Study guide
5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle)
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle)
Key Takeaways Explain This Topic AI
The ideal air-standard Brayton cycle consists of isentropic compression, constant-pressure combustion, isentropic expansion, and constant-pressure heat rejection, with efficiency dictated entirely by the pressure ratio: η t h = 1 − 1 / r p ( k − 1 ) / k \eta_{th} = 1 - 1 / r_p^{(k-1)/k} η t h = 1 − 1/ r p ( k − 1 ) / k .
Gas turbine cycles exhibit very high Back Work Ratios ( B W R = w c / w t ≈ 40 − 60 % BWR = w_c / w_t \approx 40-60\% B W R = w c / w t ≈ 40 − 60% ) because compressing a low-density compressible gas requires substantial mechanical work compared to liquid pumping.
Brayton modifications—multi-stage compression with intercooling, multi-stage expansion with reheat, and exhaust recuperation/regeneration—greatly increase net work output and thermal efficiency.
Combined Cycle Gas Turbine (CCGT) power plants combine a topping Brayton turbine with a bottoming Rankine steam generator (HRSG) to achieve world-class thermal efficiencies of 55–65%.
Internal combustion reciprocating engine cycles (Otto for spark-ignition, Diesel for compression-ignition, and Dual) are characterized by compression ratio r r r , cutoff ratio r c r_c r c , and Mean Effective Pressure ( M E P MEP MEP ).
Last updated: August 2026
Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle)
Gas power cycles utilize a gaseous working fluid throughout the entire thermodynamic cycle without undergoing phase change. Gas turbine engines operating on the Brayton cycle power commercial aviation, peaking utility power generation, and baseload Combined Cycle Gas Turbine (CCGT) power plants. Reciprocating internal combustion engines operating on Otto , Diesel , and Dual cycles drive transportation and distributed power generation.
1. Air-Standard Assumptions & The Ideal Brayton Cycle
To analyze complex gas power cycles analytically, engineers employ the standard Air-Standard Assumptions :
The working fluid is a fixed mass of air that behaves throughout as an ideal gas.
All processes are internally reversible.
The combustion process is modeled as an external constant-pressure or constant-volume heat addition process from an external source.
The exhaust stroke/blowdown is modeled as a constant-pressure or constant-volume heat rejection process to an external sink.
Under Cold-Air-Standard Assumptions , specific heats are evaluated at ambient room temperature ( 300 K / 520 ∘ R 300\text{ K} / 520{}^\circ\text{R} 300 K /520 ∘ R , k = 1.40 , c p = 1.005 kJ/(kg ⋅ K) k = 1.40, c_p = 1.005\text{ kJ/(kg}\cdot\text{K)} k = 1.40 , c p = 1.005 kJ/(kg ⋅ K) ). +-----------------------------------------------------------------------------------------+
- | THE IDEAL BRAYTON CYCLE |
- | |
- | Combustion Chamber (q_in) |
- | +------------------------------+ |
- | | P_2 = P_3 = constant | |
- | +------------------------------+ |
- | ^ | |
- | State 2 | Compressed Air | State 3: Hot Combustion Gas |
- | (High-P, T2) | v (High-P, T3 = T_TIT) |
- | +------------+ | +------------+ |
- | w_c,in --> | COMPRESSOR |---+ | TURBINE | ----> w_t,out |
- | +------------+ +------------+ |
- | ^ | |
- | State 1 | Ambient Air | State 4: Hot Exhaust Gas |
- | (P1, T1) | v (Low-P, T4) |
- | +------------------------------+ |
- | | P_4 = P_1 = constant | |
- | +------------------------------+ |
- | Exhaust Cooler (q_out) |
+-----------------------------------------------------------------------------------------+ P-v Diagram: Brayton Cycle T-s Diagram: Brayton Cycle
- P ^ T ^
- | Combustion (2->3, P=const) | 3 (TIT: Max Temp)
- | 2 *-----------* 3 | /|
- | / \ | / |
- | Comp. / \ Turb. | 2 / | Expansion (3->4s)
- | (1->2)/ \ (3->4) | /|________/ |
- | *-------------------* | / | q_in |
- | 1 Heat Rejection 4 | 1--+------------+-- 4 (Exhaust)
- | (4->1, P=const) | | | q_out |
- +-----------------------------------> v +------------------------> s
- Mathematical Formulation of the Ideal Brayton Cycle
Let the Pressure Ratio be defined as r p = P 2 / P 1 = P 3 / P 4 r_p = P_2 / P_1 = P_3 / P_4 r p = P 2 / P 1 = P 3 / P 4 .
For isentropic compression ( 1 → 2 1 \to 2 1 → 2 ) and expansion ( 3 → 4 3 \to 4 3 → 4 ): T 2 T 1 = ( P 2 P 1 ) k − 1 k = r p k − 1 k ⟹ T 2 = T 1 ⋅ r p k − 1 k \frac{T_2}{T_1} = \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} = r_p^{\frac{k-1}{k}} \implies T_2 = T_1 \cdot r_p^{\frac{k-1}{k}} T 1 T 2 = ( P 1 P 2 ) k k − 1 = r p k k − 1 ⟹ T 2 = T 1 ⋅ r p k k − 1 T 3 T 4 = ( P 3 P 4 ) k − 1 k = r p k − 1 k ⟹ T 4 = T 3 r p k − 1 k \frac{T_3}{T_4} = \left(\frac{P_3}{P_4}\right)^{\frac{k-1}{k}} = r_p^{\frac{k-1}{k}} \implies T_4 = \frac{T_3}{r_p^{\frac{k-1}{k}}} T 4 T 3 = ( P 4 P 3 ) k k − 1 = r p k k − 1 ⟹ T 4 = r p k k − 1 T 3 w c , i n = c p ( T 2 − T 1 ) , w t , o u t = c p ( T 3 − T 4 ) w_{c,in} = c_p (T_2 - T_1), \quad w_{t,out} = c_p (T_3 - T_4) w c , in = c p ( T 2 − T 1 ) , w t , o u t = c p ( T 3 − T 4 ) q i n = c p ( T 3 − T 2 ) , q o u t = c p ( T 4 − T 1 ) q_{in} = c_p (T_3 - T_2), \quad q_{out} = c_p (T_4 - T_1) q in = c p ( T 3 − T 2 ) , q o u t = c p ( T 4 − T 1 )
Thermal Efficiency & Back Work Ratio η t h , B r a y t o n = w n e t q i n = 1 − q o u t q i n = 1 − c p ( T 4 − T 1 ) c p ( T 3 − T 2 ) = 1 − 1 r p k − 1 k \eta_{th,Brayton} = \frac{w_{net}}{q_{in}} = 1 - \frac{q_{out}}{q_{in}} = 1 - \frac{c_p(T_4 - T_1)}{c_p(T_3 - T_2)} = 1 - \frac{1}{r_p^{\frac{k-1}{k}}} η t h , B r a y t o n = q in w n e t = 1 − q in q o u t = 1 − c p ( T 3 − T 2 ) c p ( T 4 − T 1 ) = 1 − r p k k − 1 1 B W R = w c , i n w t , o u t = T 2 − T 1 T 3 − T 4 ≈ 0.40 to 0.60 BWR = \frac{w_{c,in}}{w_{t,out}} = \frac{T_2 - T_1}{T_3 - T_4} \approx 0.40 \text{ to } 0.60 B W R = w t , o u t w c , in = T 3 − T 4 T 2 − T 1 ≈ 0.40 to 0.60
Important
Optimum Pressure Ratio for Maximum Net Work: While thermal efficiency increases monotonically with pressure ratio r p r_p r p , the net specific work output ( w n e t = w t − w c w_{net} = w_t - w_c w n e t = w t − w c ) peaks at an intermediate optimum pressure ratio: r p , o p t = ( T m a x T m i n ) k 2 ( k − 1 ) = ( T 3 T 1 ) k 2 ( k − 1 ) r_{p,opt} = \left(\frac{T_{max}}{T_{min}}\right)^{\frac{k}{2(k-1)}} = \left(\frac{T_3}{T_1}\right)^{\frac{k}{2(k-1)}} r p , o pt = ( T min T ma x ) 2 ( k − 1 ) k = ( T 1 T 3 ) 2 ( k − 1 ) k
Real Cycle Component Efficiencies
Accounting for compressor and turbine isentropic efficiencies: w c , a c t u a l = w c , s η c = c p ( T 2 s − T 1 ) η c ⟹ T 2 a = T 1 + T 2 s − T 1 η c w_{c,actual} = \frac{w_{c,s}}{\eta_c} = \frac{c_p (T_{2s} - T_1)}{\eta_c} \implies T_{2a} = T_1 + \frac{T_{2s} - T_1}{\eta_c} w c , a c t u a l = η c w c , s = η c c p ( T 2 s − T 1 ) ⟹ T 2 a = T 1 + η c T 2 s − T 1 w t , a c t u a l = η t ⋅ w t , s = η t c p ( T 3 − T 4 s ) ⟹ T 4 a = T 3 − η t ( T 3 − T 4 s ) w_{t,actual} = \eta_t \cdot w_{t,s} = \eta_t c_p (T_3 - T_{4s}) \implies T_{4a} = T_3 - \eta_t (T_3 - T_{4s}) w t , a c t u a l = η t ⋅ w t , s = η t c p ( T 3 − T 4 s ) ⟹ T 4 a = T 3 − η t ( T 3 − T 4 s )
2. Brayton Modifications: Intercooling, Reheat & Regeneration
To increase power capacity and thermal efficiency, large industrial gas turbines incorporate multi-stage modifications: +-----------------------------------------------------------------------------------------+
- | BRAYTON MODIFICATION TECHNOLOGIES |
- | |
- | 1. INTERCOOLING (Multi-Stage Compression): |
- | - Cools gas between LP and HP compressor stages. |
- | - Reduces total compressor work (since w = integral v dP; smaller v means less work)|
- | - Optimum intermediate pressure: P_i = sqrt(P_1 * P_2). |
- | |
- | 2. REHEAT (Multi-Stage Expansion): |
- | - Reheats gas between HP and LP turbine stages. |
- | - Increases total turbine work output without exceeding maximum metallurgical TIT. |
- | - Optimum intermediate pressure: P_i = sqrt(P_3 * P_4). |
- | |
- | 3. REGENERATION / RECUPERATION: |
- | - Transfers waste heat from hot turbine exhaust (T4) to preheat compressor |
- | discharge air (T2) before entering combustor. |
- | - Drastically cuts fuel consumption (q_in). |
+-----------------------------------------------------------------------------------------+ T-s Diagram: Brayton Cycle with Intercooling, Reheat & Regeneration
- T ^
- | Combustor Reheater
- | 3 *-----------* 5 (TIT Max Temp)
- | / \
- | Regenerator / \
- | T_x <-------+-- T_4 (Exhaust) +---> T_y (Preheated to Combustor)
- | 2 * / \ * 6
- | /|\ / /|\
- | Inter-/ | \ / / | \ Reheat
- | cool 1* | * 2' 4* | * 5'
- | | | | |
- +-------+-+-------------------------+-+--------> s
- Regenerator Effectiveness ( ϵ \epsilon ϵ )
The effectiveness of a regenerator is the ratio of actual heat transfer to maximum possible heat transfer: ϵ = h 5 − h 2 h 4 − h 2 ≈ T 5 − T 2 T 4 − T 2 \epsilon = \frac{h_5 - h_2}{h_4 - h_2} \approx \frac{T_5 - T_2}{T_4 - T_2} ϵ = h 4 − h 2 h 5 − h 2 ≈ T 4 − T 2 T 5 − T 2
Where T 5 T_5 T 5 is the air temperature exiting the regenerator (entering combustor), T 2 T_2 T 2 is compressor exit temperature, and T 4 T_4 T 4 is turbine exhaust temperature. The thermal efficiency of an ideal regenerator ( ϵ = 1.0 \epsilon = 1.0 ϵ = 1.0 ) cycle is: η t h , r e g e n = 1 − ( T 1 T 3 ) r p k − 1 k \eta_{th,regen} = 1 - \left(\frac{T_1}{T_3}\right) r_p^{\frac{k-1}{k}} η t h , re g e n = 1 − ( T 3 T 1 ) r p k k − 1
Warning
When Regeneration Degrades Efficiency: If pressure ratio r p r_p r p is very high, compressor exit temperature exceeds turbine exhaust temperature ( T 2 > T 4 T_2 > T_4 T 2 > T 4 ). Installing a regenerator would transfer heat backward from compressor air to exhaust, increasing fuel consumption and degrading efficiency.
3. Combined Cycle Gas Turbine (CCGT) & HRSG
A Combined Cycle Gas Turbine (CCGT) marries the high-temperature capabilities of the Brayton cycle with the low-temperature heat rejection advantages of the Rankine steam cycle. +-----------------------------------------------------------------------------------------+
- | COMBINED CYCLE ARCHITECTURE & ENERGY BALANCE |
- | |
- | Fuel (Q_in) |
- | | |
- | v |
- | +-----------------+ |
- | | TOPPING BRAYTON | ------> Gas Turbine Electric Power (W_dot_gas = eta_g * Q_in) |
- | | GAS TURBINE | |
- | +-----------------+ |
- | | Hot Turbine Exhaust (550 - 650 °C) |
- | v |
- | +-----------------+ |
- | | HRSG (BOILER) | |
- | +-----------------+ |
- | | High-P Superheated Steam |
- | v |
- | +-----------------+ |
- | | BOTTOMING STEAM | ------> Steam Turbine Electric Power (W_dot_steam) |
- | | RANKINE CYCLE | |
- | +-----------------+ |
- | | |
- | v Condenser Waste Heat (Ambient Sink) |
- +-----------------------------------------------------------------------------------------+
- Combined Cycle Thermal Efficiency
The overall combined cycle efficiency is derived directly from the individual cycle efficiencies: W ˙ t o t a l = W ˙ g a s + W ˙ s t e a m = η g a s Q ˙ i n + η s t e a m Q ˙ i n , H R S G \dot{W}_{total} = \dot{W}_{gas} + \dot{W}_{steam} = \eta_{gas} \dot{Q}_{in} + \eta_{steam} \dot{Q}_{in,HRSG} W ˙ t o t a l = W ˙ g a s + W ˙ s t e am = η g a s Q ˙ in + η s t e am Q ˙ in , H RSG
Assuming all waste heat from the gas turbine enters the HRSG ( Q ˙ i n , H R S G = ( 1 − η g a s ) Q ˙ i n \dot{Q}_{in,HRSG} = (1 - \eta_{gas})\dot{Q}_{in} Q ˙ in , H RSG = ( 1 − η g a s ) Q ˙ in ): η c c = W ˙ t o t a l Q ˙ i n = η g a s + η s t e a m ( 1 − η g a s ) = η g a s + η s t e a m − η g a s η s t e a m \eta_{cc} = \frac{\dot{W}_{total}}{\dot{Q}_{in}} = \eta_{gas} + \eta_{steam} (1 - \eta_{gas}) = \eta_{gas} + \eta_{steam} - \eta_{gas} \eta_{steam} η cc = Q ˙ in W ˙ t o t a l = η g a s + η s t e am ( 1 − η g a s ) = η g a s + η s t e am − η g a s η s t e am
Modern heavy-duty F- and H-class CCGT power stations regularly achieve thermal efficiencies exceeding 60 % to 64 % 60\% \text{ to } 64\% 60% to 64% (LHV basis).
4. Internal Combustion Reciprocating Cycles: Otto, Diesel & Dual
Reciprocating engines compress and expand gas within a cylinder bounded by a reciprocating piston. +-----------------------------------------------------------------------------------------+
- | RECIPROCATING ENGINE KINEMATICS |
- | |
- | Bore (D): Piston diameter |
- | Stroke (L): Linear distance between TDC and BDC |
- | Top Dead Center (TDC): Minimum cylinder volume coordinate (Clearance Volume V_c) |
- | Bottom Dead Center (BDC): Maximum cylinder volume coordinate (Total Volume V_max) |
- | Displacement Volume: V_d = V_max - V_c = (pi/4) * D^2 * L |
- | Compression Ratio: r = V_max / V_min = (V_d + V_c) / V_c |
- | Mean Effective Pressure: MEP = W_net / V_d = W_net / (V_max - V_min) |
+-----------------------------------------------------------------------------------------+ P-v: Otto Cycle (Spark-Ignition) P-v: Diesel Cycle (Compression-Ignition)
- P ^ P ^
- | 3 (Peak P & T) | 2 3 (Constant P Combustion)
- | * | *--* (Cutoff Volume V3)
- | /| | / \
- | Comb. / | | Comp. / \ Expansion
- | (V=C) / | Expansion | (1->2)/ \ (3->4)
- | 2 * | (3->4) | 1*----------* 4 (Blowdown)
- | / * 4 (Blowdown) | (BDC: V_max)
- | 1*-----+----------------> v +------+------+-----------------> v
- (TDC:Vc) (BDC:Vmax) (TDC:V2) (V3) (BDC:V1)
- The Air-Standard Otto Cycle (Spark Ignition)
Combustion is modeled as instantaneous constant-volume heat addition ( 2 → 3 2 \to 3 2 → 3 ): η t h , O t t o = 1 − 1 r k − 1 \eta_{th,Otto} = 1 - \frac{1}{r^{k-1}} η t h , Ott o = 1 − r k − 1 1
Compression ratios in gasoline engines are constrained to r ≈ 8 − 11 r \approx 8 - 11 r ≈ 8 − 11 to prevent pre-ignition and engine knock (autoignition of the end-gas).
The Air-Standard Diesel Cycle (Compression Ignition)
Combustion is modeled as constant-pressure heat addition ( 2 → 3 2 \to 3 2 → 3 ) across the Cutoff Ratio ( r c = V 3 / V 2 r_c = V_3 / V_2 r c = V 3 / V 2 ) : η t h , D i e s e l = 1 − 1 r k − 1 [ r c k − 1 k ( r c − 1 ) ] \eta_{th,Diesel} = 1 - \frac{1}{r^{k-1}} \left[\frac{r_c^k - 1}{k (r_c - 1)}\right] η t h , D i ese l = 1 − r k − 1 1 [ k ( r c − 1 ) r c k − 1 ]
Because only air is compressed during the compression stroke, Diesel engines eliminate knock limitations and operate at high compression ratios ( r ≈ 14 − 22 r \approx 14 - 22 r ≈ 14 − 22 ), yielding higher actual thermal efficiencies than Otto engines.
The Dual (Sabathé) Cycle
Modern high-speed diesel engines operate on a Dual Cycle where heat addition occurs partly at constant volume ( 2 → 3 2 \to 3 2 → 3 , pressure ratio r p = P 3 / P 2 r_p = P_3 / P_2 r p = P 3 / P 2 ) and partly at constant pressure ( 3 → 4 3 \to 4 3 → 4 , cutoff ratio r c = V 4 / V 3 r_c = V_4 / V_3 r c = V 4 / V 3 ).
5. Step-by-Step Worked Problem: Regenerative Gas Turbine Analysis
Problem: A gas turbine operating on an air-standard regenerative Brayton cycle draws in ambient air at P 1 = 100 kPa P_1 = 100\text{ kPa} P 1 = 100 kPa ( 14.5 psia 14.5\text{ psia} 14.5 psia ) and T 1 = 300 K T_1 = 300\text{ K} T 1 = 300 K ( 80 ∘ F 80^\circ\text{F} 8 0 ∘ F ). The pressure ratio across the compressor is r p = 8.0 r_p = 8.0 r p = 8.0 . The turbine inlet temperature is T 3 = 1300 K T_3 = 1300\text{ K} T 3 = 1300 K ( 1880 ∘ F 1880^\circ\text{F} 188 0 ∘ F ). The compressor isentropic efficiency is η c = 84 % \eta_c = 84\% η c = 84% , the turbine isentropic efficiency is η t = 88 % \eta_t = 88\% η t = 88% , and the regenerator effectiveness is ϵ = 80 % \epsilon = 80\% ϵ = 80% . Assume cold-air-standard properties ( c p = 1.005 kJ/(kg ⋅ K) , k = 1.40 , ( k − 1 ) / k = 0.2857 c_p = 1.005\text{ kJ/(kg}\cdot\text{K)}, k = 1.40, (k-1)/k = 0.2857 c p = 1.005 kJ/(kg ⋅ K) , k = 1.40 , ( k − 1 ) / k = 0.2857 ). Calculate:
Actual compressor exit temperature ( T 2 a T_{2a} T 2 a ) and actual turbine exhaust temperature ( T 4 a T_{4a} T 4 a )
- Air temperature entering the combustor ( T 5 T_5 T 5 )
- Net specific work produced ( w n e t w_{net} w n e t in kJ/kg \text{kJ/kg} kJ/kg )
Cycle thermal efficiency ( η t h \eta_{th} η t h ) +-----------------------------------------------------------------------------------------+
- | REGENERATIVE BRAYTON CALCULATION STEPS |
- | |
- | STEP 1: Compressor Calculations (P_2/P_1 = 8.0, T_1 = 300 K) |
- | T_2s = T_1 * (r_p)^((k-1)/k) = 300 * (8.0)^0.28571 = 300 * 1.8114 = 543.43 K |
- | w_c,s = c_p * (T_2s - T_1) = 1.005 * (543.43 - 300) = 244.65 kJ/kg |
- | w_c,a = w_c,s / eta_c = 244.65 / 0.84 = 291.25 kJ/kg |
- | T_2a = T_1 + (w_c,a / c_p) = 300 + (291.25 / 1.005) = 589.80 K |
- | |
- | STEP 2: Turbine Calculations (T_3 = 1300 K, P_3/P_4 = 8.0) |
- | T_4s = T_3 / (r_p)^((k-1)/k) = 1300 / 1.8114 = 717.68 K |
- | w_t,s = c_p * (T_3 - T_4s) = 1.005 * (1300 - 717.68) = 585.23 kJ/kg |
- | w_t,a = eta_t * w_t,s = 0.88 * 585.23 = 515.00 kJ/kg |
- | T_4a = T_3 - (w_t,a / c_p) = 1300 - (515.00 / 1.005) = 787.56 K |
- | |
- | STEP 3: Regenerator Heat Transfer (epsilon = 0.80) |
- | T_5 = T_2a + epsilon * (T_4a - T_2a) |
- | T_5 = 589.80 + 0.80 * (787.56 - 589.80) = 589.80 + 0.80 * (197.76) |
- | T_5 = 589.80 + 158.21 = 748.01 K |
- | |
- | STEP 4: Combustor Heat Input (q_in) |
- | q_in = c_p * (T_3 - T_5) = 1.005 * (1300 - 748.01) = 554.75 kJ/kg |
- | (Note: Without regenerator, q_in would be c_p*(1300 - 589.80) = 713.75 kJ/kg) |
- | |
- | STEP 5: Net Work, BWR & Thermal Efficiency |
- | w_net = w_t,a - w_c,a = 515.00 - 291.25 = 223.75 kJ/kg |
- | BWR = w_c,a / w_t,a = 291.25 / 515.00 = 0.5655 = 56.55% |
- | eta_th = w_net / q_in = 223.75 / 554.75 = 0.4033 = 40.33% |
- +-----------------------------------------------------------------------------------------+
- 6. Common Exam Traps & PE Pro-Tips
Trap 1 — Inverting Compressor vs Turbine Isentropic Efficiency: Compressor work is an input ( w c , a c t u a l = w c , s / η c > w c , s w_{c,actual} = w_{c,s} / \eta_c > w_{c,s} w c , a c t u a l = w c , s / η c > w c , s ), whereas turbine work is an output ( w t , a c t u a l = η t ⋅ w t , s < w t , s w_{t,actual} = \eta_t \cdot w_{t,s} < w_{t,s} w t , a c t u a l = η t ⋅ w t , s < w t , s ). Remember that irreversibility always increases work required for compression and decreases work produced during expansion.
Trap 2 — Combined Cycle Efficiency Direct Addition: Never add topping and bottoming efficiencies directly (e.g., 38 % + 32 % ≠ 70 % 38\% + 32\% \ne 70\% 38% + 32% = 70% ). The steam turbine operates solely on the waste thermal stream of the gas turbine, following η c c = η g a s + η s t e a m − η g a s η s t e a m \eta_{cc} = \eta_{gas} + \eta_{steam} - \eta_{gas} \eta_{steam} η cc = η g a s + η s t e am − η g a s η s t e am .
Trap 3 — Mean Effective Pressure Volume Base: In internal combustion reciprocating calculations, M E P = W n e t / V d MEP = W_{net} / V_d MEP = W n e t / V d . Make sure to divide by displacement volume V d = V m a x − V m i n V_d = V_{max} - V_{min} V d = V ma x − V min , not total cylinder volume V m a x V_{max} V ma x .