frac{GF}{4} (\epsilon_1 - \epsilon_2 + \epsilon_3 - \epsilon_4) = \frac{GF}{4} [\epsilon - (-\epsilon) + \epsilon - (-\epsilon)] = \frac{GF}{4} (4\epsilon) = GF \cdot \epsilon V s V out = 4 GF ( ϵ 1 − ϵ 2 + ϵ 3 − ϵ 4 ) = 4 GF [ ϵ − ( − ϵ ) + ϵ − ( − ϵ )] = 4 GF ( 4 ϵ ) = GF ⋅ ϵ V out = V s ⋅ G F ⋅ ϵ = ( 10.0 V ) × ( 2.10 ) × ( 2.9734 × 10 − 4 ) = 6.244 × 10 − 3 V = 6.24 mV V_{\text{out}} = V_s \cdot GF \cdot \epsilon = (10.0\,\text{V}) \times (2.10) \times (2.9734 \times 10^{-4}) = 6.244 \times 10^{-3}\,\text{V} = 6.24\,\text{mV} V out = V s ⋅ GF ⋅ ϵ = ( 10.0 V ) × ( 2.10 ) × ( 2.9734 × 1 0 − 4 ) = 6.244 × 1 0 − 3 V = 6.24 mV
The full-bridge circuit outputs 6.24 mV 6.24\,\text{mV} 6.24 mV , which can be directly fed into an instrumentation amplifier.
Step 3: PD Control Parameter Tuning
The closed-loop transfer function is: T ( s ) = C ( s ) G ( s ) 1 + C ( s ) G ( s ) = ( K p + K d s ) 25 s ( s + 5 ) 1 + ( K p + K d s ) 25 s ( s + 5 ) = 25 K d s + 25 K p s ( s + 5 ) + 25 ( K d s + K p ) T(s) = \frac{C(s) G(s)}{1 + C(s) G(s)} = \frac{(K_p + K_d s) \frac{25}{s(s + 5)}}{1 + (K_p + K_d s) \frac{25}{s(s + 5)}} = \frac{25 K_d s + 25 K_p}{s(s + 5) + 25(K_d s + K_p)} T ( s ) = 1 + C ( s ) G ( s ) C ( s ) G ( s ) = 1 + ( K p + K d s ) s ( s + 5 ) 25 ( K p + K d s ) s ( s + 5 ) 25 = s ( s + 5 ) + 25 ( K d s + K p ) 25 K d s + 25 K p
The characteristic equation is: s 2 + ( 5 + 25 K d ) s + 25 K p = 0 s^2 + (5 + 25 K_d) s + 25 K_p = 0 s 2 + ( 5 + 25 K d ) s + 25 K p = 0
Compare to the standard second-order canonical form s 2 + 2 ζ ω n s + ω n 2 = 0 s^2 + 2 \zeta \omega_n s + \omega_n^2 = 0 s 2 + 2 ζ ω n s + ω n 2 = 0 :
Match the constant term: ω n 2 = 25 K p ⟹ ( 10.0 ) 2 = 25 K p ⟹ 100 = 25 K p ⟹ K p = 4.0 \omega_n^2 = 25 K_p \implies (10.0)^2 = 25 K_p \implies 100 = 25 K_p \implies K_p = 4.0 ω n 2 = 25 K p ⟹ ( 10.0 ) 2 = 25 K p ⟹ 100 = 25 K p ⟹ K p = 4.0
Match the linear damping coefficient: 2 ζ ω n = 5 + 25 K d ⟹ 2 ( 0.707 ) ( 10.0 ) = 5 + 25 K d ⟹ 14.14 = 5 + 25 K d 2 \zeta \omega_n = 5 + 25 K_d \implies 2 (0.707)(10.0) = 5 + 25 K_d \implies 14.14 = 5 + 25 K_d 2 ζ ω n = 5 + 25 K d ⟹ 2 ( 0.707 ) ( 10.0 ) = 5 + 25 K d ⟹ 14.14 = 5 + 25 K d 25 K d = 14.14 − 5 = 9.14 ⟹ K d = 9.14 25 = 0.3656 s 25 K_d = 14.14 - 5 = 9.14 \implies K_d = \frac{9.14}{25} = 0.3656\,\text{s} 25 K d = 14.14 − 5 = 9.14 ⟹ K d = 25 9.14 = 0.3656 s
Step 4: PID Stability Boundary via Routh-Hurwitz
With PID controller C ( s ) = K d s 2 + K p s + K i s C(s) = \frac{K_d s^2 + K_p s + K_i}{s} C ( s ) = s K d s 2 + K p s + K i , the loop transfer function is: L ( s ) = C ( s ) G ( s ) = K d s 2 + K p s + K i s ⋅ 25 s ( s + 5 ) = 25 ( K d s 2 + K p s + K i ) s 2 ( s + 5 ) L(s) = C(s) G(s) = \frac{K_d s^2 + K_p s + K_i}{s} \cdot \frac{25}{s(s + 5)} = \frac{25(K_d s^2 + K_p s + K_i)}{s^2(s + 5)} L ( s ) = C ( s ) G ( s ) = s K d s 2 + K p s + K i ⋅ s ( s + 5 ) 25 = s 2 ( s + 5 ) 25 ( K d s 2 + K p s + K i )
The new third-order closed-loop characteristic equation is: s 2 ( s + 5 ) + 25 ( K d s 2 + K p s + K i ) = 0 ⟹ s 3 + ( 5 + 25 K d ) s 2 + 25 K p s + 25 K i = 0 s^2(s + 5) + 25(K_d s^2 + K_p s + K_i) = 0 \implies s^3 + (5 + 25 K_d) s^2 + 25 K_p s + 25 K_i = 0 s 2 ( s + 5 ) + 25 ( K d s 2 + K p s + K i ) = 0 ⟹ s 3 + ( 5 + 25 K d ) s 2 + 25 K p s + 25 K i = 0
Substitute K p = 4.0 K_p = 4.0 K p = 4.0 and K d = 0.3656 K_d = 0.3656 K d = 0.3656 :
a 2 = 5 + 25 ( 0.3656 ) = 5 + 9.14 = 14.14 a_2 = 5 + 25(0.3656) = 5 + 9.14 = 14.14 a 2 = 5 + 25 ( 0.3656 ) = 5 + 9.14 = 14.14
- a 1 = 25 K p = 25 ( 4.0 ) = 100.0 a_1 = 25 K_p = 25(4.0) = 100.0 a 1 = 25 K p = 25 ( 4.0 ) = 100.0
- a 0 = 25 K i a_0 = 25 K_i a 0 = 25 K i
The characteristic equation is: s 3 + 14.14 s 2 + 100.0 s + 25 K i = 0 s^3 + 14.14 s^2 + 100.0 s + 25 K_i = 0 s 3 + 14.14 s 2 + 100.0 s + 25 K i = 0
Applying the Routh-Hurwitz stability criterion for a 3rd-order system ( a 2 a 1 > a 0 a_2 a_1 > a_0 a 2 a 1 > a 0 with all a i > 0 a_i > 0 a i > 0 ): 25 K i > 0 ⟹ K i > 0 25 K_i > 0 \implies K_i > 0 25 K i > 0 ⟹ K i > 0 a 2 a 1 > a 0 ⟹ ( 14.14 ) × ( 100.0 ) > 25 K i ⟹ 1 , 414 > 25 K i a_2 a_1 > a_0 \implies (14.14) \times (100.0) > 25 K_i \implies 1,\!414 > 25 K_i a 2 a 1 > a 0 ⟹ ( 14.14 ) × ( 100.0 ) > 25 K i ⟹ 1 , 414 > 25 K i K i < 1 , 414 25 = 56.56 s − 1 K_i < \frac{1,\!414}{25} = 56.56\,\text{s}^{-1} K i < 25 1 , 414 = 56.56 s − 1
Therefore, for the system to remain strictly stable, the integral gain must satisfy: 0 < K i < 56.56 s − 1 0 < K_i < 56.56\,\text{s}^{-1} 0 < K i < 56.56 s − 1
Exceeding K i = 56.56 K_i = 56.56 K i = 56.56 will drive the closed-loop poles across the imaginary axis into the right-half plane, causing sustained oscillations and unstable runaway.