Study guide
5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration)
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration)
Key Takeaways Explain This Topic AI
The baseline Rankine cycle consists of four continuous processes: isentropic liquid pumping, constant-pressure boiler addition, isentropic turbine expansion, and constant-pressure condenser heat rejection.
Turbine moisture erosion limits turbine exhaust quality to x ≥ 0.88 − 0.90 x \ge 0.88 - 0.90 x ≥ 0.88 − 0.90 ; superheating and reheating safely elevate exhaust quality while simultaneously increasing thermal efficiency.
Reheat cycles increase overall thermal efficiency by 4–5% by raising the average temperature of heat addition without requiring metallurgical upgrades above the primary superheat temperature.
Regenerative Feedwater Heating (using Open and Closed Feedwater Heaters) extracts turbine steam to preheat boiler feedwater, decreasing external heat addition and serving as a deaerator.
Cogeneration (Combined Heat and Power) systems achieve utilization efficiencies of 75–85% by simultaneously producing electricity and industrial process steam from a single fuel input.
Last updated: August 2026
Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration)
The Rankine cycle is the fundamental thermodynamic operating model for vapor-driven power stations worldwide, including fossil fuel, biomass, nuclear, and concentrated solar thermal plants. Unlike the ideal Carnot vapor cycle—which suffers from severe mechanical limitations such as compressing two-phase liquid-vapor mixtures and handling severe turbine droplet impingement—the Rankine cycle operates entirely within practical engineering constraints by condensing steam to saturated liquid before pumping.
1. The Ideal Rankine Cycle: Architecture & Energy Balances
The standard ideal Rankine cycle consists of four steady-flow processes executed in series: +-----------------------------------------------------------------------------------------+
- | IDEAL RANKINE CYCLE FLOW DIAGRAM |
- | |
- | Boiler / Steam Generator |
- | +------------------------+ |
- | | q_in (Q_H) | |
- | +------------------------+ |
- | ^ | |
- | State 2 | High-P Subcooled | State 3: High-P Superheated Steam |
- | Liquid | v |
- | +---------+ | +---------+ |
- | w_p,in --> | PUMP |----+ | TURBINE | ----> w_t,out |
- | +---------+ +---------+ |
- | ^ | |
- | State 1 | Saturated Liquid | State 4: Low-P Wet Mixture |
- | Condensate v |
- | +------------------------+ |
- | | q_out (Q_L) | |
- | +------------------------+ |
- | Condenser |
+-----------------------------------------------------------------------------------------+ T-s Diagram: Ideal Rankine Cycle
- T ^
- | Boiler Heat Addition (2->3)
- | 3 (Superheated Vapor)
- | /|
- | / |
- | 2 / |
- | /|__________/ | Turbine Expansion (3->4s, Isentropic)
- | / | Liquid- |
- | 1--+--Vapor Dome--+-- 4s (Low-P Mixture)
- | | | |
- | +--+--------------+--------> s
- | Pump (1->2s) Condenser Heat Rejection (4->1)
- Mathematical Formulation of Process States
Process Equipment Governing Equation Physical Description
1 → \to → 2 Feed Pump w p , i n = h 2 − h 1 = v 1 ( P 2 − P 1 ) w_{p,in} = h_2 - h_1 = v_1(P_2 - P_1) w p , in = h 2 − h 1 = v 1 ( P 2 − P 1 ) Isentropic liquid compression ( s 2 = s 1 s_2 = s_1 s 2 = s 1 )
2 → \to → 3 Boiler q i n = h 3 − h 2 q_{in} = h_3 - h_2 q in = h 3 − h 2 Isobaric heat addition ( P 2 = P 3 P_2 = P_3 P 2 = P 3 )
3 → \to → 4 Steam Turbine w t , o u t = h 3 − h 4 w_{t,out} = h_3 - h_4 w t , o u t = h 3 − h 4 Isentropic vapor expansion ( s 4 = s 3 s_4 = s_3 s 4 = s 3 )
4 → \to → 1 Condenser q o u t = h 4 − h 1 q_{out} = h_4 - h_1 q o u t = h 4 − h 1 Isobaric heat rejection ( P 4 = P 1 P_4 = P_1 P 4 = P 1 )
Net Work, Thermal Efficiency & Back Work Ratio
The net specific work produced by the cycle is: w n e t = w t , o u t − w p , i n = ( h 3 − h 4 ) − ( h 2 − h 1 ) w_{net} = w_{t,out} - w_{p,in} = (h_3 - h_4) - (h_2 - h_1) w n e t = w t , o u t − w p , in = ( h 3 − h 4 ) − ( h 2 − h 1 )
The Thermal Efficiency ( η t h \eta_{th} η t h ) is defined as: η t h = w n e t q i n = ( h 3 − h 4 ) − ( h 2 − h 1 ) h 3 − h 2 = 1 − q o u t q i n = 1 − h 4 − h 1 h 3 − h 2 \eta_{th} = \frac{w_{net}}{q_{in}} = \frac{(h_3 - h_4) - (h_2 - h_1)}{h_3 - h_2} = 1 - \frac{q_{out}}{q_{in}} = 1 - \frac{h_4 - h_1}{h_3 - h_2} η t h = q in w n e t = h 3 − h 2 ( h 3 − h 4 ) − ( h 2 − h 1 ) = 1 − q in q o u t = 1 − h 3 − h 2 h 4 − h 1
The Back Work Ratio ( B W R BWR B W R ) for a Rankine cycle is remarkably small compared to gas turbine cycles: B W R = w p , i n w t , o u t ≈ 0.005 to 0.02 BWR = \frac{w_{p,in}}{w_{t,out}} \approx 0.005 \text{ to } 0.02 B W R = w t , o u t w p , in ≈ 0.005 to 0.02
Because pumping an incompressible liquid requires minimal work compared to the work extracted by expanding vapor, the pump work is often negligible in preliminary estimates, though critical in exact power plant balances.
2. Real Cycle Deviations & Component Irreversibilities
Actual vapor power cycles deviate from the idealized model due to internal irreversibilities: +-----------------------------------------------------------------------------------------+
- | ACTUAL CYCLE LOSS MECHANISMS |
- | |
- | 1. TURBINE IRREVERSIBILITIES: Fluid friction and blade turbulence cause an entropy |
- | increase (s_4a > s_3), reducing actual work output: |
- | eta_t = (h_3 - h_4a) / (h_3 - h_4s) ==> h_4a = h_3 - eta_t * (h_3 - h_4s) |
- | |
- | 2. PUMP IRREVERSIBILITIES: Mechanical and fluid shear losses increase pump work: |
- | eta_p = w_p,s / w_p,a = v_1*(P_2 - P_1) / (h_2a - h_1) |
- | ==> h_2a = h_1 + [v_1*(P_2 - P_1) / eta_p] |
- | |
- | 3. CONDENSER SUBCOOLING: Cooling condensate below T_sat(P_cond) requires extra boiler |
- | heat to reach saturation, degrading cycle thermal efficiency. |
- | |
- | 4. PRESSURE DROPS: Viscous friction in steam lines and boiler tubes drops P_inlet. |
- +-----------------------------------------------------------------------------------------+
- 3. Superheating & The Reheat Rankine Cycle
To increase cycle efficiency and protect turbine blades from moisture erosion, modern utility boilers superheat steam well above the saturation temperature. However, if boiler pressure is increased to improve efficiency, the expansion path shifts leftward, resulting in dangerously wet steam at the turbine exhaust.
Important
The 10% Moisture Rule: Water droplets moving at high velocities erode turbine blades and degrade aerodynamic stage efficiency. Power plant turbines require exhaust quality x ≥ 0.88 to 0.90 x \ge 0.88 \text{ to } 0.90 x ≥ 0.88 to 0.90 (moisture content ≤ 10 − 12 % \le 10-12\% ≤ 10 − 12% ). T-s Diagram: Reheat Rankine Cycle
- T ^
- | Primary Boiler Addition
- | 3 (HP Inlet)
- | /| 5 (LP Inlet, Reheated)
- | / | /|
- | 2 / | 4 / |
- | /|__________/ |/____/ | LP Expansion (5->6)
- | / | Liquid- | Reheat|
- | 1--+--Vapor Dome--+--------+-- 6 (Safe Quality x > 0.90)
- | +--+--------------+--------+--------> s
- | HP Expansion (3->4) Condenser (6->1)
- The Reheat Thermodynamic Configuration
In a reheat cycle, steam expands through a High-Pressure (HP) Turbine ( 3 → 4 3 \to 4 3 → 4 ), exhausts back to the boiler's reheater tubes where it is reheated at constant pressure to approximately the original inlet temperature ( T 5 ≈ T 3 T_5 \approx T_3 T 5 ≈ T 3 ), and then expands through a Low-Pressure (LP) Turbine ( 5 → 6 5 \to 6 5 → 6 ). w t , t o t a l = w t , H P + w t , L P = ( h 3 − h 4 ) + ( h 5 − h 6 ) w_{t,total} = w_{t,HP} + w_{t,LP} = (h_3 - h_4) + (h_5 - h_6) w t , t o t a l = w t , H P + w t , L P = ( h 3 − h 4 ) + ( h 5 − h 6 ) q i n , t o t a l = q b o i l e r + q r e h e a t = ( h 3 − h 2 ) + ( h 5 − h 4 ) q_{in,total} = q_{boiler} + q_{reheat} = (h_3 - h_2) + (h_5 - h_4) q in , t o t a l = q b o i l er + q re h e a t = ( h 3 − h 2 ) + ( h 5 − h 4 ) η t h , r e h e a t = w t , t o t a l − w p , i n q i n , t o t a l = ( h 3 − h 4 ) + ( h 5 − h 6 ) − ( h 2 − h 1 ) ( h 3 − h 2 ) + ( h 5 − h 4 ) \eta_{th,reheat} = \frac{w_{t,total} - w_{p,in}}{q_{in,total}} = \frac{(h_3 - h_4) + (h_5 - h_6) - (h_2 - h_1)}{(h_3 - h_2) + (h_5 - h_4)} η t h , re h e a t = q in , t o t a l w t , t o t a l − w p , in = ( h 3 − h 2 ) + ( h 5 − h 4 ) ( h 3 − h 4 ) + ( h 5 − h 6 ) − ( h 2 − h 1 )
Tip
Optimum Reheat Pressure Rule: Peak cycle efficiency occurs when the reheat pressure is set to approximately 20 % to 25 % 20\% \text{ to } 25\% 20% to 25% of the maximum boiler pressure ( P r e h e a t ≈ 0.20 − 0.25 × P b o i l e r P_{reheat} \approx 0.20 - 0.25 \times P_{boiler} P re h e a t ≈ 0.20 − 0.25 × P b o i l er ). Reheating increases overall thermal efficiency by 4 % to 5 % 4\% \text{ to } 5\% 4% to 5% .
4. Regenerative Feedwater Heating (FWH)
In standard cycles, cold condensate from the condenser enters the boiler, lowering the average temperature of heat addition ( T m e a n , i n T_{mean,in} T m e an , in ). Regeneration bleeds intermediate-pressure steam from turbine stages to preheat the feedwater before it enters the boiler. +-----------------------------------------------------------------------------------------+
- | OPEN VS CLOSED FEEDWATER HEATERS (FWH) |
- | |
- | OPEN FEEDWATER HEATER (OFWH / Direct Contact): |
- | - Bleed steam mixes directly with feedwater condensate. |
- | - Saturated liquid exits at heater pressure: h_out = h_f(P_heater). |
- | - Serves as a DEAERATOR to strip dissolved O2 and CO2, preventing boiler tube pitting.|
- | - Requires a separate pump after each heater. |
- | |
- | CLOSED FEEDWATER HEATER (CFWH / Shell-and-Tube Indirect Contact): |
- | - Feedwater flows through tubes; extraction steam condenses on shell exterior. |
- | - Streams do not mix; can operate at different pressures. |
- | - Condensate drains are either pumped forward or throttled (trapped) backward. |
- | - Terminal Temperature Difference: TTD = T_sat(P_bleed) - T_fw,out (typically 2-5 °F).|
+-----------------------------------------------------------------------------------------+ Open Feedwater Heater Mass & Energy Balance
- Extraction Steam: y [kg], h_extract, P_FWH
- |
- v
- Feedwater from LP Pump: +----------+
(1 - y) [kg], h_in, P_FWH | OFWH | ---> Saturated Liquid Out to HP Pump:
- -----------------------> | (Direct) | 1.0 [kg], h_out = h_f(P_FWH)
- +----------+
- Extraction Fraction ( y y y ) Calculation for an OFWH
Setting a control volume around the Open Feedwater Heater with 1 kg total flow exiting: y h e x t r a c t + ( 1 − y ) h i n , c o n d e n s a t e = 1.0 ⋅ h f , FWH y h_{extract} + (1 - y) h_{in,condensate} = 1.0 \cdot h_{f,\text{FWH}} y h e x t r a c t + ( 1 − y ) h in , co n d e n s a t e = 1.0 ⋅ h f , FWH y = h f , FWH − h i n , c o n d e n s a t e h e x t r a c t − h i n , c o n d e n s a t e y = \frac{h_{f,\text{FWH}} - h_{in,condensate}}{h_{extract} - h_{in,condensate}} y = h e x t r a c t − h in , co n d e n s a t e h f , FWH − h in , co n d e n s a t e
Total turbine work per unit mass entering the HP stage: w t = ( h i n , H P − h e x t r a c t ) + ( 1 − y ) ( h e x t r a c t − h e x i t , L P ) w_t = (h_{in,HP} - h_{extract}) + (1 - y)(h_{extract} - h_{exit,LP}) w t = ( h in , H P − h e x t r a c t ) + ( 1 − y ) ( h e x t r a c t − h e x i t , L P )
5. Cogeneration & Combined Heat and Power (CHP)
Industrial plants require vast quantities of both electrical power and process steam (for chemical refining, paper manufacturing, district heating). Standalone electricity generation rejects 55 − 65 % 55-65\% 55 − 65% of fuel energy to cooling towers. Cogeneration (CHP) captures this thermal energy for process heating. +-----------------------------------------------------------------------------------------+
- | COGENERATION EFFICIENCY METRIC |
- | |
- | Utilization Factor (Energy Utilization Efficiency): |
- | |
- | W_dot_net + Q_dot_process W_dot_net + m_dot_p * (h_supply - h_ret)|
- | epsilon_u = --------------------------- = ------------------------------------------- |
- | Q_dot_in Q_dot_in |
- | |
- | * Standalone Power Plants: eta_th = 35% - 42% |
- | * Modern Cogeneration CHP: epsilon_u = 75% - 85%+ |
- +-----------------------------------------------------------------------------------------+
- Cogeneration Turbine Architectures
Back-Pressure (Non-Condensing) Turbine: Steam expands through the turbine and exhausts directly at the required process pressure (e.g., 0.5 MPa 0.5\text{ MPa} 0.5 MPa ). All exhaust steam is routed to the process header. Electric power output is rigidly coupled to thermal process demand.
Extraction-Condensing Turbine: High-pressure steam expands to an intermediate pressure where a variable fraction is extracted for process needs. The remainder continues expanding to the condenser, allowing decoupled, flexible electrical generation during process demand swings.
6. Step-by-Step Worked Problem: Reheat Rankine Cycle Analysis
Problem: A power plant operates on a reheat Rankine cycle. High-pressure steam enters the HP turbine at P 3 = 10.0 MPa P_3 = 10.0\text{ MPa} P 3 = 10.0 MPa ( 1450 psia 1450\text{ psia} 1450 psia ) and T 3 = 550 ∘ C T_3 = 550^\circ\text{C} T 3 = 55 0 ∘ C ( 1022 ∘ F 1022^\circ\text{F} 102 2 ∘ F ). Steam expands to P 4 = 2.0 MPa P_4 = 2.0\text{ MPa} P 4 = 2.0 MPa ( 290 psia 290\text{ psia} 290 psia ) where it is reheated to T 5 = 550 ∘ C T_5 = 550^\circ\text{C} T 5 = 55 0 ∘ C . Steam then expands through the LP turbine to a condenser pressure of P 6 = 10 kPa P_6 = 10\text{ kPa} P 6 = 10 kPa ( 1.45 psia 1.45\text{ psia} 1.45 psia ). The HP and LP turbines each have an isentropic efficiency of η t = 85 % \eta_t = 85\% η t = 85% . The feed pump isentropic efficiency is η p = 80 % \eta_p = 80\% η p = 80% . Calculate:
The actual total turbine work output ( w t , a c t u a l w_{t,actual} w t , a c t u a l in kJ/kg \text{kJ/kg} kJ/kg )
The actual feed pump work required ( w p , a c t u a l w_{p,actual} w p , a c t u a l in kJ/kg \text{kJ/kg} kJ/kg )
The total heat added in the boiler and reheater ( q i n , t o t a l q_{in,total} q in , t o t a l in kJ/kg \text{kJ/kg} kJ/kg )
The overall thermal efficiency ( η t h \eta_{th} η t h ) +-----------------------------------------------------------------------------------------+
- | REHEAT CYCLE CALCULATION STEPS |
- | |
- | STEP 1: Condensate & Actual Pump Work (P_1 = 10 kPa -> P_2 = 10 MPa) |
- | h_1 = h_f@10kPa = 191.81 kJ/kg, v_1 = 0.001010 m^3/kg |
- | w_p,s = v_1 * (P_2 - P_1) = 0.001010 * (10000 - 10) = 10.09 kJ/kg |
- | w_p,a = w_p,s / eta_p = 10.09 / 0.80 = 12.61 kJ/kg |
- | h_2a = h_1 + w_p,a = 191.81 + 12.61 = 204.42 kJ/kg |
- | |
- | STEP 2: HP Turbine Expansion (P_3 = 10 MPa, T_3 = 550 °C -> P_4 = 2.0 MPa) |
- | From Superheated Tables: h_3 = 3502.0 kJ/kg, s_3 = 6.7585 kJ/(kg*K) |
- | At P_4 = 2.0 MPa, isentropic state (s_4s = 6.7585): |
- | Interpolating at 2.0 MPa gives h_4s = 2900.5 kJ/kg |
- | w_t,HP,s = h_3 - h_4s = 3502.0 - 2900.5 = 601.5 kJ/kg |
- | w_t,HP,a = eta_t * w_t,HP,s = 0.85 * 601.5 = 511.28 kJ/kg |
- | h_4a = h_3 - w_t,HP,a = 3502.0 - 511.28 = 2990.72 kJ/kg |
- | |
- | STEP 3: Reheater Addition (P = 2.0 MPa, Reheated to T_5 = 550 °C) |
- | From Superheated Tables at 2.0 MPa, 550 °C: |
- | h_5 = 3579.0 kJ/kg, s_5 = 7.5725 kJ/(kg*K) |
- | q_reheat = h_5 - h_4a = 3579.0 - 2990.72 = 588.28 kJ/kg |
- | |
- | STEP 4: LP Turbine Expansion (P_5 = 2.0 MPa -> P_6 = 10 kPa) |
- | At P_6 = 10 kPa: s_f = 0.6492 kJ/(kg*K), s_fg = 7.4996 kJ/(kg*K) |
- | h_f = 191.81 kJ/kg, h_fg = 2392.1 kJ/kg |
- | x_6s = (s_5 - s_f) / s_fg = (7.5725 - 0.6492) / 7.4996 = 0.92315 |
- | h_6s = 191.81 + 0.92315 * (2392.1) = 2400.07 kJ/kg |
- | w_t,LP,s = h_5 - h_6s = 3579.0 - 2400.07 = 1178.93 kJ/kg |
- | w_t,LP,a = eta_t * w_t,LP,s = 0.85 * 1178.93 = 1002.09 kJ/kg |
- | h_6a = h_5 - w_t,LP,a = 3579.0 - 1002.09 = 2576.91 kJ/kg |
- | |
- | STEP 5: Net Performance Totals |
- | Total Actual Turbine Work: |
- | w_t,actual = w_t,HP,a + w_t,LP,a = 511.28 + 1002.09 = 1513.37 kJ/kg |
- | |
- | Net Specific Work: |
- | w_net = w_t,actual - w_p,a = 1513.37 - 12.61 = 1500.76 kJ/kg |
- | |
- | Total Heat Added: |
- | q_in = (h_3 - h_2a) + q_reheat = (3502.0 - 204.42) + 588.28 = 3885.86 kJ/kg |
- | |
- | Thermal Efficiency: |
- | eta_th = w_net / q_in = 1500.76 / 3885.86 = 0.3862 = 38.62% |
- +-----------------------------------------------------------------------------------------+
- 7. Common Exam Traps & PE Pro-Tips
Trap 1 — Reheat Heat Addition Balance: When computing total cycle heat addition ( q i n q_{in} q in ), never forget to add the reheater heat input ( q r e h e a t = h 5 − h 4 q_{reheat} = h_5 - h_4 q re h e a t = h 5 − h 4 ) to the primary boiler heat input ( q b o i l e r = h 3 − h 2 q_{boiler} = h_3 - h_2 q b o i l er = h 3 − h 2 ). Dividing net work by only primary boiler heat yields an erroneously high thermal efficiency.
Trap 2 — OFWH Extraction Steam Balance: In regenerative cycles with an Open Feedwater Heater, remember that the low-pressure turbine produces work only on the unextracted steam fraction ( 1 − y ) (1 - y) ( 1 − y ) . The total turbine work must be weighted: w t = ( h i n , H P − h e x t r a c t ) + ( 1 − y ) ( h e x t r a c t − h e x i t , L P ) w_t = (h_{in,HP} - h_{extract}) + (1 - y)(h_{extract} - h_{exit,LP}) w t = ( h in , H P − h e x t r a c t ) + ( 1 − y ) ( h e x t r a c t − h e x i t , L P ) .
Trap 3 — Condenser Subcooling Penalty: If the problem states that condensate exits the condenser subcooled by Δ T s u b \Delta T_{sub} Δ T s u b below saturation, h 1 h_1 h 1 is evaluated at T = T s a t − Δ T s u b T = T_{sat} - \Delta T_{sub} T = T s a t − Δ T s u b . This requires extra pump and boiler heat, lowering cycle thermal efficiency.