Study guide
2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
Key Takeaways Explain This Topic AI
Preloading a threaded fastener generates clamping compression across joined members ( F i ≈ 0.75 A t S p F_i \approx 0.75 A_t S_p F i ≈ 0.75 A t S p for reusable joints, 0.90 A t S p 0.90 A_t S_p 0.90 A t S p for permanent joints), drastically reducing the alternating stress amplitude transmitted to the bolt.
Under an external tensile load P P P , the load is shared elastically between bolt and members according to the joint stiffness constant C = k b k b + k m C = \frac{k_b}{k_b + k_m} C = k b + k m k b ; total bolt load is F b = F i + C P F_b = F_i + C P F b = F i + CP and member clamping force is F m = F i − ( 1 − C ) P F_m = F_i - (1-C)P F m = F i − ( 1 − C ) P .
Joint separation occurs when member compression drops to zero ( F m = 0 F_m = 0 F m = 0 ), defining the critical separation external load P sep = F i 1 − C P_{\text{sep}} = \frac{F_i}{1 - C} P sep = 1 − C F i .
Bolt fatigue alternating stress is σ a = C P 2 A t \sigma_a = \frac{C P}{2 A_t} σ a = 2 A t CP and is independent of initial preload F i F_i F i ; increasing preload protects against joint loosening and separation without penalizing fatigue life.
Fillet welded joints are analyzed across the theoretical throat area A w = 0.707 h L A_w = 0.707 h L A w = 0.707 h L ; under eccentric loads, primary direct shear τ ′ = V / A w \tau' = V / A_w τ ′ = V / A w and secondary torsional/bending shear τ ′ ′ = M r / J w \tau'' = M r / J_w τ ′′ = M r / J w must be summed vectorially.
Last updated: August 2026
Threaded Fasteners, Welded Connections & Mechanical Joints
Structural integrity in mechanical assemblies depends entirely on the design of mechanical joints. Threaded fasteners and welded connections transfer static and fluctuating multiaxial loads across structural interfaces. Understanding bolt preloading physics, elastic load-sharing stiffness constants ( C C C ), joint separation prevention, and weld group throat shear vectors is mandatory for machine design engineering.
1. Threaded Fasteners, Bolt Grades & Proof Strength +-----------------------------------------------------------------------------+
- | THREADED FASTENER DEFINITIONS |
- | |
- | Tensile Stress Area: A_t = \frac{\pi}{4}\left(d - 0.938194 p\right)^2 |
- | |
- | Proof Strength (S_p): \approx 0.85 S_y \quad (\text{Stress without permanent set}) |
- | |
- | Bolt Preload (F_i): F_i = 0.75 A_t S_p \quad (\text{Reusable joints}) |
- | F_i = 0.90 A_t S_p \quad (\text{Permanent joints}) |
- | |
- | Tightening Torque: T = K F_i d |
- | (K \approx 0.20 \text{ as-received, } 0.15 \text{ lubricated}) |
- +-----------------------------------------------------------------------------+
- Common Bolt Property Classes & Grades
Standard & Class Proof Strength ( S p S_p S p ) Yield Strength ( S y S_y S y ) Tensile Strength ( S u t S_{ut} S u t ) Typical Application
SAE Grade 5 85 kpsi ( 586 MPa ) 85\text{ kpsi } (586\text{ MPa}) 85 kpsi ( 586 MPa ) 92 kpsi ( 634 MPa ) 92\text{ kpsi } (634\text{ MPa}) 92 kpsi ( 634 MPa ) 120 kpsi ( 827 MPa ) 120\text{ kpsi } (827\text{ MPa}) 120 kpsi ( 827 MPa ) General automotive & machinery
SAE Grade 8 120 kpsi ( 827 MPa ) 120\text{ kpsi } (827\text{ MPa}) 120 kpsi ( 827 MPa ) 130 kpsi ( 896 MPa ) 130\text{ kpsi } (896\text{ MPa}) 130 kpsi ( 896 MPa ) 150 kpsi ( 1034 MPa ) 150\text{ kpsi } (1034\text{ MPa}) 150 kpsi ( 1034 MPa ) High-stress structural connections
ISO Class 8.8 600 MPa 600\text{ MPa} 600 MPa 640 MPa 640\text{ MPa} 640 MPa 800 MPa 800\text{ MPa} 800 MPa Standard European industrial machinery
ISO Class 10.9 830 MPa 830\text{ MPa} 830 MPa 940 MPa 940\text{ MPa} 940 MPa 1040 MPa 1040\text{ MPa} 1040 MPa High-strength mechanical joints
2. Bolted Joint Elastic Interaction & Joint Constant C C C
A preloaded bolted joint acts as two parallel springs: the bolt is stretched in tension (stiffness k b k_b k b ), while the clamped joint members are squeezed in compression (stiffness k m k_m k m ). Bolt (Tension Spring k_b)
- +---/\/\/\/\/\---+
- | |
- External Load P <======+ CLAMPED ZONE +======> External Load P
- | |
- +---/\/\/\/\/\---+
Members (Compression Spring k_m) +-----------------------------------------------------------------------------+
- | BOLTED JOINT MECHANICS |
- | |
- | Joint Stiffness Constant: C = \frac{k_b}{k_b + k_m} |
- | (Typical range: 0.15 \le C \le 0.30) |
- | |
- | Total Bolt Tensile Load: F_b = F_i + C P |
- | |
- | Total Member Clamping Load: F_m = F_i - (1 - C) P |
- | |
- | Joint Separation Load: P_{\text{sep}} = \frac{F_i}{1 - C} |
- | |
- | Proof Safety Factor: n_p = \frac{S_p A_t}{F_b} = \frac{S_p A_t}{F_i + C P} |
- | |
- | Joint Separation Safety Factor: n_{\text{sep}} = \frac{P_{\text{sep}}}{P} = \frac{F_i}{P (1 - C)} |
- +-----------------------------------------------------------------------------+
Note
Because member stiffness k m k_m k m is typically 3 to 5 times larger than bolt stiffness k b k_b k b , the joint constant C C C is small ( C ≈ 0.20 C \approx 0.20 C ≈ 0.20 ). When an external tensile force P P P is applied, the bolt feels only 20% of the load, while 80% goes into decompressing the clamped flange members!
3. Bolt Fatigue under Fluctuating Tensile Load
Consider an external tensile load cycling repeatedly from 0 0 0 to P P P :
Bolt Minimum Force: F b , min = F i F_{b, \text{min}} = F_i F b , min = F i
Bolt Maximum Force: F b , max = F i + C P F_{b, \text{max}} = F_i + C P F b , max = F i + CP Alternating Force: F a = F b , max − F b , min 2 = C P 2 ⟹ σ a = C P 2 A t \text{Alternating Force: } F_a = \frac{F_{b, \text{max}} - F_{b, \text{min}}}{2} = \frac{C P}{2} \implies \sigma_a = \frac{C P}{2 A_t} Alternating Force: F a = 2 F b , max − F b , min = 2 CP ⟹ σ a = 2 A t CP Mean Force: F m = F b , max + F b , min 2 = F i + C P 2 ⟹ σ m = F i + C P / 2 A t \text{Mean Force: } F_m = \frac{F_{b, \text{max}} + F_{b, \text{min}}}{2} = F_i + \frac{C P}{2} \implies \sigma_m = \frac{F_i + C P / 2}{A_t} Mean Force: F m = 2 F b , max + F b , min = F i + 2 CP ⟹ σ m = A t F i + CP /2
Modified Goodman Fatigue Safety Factor: n f = S e ( S u t − σ i ) σ a ( S u t + S e ) n_f = \frac{S_e (S_{ut} - \sigma_i)}{\sigma_a (S_{ut} + S_e)} n f = σ a ( S u t + S e ) S e ( S u t − σ i )
Where σ i = F i / A t \sigma_i = F_i / A_t σ i = F i / A t is initial preload stress. Key Engineering Principle:
Alternating stress \sigma_a depends ONLY on (C * P) and is INDEPENDENT of preload F_i.
Higher preload does NOT increase fatigue alternating amplitude, but prevents joint separation!
4. Welded Connections: Fillet & Groove Welds +-----------------------------------------------------------------------------+
- | FILLET WELD THROAT MECHANICS |
- | |
- | Leg Size: h (or w) |
- | |
- | Effective Throat: t = h \cos 45^\circ = 0.707 h |
- | |
- | Effective Throat Area: A_w = 0.707 h L |
- | |
- | Allowable Shear Stress (AWS): \tau_{\text{allow}} = 0.30 S_{ut, \text{electrode}} |
- | (E70XX: S_{ut}=70 kpsi \implies \tau_{\text{allow}}=21 kpsi = 145 MPa) |
- +-----------------------------------------------------------------------------+ Plate 1
- +------------+
- | |\
- | | \ <--- Fillet Weld (Leg h)
- | | \
- +------------+---+-------------------+
- | | Throat t = 0.707h
- | | |
- +---+-------------------+
- Plate 2
- 5. Eccentric Loading on Weld Groups (Direct Shear + Torsion)
When a load V V V acts eccentrically at distance e e e from the center of gravity (centroid G G G ) of a weld group, it induces simultaneous primary direct shear ( τ ′ \tau' τ ′ ) and secondary torsional shear ( τ ′ ′ \tau'' τ ′′ ): +-----------------------------------------------------------------------------+
- | ECCENTRIC WELD GROUP FORMULATION |
- | |
- | 1. Primary Direct Shear: \tau' = \frac{V}{A_w} = \frac{V}{0.707 h \sum L_i} |
- | |
- | 2. Secondary Torsional Shear: \tau'' = \frac{M r}{J_w} = \frac{(V e) r}{0.707 h J_u} |
- | (Where J_u = I_{ux} + I_{uy} is unit polar moment of inertia of weld lines) |
- | |
| 3. Vectorial Superposition: \tau_{\text{total}} = \sqrt{(\tau'_x + \tau''_x)^2 + (\tau'_y + \tau''_y)^2} \le \tau_{\text{allow}} |
- +-----------------------------------------------------------------------------+
- 6. Step-by-Step Worked Engineering Problem
- Problem Statement
A rigid steel bracket is attached to a vertical column using two identical vertical fillet welds of length L = 120 mm L = 120\text{ mm} L = 120 mm spaced b = 100 mm b = 100\text{ mm} b = 100 mm apart. An eccentric downward shear load V = 30 kN V = 30\text{ kN} V = 30 kN is applied at an eccentricity e = 150 mm e = 150\text{ mm} e = 150 mm from the weld group centroid. The welds are made using E70XX electrodes ( τ allow = 145 MPa \tau_{\text{allow}} = 145\text{ MPa} τ allow = 145 MPa ).
- Determine the minimum required weld leg size h h h . |<--- e = 150 mm --->|
- | |
- Column | v V = 30 kN
- +----+ +-----+--------------------+
- | |==| | |
- | | | | |
- | | | | G (Centroid) |
- | |==| | |
- +----+ +--------------------------+
- |<b=100>|
- Length L = 120 mm each weld
- Step 1: Weld Group Geometry & Centroid
Two vertical lines of length L = 120 mm L = 120\text{ mm} L = 120 mm at x = ± 50 mm x = \pm 50\text{ mm} x = ± 50 mm .
Centroid G G G is at ( 0 , 0 ) (0, 0) ( 0 , 0 ) . Total length ∑ L = 2 ( 120 ) = 240 mm \sum L = 2(120) = 240\text{ mm} ∑ L = 2 ( 120 ) = 240 mm .
Critical point is the outermost corner: x = 50 mm , y = 60 mm x = 50\text{ mm}, y = 60\text{ mm} x = 50 mm , y = 60 mm . r = x 2 + y 2 = 50 2 + 60 2 = 2500 + 3600 = 78.10 mm r = \sqrt{x^2 + y^2} = \sqrt{50^2 + 60^2} = \sqrt{2500 + 3600} = 78.10\text{ mm} r = x 2 + y 2 = 5 0 2 + 6 0 2 = 2500 + 3600 = 78.10 mm
Step 2: Unit Polar Moment of Inertia ( J u J_u J u )
For two vertical parallel lines of length L L L separated by distance b b b : I u x = 2 ( L 3 12 ) = 2 ( 120 ) 3 12 = 288 , 000 mm 3 I_{ux} = 2 \left(\frac{L^3}{12}\right) = \frac{2(120)^3}{12} = 288,000\text{ mm}^3 I ux = 2 ( 12 L 3 ) = 12 2 ( 120 ) 3 = 288 , 000 mm 3 I u y = 2 ( L ( b 2 ) 2 ) = 2 ( 120 ) ( 50 ) 2 = 600 , 000 mm 3 I_{uy} = 2 \left(L \left(\frac{b}{2}\right)^2\right) = 2 (120)(50)^2 = 600,000\text{ mm}^3 I u y = 2 ( L ( 2 b ) 2 ) = 2 ( 120 ) ( 50 ) 2 = 600 , 000 mm 3 J u = I u x + I u y = 288 , 000 + 600 , 000 = 888 , 000 mm 3 J_u = I_{ux} + I_{uy} = 288,000 + 600,000 = 888,000\text{ mm}^3 J u = I ux + I u y = 288 , 000 + 600 , 000 = 888 , 000 mm 3
Step 3: Primary Direct Shear Stress Vector ( τ ′ \tau' τ ′ )
Direct downward load: V y = − 30 kN V_y = -30\text{ kN} V y = − 30 kN . τ y ′ = V 0.707 h ∑ L = 30 , 000 0.707 h ( 240 ) = 176.81 h MPa (Downward) \tau'_y = \frac{V}{0.707 h \sum L} = \frac{30,000}{0.707 h (240)} = \frac{176.81}{h}\text{ MPa (Downward)} τ y ′ = 0.707 h ∑ L V = 0.707 h ( 240 ) 30 , 000 = h 176.81 MPa (Downward) τ x ′ = 0 \tau'_x = 0 τ x ′ = 0
Step 4: Secondary Torsional Shear Stress Vector ( τ ′ ′ \tau'' τ ′′ )
Clockwise moment: M = V e = 30 , 000 N × 150 mm = 4.50 × 10 6 N ⋅ mm M = V e = 30,000\text{ N} \times 150\text{ mm} = 4.50 \times 10^6\text{ N}\cdot\text{mm} M = V e = 30 , 000 N × 150 mm = 4.50 × 1 0 6 N ⋅ mm . τ ′ ′ = M r 0.707 h J u = ( 4.50 × 10 6 ) ( 78.10 ) 0.707 h ( 888 , 000 ) = 559.88 h MPa \tau'' = \frac{M r}{0.707 h J_u} = \frac{(4.50 \times 10^6)(78.10)}{0.707 h (888,000)} = \frac{559.88}{h}\text{ MPa} τ ′′ = 0.707 h J u M r = 0.707 h ( 888 , 000 ) ( 4.50 × 1 0 6 ) ( 78.10 ) = h 559.88 MPa
Resolving τ ′ ′ \tau'' τ ′′ into orthogonal components at top-right corner ( + 50 , + 60 ) (+50, +60) ( + 50 , + 60 ) : τ x ′ ′ = τ ′ ′ sin θ = τ ′ ′ ( y r ) = 559.88 h ( 60 78.10 ) = 430.13 h MPa (Rightward) \tau''_x = \tau'' \sin \theta = \tau'' \left(\frac{y}{r}\right) = \frac{559.88}{h} \left(\frac{60}{78.10}\right) = \frac{430.13}{h}\text{ MPa (Rightward)} τ x ′′ = τ ′′ sin θ = τ ′′ ( r y ) = h 559.88 ( 78.10 60 ) = h 430.13 MPa (Rightward) τ y ′ ′ = − τ ′ ′ cos θ = − τ ′ ′ ( x r ) = − 559.88 h ( 50 78.10 ) = − 358.44 h MPa (Downward) \tau''_y = -\tau'' \cos \theta = -\tau'' \left(\frac{x}{r}\right) = -\frac{559.88}{h} \left(\frac{50}{78.10}\right) = -\frac{358.44}{h}\text{ MPa (Downward)} τ y ′′ = − τ ′′ cos θ = − τ ′′ ( r x ) = − h 559.88 ( 78.10 50 ) = − h 358.44 MPa (Downward)
Step 5: Vectorial Superposition & Sizing τ total , x = τ x ′ + τ x ′ ′ = 0 + 430.13 h = 430.13 h \tau_{\text{total}, x} = \tau'_x + \tau''_x = 0 + \frac{430.13}{h} = \frac{430.13}{h} τ total , x = τ x ′ + τ x ′′ = 0 + h 430.13 = h 430.13 τ total , y = τ y ′ + τ y ′ ′ = − 176.81 h − 358.44 h = − 535.25 h \tau_{\text{total}, y} = \tau'_y + \tau''_y = -\frac{176.81}{h} - \frac{358.44}{h} = -\frac{535.25}{h} τ total , y = τ y ′ + τ y ′′ = − h 176.81 − h 358.44 = − h 535.25 τ resultant = τ x 2 + τ y 2 = ( 430.13 ) 2 + ( − 535.25 ) 2 h = 185011.8 + 286492.6 h = 686.66 h MPa \tau_{\text{resultant}} = \sqrt{\tau_x^2 + \tau_y^2} = \frac{\sqrt{(430.13)^2 + (-535.25)^2}}{h} = \frac{\sqrt{185011.8 + 286492.6}}{h} = \frac{686.66}{h}\text{ MPa} τ resultant = τ x 2 + τ y 2 = h ( 430.13 ) 2 + ( − 535.25 ) 2 = h 185011.8 + 286492.6 = h 686.66 MPa
Setting τ resultant ≤ τ allow = 145 MPa \tau_{\text{resultant}} \le \tau_{\text{allow}} = 145\text{ MPa} τ resultant ≤ τ allow = 145 MPa : h ≥ 686.66 145 = 4.74 mm ⟹ Specify standard h = 5.0 mm or 6.0 mm leg size h \ge \frac{686.66}{145} = 4.74\text{ mm} \implies \text{Specify standard } h = 5.0\text{ mm or } 6.0\text{ mm leg size} h ≥ 145 686.66 = 4.74 mm ⟹ Specify standard h = 5.0 mm or 6.0 mm leg size
7. Common Exam Traps & PE Pro-Tips
Trap 1 — Direct Addition of Primary and Secondary Weld Shears: Primary and secondary shear stresses act in different angular directions. Always break τ ′ ′ \tau'' τ ′′ into x x x and y y y vector components before adding to τ ′ \tau' τ ′ .
Trap 2 — Torque-Tension Unit Mismatch: In T = K F i d T = K F_i d T = K F i d , nominal diameter d d d must be in meters if torque is in N ⋅ m \text{N}\cdot\text{m} N ⋅ m , or inches if torque is in lb ⋅ in \text{lb}\cdot\text{in} lb ⋅ in .
Trap 3 — Misunderstanding Preload in Fatigue: Preload does not increase cyclic stress amplitude σ a \sigma_a σ a . In fact, higher preload prevents joint separation, keeping the effective joint stiffness constant C C C active.